VZL valve - 2/3/4-way

Similar documents
The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves VRB 3, VRG 3

Seated valve for steam (PN 25)

Pressure balanced valves (PN 25)

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

3-way control valves VK 3

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

Rotary valves HRB 3, HRB 4

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

AVP-F. p setting range (bar) Code No. 003H6200

Pressure reduction controller (PN 16, 25, 40)

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Rotary valves HRB 3, HRB 4

2-port seat valves PN25 with externally threaded connections

2-port and 3-port valves PN 16

Two-port valves, male threaded, PN25

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

AVPQ/AVPQ-F, PN 16. Application

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Pressure independent balancing and control valve AB-QM DN

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Upgradable balancing valves USV

2-Port and 3-Port Seat Valves with Female Thread, PN16

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Automatic balancing valves ASV

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Two-port seat valves

Automatic balancing valves ASV

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

2-port and 3-port seat valves, PN16

HERZ - Compact Flow Controller with

HERZ - Compact Flow Controller with

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

2-Port Seat Valves with Flange, PN 16

HERZ-Motorised flow controler

V311. Venta. Three-way Plug Valve, Flanged PN 16

Automatic balancing valves

Pressure Independent Control Series

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

3-port seat valves with externally threaded connection, PN 16

Products no longer available

2-Port Seat Valves with Flange, PN 16

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Overview of types. Technical data. Safety notes

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION

Radiator valves VDN1.. VEN1..

RA-N radiator valves with integrated presetting and self-sealing tailpiece

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Radiator valves VDN2.. VEN2.. VUN2..

Products no longer available

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

STAD-C. Balancing valves DN 15-50

Pressure reducing valves Index

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Type overview. R B2 en-gb subject to changes 1

Overview of types. Technical data

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

STAD. Balancing valves DN 15-50

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

DIFFERENTIAL PRESSURE REGULATING VALVE zcon

3 & 4-Way Mixing & Diverting Valves

VBS-9263 Series. Application. Features. Applicable Literature

DRU/HE THREE-WAY ROTARY VALVE PN10 AND HE25/32 EXTENSION

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

Pressure independent control valve (PICV) FLOWMATIC

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

VB-7273 Series. Application. Features. Applicable Literature

Type 4708 Supply Pressure Regulator

VB-7263 Series. Application. Features. Applicable Literature

Automatic balancing valves ASV

Self-operated Pressure Regulators for special applications

Ballorex Dynamic Description. Versions. Benefits. Balancing

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Dual position solenoid valve Type ICSH 25-80

STAD. Balancing valves DN (MD60, MD61, MD62)

CLASS TLP Pressure Reducing Valve

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Transcription:

VZ valve - 2/3/4-way Description Stem extension plug VZ 2 VZ 3 VZ 4 VZ valves provide a high quality, cost effective solution for the control of hot and/or chilled water for fan coil units, small reheaters, and recoolers in temperature control systems. The valves are used in combination with: - AMV(E) 130(H)/140(H) ABNM A5 with extension plug; - AMV(E) 13 (SU) and TWA-Z actuators. Note: TWA-Z thermal actuator does not close port B. In case that stem extension plug is not used together with AMV(E) 130(H)/140(H) dead zone in valve close position will occur. Main data: DN 15, 20 k VS 0.25-3.5 m 3 /h PN 16 Temperature: - Circ. water / glycolic water up to 50 %: 2 120 C Reduced k VS on B port (VZ 3 & VZ 4 only) inear characteristic inear bypass on 3 and 4 port valves Valves are supplied with screwed plastic cover for manual operation Connections: flat end or conex Water quality acc. to VDI 2035 requirements Ordering 2-way valve VZ 2 Picture DN k VS max. p Code No. (mm) (m 3 /h) (bar) Flat End Conex 15 20 0.25 2.5 065Z2070 065Z2040 0.4 2.5 065Z2071 065Z2041 0.63 2.5 065Z2072 065Z2042 1.0 2.0 065Z2073 065Z2043 1.6 2.0 065Z2074 065Z2044 2.5 1.0 065Z2075 065Z2045 3.5 1.0 065Z2076 065Z2046 3-way valve VZ 3 Picture DN k VS (A - AB) k VS (B - AB) max. p Code No. (mm) m 3 /h (bar) Flat End 15 20 0.25 0.25 2.5 065Z2080 0.4 0.25 2.5 065Z2081 0.63 0.40 2.5 065Z2082 1.0 0.63 2.0 065Z2083 1.6 1.0 2.0 065Z2084 2.5 1.6 1.0 065Z2085 3.5 2.5 1.0 065Z2086 Danfoss 2018.08 VD.H.P1.02 1

VZ valve Ordering (continued) 4-way valve VZ 4 Picture DN k VS (A - AB) k VS (B - AB) max. Δp Code No. (mm) m 3 /h (bar) Flat End Conex 15 20 0.25 0.25 2.5 065Z2090 065Z2060 0.4 0.25 2.5 065Z2091 065Z2061 0.63 0.4 2.5 065Z2092 065Z2062 1.0 0.63 2.0 065Z2093 065Z2063 1.6 1.0 2.0 065Z2094 065Z2064 2.5 1.6 1.0 065Z2095 065Z2065 3.5 2.5 1.0 065Z2096 065Z2066 Accessories Type Pipe size DN Description Code No. Tailpieces with external thread Tailpieces for soldering Stuffing box Spindle extension adapter, 2 mm (5 pieces) R 3/8 15 Consist of 2 union nuts, 065Z7015 R ½ 20 2 tailpieces and 2 gaskets (Ms 58) 003H6902 12 mm 15 Consist of 2 union nuts, 2 solder bushes 065Z7016 15 mm 20 and 2 gaskets (Ms 58) 065Z7017 065F0006 003Z0249 Technical data Control characteristic inear Control range min. 30:1 eakage loss, closed valve A - AB 0.05 % of k VS B - AB 1 % of k VS Medium Circulation water / Glycolic water up to 50 % Medium temperature C 2 120 Max. operating pressure bar 16 Stroke mm 2.8 Connection Materials Body Seat cone and steam Stuffing box External thread (flat connection (MS 58) or conex) Brass CuZn40Pb2 Brass CuZn39Pb3 EPDM Pressure temperature diagram PN 16 CuZn40Pb2 Maximum allowed operating pressure as a function of medium temperature (according to EN 1092 3) Disposal The valve must be dismantled and the elements sorted into various material groups before disposal. 2 VD.H.P1.02 Danfoss 2018.08

VZ valve Installation AMV(E) 130/140, AMV(E) 130H/140H AMV(E) 13 (SU) TWA-Z ABNM-A5 Valve mounting Before valve mounting the pipes have to be cleaned and free from abrasion. Valve must be mounted according to flow direction as indicated on valve body. Mechanical loads of the valve body caused by the pipes are not allowed. Valve should be free of vibrations as well. Installation of the valve with the actuator is allowed in horizontal position or upwards. Installation downwards is not allowed. Application schemes for 3-way and 4-way mixing valves 3-way and 4-way valves are mixing valves meaning that A and B ports are inlet ports, and AB port is outlet port (f ig. 1). In case valve should be used as diverting valve it is a solution to install valve in return pipe (f ig. 2). To prevent damages, starting max. Δp must not exceed 1 bar for DN 20 and 2/2.5 bar for DN 15, when installing the valve. Fig. 1 Mixing valve used in mixing application Fig. 2 Mixing valve used in diverting application Note: Install a strainer upstream of the valve (e.g. Danfoss FVR/FVF) AMV(E) FVR/FVF Danfoss 2018.08 VD.H.P1.02 3

VZ valve Sizing Example Design data: Flow rate: 0.3 m 3 /h System pressure drop: 20 kpa ocate the horizontal line representing a flow rate of 0.3 m 3 /h (line A). The valve authority is given by the equation: ΔP Valve authority,n 1 ΔP ΔP 1 Where: ΔP1 = pressure drop across the fully open valve, ΔP2 = pressure drop across the rest of the circuit with a fully open valve The ideal valve would give a pressure drop equal to the system pressure drop (i.e. an authority of 0.5): If ΔP1 = ΔP2, ΔP N= 1 = 0.5 ΔP1 + ΔP2 In this example an authority of 0.5 would be given by a valve having a pressure drop of 20 kpa at that flow rate (point B). 2 The intersection of line A with a vertical line drawn from B lies between two diagonal lines; this means that no ideally-sized valve is available. The intersection of line A with the diagonal lines gives the pressure drops stated by real, rather than ideal, valves. In this case, a valve with k VS 0.63 would give a pressure drop of 25 kpa (point C): 25 hence valve authority 0.56 2 5 2 0 The second-largerst valve, with k VS 1, would give a pressure drop of 9 kpa (point D): 9 hence valve authority 0.31 9 2 0 Generally, for a 3 port application, the smaller valve would be selected (resulting in a valve authority higher than 0.5, and therefore improved controllability). However, this will increase the total pressure and should be checked by the system designer for compatibility with available pump head, etc. The ideal authority is 0.5 with a preferred range of between 0.4 and 0.7. Design to close to close A - AB to close A - AB A AB A AB A AB B B VZ 2 (2 Port) B VZ 3 (3 Port) VZ 4 (4 Port) 4 VD.H.P1.02 Danfoss 2018.08

VZ valve Dimensions c h 1 4.7 Ø5 Stem extension plug 92 92 92 h h d h d d H H H AMV(E) 130/140 + VZ 2 AMV(E) 130/140 + VZ 3 AMV(E) 130/140 + VZ 4 92 121 40.5 44.1 H 3 H 4 H 1 H 2 AMV(E) 130H/140H + VZ AMV(E) 13 SU + VZ TWA-Z + VZ ABNM A5 + VZ Valve type d H H 1 H 2 H 3 H 4 c h h 1 Valve weight mm (kg) VZ 2 DN 15 G ½ 65 111 117 140 88 93.5 29.5 0.27 VZ 2 DN 20* G ¾ 77 117 123 146 94 99.5 34.0 0.47 - VZ 3 DN 15 G ½ 65 111 117 140 88 93.5 35.0 0.28 47.5 VZ 3 DN 20 G ¾ 77 117 123 146 94 99.5 35.0 0.40 VZ 4 DN 15 G ½ 65 111 117 140 88 93.5 40 51.0 0.39 VZ 4 DN 20* G ¾ 77 117 123 146 94 99.5 50 65.0 0.59 * conex valves DN 20 - G 1¹/₈ 14 TPI Tailpieces for soldering Tailpieces with external thread G Ød Weight mm (kg) ½ 12 15 0.11 ¾ 15 20 0.17 G Ød G R Weight ( ) (mm) (kg) ½ 3 ₈ 23 0.11 ¾ ½ 26 0.17 G R Danfoss 2018.08 VD.H.P1.02 5

VZ valve 6 VD.H.P1.02 Danfoss 2018.08

VZ valve Danfoss 2018.08 VD.H.P1.02 7

VZ valve 8 VD.H.P1.02 Danfoss DHS-SRMT/SI 2018.08