For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

Similar documents
HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

PRODUCT MANUAL Glass Touch RGB Controller 12V-24V

Angled Sign Light with Shade

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

12 Inch Barn Light. Owner s Manual

Digital Vacuum Regulator

2000 lb manual winch

Model 6812C Dual Lane Scoreboard Owner s Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Installation Instructions Air Compressor Part # 2780, 2781

HAS2400 Hepa Air Scrubber

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

RAM 4021-DPX Operation Manual

RAM 4021 Operation Manual

Digital Vacuum Regulator

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Scoreboard Operator s Instructions MPCW6 Control

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

RAM Operation Manual

KJ4000 Operating Instructions & Parts Manual NSN

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

OPERATING INSTRUCTIONS V 5.3

6 digital caliper with case

4 and 8 Station PDS Control Installation & Operators Manual

OC Panel High Limit Aquastat Kit, Manual Reset p/n

PPS PORTABLE POWER SUPPLY

SP-110 Autopilot OPERATION

Manual. FRESH AERO OneOP Model PC (Portable Compressors) Tire Inflator. Where Imagination Meets Innovation

Heavy-Duty Hot Knife

TrekMill USER'S MANUAL MM5050

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Owner s Manual and Warranty Registration

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

OPERATION AND INSTRUCTION MANUAL ROLLER SLING Model: IN106.3FT & IN106.2FT

USER MANUAL. Infinity GT Spa Table Rev B 4/24/18. *shown with optional accessories and/or finishes

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

SPECIFICATIONS APCEPH1

This document to be used with Hurley traditional Davits

Digital Vacuum Regulator

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Lil Mix Controller (Order code: LEDJ122)

Parts Manual. Frusheez Machines

Ocean Technology Systems ComBox

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

Model ASSEMBLY and OPERATING INSTRUCTIONS

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

GE Measurement & Control

4-in-1 Professional Inflator Kit

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

User Instruction Manual

NEW. Mallia TM modular. These products are part of Power Line Carrier technology system > See p

R E D I C O N T R O L S

FT500GF Dat e Code: 2 - FT500GF - - MW Purchase Date: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. All Rights Reserved

SPS-5. Rate Computing Scale. Operation Manual

DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

DEEPSEA. Sealite Sphere 6500 POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

WARRANTY, QUICK START GUIDE

Scoreboard Operator s Instructions MPC Control

AE R1 February 2015

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

Iron Filter Installation / Operation Manual

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved

AA100 Acoustic Actuator

200 PSI COMPRESSORS - MODEL NUMBERS

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

Model OPERATING INSTRUCTIONS. Due to continuing improvements, actual product may differ slightly from the product described herein.

IMPORTANT SAFETY INSTRUCTIONS

Gateway SIEVE & CHAFFER SYSTEM. Parts Book Four Panel, Single Adjustment Frames

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Permanent Roof Anchors

Modular skylight warranty

A4s Operation Manual

Installation & User Guide. English Version 1.0

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

IMPORTANT SAFETY INSTRUCTIONS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

Roller AC Servo System

Transcription:

HAI UPB High Power Wall Switch Dimmer and HAI Auxiliary Switch Installation and Operating Instructions For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch) READ THESE INSTRUCTIONS BEFORE INSTALLING DEVICE This Wall Switch Dimmer is intended for installation in accordance with the National Electrical Code and local regulations. It is recommended that a qualified electrician perform this installation. Retain these instructions for reference or download the manual from www.homeauto.com. To reduce the risk of overheating and possible damage to other equipment, do not use switch, when set to dimming-capable, to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture or a transformer-supplied appliance. This product is for indoor use only. Connect only copper or copper clad wire to this device. Important Notes Prior to Installation 1. All HAI UPB Wall Switch Dimmers require a neutral (white) connection wire. 2. Be sure that all power to the load has been disconnected by turning off the circuit breaker. Installing an HAI UPB Wall Switch with power on may expose you to dangerous voltages and may damage the device. About Your HAI UPB Wall Switch Dimmer The HAI UPB Wall Switch Dimmer (Figure 1) is a high quality light-switch/dimmer that not only allows for local rocker switch control of a lighting load but also incorporates UPB two-way powerline communication technology that gives it the ability to be remotely controlled by other UPB compatible controllers. The HAI UPB Wall Switch is highly configurable to allow for behaviors customized to each individual s desires. The HAI UPB Wall Switch is capable of storing up to 16 preset light levels and fade rates to create powerful lighting scenes. The HAI UPB Wall Switch is also capable of transmitting UPB messages (including a current light level report) when rocker switch events occur. The HAI UPB Wall Switch is capable of being set to a non-dimming mode in order to control such loads as fluorescent lights. Page 1 of 8

BREAK-OFF TABS LED INDICATOR TOP (ON/BRIGHT) BOTTOM (OFF/DIM) BLACK WHITE RED LINE NEUTRAL LOAD CONTROL WIRE FROM AUXILIARY SWITCH (wire must be capped off if not used) GROUND TO CASE Figure 1: HAI UPB Wall Switch Dimmer About Your 37A00-1 HAI Auxiliary Switch The 37A00-1 HAI Auxiliary Switch (Figure 2) is a low cost (optional) companion device to the HAI UPB Wall Switch. The 37A00-1 has a Decora-style rocker switch that controls the HAI UPB Wall Switch in the same exact way that its local rocker switch does. LED INDICATOR TOP (ON/BRIGHT) BOTTOM (OFF/DIM) BLACK GRAY BLUE LINE *NEUTRAL (FOR RED INDICATOR) *NEUTRAL (FOR BLUE INDICATOR) CONTROL WIRE FROM HAI UPB WALL SWITCH Figure 2: 37A00-1 HAI Auxiliary Switch Page 2 of 8

Installation Instructions The HAI UPB Wall Switch Dimmer is wired directly to the lighting circuit and can (optionally) be controlled by one or more HAI Auxiliary Switch producing three, four, or five-way circuits. Multi-way circuits make it possible for a group of switches to control the same set of lights. This section will illustrate how to hook-up the connections. Notes: 1. Refer to Figures 1 and 2 to determine the wire colors of the hook-up. 2. All HAI UPB Wall Switch Dimmers require a neutral (white) connection. 3. HAI Auxiliary Switches require that the Line (black) wire be accessible. This wire may be connected to either phase of the 120/240V supply. 4. The blue and/or gray wire on the HAI Auxiliary Switch Dimmer can be connected to either earth ground or neutral. The blue and/or gray wire serves only to light the LED on the Auxiliary Switch. This LED does not indicate anything except that power is applied and to serve as a night-light. LINE 37A00 (OPTIONAL) AUXILIARY SWITCH 37A00 (OPTIONAL) AUXILIARY SWITCH 55A00 HAI Wall Switch BLACK BLACK BLACK Line 120VAC, 60Hz WHITE RED *BLUE AND/OR GRAY *BLUE AND/OR GRAY COPPER NEUTRAL *CONNECTING THE BLUE AND/OR GRAY WIRE TO NEUTRAL SETS THE COLOR OF THE LED INDICATOR. CONNECT BLUE FOR BLUE INDICATOR, GRAY FOR RED INDICATOR, OR BOTH FOR MAGENTA INDICATOR. BLUE AND/OR GRAY WIRE MAY BE CONNECTED TO NEUTRAL OR EARTH GROUND. NEUTRAL IS RECOMMENDED. Figure 3: Wiring Diagram Page 3 of 8

Air-Gap Switch The HAI UPB Wall Switch rocker switch has an air-gap switch that will remove all power from the load for safe installation and bulb replacement. To activate the air-gap switch firmly press the rocker bottom until you hear a loud click or you see the SYSTEM OFF label on the top rocker. Installation Procedure 1. Remove the faceplate from the existing wall switch. 2. Unscrew and pull the existing wall switch out of the wall box. 3. Disconnect the wires from the existing wall switch. Identify the Line, "Neutral", "Load" and Traveler wires. 4. Install the 5 connecting wires per wiring configuration shown in Figure 3. Note: Be sure that the HAI UPB Wall Switch is in the SYSTEM OFF position by firmly pressing the Rocker Bottom until you click the air-gap switch to the open position or you see the SYSTEM OFF label on top of the Rocker. 5. Optionally install any HAI Auxiliary Switch per wiring configuration shown in Figure 3. 6. After all connections have been made, be certain that all wire connectors are firmly attached and there is no exposed copper. 7. Gently place the wires and Wall Switch into the wall box, with light emitting diode (LED) at the top of device, and screw in place. 8. Before installing the faceplate, restore power to the circuit, and firmly press the top of the HAI UPB Wall Switch Dimmer until it snaps out of the SYSTEM OFF position. 9. After testing the HAI UPB Wall Switch Dimmer for proper local operation (per Table 2), install the faceplate cover(s) to the outside of the HAI UPB Wall Switch Dimmer(s). De-rating Information For a proper fit in a multiple gang installation, it may be necessary to remove one or both sides (break-off tabs) from the mounting plate (see Figure 1). When tabs are removed, the overall rating of the device must be reduced in accordance with the following chart: Model Device Maximum Load (LCP*) No Fins Removed Large Box** No Fins Removed Normal Depth Box One Fin Removed Next to One Dimmer Both Fins Removed Next to Two Dimmers 55A00-2 1500W 1200W 1000W 800W 700W 55A00-3 2400W 2000W 1800W 1600W 1400W Table 1: 55A00-2 and 55A00-3 De-rating Information * LCP = PCS Lighting Control Panel ** Large Wall Box = greater than 40 CU IN (1500W), greater than 90 CU IN (2400W) Page 4 of 8

Using Your HAI UPB Wall Switch Dimmer The HAI UPB Wall Switch Dimmer is packed full of different options and configurations that can be programmed into it using the UPB UPStart configuration software. This section will describe the operation of the HAI UPB Wall Switch Dimmer in its factory default configuration. Please refer to the section entitled Configuring the HAI UPB Wall Switch Dimmer for a description of the many other configuration options available. Local Rocker Switch Operation The HAI UPB Wall Switch Dimmer has a Decora-style rocker switch that can be used to control the lighting load as described below in Table 2. Rocker Event Top Rocker Bottom Rocker Single-Tap Brightens the light to 100% (on) at a 0.8-second fade rate. Fades the light to 0% (off) at a 1.6- second fade rate. Double-Tap Snaps the light to 100% (on). Snaps the light to 0% (off). Hold Starts fading (brightening) the light towards 100% at a 3.3-second fade rate. Starts fading (dimming) the light towards 0% at a 3.3-second fade rate. Release Stops brightening the light. Stops dimming the light. Table 2: Rocker Switch Operation LED Indicator The HAI UPB Wall Switch Dimmer comes equipped with a multi-color LED indicator that is normally lit to blue. This LED indicator will blink different colors to indicate UPB communication status and configuration status as outlined in Table 3 below. HAI UPB Wall Switch Dimmer Status The load connected to the HAI UPB Wall Switch Dimmer is off The load connected to the HAI UPB Wall Switch Dimmer is on LED Color Blue Black Table 3: Status LED Operation Using Your HAI Auxiliary Switch The HAI UPB Wall Switch can (optionally) be connected to one or more HAI Auxiliary Switch producing three, four, or five-way lighting circuits. Each HAI Auxiliary Switch has a Decora-style rocker switch that can be used to control the lighting load of the HAI UPB Wall Switch in the same way as previously described in Table 2. Page 5 of 8

Configuring the HAI UPB Wall Switch Dimmer The HAI UPB Wall Switch Dimmer is highly configurable. Many of its configuration options can only be enabled or modified with the use of the UPB UPStart configuration software. Table 4 describes the many configuration options available that can be set up with the use of the UPB UPStart configuration software. NOTE: Although the factory default operation of the HAI UPB Wall Switch is useful in many situations, it is highly recommended that your HAI UPB Wall Switch be configured with an HAI controller or UPB UPStart configuration software so that you can take advantage of its many configurable features. Option Factory Default Possibilities Dimming-Capable Yes Yes or No (on/off only) Default Fade Rates Top Rocker Single- Tap Action Top Rocker Double- Tap Action Bottom Rocker Single-Tap Action Bottom Rocker Double-Tap Action Rocker Switch UPB Transmissions UPB Transmission Attempts Preset Light Levels and Fade Rates (Scenes) On = 0.8 seconds Off = 1.6 seconds Fade to 100% at the Default Fade Rate. Snap to 100%. Fade to 0% at the Default Fade Rate. Snap to 0%. Disabled 16 different fade rates from 0 (Snap) to 1 hour. Any Level (0% - 100% including Last On Level) at any of 16 Fade Rates. Any Level (0% - 100% including Last On Level) at any of 16 Fade Rates. Any Level (0% - 100% including Last On Level) at any of 16 Fade Rates. Any Level (0% - 100% including Last On Level) at any of 16 Fade Rates. Configure any of 15 different UPB Messages (including Status Report) to be transmitted upon any Rocker Switch Event. 2 1, 2, 3, or 4 transmissions per event. Linked to six pushbuttons on the HAI 6-Button Room Controller UPB ID NID = 255 55A00-2 = UID 004 55A00-3 = UID 005 Link as many as 16 different Preset Light Levels and Fade Rates to components on UPB compatible controllers. Many UPB Identification parameters can be configured including the Network ID (NID), Unit ID (UID), Network Password, Network Name, Room Name, Device Name, etc. LED Color Control (See Table 3) Any of 16 different LED modes consisting of the colors blue, red, magenta, and black. Table 4: 55A00-2 and 55A00-3 Configuration Options Page 6 of 8

Changing Preset Light Levels The HAI UPB Wall Switch Dimmer is specially designed to work with an HAI controller consisting of HAI Room Controllers and HAI House Controllers. Pushbuttons on these controllers can be configured to activate the Preset Light Levels and Fade Rates stored in the HAI UPB Wall Switch Dimmer. Once configured, the homeowner can easily adjust the Preset Light Level that gets activated by a particular pushbutton by following this simple procedure. Step Operation 1 Press the pushbutton on the HAI Room Controller or HAI House Controller to activate the currently stored Preset Light Level. 2 Use the local rocker switch on the HAI UPB Wall Switch Dimmer to set the desired Preset Light Level. 3 Press the pushbutton on the Room Controller or House Controller five times quickly. 4 The HAI UPB Wall Switch Dimmer will flash its lighting load one time to indicate that it stored the new Preset Light Level. Putting the Wall Switch Dimmer Into Setup Mode The HAI UPB Wall Switch Dimmer can be put into the Setup Mode by the following steps: Step Operation 1 Tap the HAI UPB Wall Switch local (or remote) rocker switch 5 times quickly. 2 The HAI UPB Wall Switch Dimmer will flash its lighting load one time and blink its LED blue to indicate that it is in Setup Mode. Note: the device will automatically exit Setup Mode after 5 minutes. Setting Factory Defaults The HAI UPB Wall Switch Dimmer can be set back to its factory defaults by the following steps: Step Operation 1 Identify the HAI UPB Wall Switch Dimmer that you want to set factory defaults by tapping its rocker switch 5 times quickly. 2 The HAI UPB Wall Switch Dimmer will flash its lighting load one time and blink its LED blue to indicate that it is ready to be set to factory defaults. 3 Set the factory defaults by tapping its rocker switch 10 times quickly. 4 The HAI UPB Wall Switch Dimmer will flash its lighting load one time and blink its LED red to indicate that it has been set to factory defaults. 5 Tap the rocker twice to stop the blinking. Page 7 of 8

SPECIFICATIONS Model Number 55A00-2 55A00-3 Incandescent Loads Dimming Yes Yes Inductive Loads Dimming Yes Yes Fluorescent Loads Non-dimming Yes (configurable) Yes (configurable) Power Maximum Dimming 1500W / 1500VA 2400W / 2400VA Current Maximum Non-dimming 12.5 A 20 A Connections 14 GA 12 GA LED Indicator Yes Yes Dimensions (H x W x D) 4.68 X 2.75 X 1.25 in 4.68 X 4.5 X 1.25 in Weight 0.5 lb. 0.7 lb. Minimum Load 60 W 60 W Input Power 120 ± 12 VAC 120 ± 12 VAC Input Frequency 60 ± 3 Hz 60 ± 3 Hz Operating Temp -40 F to 104 F -40 F to 104 F LIMITED WARRANTY HAI warrants this product against defects in material and workmanship, under normal use and service, for a period of two (2) years from the date of purchase. During the warranty period, HAI will repair or replace, at its sole option, if this product fails due to defect. This warranty does not cover the cost of removal or reinstallation of any product. This warranty does not cover failure caused by normal wear, damage to the product while in your possession (other than damage caused by defect or malfunction), or by its improper installation, including failure to follow the written installation and operation instructions, alterations, misuse, or abuse. The remedies provided for in this warranty are the sole and exclusive remedies thereof. In no event shall HAI be liable for incidental expenses or consequential loss or damages. For the complete HAI Warranty for USA policy, see the HAI web site at www.homeauto.com. Any implied warranties, including warranties of merchantability and fitness for particular use or purpose are limited to a period of two (2) years from purchase date. This warranty gives you specific legal rights, and you may have other legal rights, which vary from state to state. Some limitations may not apply to you. For warranty and repair service within the continental United States, send defective unit carefully packaged, postage prepaid, along with description of trouble, name, return address, and phone number to: HAI, Repair Department, 4330 Michoud Blvd, New Orleans, LA, 70129. HAI will pay return shipping charges via normal ground service. Outside of the continental United States: Contact an Authorized Distributor for repair/replacement instructions. Page 8 of 8