EPRB-2 Pressure Transducer

Similar documents
P900. P900, Datenblatt Seite 1 DESCRIPTION

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

86BSD Backside Digital Output

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

ATM.ECO - Analog Pressure Transmitter

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM - Analog Pressure Transmitter

P9000 Series Pressure Transducer

OPTIBAR P 1010 C Technical Datasheet

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Parametrable / Programmable Pressure Transmitter

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Programmable pressure and temperature transmitters PTM/RS485

JUMO dtrans p30 Pressure Transmitter

ATM/Ex - Analog Pressure Transmitter

Programmable pressure and temperature transmitters PTM/RS485

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

ATM.1ST/Ex - High Precision Transmitter

Relative pressure switch type 521

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Digitale manometers. TYPE: ETD-01, klasse 0.5. Specificaties HOOFDSTUK 6

MS52XX-C&T SMD Pressure Sensor

M iniature Amplified Pressure Sensors

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Programmable Submersible Level Transmitters

Pressure transmitters EMP 2

PC10 Piezoresistive Silicon Pressure Sensor

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

MB610 Industrial Pressure Transmitter

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

P900 Series Pressure Transducer

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Relative pressure transmitter type 520

P499 Heavy Duty Pressure Transducer

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SENSORS Pressure CALDARO

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

SITRANS P measuring instruments for pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

Type S-10, S-11 General Purpose Pressure Transmitters

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

T EK-SUB 4800C 19 mm Submersible Level Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

MPM280 Piezoresistive OEM Pressure Sensor

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Pressure Measurement Single-range transmitters for general applications

Pressure Transmitter P41

Miniature Pressure Sensors

CDP-100S Pressure Type Level Transmitter

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

BS12N Piezoresistive OEM Pressure Sensor

Deep Submersible Level Transducer Series 300DS

BS12 Piezoresistive OEM Pressure Sensor

ASIC-Based Small Bore Submersible Level Transducer

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Dynisco SPX Industrial (2280/2281) Series

GEMS SENSORS & CONTROLS

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

MPM280 Piezoresistive OEM Pressure Sensor

PRODUCT CATALOGUE DIGITAL GAUGES

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

American Sensor Technologies. Your Sensor Business Partner...

American Sensor Technologies. Your Sensor Business Partner...

Electronic relative and differential pressure switch type 616

! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible

PC12K Flush Diaphragm Pressure Sensor with Clamp

Climatic Independent Level Sensor LAR

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

Differential Pressure Transmiter

MANUAL KPS Pressure Control Valve

Prewired position switches FA series

Pressure Measurement Single-range transmitters for general applications

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

MDM490 Piezoresistive Differential Pressure Transmitter

ASDX Series Silicon Pressure Sensors

Datasheet May, 2017 HPSD 4000 Pressure Transducer 1/5. Applications

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Additel 780 Series Pressure Controller

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Gas density monitor With integrated transmitter Model GDM-100-TI

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

ellison sensors international

Position switches FP series

Mass Flow Meter (MFM) for gases

2/2-Way Proportional Valve (motor-driven)

3.0 Pressure Transmitter Selection

QBS Electronic Control Valve

AMS 2710 PCB pressure sensor module with V output

L3 Pressure and Level transmitter

Modbus Submersible Level Transducer

Transcription:

Small size with amplified output Any liquid or gas media compatible with stainless steel Operating temperature up to 150 C (300 F) Variety of pressure ports Available as gage and absolute CE approved DESCRIPTION Miniature pressure transducer, 100% stainless steel welded construction with amplified output, designed for severe environment where minimum size and weight are required. FEATURES APPLICATIONS Liquid and gas media compatible with SS Motorsports Ranges from 0.35 to 700 bar (5 to 10,000 PSI) Downhole Exploration Operating temperature up to 150 C (300 F) Off-Road Vehicles Combined NL & H ± 0.25% Pipeline Pressures STANDARD RANGES Pressure ranges Pressure Reference Pressure Overload (rated pressure) Burst Pressure (rated pressure) gage* abs. (BAR) (PSI) (type1) (type3) 0.35 5 3 x FS 5 x FS 0.6 10 3 x FS 5 x FS 1 15 3 x FS 5 x FS 2 30 3 x FS 5 x FS 3.5 50 2 x FS 3 x FS 6 100 2 x FS 3 x FS 10 150 2 x FS 3 x FS 20 300 2 x FS 3 x FS 35 500 2 x FS 3 x FS 60 1K 2 x FS 3 x FS 100 1.5K 2 x FS 3 x FS 200 3K 2 x FS 3 x FS 350 5K 2 x FS 3 x FS 700 10K 1.5 x FS 2 x FS * Gage model (type 1) is vented to atmosphere through one hole into sensor housing (sensor to be used into dry and clean environment) 1/5

PERFORMANCE SPECIFICATIONS All values are typical at temperature 20± 1 C Supply Voltage Max Current PARAMETERS VALUES NOTES Non-Repeatability CNL & H Long term stability Bandwidth (-3 db) Thermal Zero Shift "TZS" Thermal Sensitivity Shift "TSS" Operating Temperature Version U: 8 to 32VDC ; Version R: 5 VDC reg. < 10 ma ± 0.05% FSO typ. ± 0.25% FSO Offset = 0.1%span/year ; Span = 0.1%/year 400 Hz ± 1%FSO /100 C (±2% FSO/100 C for ranges 1 bar or 15 psi) ± 1% /100 C (±1.5% /100 C for ranges 1 bar or 15 psi) - 40 C to 150 C Compensated Temperature 0 C to 100 C See option f or other Temperature Output FSO Zero Offset at 23 C Vibration Shock (1/2 sine) Weight (without cable) Type 3: 0.5 to 4.5V = 4V ± 50mV Type 6: 0 to 5V = 5V ± 50mV Type 3 available on version R and U Type 6 available on version U only Type 3 = 0.5V ± 50mV (0.5V ±100mV for ranges 1 bar or 15 psi) Type 6 = ± 50mV (± 50mV ±100mV for ranges 1 bar or 15 psi) 2g (10Hz to 60Hz) and 20g (60Hz to 1 KHz) 50g (11 ms) and 200g (6 ms) 20 g + 25 g per meter of cable Ingress Protection IP66 IP30 for vented gage model (type 1) CE compliance EN55022 Emissions Class A & B IEC61000-4-2 Electrostatic Discharge Immunity (1kV contact) IEC61000-4-3 EM Field Immunity (3V/m) IEC61000-4-4 Electrical Fast Transient Immunity (1kV) 2/5

DIMENSIONS STANDARD EPRB-2 WITH SHIELDED CABLE OUTPUT (standard length = 1m) O'RING 3x O 1,2.047 x120 "C" Thread "A" ø 15.591 "B" 20,6.811 PHYSICAL MODEL THREAD A THREAD LENGTH "B" DIM. C O-RING SUPPLIED INSTALLATION TORQUE (MAX.) N M5X0.8 8.2 (.323 ) 15 mm (.590 ) Ø3.5x1.5 FKM Fluoroelastomer 1 Nm (2 Nm max.) V 10-32 UNF-2A 8.2 (.323 ) 15 mm (.590 ) Ø3.5x1.5 FKM Fluoroelastomer 1 Nm (2 Nm max.) S M8X1 8.2 (.323 ) 15 mm (.590 ) Ø6.35x1.6 FKM Fluoroelastomer 2.5 Nm (5 Nm max.) Q 5/16-24 UNF-2A 8.2 (.323 ) 15 mm (.590 ) Ø6.35x1.6 FKM Fluoroelastomer 2.5 Nm (5 Nm max.) P M10X1 8.2 (.323 ) 15 mm (.590 ) Ø7.65x1.63 FKM Fluoroelastomer 3 Nm (6 Nm max.) X 3/8-24 UNF-2A 8.2 (.323 ) 15 mm (.590 ) Ø7.65x1.63 FKM Fluoroelastomer 3 Nm (6 Nm max.) Z 7/16-20 UNF-2A 8.2 (.323 ) 18 mm (.71 ) Ø8.92x1.83 NBR 5 Nm (10 Nm max.) W G 1/4A (BSP) 11.7 (.460 ) 18 mm (.71 ) Not Supplied 5 Nm (10 Nm max.) Y ¼ -18 NPT 14 (.551 ) 18 mm (.71 ) Not Supplied 5 Nm (10 Nm max.) INSTALLATION & CONNECTION RECOMMENDED MOUNTING PORT Thread A Dim. B Dim. C Dim. D M5X0.8 5.6 mm 1.5 mm 0.2 mm 10-32 UNF 0.22 0.06 0.01 M8x1 8.8 mm 1.9 mm 0.4 mm 5/16-24 UNF 0.35 0.075 0.015 M10x1 10.4 mm 2.0 mm 0.4 mm 3/8-24 UNF 0.41 0.077 0.015 7/16-20 UNF 0.48 0.086 0.015 Tolerances on dimensions = ± 0.05 mm (0.002 ) 3/5

WIRING: shielded cable (4 x AWG26) Output signal type 3 (-Output and -Input are common) Output signal type 6 and 8 (VCM = 0.5 V from -Output to -Input) CONNECTOR OUTPUT OPTIONS Option CM1(connector recommended for Mil-Aero applications): integral connector Deutsch DCS11T8-7PN Mating connector DCS07T8-7SN not supplied Pin number EPRB-2-/CM1 1 & 3 -INPUT 2 not used 4 +OUPUT 5 -OUPUT 6 not used 7 +INPUT Option CM2: integral connector MIL-C 26482 MS3113H10-6P (limited to operating temperature 125 C) Mating connector 85106J06S50 not supplied Pin name A B C D E F EPRB-2-/CM2 +INPUT +OUTPUT -OUTPUT -INPUT not used not used See following table to order mating connector with wired shielded cable 4 leads AWG26 (to be used with CM2) Cable length Reference 1 meter ECS-CM2-/L1M 3 meter ECS-CM2-/L3M 5 meter ECS-CM2-/L5M 10 meter ECS-CM2-/L10M 4/5

OPTIONS AND ACCESSORIES OPTIONS CODES DESCRIPTIONS Compensated Temperature Ranges Z1 Z35-20 C to 40 C +20 C to 120 C Special Cable Length (standard = 1 m) L00M Replace 00 with total length in meters (L3M ; L5M ; L10M ) Integral connector CM1 or CM2 See drawings page 4 Acceptance Test Report ATR A complete Acceptance Test Report provided with transducer ORDERING INFORMATION Model - Pressure Port Supply Voltage Output Signal Pres. Ref. - Range/Unit - Options EPRB-2 - N = M5x0.8 V = 10-32 UNF S = M8x1 Q = 5/16-24 UNF P = M10x1 X = 3/8-24UNF Z = 7/16-20 UNF W = G 1/4A Y = ¼-18 NPT U = 8 to 32 VDC R = 5 VDC reg. 3 = 0.5 to 4.5 V 6 = 0 to 5 V 1 = Gauge 3 = Absolute - 0.35B 0.6B 1B 2B 3.5B 6B 10B 20B 35B 60B 100B 200B 350B 700B 5P 10P 15P 30P 50P 100P 150P 300P 500P 1KP 1.5KP 3KP 5KP 10KP - /Z1 /Z35 /L00M /CM1 /CM2 /ATR Example: EPRB-2-XU63-500P-/Z1/L5M (cable output) or EPRB-2-PR33-35B-/CM2/ATR (connector output) The psi range models are only supplied with imperial thread design. The bar range models are only supplied with metric thread design. The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others.