These instructions are to be left with the user

Similar documents
These instructions are to be left with the user

SHOWER FITTINGS. Installation & User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

SHOWER FITTINGS INSTRUCTIONS AND MAINTENANCE GUIDE. Please read carefully before use

These instructions must be left with the user.

These instructions are to be left with the user

These instructions must be left with the user.

MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only)

WATER DELIVERY SYSTEM. Installation & User Guide THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

These instructions are to be left with the user

MIRA ELEMENT SLT THERMOSTATIC MIXER INSTALLATION AND USER GUIDE. These instructions must be left with the user.

These instructions must be left with the user

Mira Select. Installation & User Guide. These instructions must be left with the user. 1

V12 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

Ligature Resistant Head

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

These instructions are to be left with the user

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

These instructions must be left with the user.

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

MIRA PLATINUM. Installation Guide. These instructions are to be left with the user 1

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

Rada-Presto TF2020 and TF2020S

These instructions must be left with the user

320 c PRODUCT MANUAL IMPORTANT

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Mira Platinum Dual. These instructions must be left with the user. Installation Guide

Twin & Triple Control Concealed Thermostatic Shower Valve

215 and 222 Series PRODUCT MANUAL

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Mira Vision. These instructions must be left with the user. Installation Guide

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT

Self-help Temperature Adjustment

Installation and User Guide

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

These instructions must be left with the user

These instructions must be left with the user

Vegas Easyfit Kitchen Sink Mixer

These instructions must be left with the user

These instructions must be left with the user

Atmos Fusion. Thermostatic Concentric Mixer Valve with Riser Rail. Fitting Instructions

Mira Mode Maxim. Digital Mixing Valve. Installation and User Guide Please leave these instructions with the user

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Thermostatic Concentric Mixer Valve. with Exposed and Concealed Fitting Options. Fitting Instructions

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

PRODUCT MANUAL IMPORTANT

Mira Mode Digital Mixing Valve

Options Concentric Petite

Apricot Kitchen Sink Tap

Thermostatic Concentric Mixer Valves

Atmos Zone. Thermostatic Concealed Concentric Mixer Valve with Fixed Head. Fitting Instructions

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Bar valve with fixed shower head Installation guide

Deluge Optimo Shower valve and kit 10032CP

INSTRUCTION MANUAL. Gas Salamander

Atmos 2 Way. Thermostatic Valve with Riser Rail and Overhead. Fitting Instructions

These instructions must be left with the user

These instructions must be left with the user

Atmos Low Pressure Thermostatic Bar Mixer Valve

Flexi-pro Aerosol Delivery System (FADS) Manual

Installation and Use Manual

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

Under Basin Storage Unit

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT

Rapidmain Installation Guide

Horne Engineering Ltd

215 SERIES. NSW Health approve the Rada 215 series TMV for use in healthcare buildings. PRODUCT MANUAL IMPORTANT

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

hydraulic valve 1 Introduction

air/hydraulic nut riveter heavy-duty vacuum system

VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop

PRODUCT MANUAL IMPORTANT

Engineering Data Sheet

Aquor House Hydrant V2

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Installation Instructions Thermostatic Built-In Shower Valves. Basento

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

U.KIT2L (Lever Handles) U.KIT2X (Cross Handles)

Rada sikkerhetsblander, modell 32E M. Best. nr: R NRF-nr:

MANUAL. Sesame. Thermoplastic Tank Technologies

Halsey Taylor Owners Manual

215-t3/222-t3 SERIES

AREA VALVE SERVICE UNITS

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

U.KIT3L (Lever Handles) U.KIT3X (Cross Handles)

Halsey Taylor Owners Manual

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Service and Repair Manual

80 Litre Suction Oil Drainer

Manual Actuated Boiler Blowdown Valves

Flamco Flamco-Fill STA Flamco-Fill STM

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Transcription:

MIRA ECO SHOWER FITTINGS INSTALLATION & USER GUIDE These instructions are to be left with the user 1

CONTENTS Introduction 2 General 2 Pack Contents 3 Pack Contents 4 Specifications 5 Pressures 5 Dimensions 5 Flow Rates 5 Installation 6 RAC Assembly 6 Mira Eco Shower Fittings 8 Operation 9 User Maintenance 10 Fault Diagnosis 10 Cleaning 10 Spare Parts 11 Customer Service 12 If you experience any difficulty with the installation or operation of your new shower fittings, please refer to Fault Diagnosis, before contacting Kohler Mira Ltd. Our contact details can be found on the back cover of this guide. INTRODUCTION Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. Mira ECO adjustable shower fittings are designed to give a satisfactory shower over a range of pressures. These fittings are suitable for pressures between 0.5 and 5.0 bar and are available in chrome or white finishes. General 1. Make sure that the shower fittings are installed by a competent installer. 2. Installations must comply with Water Regulations (Bye-Laws, Scotland), and any other Local Regulations and Building Regulations in force at the time of installation. 3. Before installation carefully inspect the new fixture for any signs of damage. 4. The shower fittings should be positioned at a convenient height for all the family. Position the fittings to spray across rather then towards the opening of the cubicle and also away from the shower control. Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose. 5. A hose retaining ring is supplied to prevent the showerhead from dropping below the spill over level of the bath or shower, which could lead to contamination from backsiphonage. The supplied hose retaining ring should meet the great majority of user requirements for shower installations with flexible outlet fittings. However, there will be occasions when the hose retaining ring will not provide a suitable solution. In these instances an outlet double check valve, e.g. the Mira DCV-H, must be fitted. The inclusion of the Mira DCV-H will increase the required supply pressure typically by 0.1 bar. 6. Special consideration should be given to the fixing arrangements when installing onto a dry lined, stud partition, shower cubicle or laminated panel wall structures. Installers may wish to obtain alternative proprietary cavity fixings, or choose other options, however, these methods of fixing are beyond the scope of this guide. Design Registration 3 003 935 2

PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that all of the parts are included. q 2 x Wall Plugs q 2 x Slide Bar End Supports q 2 x Fixing Screws q 2 x Slide Bar End Caps q 1 x Applicator q 1 x Showerhead q 1 x Slide Bar q 1 x Clamp Bracket q 1 x Hose Retaining Ring q 2 x Hose Seals q 1 x 1.25m Flexible Hose or q 1 x 1.75m Flexible Hose 3

PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that all of the parts are included. Only supplied with Built-In Variable (BIV) fitting. q 1 x Wall Plate q 2 x Wall Plugs q 1 x Backplate q 1 x Olive q 2 x Wall Plate Screws q 1 x Backplate Nut q 2 x Backplate Screws q 2 x 'O' Seals q 1 x Elbow q 1 x Shroud 4

SPECIFICATIONS Pressures Min maintained pressure: 0.5 bar (50 kpa). Max maintained pressure: 5.0 bar (500 kpa). Warning! Exceeding the stated maximum maintained pressure could result in excessive back pressure and possible damage to the product. Dimensions Flow Rates These are the typical flow performance graphs for the Mira Eco shower fittings. There will be an additional pressure loss through the shower control. Pressure loss = Pressure difference between the inlet and outlet of the fitting. The graph below shows the water saving made using the Mira Eco showerhead v a standard three mode Mira High Capacity Logic showerhead. 344mm Max. Flow Rate (l/min) 45.0 40.0 35.0 30.0 25.0 20.0 15.0 10.0 Start eco / Soothe eco / Force eco modes Start / Force mode Logic Soothe mode Logic 659 mm 5.0 0.0 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 Pressure (bar) 1.4 1.5 1.6 1.7 1.8 1.9 2.0 5

INSTALLATION RAC Assembly The RAC assembly is supplied with built-in mixer showers only. 1. Before the RAC assembly can be fitted you must have first installed your built-in shower control and have connected the inlet and outlet pipework. Refer to your shower control installation and user guide. Important! Make sure that the outlet pipework protrudes through a Ø25 mm hole in the wall or stud partition by approximately 40 mm. Note! For stud partition installations where access to the rear of the partition is possible, fit the RAC wallplate over the outlet pipework on the inside of the partition. For stud partition installations where access to the rear of the wall is not possible, follow instructions for solid wall installations, making sure that suitable wall fixings (not supplied) are used to secure the wallplate to the outside of the stud partition. RAC Wallplate (shown fitted for rear access stud partitions only) 4. For solid wall installations or stud partition installations without rear access go to instruction 9. For stud partition installations with access to the rear of the partition continue with instruction 5. 5. Finish the wall (e.g. tiles). Important! Refer to your shower control installation and user guide. Caution! Make sure that the finished wall is within the maximum and minimum limits and to an even depth (no greater than 2 mm variation). 6. Place the RAC backplate over the outlet pipe with the arrow pointing up. The screw holes should be at 45 to the horizontal. 7. Mark the positions of the two RAC backplate fixing holes and drill the two 5.5 mm holes. Caution! Make sure that you do not drill into pipework in the wall. 8. Hold the RAC wallplate in position on the rear of the partition, insert the two backplate screws and secure the RAC backplate to the wallplate. Make sure that the foam seal abuts the finished wall surface. Go to instruction 17. 40 mm Outlet Pipe to Fittings RAC Backplate Backplate Screws Thermostatic Mixing Valve 2. Temporarily cap off the outlet pipe, turn on the water supplies and check for leaks. 3. Determine the finished wall position (e.g. tile thickness). Turn off the water supply, carefully uncap the outlet pipe and cut to length, the outlet pipe must protrude through the finished wall surface by 21 23 mm. Note! Remove any burrs from the pipes before proceeding. 6

9. Loosely attach the RAC backplate to the RAC wallplate, using the two backplate screws provided. 10. Place the RAC backplate/wallplate assembly over the outlet pipe with the arrow pointing vertically up. The screw holes should be at 40 to the horizontal. 11. Mark the positions of the two RAC wallplate fixing holes. 16. Place the backplate over the outlet pipe with the arrow pointing vertically up and tighten the two backplate screws. Make sure that the foam seal abuts the finished wall surface. RAC Backplate Backplate Screws Wallplate 40 RAC Backplate Backplate Screws Arrow 11. Remove the assembly from the wall and separate the backplate from the wallplate. 12. For solid walls drill two 6 mm holes for the wall plugs. For other types of wall structure alternative fixings may be required (not supplied). If necessary, make a recess 6 mm deep to accept the wallplate for flush fitting of the outlet to the wall surface. Caution! Make sure that you do not drill into pipework in the wall. 13. Fit the two wall plugs supplied and secure the wallplate to the wall with the two wallplate screws. 14. Make sure that there is clearance behind the wallplate and temporarily fit the two backplate screws into the wallplate. This will prevent the fixing holes from becoming blocked with plaster or grout. 15. Finish the wall, e.g. tiles. then remove the two backplate screws. Important! Refer to your shower control installation and user guide. Caution! Make sure that the finished wall is within the maximum and minimum limits and to an even depth (no greater than 2 mm variation). 17. Check that the blue O seal is fitted inside the backplate nut. Fit the olive and the backplate nut over the outlet pipe and tighten the nut. 18. Check that the second O seal (black) is fitted to the outside of the backplate nut. Press the elbow onto the backplate, make sure that the clips on the elbow engage with the backplate. 19. Press the shroud over the elbow, make sure that it engages with the lugs on the backplate. Olive Backplate Nut Shroud Elbow 20. This completes the installation of the RAC assembly, continue with the installation of the EV Shower Fittings. 7

Mira Eco Shower Fittings 1. Decide on a suitable position for the slide bar avoiding buried cables and pipes. 2. Important! The slide bar has an applicator fitted to one end to assist the assembly of the slide bar through the clamp bracket (see illustration). With the clamp bracket button FULLY depressed carefully ease the slide bar through the hole in the clamp bracket, take care not to dislodge the constant friction mechanism or friction pad. 3. Release the clamp bracket button. Remove the applicator from the slide bar and store in a safe place for future use. 4. Slide the hose retaining ring onto the slide bar below the clamp bracket. 5. Make sure that the slots in the slide bar are aligned with the lugs in the support and fit the two slide bar supports to the ends of the slide bar. Make sure that each support is pushed firmly home. Note! If replacing an existing Mira Slide Bar go to instruction 8. 6. Using the assembled slide bar and supports as a template, mark the position of the two fixing holes using the centre slot. Warning! Make sure that there are no buried cables or pipes in the wall before drilling. 7. Drill the two 8 mm holes for the fixing screws and insert the wall plugs supplied. (Alternatively use proprietary cavity fixings for dry lined, stud partition, shower cubicle or laminated panel walls). 8. Fix the bottom slide bar support to the wall using the screw provided. Make sure that the screw is fully tightened. 9. Loosely screw the top slide bar support to the wall. Press firmly down on the top slide bar support and, while continuing to apply force, fully tighten the screw. 10. Fit the end caps to the slide bar supports. 11. Pass the flexible hose through the hose retaining ring. 12. Screw the hose onto the showerhead and the outlet of the shower control or RAC assembly (Make sure the hose seals are fitted) Do not overtighten. Place the shower head into the clamp bracket. 600 Clamp Bracket Constant Friction Mechanism and Friction Pad Applicator Slide Bar Wall Plug Top Slide Bar Support Fixing Screw End Cap Slide Bar Clamp Bracket Assembly Hose Retaining Ring Slide Bar Support Lug Bottom Slide Bar Support End Cap 8

OPERATION Changing the Spray Setting The showerhead spray head has four different spray actions:- Start, Soothe and Force. 1. Start Turn the spray plate anticlockwise until it clicks (one click from the eco setting). Water will flow from the outer set of holes. 2. Soothe Turn the spray plate anticlockwise until it clicks (two clicks from the eco setting). Water will flow from the large diameter holes. 3. Force Turn the spray plate anticlockwise until it clicks (three clicks from the eco setting). Water will flow from the inner set of holes. Height and Direction Adjustment Release Button 9

USER MAINTENANCE If you require a Mira trained service engineer or agent, refer to section: Customer Services. Fault Diagnosis Symptom: No flow or low flow rate from shower fittings. Cause / Rectification: Spray plate blocked, clean or renew. Make sure that the hose is not blocked or twisted. Head of water below minimum required (Min supply pressure 0.5 Bar) Problem with the shower control, refer to your shower control installation and user guide. Symptom: Drip from the showerhead. Cause / Rectification: A small amount of water may be retained in the showerhead after the shower control has been turned off. This is quite normal, changing the angle of the showerhead may vary the draining time. Problem with the shower control, refer to your shower control installation and user guide. Symptom: Shower temperature changes when spray action is adjusted. Cause / Rectification: Adjusting the spray action changes the flow of water. This may affect some shower controls and plumbing installations. To minimise the effect make sure that the spray plate is clean. Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. Use your thumb or a soft cloth to wipe any limescale from the soft nozzles and the front surface of the showerhead spray plate. Important! The spray plate must be regularly cleaned to make sure that the showerhead does not become blocked. Spray Plate Assembly - Internal 1. Remove the spray plate assembly. 2. Clean all the components with a stiff brush. If necessary use a plastic kettle descalent in accordance with the manufacturer's instructions. Flush thoroughly with water before the shower is used. 3. If necessary replace the 'O' seals. Refer to section: Spare Parts. 4. Refit the components in reverse order. Make sure that the 'O' seals and the inner and outer nozzle retaining rings are fitted correctly. Showerhead Body Outer Nozzle Ring Retainer 'O' Seals Inner Nozzle Ring Retainer Spray Plate Assembly Adjuster Ring 10

SPARE PARTS 450.17 Slide Bar Wall Fixing Pack 450.10 Slide Bar White 450.28 Slide Bar Chrome 1668.026 Adjustable Showerhead (White) 1668.025 Adjustable Showerhead (Chrome) 450.08 Seal Pack 450.21 Right Angle Connector White 450.22 Right Angle Connector Chrome 450.20 Right Angle Connector Pack 632.73 Hose Seal (x2) 450.01 Hose 1.25m Chrome 450.02 Hose 1.25m White 464.11 Hose 1.75 Chrome 1668.029 Spray Plate Pack (Chrome) 1668.030 Spray Plate Pack (White) 450.24 Clamp Bracket (chrome) 450.16 Clamp Bracket (white) 450.13 Adjuster Ring White 450.13 Adjuster Ring Chrome 450.30 Hose Retaining Ring (chrome) 450.11 Hose Retaining Ring (white) 450.26 Slide Bar Support Assembly White 450.27 Slide Bar Support Assembly Chrome 11

CUSTOMER SERVICE Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase. To activate this guarantee, please return your completed registration card, visit our website or free phone 0800 0731248 within 30 days of purchase (UK only). Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose. If you have not previously activated the guarantee, you will be required to do so prior to the provision of assistance. If you do not activate your guarantee our Engineer will be entitled to charge full payment for the visit (Call out fee plus parts). This guarantee is in addition to your statutory rights and is subject to the following conditions: The product must be installed and maintained in accordance with the instructions given in this user guide. Servicing must only be undertaken by us or our appointed representative. Note! if a service visit is required the product must be fully installed and connected to services. Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date. For shower fi ttings or consumable items we reserve the right to supply replacement parts only. The guarantee does not cover: Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked fi lters) or where no fault has been found with the product. Water or electrical supply, waste and isolation issues. Compensation for loss of use of the product or consequential loss of any kind. Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative. Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes. What to do if something goes wrong If your product does not function correctly when you fi rst use it, contact your installer to check that it is installed and commissioned in accordance with the instructions in this manual. Should this not resolve the issue, contact our Customer Services Team who will offer you or your installer advice and if applicable arrange for a Service Technician to call. If the performance of your product declines, check in this manual to see if simple home maintenance is required. If you require further assistance call our Customer Services Team. Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy (excludes Eire). Ring 01922 471763 for more details. Helpdesk Service Our dedicated Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit. We will need you to have your model name or number, power rating (if applicable) and date of purchase. As part of our quality and training programme calls may be recorded or monitored. Mira Showers Website (www.mirashowers.co.uk) From our website you can register your guarantee, download additional user guides, diagnose faults, purchase our full range of accessories and popular spares, refer to our FAQ s and request a service visit. Spares and Accessories We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product s expected life. Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within two working days. Items purchased from us are guaranteed for 12 months from date of purchase. For safety reasons spares exposed to mains voltages should only be fi tted by competent persons. Returns items can be returned within one month of date of purchase, providing that they are in good condition and the packaging is unopened. Please obtain authorisation from our Customer Services Team before return. We reserve the right to apply a 15% restocking charge. Service / Repairs We have a nationwide team of Service Technicians who can carry out all service or repair work to your product within the guarantee period and beyond. You have the assurance of a fully trained Mira Technician, genuine Mira spare parts and a 12 month guarantee on any chargeable work done. Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards. To Contact Us UK Telephone: 0844 571 5000 www.mirashowers.co.uk E-mail: technical@mirashowers.com Fax: 01242 282595 By Post: Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP Eire Telephone: 01 459 1344 E-mail: sales@modernplant.ie Fax: Dublin 01 459 2329 By Post: Modern Plant Ltd (Dublin), Otter House, Naas Road, Clondalkin, Dublin 22 Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifi cations without notice. FM 14648 1096015-W2-B (L97F) 12 Kohler Mira Limited, January 2011