TUV Low Pressure Mercury

Similar documents
Product Description TUV PL-L

Knowing you re safe. Philips UV purification lamp systems offer highest reliability, enabling maximum protection of water and air quality

Compact4Pool. pool filters. For spas and swimming pools by up to 20,000 litres Pump, filter, pre-filter and UV-C in one. Advantages of Compact4pool:

Knowing you re safe. Philips UV purification lamp systems offer highest reliability, enabling maximum protection of water and air quality

Knowing your water and air are clean

Together we can be sure it s pure

DELTA-UV ULTRAVIOLET DISINFECTION SYSTEMS

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed fixtures.

POWERBALL HCI -TC. Technical Information. POWERBALL HCI -TC for enclosed luminaires.

POWERBALL HCI -T. Technical Information. POWERBALL HCI -T for enclosed luminaires.

HCI-T 70 W/942 NDL PB

HCI-T 70 W/942 NDL PB

Graphic Arts Lamps. Metal Halide Pulse Xenon Quartz Halogen Quartz IR Heater Short Arc Xenon

Product Features Product Benefits Application

LED LED Street Lamps. Industrial / Commercial LED "Corn" Lamps. 360 Beam Angle. Color 30=3000k 40=4000k 50=5000k 60=6000k.

DULUX L LUMILUX DE LUXE

Safety Tips for Using Germicidal Lamps

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

QT-FIT8 2X58-70/ VS20

Special halogen lamps

The AR111 LED is ideal solution for spot lighting in shops

Operation Manual ARTICEL SunSun CUF SunSun CUF SunSun CUF-6000

QT-FIT8 2X58-70/ VS20

Airfield Lighting. For your runway and taxiway safety

Ozone PLUS Germicidal UV Advanced Oxidation Process (AOP) A Synergistic Sanitation Approach for Residential Pools

DELTA UV RESIDENTIAL ULTRAVIOLET DISINFECTION SYSTEMS

QTi DALI/DIM / QTi GII / QTP5

XPOSE UV-C QUICK INSTALLATION GUIDE

HCI-TT 250 W/942 NDL PB

Energy, Temperature and Heat

CJMJ.DPNQBDU. Instruction for use. Neonatal phototherapy device. BILI-COMPACT WY 1816/ Year of manufacture D2017_00

swimming pool technology

Solar Eclipse AOP for Pools

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

Solar Eclipse Brings AOP to the Residential Pool

QTi DALI/DIM / QTi GII / QTP5

Biological Safety Cabinet Guidelines

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

QTi DALI/DIM / QTi GII / QTP5

ADVANCED OXIDATION PROCESS

Streetlight intelligent light corn light floodlight tube panel light bulbs spotlight strip light copper wire bulkhead down light MAGNATECH LED

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

LAMP SUGC/S400-A5

POWERBALL HCI-T. Product family datasheet. Metal halide lamps with ceramic technology for enclosed luminaires

LUMILUX T5 HO CONSTANT

XSL-360-5E. UV LED 5 mm TECHNICAL DATA. Absolute Maximum Ratings (T a =25 C) Specifications (If=20mA, T a =25 C) Drawing

BIOLAB ULTRA VIOLET LIGHT TECHNOLOGY GENERAL UV QUESTIONS

LAMP 339-9SUGSURSUBC/S1174

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Manual. Immersion radiator unit TS 40

CURION 185 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 80 EN60598 / EN62031 / EN62471 >25 >25.

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

LAMP 336SURSYGWS530-A3

1224SUBC/C470/S400-A4

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings

SWIMMING POOLS. Catalogue 2017

Columbus Instruments

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

LED lighting systems

Automatic Twin Greasing System

Less power great performances

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

fact file use of UV in swimming pools The use of UV for destruction of combined chlorine Ing A Beyer, Ing H Worner and BaE R van Lierop

liniled Handrail liniled Handrail Number of LEDs

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Alhena. Alhena. Infant Warmers. Quality for life

Section 4.2. Travelling Waves

T-CITY. Waterproof protection for LED lighting

First term Revision Paper - Physics. Year 9

A smooth design solution for a seamless look

Physics 1-2 Mr. Chumbley Physics: Chapter 11 p

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

UVGI Device for Direct Irradiations UV-DIRECT-NX

Verdi G-Series Family

Instructions for use. medisun 400 / 700. UV-phototherapy-device. UVB-311nm UVA UVA / UVB 3,3% Lamp configuration:

EX-RECESSED CEILING LIGHT FITTINGS

User Instruction & Installation Manual FSP300 Signalling Projector

A smooth design solution for a seamless look

UVrevolutionary pool disinfection

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Physical Science 1 Chapter 6 WAVES. A wave is a disturbance that is propagated through a system. Waves transfer energy.

Technical Data Sheet 339-9SUGSURSUBC/S1182. Features. Descriptions. Applications. Device Selection Guide

UsER manual for Watersens ph -REDOX

Food Lamps - Toughcoat TM

TECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC

The Nature of Light. Light behaves like a special kind of wave, called an electromagnetic wave.

TECHNICAL DESCRIPTION

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

Instruction and Maintenance Manual

Atmospheric Pressure. Conceptual Physics 11 th Edition. Atmospheric Pressure. Atmospheric Pressure. The Atmosphere

Halogen free cable. Halogen free cable

TECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam

Installation, use and maintenance instructions. Gas burner (5)

Instruction and Maintenance Manual

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

M.M.C. International B.V.

JASCO 810 CD SPECTROPLOARIMETER STANDARD OPERATING PROCEDURE

Neon Flex. High quality Neon Rope Light for spectacular outdoor lighting effects

Transcription:

PHI3166 Air Water Leaflet 5/5/04 4:09 PM Page 2 Perfection Preserved b y t h e p u r e s t o f l i g h t We r e n o t t h e o n l y o n e s w h o e n j o y s w i m m i n g i n t h e w a t e r o r f ly i n g i n t h e a i r

PHI3166 Air Water Leaflet 5/5/04 4:09 PM Page 3 TUV Low Pressure Mercury Philips TUV lamps emit short-wave ultraviolet radiation (UV-C) to kill or de-activate bacteria, viruses and other primitive organisms, even if the organisms have become immune to other disinfection methods. They are used for air, water and surface disinfection in equipment for hospitals, bacteriological research and pharmaceutical institutions, food processing industries such as dairies, breweries and bakeries, and also for disinfecting drinking and waste water, swimming pools, air conditioning systems, cold storage rooms, packing material etc. TUV disinfection lamps are low-pressure mercury-vapour discharge lamps consisting of a tubular glass envelope, emitting short-wave ultraviolet radiation with a radiation peak at 253.7 nm (UV-C) for germicidal action. The glass filters out the 185 nm ozone-forming line. A protective coating on the inside limits the depreciation of the useful UV-C radiation output. PL-S have a specially adapted starter providing almost instant starting characteristics already built into the lamp base. NOTE: Radiation from UV-C lamps is harmful to eyes and skin. Equipment using these lamps must screen completely from direct view.

PHI3166 Air Water Leaflet 5/5/04 4:09 PM Page 4 Lamps Type Cap/ Lamp Lamp Lamp UV-C µw/cm 2 at Depreciation Useful base Wattage voltage current 100h 1 meter 8000 hr lifetime W V A W % h TUV TUV 4W G5 4 29 0.17 0.9 9 25 6000 TUV 6W G5 6 42 0.16 1.5 15 25 8000 TUV 8W G5 8 56 0.15 2.1 21 25 8000 TUV 10W G13 10 46 0.23 2.2 23 25 8000 TUV 11W G5 11 37 0.33 2.2 21 20 8000 TUV 15W G13 15 51 0.34 4.7 48 15 8000 TUV 16W G5 16 46 0.35 3.4 33 20 8000 TUV 25W G13 25 46 0.60 7.0 69 15 8000 TUV 30W G13 30 100 0.37 11.2 100 15 8000 TUV 36W G13 36 103 0.44 15.3 145 15 8000 TUV 55W HO G13 55 83 0.77 18.0 150 15 8000 TUV 75W HO G13 75 108 0.84 26.0 220 15 8000 TUV 115W-R VHO G13 115 92 1.50 33.5 610 20 5000 TUV 115W VHO G13 115 92 1.50 38.8 360 15 5000 TUV PL-S TUV 5W G23 5 34 0.18 1.0 9 15 8000 TUV 9W G23 9 60 0.17 2.4 22 15 8000 TUV 9W 4 pin 2G7 9 60 0.17 2.4 22 15 8000 TUV 11W G23 11 89 0.16 3.6 33 15 8000 TUV 13W G23 13 59 0.29 3.4 31 15 8000 TUV PL-L TUV 18W 2G11 18 60 0.37 5.5 51 15 8000 TUV 24W 2G11 24 87 0.35 7.0 65 15 8000 TUV 35W HO 2G11 35 40 0.85 11.0 105 15 8000 TUV 36W 2G11 36 105 0.44 12.0 110 15 8000 TUV 55W HF 2G11 55 103 0.54 17.0 156 15 8000 TUV 60W HO 2G11 60 118 0.67 18.0 166 15 8000 TUV 95W HO 2G11 95 100 0.95 32.0 304 15 8000 UV-C output in % TUV: Maintenance: relation between UV-C output and burning time TUV Lamps 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Burning time in hours 253.7 313.0 365.5 404.7 435.8 546.1 578.0 Wavelength in nm

PHI3166 Air Water Leaflet 5/5/04 4:09 PM Page 5 A B C D Type H 38 max. 18 max. max. max. Cap/base 2G11 TUV 18W PL-L 195 225 TUV 35W HO PL-L 195 225 TUV 36W PL-L 385 415 TUV 55W HF PL-L 505 535 TUV 60W HO PL-L 385 415 TUV 95W HOPL-L 505 535 H Type A B B C D Cap/base G5 max. min. max. max. max. TUV 4W 135.9 140.6 143.0 150.1 16.0 TUV 6W 212.1 216.8 219.2 226.3 16.0 TUV 8W 288.3 293.0 295.4 302.5 16.0 TUV 11W 212.1 216.8 219.2 226.3 16.0 TUV 16W Cap/base G13 288.3 293.0 295.4 302.5 16.0 TUV 10W 331.5 336.2 338.6 345.7 28.0 TUV 15W 437.4 442.1 444.5 451.6 28.0 TUV 25W 437.4 442.1 444.5 451.6 28.0 TUV 30W 894.6 899.3 901.7 908.8 28.0 TUV 36W 1199.4 1204.1 1206.5 1213.6 28.0 TUV 55W HO 894.6 899.3 901.7 908.8 28.0 TUV 75W HO 1199.4 1204.1 1206.5 1213.6 28.0 TUV 115W VHO, -R VHO 1199.4 1204.1 1206.5 1213.6 40.5 28 max. H L 13 max. Type H L max. max.max. Cap/base G23 TUV 5W PL-S 67 83 105 TUV 9W PL-S 129 145 167 TUV11W PL-S 198 214 236 28 max. 13 max. 28 max. 13 max. 128 max. 145 max. 152 max. 139,5 155,2 177,7 PLS 9W 4P 2G7 TUV PL-S 13W G23 33.3 16 Ø 19.0 7.3 6.35 33.3 Ø 19.0 9.0 7.9 Ø 2.36 7.92 16 Z Z Type Z Cap/base single-pin TUV 36 SP T5 762 842.4±3.0 860.4±3.5 TUV 64 SP T5 1473 1553.6±3.0 1571.6±3.5 Type Z Cap/base 4-pin, single-ended TUV 36 (HO) 4P-SE T5 762 842.4±3.0 849.5±3.5 TUV 64 (HO) 4P-SE T5 1473 1553.6±3.0 1561.0±3.5 TUV 11W 4P-SE 161 241.1±3.0 248.4±3.5 TUV 16W 4P-SE 237 317.3±3.0 324.6±3.5 TUV 25W 4P-SE 466 545.9±.0 553.2±3.5 Type Cap/ Lamp Lamp Lamp UV-C µw/cm 2 at Depreciation Useful base wattage voltage current 100h 1 meter 8000h lifetime W V ma W % h TUV 36 T5 HO 4P-SE 4-pin single-ended 75* 97* 800* 25.0 230 20 9000 TUV 64 T5 HO 4P-SE 4-pin single-ended 145* 175* 800* 48.0 442 20 9000 TUV 36 SP T5 single-pin 40* 94* 425* 15.0 144 15 9000 TUV 64 SP T5 single-pin 75* 176* 425* 31.0 280 15 9000 TUV 36 4P-SE T5 4-pin single-ended 40* 94* 425* 15.0 144 15 9000 TUV 64 4P-SE T5 4-pin single-ended 75* 176* 425* 31.0 280 15 9000 TUV 11W 4P-SE 4-pin single-ended 11** 37** 330** 2.2 21 25 8000 TUV 16W 4P-SE 4-pin single-ended 16** 46** 400** 3.4 33 25 8000 TUV 25W 4P-SE 4-pin single-ended 25 82 350 7.2 66 25 8000 * When used with electronic gear 25 khz HF ** When used with conventional magnetic ballast 50 Hz

PHI3166 Air Water Leaflet 5/5/04 4:09 PM Page 6 Low Pressure Amalgam Lamps The amalgam lamp combines advantages of the low-pressure and the medium-pressure lamp. By doing this the gap is filled between the low-pressure and the medium-pressure applications. The amalgam lamp combines high efficiencies with relative high power densities operating in a broad temperature range. UV-C output in % TUV: Maintenance: relation between UV-C output and burning time 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Burning time in hours For Philips, the advantages of the amalgam concept are clear. By using our long history of lamp development we were able to design a lamp with a very high UV-C efficiency and by applying our patented coating technology we are able to guarantee a maintenance of 85% after 9000 hours operating in a broad temperature range. Amalgam Lamps 253.7 313.0 365.5 404.7 435.8 546.1 578.0 Wavelength in nm A W B C D Z Type T10 A B C D max (mm) max (mm) max (mm) max (mm) TUV 330W PT 32 1440 1520 1540 TUV 270W PT 32 1440 1520 1540 Type T6 W Z max (mm) max (mm) max (mm) max (mm) TUV 325W PT* 19 1480 1540 1580 TUV 130W PT* 19 740 800 840 * In development, available end of 2004 Type Cap Lamp Lamp Lamp UVC µw/cm 2 Depreciation Useful base wattage voltage current 100h at 9000h lifetime W V A W 1 meter % h TUV 330W PT Cable or 4p-SE 330 76 4.8 110 990 85 12.000 TUV 270W PT G9.5/26 270 75 3.8 94 846 85 12.000 TUV 325W PT* 4p-SE 325 145 2.3 108 972 80 12.000 TUV 130W PT* 4p-SE 132 72 2.1 52 468 80 12.000

PHI3166 Air Water Leaflet 5/5/04 4:09 PM Page 7 HOK/HTK/HTQ Medium Pressure Mercury Lamps Medium Pressure Mercury UV lamps Philips Lighting BV manufactures, and internationally distributes a wide range of high quality medium pressure mercury ultraviolet lamps. These quartz lamps are available up to 120 Watts per cm, with an arc length of 4 to 140 cm, in a variety of end fittings.the lamps are made from selected types of quartz glass, manufactured at Philips Lightings own factories. Philips Lighting medium pressure lamps contain sophisticated quantities of mercury bromides, providing a self-cleaning halogen cycle, to control the decline of UV radiation over lamplife. Spectral output The lamps emit the characteristic spectrum of mercury discharge lamps. The HOK and HTK types also radiate wavelengths below 240 nm, whereby ozone is formed. The special quartz of the HTQ lamps absorbs radiation below 240 nm. UV-C output in % HOK: Maintenance: relation between UV-C output and burning time HOK Lamps 0 1000 2000 3000 4000 5000 Burning time in hours 100 200 300 400 500 600 700 Wavelength in nm Type Arc Overall Tube Lamp Lamp Lamp UV-C UV-B UV-A µw/cm 2 at length lamp diameter wattage voltage current >210nm 1 meter mm length mm W V A W W W HOK 4/120 29 104.0 14 400 125 3.5 53 32 31 488 HOK 4/120 SE* 29 110.0 14 400 125 3.5 53 32 31 488 HOK 20/100 195 262.0 22 2000 245 9.6 325 198 175 2990 HOK 35/120 348 428.0 22 4300 510 10.3 759 403 351 6983 HOK 50/120 500 580.0 22 6000 1050 10 1060 546 462 9752 HOK 65/120 637 717.0 22 7800 910 10.3 1278 741 722 11758 HOK 80/120 800 880.0 22 9600 1080 10.5 1568 926 829 14426 HOK 105/120 1057 1137.0 22 12400 1430 10 2021 1244 1042 18593 HOK 140/120 1407 1487.0 22 17000 1920 10 2860 1646 1380 26312 HTK 7/60 700 770.0 14 4000 1400 3.1 593 380 321 5456 HTQ 7 700 762.5 14 2000 1400 1.7 130 165 142 1196 HTQ 14 1400 1485.0 22 4000 1400 3.1 280 350 300 2576 HOK 10/120L 106 232.0 22 1000 145 7.5 135 80 80 1250 HOK 15/120L 151 277.0 22 1450 150 10 185 135 128 1720 HOK 20/120L 204 332.0 22 2000 240 9.7 280 180 175 2570 HOK 25/120L 254 382.0 22 2800 275 10 466 280 255 4290 * SE = single ended Please note: Permissible bulb temperatures: Permissible pinch temperatures: HOK: 600-900 C HTK, HTQ: 500-700 C 300 C

PHI3166 Air Water Leaflet 5/5/04 4:10 PM Page 8 Tip height: 3.5 max 14 max 16 max 29 91.5 ± 1.5 105 max 14 max 51 ± 1,5 29 ± 1.5 110 max HOK 4/120 HOK 4/120 SE 24 max 24 max 195 ± 2 252 262 max HOK 20/100 HOK 35/120, HOK 50/120, HOK 65/120, HOK 80/120, HOK 105/120, HOK 140/120 14.5 max 15 ± 1 16/22 700 ± 2 755 ± 2 770 ± 2 105 ± 3 HTK 7/60 HTQ 7, HTQ 14 24 = Arc length = Overall lamp length HOK 10/120L, HOK 15/120L, HOK 20/120L, HOK 25/120L

PHI3166 Air Water Leaflet 5/5/04 4:08 PM Page 1 For more information or support: Philips Lighting B.V. Zwaanhoefstraat 2 4702 LC Roosendaal The Netherlands Tel: +31 165 577906 Fax: +31 165 577907 www.uvdisinfection.philips.com 3222 635 46731 Data subject to change 05/04 Printed in The Netherlands