Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Similar documents
Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type BBS-03, BBS-05, BBS-06, BBS-25

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type C-CUT. Quickstart. English Deutsch Français

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

4/2 way Pneumatic Solenoid Valve

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Type 2030, 2031, 2031 K, 2032, 2033, 2037

OPERATION MANUAL PNEUMATIC VALVES

Dual Solenoid Gas Valve Installation

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Declaration of Conformity as per Directive 97/23/EC

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Operation Manual Air Saver Unit ASV5000 Series

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Solenoid valves VZWF, force pilot operated

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Operating Instructions

Declaration of Conformity as per Directive 97/23/EC

Operating Instructions

GM-7000 Series CE Approved Gas Control Valve

D62 - D63 Directional Control Valve l/min

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

BGA158 Series CE Approved Class A Shutoff Gas Valve

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

DK46 - DK800 Supplementary instructions

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Declaration of Conformity as per Directive 97/23/EC and Manufacturer s Declaration as per Directive 98/37/EC

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 06.

Safety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION Elster GmbH Edition 01.15

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

BGA158 Series CE Approved Class B Shutoff Gas Valve

Safety. Operating instructions Manual valves AKT, flow adjusting cocks GEHV, GEH, LEH DANGER. Contents WARNING CAUTION. Changes to edition 03.

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Declaration of Conformity as per Directive 97/23/EC

2/2-Way Solenoid Control Valve

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

BGC258 Series BASOTROL Gas Valve

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Inverted Bucket Steam Trap IB 16A-7

Siphon vessel / Priming aid

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Safety. Operating instructions. White meters BK V2 to BK V12. (component of a diaphragm gas meter) DANGER. Contents WARNING CAUTION

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range

3-Way Safety Block DSV

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

Steam trap BK 37 BK 28 BK 29 BK 37 ASME BK 28 ASME BK 29 ASME

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Pressure relief valve

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Installation and Operating Instructions Bypass Flow Meter DST

G96 Series BASOTROL Dual Operator Valve

for the of and the EM55-1

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Safety. Operating instructions Gas pressure regulators 60DJ, J78R, GDJ DANGER WARNING. Contents CAUTION Edition 12.10

Valvex Valves for Mining Applications

Instruction Manual Contact Pressure Vacuum Gauge

Proportional Throttle Cartridges, Size 16

Pressure relief valve

Non-Return Valve SRK 22A

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

MAINTENANCE AND OPERATING MANUAL

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

SILENTAIRE TECHNOLOGY

OPERATION MANUAL NTF-15

Pressure maintenance valve SDV-P / SDV-P-E

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATORS OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY GLOSSARY OF SYMBOLS. : ON (power switched on)

Flowmeter. Original operating manual DFM

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

OPERATION MANUAL NTF-60 Plus

Electro-Pneumatic Converter YT-940 SERIES

USER MANUAL. MACMAG magnetic separator MHK MHF

USER MANUAL SAVE THESE INSTRUCTIONS. 300 Held Drive Tel: (+001) Northampton, PA USA Fax: (+001) ISO Certified

Actuating elements for ComEx

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

Pressure Limiting Valve SPVF Operating Instructions

Type 4708 Supply Pressure Regulator

Transcription:

Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

1 OPERATING INSTRUCTIONS The operating instructions contain important information. Read the operating instructions carefully and follow the safety instructions in particular, and also observe the operating conditions. Operating instructions must be available to each user. The liability and warranty for the device are void if the operating instructions are not followed. 1.1 Symbols Designates an instruction to prevent risks. designates a procedure which you must carry out. Warning of injuries: DANGER! Imminent danger! Serious or fatal injuries. WARNING! Potential danger! Serious or fatal injuries. CAUTION! Danger! Minor or moderately severe injuries. Warns of damage to property: NOTE! 2 INTENDED USE Incorrect use of the solenoid valve Type 0404 and 5404 can be dangerous to people, nearby equipment and the environment. The device is designed to control, shut off and meter neutral media up to a viscosity of 21 mm 2 /s. The device may only be used in the explosion-protected area if an appropriate additional identification is attached to the type label. For use observe the additional information enclosed with the device together with safety instructions for the explosion risk area. Devices without a separate Ex type label may not be used in a potentially explosive area. Provided the cable plug is connected and installed correctly, e.g. Bürkert Type 2508, the device satisfies protection class IP65 in accordance with DIN EN 60529 / IEC 60529. Use according to the permitted data, operating conditions and conditions of use specified in the contract documents and operating instructions. Correct transportation, correct storage and installation and careful use and maintenance are essential for reliable and problem-free operation. Use the device only as intended. 2

2.1 Restrictions If exporting the device, observe any existing restrictions. 2.2 Definition of term In these operating instructions, the term device always refers to the solenoid valve Type 0404 and 5404. 3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contingencies and events which may arise during installation, operation and maintenance. Danger high pressure! Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of electric shock! Before reaching into the system, switch off the power supply and secure to prevent reactivation! Observe applicable accident prevention and safety regulations for electrical equipment! Risk of burns/risk of fire if used continuously through hot device surface! Keep the device away from highly flammable substances and media and do not touch with bare hands. 3

Risk of injury due to malfunction of valves with alternating current (AC)! Sticking core causes coil to overheat, resulting in a malfunction. Monitor process to ensure function is in perfect working order. Risk of short-circuit/escape of media through leaking screw joints! Ensure seals are seated correctly. Carefully screw valve and connection lines together. General hazardous situations. To prevent injury, ensure that: Do not make any internal or external changes. Ensure that the system cannot be activated unintentionally. Installation and repair work may be carried out by authorized technicians only and with the appropriate tools. After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. Do not put any loads on the body. The general rules of technology apply to application planning and operation of the device. For models with ATEX or UL approval follow the safety instructions in the ATEX manual and on the respective supplementary sheet. 3.1 Warranty The warranty is only valid if the device is used as intended in accordance with the specified application conditions. 3.2 Information on the internet The operating instructions for type 0404 and 5404 can be found on the internet at: www.burkert.com Type 0404 / 5404 4

4 TECHNICAL DATA 4.1 Operating conditions The following values are indicated on the type label: Voltage (Tolerance ± 10 %) / Current type Coil power consumption (active power in W - at operating temp.) Pressure range Body material: Brass (MS) Sealing material: PTFE/NBR (EB), PTFE/FKM (EF) Special instructions for valves circuit function B (NO) with deaeration connection G1/8 on the coil (CF05): The deenergized valve is open. The medium also flows off via the deaeration connection on the coil. Valves of this design are therefore suitable for relieving compressors only. Circuit function 2/2-way valve: A (NC) B (NO) 4.2 Conformity In accordance with the EC Declaration of conformity, the solenoid valve Type 0404 and 5404 is compliant with the EC Directives. Protection class: IP65 in accordance with DIN EN 60529 / IEC 60529 with cable plug, e.g. Bürkert Type 2508 4.3 Standards The applied standards, which verify conformity with the EC Directives, can be found on the EC-Type Examination Certificate and / or the EC Declaration of Conformity. 5

4.4 Application conditions Ambient temperature: max. +55 C Permitted medium temperature depending on coil material and sealing material: Coil material Type Sealing material Medium temperature Polyamide 5404 PTFE/NBR (EB) 0 - +100 C Polyamide 5404 PTFE/FKM (EF) 0 - +100 C Epoxide 0404, 5404 PTFE/NBR (EB) 0 - +100 C Epoxide 5404 NA38 PTFE/FKM (EF) 0 - +120 C The following values must also be observed for valves with UL/ UR approval: Fluid Temperature Fluid Ambient Non-hazardous air, inert gas -10...+110 C -10...+55 C fluids water 0...+100 C 0...+55 C Hazardous fluids oxygen -10...+60 C -10...+55 C (var. code NL02) No.2 fuel oil -10...+110 C -10...+55 C Operating duration: Unless otherwise indicated on the type label, the solenoid system is suitable for continuous operation Important information for functional reliability during continuous operation: If standstill for a long period at least 1-2 activations per day are recommended. Service life: High switching frequency and high pressures reduce the service life 6

Permitted media depending on sealing material: Sealing material PTFE/NBR PTFE/FKM 1) special design only 4.5 Type label Orifice Circuit function Type Made in Germany Id. Number 5404 A 12,0 EB MS G1/2 P N 1-50 bar 230 V 50 Hz 8W Permitted media Neutral media such as compressed air, water, hydraulic oil Oxygen 1), hot air, hot oils, oils with additives, Per solutions 00134593 W12MN Sealing material Body material Connection thread, Operating pressure Voltage, Frequency, Power consumption Manufacturer code 5 INSTALLATION 5.1 Safety instructions DANGER! Risk of injury from high pressure in the equipment! Before loosening the pipes and valves, turn off the pressure and vent the lines. Risk of injury due to electrical shock! Before reaching into the device or the equipment, switch off the power supply and secure to prevent reactivation. Observe applicable accident prevention and safety regulations for electrical equipment. WARNING! Risk of injury from improper installation! Installation may be carried out by authorized technicians only and with the appropriate tools. Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following assembly, ensure a controlled restart. 7

5.2 Before installation Installation position: any, actuator preferably upwards. Procedure: Check pipelines for dirt and clean. Install a dirt filter before the valve inlet ( 500 µm). 5.3 Installation NOTE! Caution risk of breakage! Do not use the coil as a lever arm. Hold the device using a suitable tool on the body and screw into the pipeline. Valve body must not be installed under tension. Sealing material must not get into the device. Observe direction of flow: The arrow on the body indicates the direction of flow. 5.4 Electrical connection of the cable plug WARNING! Risk of injury due to electrical shock! Before reaching into the system, switch off the power supply and secure to prevent reactivation. Observe applicable accident prevention and safety regulations for electrical equipment. If the protective conductor is not connected, there is a risk of electric shock! Always connect protective conductor and check electrical continuity between coil and body. Procedure: Tighten cable plug (e.g. Type 2508 or other suitable cable plug), observing max. torque 1 Nm. Check that seal is fitted correctly. Connect protective conductor and check electrical continuity between coil and body. 8

Authorized cable plug e.g. Type 2508 or other suitable cable plug in accordance with DIN EN 175301-803 Form A Seal max. 1 Nm 6 MAINTENANCE, TROUBLESHOOTING 6.1 Safety instructions DANGER! Risk of injury from high pressure in the equipment! Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of injury due to electrical shock! Before reaching into the system, switch off the power supply and secure to prevent reactivation! Observe applicable accident prevention and safety regulations for electrical equipment! WARNING! Risk of injury from improper maintenance! Maintenance may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart! Secure system from unintentional activation. Following maintenance, ensure a controlled restart. 9

6.2 Malfunctions If malfunctions occur, check whether: the device has been installed according to the instructions, the electrical and fluid connections are correct, the device is not damaged, all screws have been tightened, the voltage and pressure have been switched on, the pipelines are clean, the power supply is adequately high. Possible cause if the valve does not switch: Short circuit or coil interrupted. Inadequate power supply. Core or core area dirty. Medium pressure outside the permitted pressure range. Possible cause if the valve does not close: Internal space of the valve is dirty. 7 SPARE PARTS CAUTION! Risk of injury and/or damage by the use of incorrect parts! Incorrect accessories and unsuitable spare parts may cause injuries and damage the device and the surrounding area. Use only original accessories and original spare parts from Bürkert. 7.1 Ordering spare parts The following spare parts are available for the solenoid valve Type 0404 and 5404: Coil set (Pos. 1) Wearing parts set pilot control (Pos. 2) Wearing parts set fitting (Pos. 3) Order the spare parts sets quoting the positions and the identification number of the device. 10

7.2 Overview of spare parts Type 0404 Type 5404 1 1 2 2 3 3 8 TRANSPORT, STORAGE, DISPOSAL NOTE! Transport damages! Inadequately protected equipment may be damaged during transport. During transportation protect the device against wet and dirt in shock-resistant packaging. Avoid exceeding or dropping below the allowable storage temperature. Incorrect storage may damage the device. Store the device in a dry and dust-free location! Storage temperature -40 - +80 C. Damage to the environment caused by device components contaminated with media. Dispose of the device and packaging in an environmentally friendly manner. Observe applicable regulations on disposal and the environment. 11

Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940-10 91 111 Fax + 49 (0) 7940-10 91 448 E-mail: info@burkert.com International address www.burkert.com Manuals and data sheets on the Internet: www.burkert.com Bedienungsanleitungen und Datenblätter im Internet: www.buerkert.de Manuel d'utilisation et fiches techniques sur Internet : www.buerkert.fr Bürkert Werke GmbH & Co. KG, 2014-2017 Operating Instructions 1705/14_EU-ML_00803350 / Original DE www.burkert.com