ERTC PETROCHEMICAL Conference 20 st -22 nd February 2002, Amsterdam, The Netherlands

Similar documents
Liquid -Vapor. Contacting columns

I. Nieuwoudt, O. Karpilovskiy and M. J. Lockett, Koch-Glitsch LP, USA,

Distillation Design The McCabe-Thiele Method

DISTILLATION POINTS TO REMEMBER

Module # 8 DISTILLATION AND ABSORPTION COLUMN

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

Analysis and Modeling of Vapor Recompressive Distillation Using ASPEN-HYSYS

CHE 306 Stagewise Operations

Structured packing use in fluid catalytic cracker (FCC)

DSTWU A Shortcut Distillation Model in Aspen Plus V8.0

Removing nitrogen. Nitrogen rejection applications can be divided into two categories

Development of a High Pressure, Oil Free, Rolling Piston Compressor

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Manual for continuous distillation

PETROLEUM & GAS PROCESSING TECHNOLOGY (PTT 365) SEPARATION OF PRODUCED FLUID

By: Eng. Ahmed Deyab Fares - Mobile:

FlashCO2, CO2 at 23 $/ton

Fast-tracking an FCC Revamp

INNOVATIVE GAS-LIQUID SEPARATOR INCREASES GAS PRODUCTION IN THE NORTH SEA

A NEW PROCESS FOR IMPROVED LIQUEFACTION EFFICIENCY

CHE 4115 Chemical Processes Laboratory 2 Experiment 1. Batch Distillation

INTEROFFICE MEMORANDUM MODIFICATIONS TO DEW POINT CONTROL PROCESS

DISTILLATION COLUMN PROCESS CONTROL STRATEGIES

Title: Choosing the right nitrogen rejection scheme

A Financial Analysis for the Recovery of High Purity Propylene from Refinery LPG R.E. (Ed) Palmer Ian M. Glasgow

Optimal Operation of Dividing Wall Column using Enhanced Active Vapor Distributor

Dynamic Simulation for T-9 Storage Tank (Holding Case)

Simplicity in VRU by using a Beam Gas Compressor

2. Determine how the mass transfer rate is affected by gas flow rate and liquid flow rate.

Structure Study of Internal Thermally Coupled Distillation Columns

Single- or Two-Stage Compression

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Technical Bulletin 148. Comparison of Flat Panel to MiniPanel. by:

Dynamics and Control of Chemical Processes Solution to Lab #8 Shutdown of C4-C5 separation section

Separation of Acetone-Water with Aspen HYSYS V8.0

TABLE OF CONTENT

STANDARD HIGH PRESSURE COMPRESSORS COMPACT PACKAGE FOR DEMANDING APPLICATIONS

Training Title IDENTIFY OPERATIONAL UPSETS, REVIEW & VALIDATE IN OIL & CHEMICAL PLANTS

Column Design Using Mass Transfer Rate Simulation

Computer Simulation Helps Improve Vertical Column Induced Gas Flotation (IGF) System

Separation Columns (Distillation)

Ammonia Synthesis with Aspen Plus V8.0

S-CO 2 Brayton Recompression Loop Design and Control

CRYSTALLIZATION FOULING IN PACKED COLUMNS

PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Application of CFD for Improved Vertical Column Induced Gas Flotation (IGF) System Development

Free Surface Flow Simulation with ACUSIM in the Water Industry

Tradition & Technology

High Efficiency SO2 Scrubber Design to Reduce Caustic Consumption

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Development of TEU Type Mega Container Carrier

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Redesign of Centrifugal PLACE FOR Compressor TITLE. Impeller by means of Scalloping

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

Inflatable Standing Aid Device

Improving distillation tower operation

Peerless TECH SPEC FOR HIGH-EFFICIENCY, HIGH-CAPACITY, AND LOW-COST GAS AND LIQUID SEPARATION

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Structure of Mechanically Agitated Gas-Liquid Contactors

TechTalk. Purging for Delayed Coking. Understanding purging system design in heavy-fouling applications. Outline

DISTILLATION PRESSURE CONTROL TROUBLESHOOTING THE HIDDEN PITTFALLS OF OVERDESIGN

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

VERTICAL BLADDER TANK

Liquefied gas cargo tanks and process pressure vessels

MODEL PREDICTIVE CONTROL OF INTEGRATED UNIT OPERATIONS CONTROL OF A DIVIDED WALL COLUMN

POWER Quantifying Correction Curve Uncertainty Through Empirical Methods

Pressurised Oxygen Supply for CO 2 Capture Applications

Vibration and Pulsation Analysis and Solutions

Efficiency Benefits of High Performance Structured Packings

Hydraulic Modeling to Aid TDG Abatement at Boundary and Cabinet Gorge Dams

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

HORIZONTAL BLADDER TANK

MIXED-PHASE FEEDS IN MASS TRANSFER COLUMNS AND LIQUID SEPARATION

Structural Design of Tank Weighing Systems

Using P-T Analysis As A Service Tool

A NOVEL APPROACH TO ETHANE REFRIGERANT EXTRACTION FOR GREENFIELD LNG PLANTS

SUPERSONIC GAS TECHNOLOGIES

Workshop 302-compressor-anti-surge

making energy safe, efficient and clean FOR HIGH-EFFICIENCY, HIGH-CAPACITY, COST EFFECTIVE GAS AND LIQUID SEPARATION HORIZONTAL SEPARATOR

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

Multivariable Predictive Control and its Application on the Solvent Dehydration Tower

Enhancing Thermodynamic Efficiency of Energy Intensive Distillation Columns via Internal Heat Integration *

The Criticality of Cooling

Inprocess Operator Training Programme

Drilling Efficiency Utilizing Coriolis Flow Technology

Energy Output. Outline. Characterizing Wind Variability. Characterizing Wind Variability 3/7/2015. for Wind Power Management

Efficiency and Control of a Heat Integrated Distillation Column (HIDiC)

1.2 Example 1: A simple hydraulic system

COMPRESSED AIR DISTRIBUTION SYSTEMS

Compressors. Basic Classification and design overview

DEHYDRATION OF ACID GAS PRIOR TO INJECTION Eugene W. Grynia, John J. Carroll, Peter J. Griffin, Gas Liquids Engineering, Calgary, Canada

Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )

Aalborg Universitet. Published in: Proceedings of Offshore Wind 2007 Conference & Exhibition. Publication date: 2007

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Red Valve Coarse and Fine Bubble Air Diffuser Systems

PEPSE Modeling of Triple Trains of Turbines Sending Extraction Steam to Triple Trains of Feedwater Heaters

CFD Analysis and Experiment Study of the Rotary Two-Stage Inverter Compressor with Vapor Injection

Autodesk Moldflow Communicator Process settings

Transcription:

Reprint from Presentation at ERTC PETROCHEMICAL Conference 20 st -22 nd February 2002, Amsterdam, The Netherlands and ARTC PETROCHEMICAL Conference 11 th 13 th March 2002, Bangkok, Thailand Sulzer Chemtech, March 2002 Page 1 of 14

DESIGN AND REVAMP OF MODERN C2 SPLITTERS USING HIGH CAPACITY INTERNALS AND FAST INSTALLATION TECHNIQUES Jose L. Bravo, Jan Sikkenk, Shell Global Solutions International, Amsterdam, NL Mario Roza, Loris Tonon, Sulzer Chemtech, Winterthur, CH For Presentation at the ERTC Petrochemical Meeting in Amsterdam (NL), 20 22 February 2002 ABSTRACT Two factors are key in successfully implementing revamps of olefins distillation trains: a) Effective increase in column productivity by increasing hydraulic capacity and separation efficiency. b) Fast turnaround times during installation. The use of High Capacity trays in these cases can provide the first but to ensure the second one needs to apply specialized designs and installation techniques. This paper describes first the technology available today to revamp ethane/ethylene splitters with high performance trays at various tray spacings. The discussion will cover items such as process simulation, plates vs. reflux effects, tray capacity and efficiency, and the importance of other internals such as distributors for flashing feeds. Consideration is given to a balance between number of trays in the column and the capacity needed. A discussion of specific design requirements for low pressure heat-pumped strippers vs. higher pressure ones will also be presented in the context of how high performance column internals can reduce or eliminate the need for heat pump revamp in many cases. The second part of the paper will discuss mechanical design features that need to be incorporated into high performance trays that allow for fast installation in revamp conditions and the impact this could have on project economics. An example of a successful revamp using these concepts will be presented as well to illustrate their application. Page 2 of 14

Typical C2 Splitter Designs Two kinds of C2 splitters can be commonly found in olefins plants: a) Low Pressure C2 Splitters with heat pump or refrigeration b) High Pressure C2 Splitters The low pressure configuration is a more energy efficient and often also capital efficient one but requires special equipment to be able to condense the overhead vapors. High pressure C2 splitters normally require more stages for separation and much higher reflux/feed ratios but can condense overheads in a more conventional manner. Normally the ethylene produced overhead will have a purity of 99.9%, and a recovery in excess of 99% and occasionally close to 99.9% with respect to the ethylene in the feed. Higher recovery splitters are normally configured in the low pressure mode. For example, a typical low pressure C2 splitter will produce specification ethylene, with 99.9% recovery with a feed as high as 85% ethylene and a bottoms propane stream with about 0.5% ethylene. Conversely, a high pressure stripper could yield specification ethylene with a feed, of say, 59% olefin. The ethane stream leaving the bottom in this case will have less than 1.5%. Plates vs. Reflux for C2 Splitters As is the case with all binary separations, a plates vs. reflux curve can be constructed for each specified separation and pressure. This curve clearly indicates the minimum number of stages and the minimum reflux required for separation and the design point will fall between these two extremes. Of note is that the feed location also has an important effect on these curves. Figure 1 represents such a curve for a low pressure C2 splitter. It clearly indicates that lower pressures are conducive to lower reflux requirements and lower required number of stages. This is of prime importance in revamps since the ability to increase reflux is often limited by the heat pump or refrigeration limits as the case may be. There is great value in being able to increase C2 splitter capacity without increasing reflux/feed ratio and in some cases reducing it. The first Page 3 of 14

variable to look at in this case will be column pressure. If the column has say 80 theoretical stages or more, then pressure is the only variable to manipulate to try to reduce reflux/feed ratio. 4 Figure 1.- Plates vs Reflux for Low Pressure C2 Splitter Feed with 85% ethylene, top product with 99.9% ethylene, bottoms product with 0.3% ethylene, feed stage 70% counting from top 3.5 Reflux/feed ratio 3 2.5 12 bar top Pressure 10 bar top Pressure 8 bar top Pressure 7 bar top Pressure 2 1.5 20 40 60 80 100 120 140 160 Number of stages (NTS) Figure 2 indicates that high pressure splitters exhibit the same characteristics as described above but that the required reflux/feed ratios are generally much higher as are the number of theoretical stages required to perform the separation. In this case though, making more reflux in case of a revamp is less complicated since it may not involve changes to refrigeration compressors or heat pumps. The incentive thus to go to lower pressures in revamps might seem less pronounced. Page 4 of 14

Figure 2.- Plates vs Reflux for High Pressure C2 Splitter Feed with 59% ethylene, top product with 99.9% ethylene, bottoms product with 1.4% ethylene, feed stage 75% counting from top 4.5 Reflux/feed ratio 4 3.5 3 2.5 20 bar top Pressure 24 bar top Pressure 2 0 50 100 150 200 Number of stages Capacity of Trayed C2 Splitters The discussion above indicates that lower pressure in C2 splitters yields lower reflux requirements for a fixed number of stages. On the other hand, lower pressure frequently leads to a hydraulic limitation for tray operation, especially in the case of C2 splitters that are commonly limited by jet or entrainment flood and not by liquid handling capacity. In these cases, the low pressure results in higher vapor velocities in the column that leads to flooding. The analysis of a revamp then becomes a comparison between the beneficial effects of pressure reduction with respect to reflux reduction versus, the negative effects of lower pressure on tray capacity. In the cases where lowering the pressure is mandated by the limitations of the heat pump or refrigeration system, then the use of high capacity trays is of great benefit. Figure 3 is an illustration as to how the splitter characterized in Figure 1 previously is affected by changes in pressure when looking at a revamp situation (column diameter and total length are fixed meaning the fewer stages have more tray spacing and more stages require less tray spacing). Note that the vertical axis shows the fraction of the maximum capacity of the existing column and as such, a lower number means that the column has that much more room. Page 5 of 14

In this case one can clearly see that a revamp at 7 bar is impossible in the existing column since jet flood will limit the capacity severely. The top curve shows how even as the reflux rate is reduced, the increased vapor velocity caused by the low pressure overcomes this benefit. The ideal combination for this case is probably 8 bar since it produces the maximum available extra capacity (lowest % maximum capacity) and the lowest reflux/feed ratio requirements. Figure 3 also indicates that having more than 80 stages in the column is fruitless. Figure 3.- Effects of Pressure and Number of Trays on Capacity of Low Pressure C2 Splitter 100 % Maximum capacity for a fixed diameter 95 90 85 80 75 70 65 20 40 60 80 100 120 140 160 NTS in a fixed column height 12 bar top Pressure 10 bar top Pressure 8 bar top Pressure 7 bar top Pressure To maximize the column ability one needs to look at high capacity trays that maximize jet flood capacity by the use of trays with maximum bubbling area and effective bubblers. The Shell Calming Section (CS) and HiFi Plus trays combine such features by using truncated downcomers with perforations underneath that maximize bubbling area and by applying Sulzer MVG valves as bubblers that produce markedly less entrainment. Figure 4 shows the same analysis but for the high pressure splitter described above in Figure 2. In this case the choice is clear, the lower pressure gives the advantage of maximum capacity for the overall system. It is interesting to note that in this case, the 24 bar case has such a Page 6 of 14

detrimental effect on volatility that the reflux requirements become extremely high making this an unworkable pressure. Figure 4.- Effects of Number of Trays and Pressure on Capacity of a High Pressure C2 Splitter 90 % Maximum capacity for a fixed diameter 80 70 20 bar top Pressure 24 bar top Pressure 60 0 50 100 150 200 NTS in a fixed column height High Capacity Trays for C2 Splitters As mentioned above, revamps of C2 splitters for higher capacity can effectively take advantage of high capacity tray technology. In particular, the use of trays that increase jet flood capacity at high pressure can be very interesting. Tray features that increase jet flow capacity are, among others: a) Truncated downcomers that allow for perforation underneath leading to larger bubbling areas. b) Bubblers such as small fixed valves that reduce entrainment. c) Devices at the inlet and outlet of downcomers that produce a lower and more uniform froth height. Figure 5 demonstrates the effectiveness of these features in enhancing the capacity of trays. The vertical axis represents the relative jet flood capacity whereas the horizontal axis, the Flow Page 7 of 14

Parameter, is an indication of liquid load and pressure. C2 Splitters are typically found in the Flow Parameter range of 0.1 to 0.3. Figure 5. - Relative Jet Flood Capacity of Various Tray Devices 1.50 Relative jet flood capacity 1.25 1.00 0.75 0.50 0.25 Sieve MVG CS / HiFi Plus 0 0 0.2 0.4 0.6 0.8 Flow Parameter The graph compares the capacity of a sieve tray with that of the same tray with MVG valves. The upper set of points represents the performance of the HiFi or CS Plus trays that include the MVG valves as well as other features to stabilize the froth on the tray. Clearly the MVG adds 10-20% capacity and the other feature adds an additional 10-20% as well depending on the tray regime. Page 8 of 14

Construction and Installation Considerations for fast Revamps of Tray Columns The critical path for a shutdown involving extensive modifications to C2 and other splitter columns as described above is often determined by the installation time of the new internals. The number of days involved in a shutdown can have a very large impact on the profitability of a revamp. It is therefore of extreme interest to look carefully to the installation techniques applied for new trays and how they can reduce the required time. Once a modification to the column is established, there is little one can do to achieve any major time savings in the dismounting and removal phase of the old internals. Careful planning of such work on several levels in the column with manhole access and coordination of removal of old trays and associated internals and supports is necessary to optimize the dismounting time. When a different number of trays than originally installed in the column have to be applied, new support structures have to be foreseen for these additional trays. New tray rings and bolting bars that have to be welded normally lead to time consuming hot work and associated risks. Furthermore, stress relief for columns operating at high pressure has to be performed if welds to the column wall are necessary. In all cases, pressure tests of the column shell and nozzles need be done if new penetrations are specified Finally it is important that the new trays can be installed very quickly and where possible in parallel on as many levels as possible. This means that the number of parts and requirement for bolted connections should be reduced to a minimum. Sulzer Chemtech has developed a number of techniques that avoid welding to the column wall and bolting of tray panels when installing trays ad different trays spacings than prior to a revamp. They are described below Page 9 of 14

Reducing Installation Time with Special Tray Design Features The unique Lip-Slot panel connection as seen in Figure 6 eliminates the need for bolting along the trusses of adjacent tray panels. The time required to fasten panels to each other when using this type of connection once inside and at the tray location is reduced to practically zero. Only the last panel or the manway in most cases at or around the center of the column is bolted or connected with the wedge type connections described hereafter. Figure 6. Lip-Slot connection, 3D sketch and photo Lip-Slot connections have been successfully used in the most diverse applications in the HPI field. Special comparative third party studies have been made showing superior mechanical strength of Lip-Slot panel connections compared to bolted panels. Only in those rare cases, where strong vibrations are expected due to wildly varying vapor loads bolted connections are preferred. Split-wedge type tray support ring and downcomer connections (Figure 7a) also eliminate the need for bolting. After installation the wedges are secured by bending them out. They have also been subject to extensive comparative testing with the usual bolted tray clamp (Figure 7b). They are standard for all Shell fractionation trays for both the downcomer and for the tray support ring connection. They can also be used for conventional trays. Page 10 of 14

Figure 7a. Wedge type connection Figure 7b. Bolted clamp The Sulzer MVG fixed valves (Figure 8) are a good alternative for moving valves. They offer a significantly higher capacity while having nearly the good turndown characteristics. They also offer a large advantage from a handling point of view during and installation. Whereas panels with moving valves are easily damaged and have to be handled with more care, panels with MVG fixed valves are more robust. Furthermore, installation of missing valves is avoided. Figure 8. - MVG valves Case story to Illustrate the Benefits of Lip-Slot Construction In 1997 a US gas plant in Louisiana needed to revamp a de-ethanizer, de-propanizer, debutanizer and a de-isobutanizer from conventional trays to Shell HiFi trays. Downtime was critical for the operator as is often the case in tight markets. The critical path was determined by the installation of more than 100 sieve trays in the de-isobutanizer. Comparative bids were collected for the hardware and installation for the above-mentioned towers. The solution with Lip-Slots and Wedge connection required only 65% of the installation Page 11 of 14

time quoted by the vendors using conventional bolted panel connection and tray clamps. In all cases the tray design was identical except for the fastening mechanism. Based on this difference the contract was awarded and executed successfully and the columns have not suffered any mechanical set-backs in close to 5 years of operation. Not only was money saved by the operator in installation costs but also in down time. The savings in downtime were close to the value of the new trays! Reducing Hot Work to Minimize Installation Time First step in each revamp is to determine the maximum number of existing attachments to be reused. If tray spacing is reduced from 600 mm to 400 mm in principle every second tray ring and associated beam brackets if applicable can be reused for Shell HiFi trays. Next step is to check which of the other attachments available might be reused or modified without welding to the column wall. Especially the bolting bars of the conventional trays are of interest. A typical example showing the existing tray attachments in relation with the attachments for the additional trays is shown in Figure 9. Figure 9. New and existing tray attachments (4 for 3 retray) Case story to Illustrate the Use of Non-Welded Attachments Page 12 of 14

Figure 10 shows the solution chosen for a C2-Splitter. The additional trays have been mounted on specially designed expansion rings. In order to avoid welding to the column wall the beams have also been attached to these rings. Using these techniques the installation time could not only be reduced to a minimum but it was also possible to avoid the need for heat treatment and pressure test of the vessel after the revamp. Figure 10. Drawing of expansion ring construction including beam attachments For large splitters, using 1 lattice beam to support two adjacent trays can further reduce installation time. In many cases it is possible to fix these beams to the existing bolting bars. An example of this configuration is shown in Figure 11. Page 13 of 14

Figure 11. Lattice beam construction supporting two HiFi trays Conclusion The use of high capacity trays in combination with sensible mechanical design and installation features can offer very interesting advantages in their application to C2 splitter revamps. Tray technology that includes truncated downcomers like the HiFi and CS trays combined with the extra fast Lip-Slot construction can provide 10-20% more capacity to existing splitters and be installed in a fraction of the time that other trays can for a savings of up to 35% on installation time with no welding to the column wall. Calming Section (CS), CS Plus, HiFi, HiFi Plus are trademarks of Shell Global Solutions MVG, Lip-Slot, Split-wedge are trademarks of Sulzer Chemtech Page 14 of 14