THIS IS INDRA NAVIA COMPANY HISTORY. Gustav A Ring AS established (GAREX) Norsk Marconikompani AS established (NORMARC)

Similar documents
WINDSOCK MASTS TECHNICAL INFORMATION

Airfield Lighting. Product Description. Omnidirectional Elevated Obstruction Light (F2.1, F22)

VISUAL AIDS FOR DENOTING OBSTACLES

Airfield Lighting Product Description F2.1

Protection System AS-D

FALL PROTECTION COMPARISON BETWEEN VARIOUS OSHA STANDARDS, NAVY and EM 385 (2008) REQUIREMENTS

Advantage Lockers & Bike

Floor Mount Socket. T: +44 (0) F: +44 (0)

VISUAL AIDS FOR DENOTING OBSTACLES

Airfield Lighting. Omnidirectional Elevated Light (F2.1) Product Description

INSTALLATION. USE AND MAINTEINANCE INSTRUCTIONS FOR COLLAPSIBLE COLUMNS WITH HAND BALANCED SYSTEM

PFC Lightweight Composite Push Up Mast. Operating Manual

FALL PROTECTION / ELEVATED WORK

Type 73 Mast System TELESCOPIC & SECTIONAL MAST SYSTEMS

rugby rugby Millennium Posts Aluminium Posts No.1 Posts No.2a Posts No.3 Posts Heavy Duty Posts Post Protectors Rucking Pads

MAN-MCM-101 HEK MCM APCM

Float operated valve TYPE (SWDS)

Innovation and Safety Efficient Solution

Middle East Technical University Department of Mechanical Engineering ME 305 Fluid Mechanics I Fall 2018 Section 4 (Dr.

PLACEMENT OF SIGNS RECOMMENDED PRACTICES SUB-SECTION

GANTRY CRANES CAPACITIES: SPANS: TRACKS: OPTIONS: Up to 5 tons Up to 30' Steel Fixed or Adjustable

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Medium Voltage Switchgear. Installation Manual for Pressure Relief Ducts

10m-130mm Tubular Tower. Technical Specifications

MSA Confined Space Entry Equipment

S-60-TO : 1 ton tower system INSTRUCTION MANUAL

CLOVER CLOVER. clover. Copyrights and patents Lappset Group Ltd

Cobham Mast Systems. Cobham Mast Systems is the leading manufacturer and supplier of lightweight telescopic composite masts

Installation and Training Manual

Static and Dynamic Behaviour of the VersaBolt. Presented by Denis Champaigne VP Technical Services MMTI

Atmospheric Vent Silencers. Industrial & Marine Silencers

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

The Benefits Of Composite Materials In Deepwater Riser Applications. 26 th March 2015 Hassan Saleh Senior Engineer 2H Offshore Engineering Ltd

REVIEW ALL INSTALLATION NOTES PRIOR TO INSTALLATION!

KEEPING THE WORLD ON COURSE SINCE 1951!

Rollgliss OzPod Rescue Frame

ORG. Application example. Special Grippers O-ring Assembly Gripper. Weight 1.35 kg. Ring diameter O.D. Assembly appr.ø 5 mm.. ø 160 mm.

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

USE AND MAINTENANCE LIGHT TOWER

-Round Down- Description & Overview. VEX Classroom Competition Round Down

WARNING! DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

TECHNICAL MANUAL. COPRA Anchoring Coupler. For Smart Bolted Connections

MAINTENANCE AND OPERATING MANUAL

Rotary vane steering gear for smaller vessels

Tower Accessories & Hardware

Versie Date: USAGE AND SAFETY MANUAL SPREADERBEAMS

QUALITY IN DESIGN AND MANUFACTURE

COMPETITION EQUIPMENT. Enjoy the game

Tower Climber Orientation.

Your Life. Your Adventure. Triton Family of Products

Quattrocycle BV. Quattrocycle. User Manual. Last update February Quattrocycle BV Bremkant EJ Middelbeers. User Manual Quattrocycle 1

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Evolution. Radiant Panels. Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting

Height-safety devices

Crane Rental Heavy Machinery Moving Project Management

Product Range Trench Shoring.

Low Wind High Yields Series

COSCAP-South Asia ADVISORY CIRCULAR FOR AIR OPERATORS

Tide Gate Modifications for Fish Passage and Water Quality Enhancement

INSTRUCTION MANUAL Pressure Relief Device LPT

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

SIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15

DICTATOR "DIREKT" Gate Closer

Sterling Stairlifts. Lifting expectations

for Building facilities Industrial facilities etc.,multipurpose Pilot operated type(high capacity)

CAISSON SHAFT SYSTEM

Keel-stepped and deck-stepped masts,

TV-114 TV-114-A Wind Speed Sensor User s Manual

PHYS 101 Previous Exam Problems

Outlet Structures T-12

03/07/2014 V

Model Copyright 2012 by General Machine Products (KT), LLC

TRAVSMART permanent single-cable horizontal lifeline system

OPERATING INSTRUCTIONS. Parts List N. Note: Owner and operator MUST read and understand this operating instructions before use this lift table.

Design of a Solid Wall Transonic Wind Tunnel

Miller DuraHoist Safety Systems

markilux markilux Technical Information safe timeless beautiful markilux Collection Specification markilux 1700 markilux 1700 stretch markilux

BUCKET ELEVATORS 1 BUCKET ELEVATORS. Technical Data for Bucket Elevators (BW)

The purpose of this training is to give field technicians awareness training and guidelines on potential hazards they may encounter in the field.

DICTATOR Spring Rope Pulleys for the Closing of Sliding Doors

MSA Confined Space Entry Equipment

Constitution Instructions

VL 2K LIFT D-L WINCH INSTRUCTIONS (Applies to P/Ns , , , , , )

SET OF EUROLEAGUE BACKSTOP UNITS (Reference PK120)

A variety of other devices can be used with the front dee ring, but please check for suitability.

Applying Construction Fall Protection Concepts to General Industry

Operating instruction

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

Kronenflex cutting-off wheels 2,0 3,2 mm for hand held machines. A 24 Extra. A 24 R Supra

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

Safety assessments for Aerodromes (Chapter 3 of the PANS-Aerodromes, 1 st ed)

User Instruction Manual

Slide 1 / What is the density of an aluminum block with a mass of 4050 kg and volume of 1.5 m 3?

1. Air is blown through a pipe AB at a rate of 15 litre per minute. The cross-sectional area of broad

Counter Weight Lifting Gantry Cylinder Operation INDIA CKE2500, CKE2500-2

OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: HD26248

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Structural Design and Analysis of the New Mobile Refuge Chamber

Aerodrome Design Manual

Transcription:

THIS IS INDRA NAVIA Indra Navia is a dedicated air traffic management technology company. We design, produce, integrate and support airport communication, navigation and tower systems. Our highly customized solutions deliver outstanding long-term value under the most demanding conditions. More than 1200 airports around the world rely on our GAREX, NORMARC and InNOVA products. COMPANY HISTORY 1 2 3 4 5 6 7 1916 Gustav A Ring AS established (GAREX) 1918 Norsk Marconikompani AS established (NORMARC) 1989 ATC Division in Norcontrol (NOVA) 1997 Merged into Navia Aviation AS 2001 Park Air Systems established 2008 Northrop Grumman Park Air Systems AS created 2012 Indra purchases Park Air Systems to form Indra Navia Indra Navia Introduction

NORMARC Frangible Masts by AmpliSafe is a product family of frangible aluminium-masts, offered by Indra Navia AS in cooperation with Normeka AS. Normeka AS is a subsidiary of Indra Navia AS, and has manufactured equipment for localizer systems for airports since 1980 - mainly as a sub-supplier to Indra Navia AS. Normeka AS is a full service mechanical subcontractor with a focus in manufacturing aluminium products. Indra Navia Introduction

FRANGIBILITY At an airport, there is a lot of equipment that is necessary in order for operations to be carried out successfully. The problem is that the masts often used to elevate this equipment are a possible hazard to any airplane which, for any reason, is off course. In order to reduce the possibility for accidents it has been decided that masts that might be hit by an aircraft during takeoff/landing/taxiing must be frangible to the greatest extent possible. Definition of Frangibility ICAO Doc 9157 AN/901 Aerodrome Design Manual, part 6, Frangibility defines frangibility. A frangible object should have low mass and be designed to break, distort or yield on impact. This can be verified by FEA (Finite Elements Analysis) or full-scale testing. Certain criteria have to be met in order to claim that a structure is frangible. NORMARC Frangible Masts by AmpliSafe, have been simulated and verified by the Swedish company, DYNAmore Nordic AB. The conclusion is that the NORMARC Frangible Masts by AmpliSafe fulfill the requirements given in the above mentioned ICAO document, and the masts are considered frangible. Indra Navia Frangibility

Normeka AS is a full service mechanical subcontractor with a focus in manufacturing aluminium products. Description of NORMARC Frangible Masts by AmpliSafe NORMARC Frangible Masts by AmpliSafe can be used in many applications such as approach lights, antennas, meteorological equipment, wind socks etc. The mast itself will be the same, but the interface between the mast and the equipment will be tailor-made. NORMARC Frangible Masts by AmpliSafe are made in four different sizes. The size of the mast is determined by: the height of the mast the equipment (size, weight) to be mounted in the mast. Indra Navia Frangibility

Solutions become more powerful if you can extend the capabilities of the components, or if you can make them behave or interact in new ways.

The Four Masts 3S195 2 3M240 This is the smallest mast, it has a triangular cross-section where the side wall is 195mm. This mast is generally used for one or two approach lights (or similarly sized equipment), height of the mast up to 4 m. Also a triangular mast, with a slightly larger side wall; 240 mm. It is used as a base for the 3S195 mast when the one or two approach lights should be mounted on a mast up to 10 m. The first 6 m will then be the larger 3S240, and the upper 4 m will be the smaller 3S195 4S195. This is a mast with square cross-section, side wall 195 mm. It is used for up to 5 approach lights and a Running Rabbit light (or similarly sized equipment), height of mast up to 5 m. 4S195 3 4 4M240 This is a mast with square cross-section, side wall is 195 mm. This mast is normally used as moderate tall mast with more than two lights or as top-section when combined with 4M240. Also a square mast, with a slightly larger side wall; 240 mm. It is used as a base for the 4S195 when the requested height of the square mast exceeds 5 m. Maximum height for the combination 4M240 and 4S195 is 12 m. This combination of masts is also applicable when the requested height for the 3M/3S combination exceeds 10 m. Indra Navia Masts

Description of Accessories From Bottom to Top Base Plate Each mast is supplied with at base plate mounted to the lower end. The base plate is made of aluminum. 3 holes (triangular masts) or 4 (square masts) will be used to mount the mast to the foundation. The base plate is made of aluminum and there are 4 unique base plates to the 4 mast types. Base Plate With Hinge Normally the base plate is fixed, but it can be supplied with hinge. The hinge will ease the maintenance of the equipment mounted in the top of the mast because it is possible to swing down the mast. Thus no climbing or lifting is needed. Hinged Connection Plate Between M and S Mast Taller masts, which are compriseed of one small and one medium mast, will normally be supplied with a hinged connection plate. The reason for the hinge is the same as described above, but the hinge is placed in the connection plate between the two masts because a hinged tall mast will be very heavy to swing down and up again if hinged in the base. A middle hinge will normally be used in masts exceeding a 5 m height. The mast will be supplied with a rope arrangement in order to securely lower the upper part down. The lowering rope arrangement can be operated by two men. Normally there will be one rope supplied for each site. Connection Plate Between M and S Mast Some customers will have easy access to masts with a lift. In such cases, it will be cheaper to supply a mast without a middle hinge, only a connection plate. Indra Navia Accessories

Top Plate The top plate will always be mounted on top of the mast. Its geometry will depend on the actual equipment which the customer wants to place in the top of the mast. This will be manufactured according to customer specifications. Crossbar A special profile might be mounted horizontally on top of the mast. The mast itself is very stable, and when mounting a crossbar (which can hold up to 6 lamps, and be up to 5,5 m long) the number of masts can be kept as low as possible. Vertical Ø60 aluminum pipes are mounted to the horizontal traverse, each of them holding one lamp. Foundation The masts shall be mounted on concrete foundations. The foundations must have a certain size to withstand the bending moment imposed on it from the mast. Drawings of typical concrete foundations are enclosed in the last chapter. Normally the foundations are casted on site. The foundations will hold 3 (for triangular masts) or 4 (for square masts) foundation bolts. We supply the necessary template in order to secure correct position of the bolts. Normally not included in the delivery. Typical Configurations of Approach Lights Single light mounted on 3S mast. Hinge in the base plate. Indra Navia Accessories Three lights mounted on a mast comprising 4M as the lower section, 4S hinged as the upper section. Hinged service position.

Technical Specifications of Main Components Description Size Weight Material Max bending moment 3S mast Sidewall 195mm 5.8 kg/m Aluminum 6063 16,1 knm 3S footplate Triangular 2,9 kg Aluminum 6082 3S footplate w/hinge 6,7 kg Aluminum 6082 3S top-plate 1,0 kg Aluminum 6082 4S mast Sidewall 195mm 7,7 kg/m Aluminum 6063 29,1 knm 4S footplate Square 5,2 kg Aluminum 6082 4S hinged footplate 8,9 kg Aluminum 6082 4S top plate 1,4 kg Aluminum 6082 3M mast Sidewall 240mm 11,1 kg/m Aluminum 6063 31,4 knm 3M footplate Triangular 5,9 kg Aluminum 6082 3M-3S middle hinge 9,2 kg Aluminum 6082 3M top plate 2,0 kg Aluminum 6082 4M mast Sidewall 240mm 14,3 kg/m Aluminum 6063 83,7 knm 4M footplate Square 9,0 kg Aluminum 6082 4M-4S middle hinge 9,4 kg Aluminum 6082 4M top plate 2,5 kg Aluminum 6082 Top traverse (for mounting >1 lamp/mast) 3,55 kg/m Aluminum 6063 Max length 5500mm Light fitting pipe Ø60mm x 700 1,2 kg Aluminum 6060 Indra Navia Technical specifications

Indra Navia AS (head office) Olaf Helsets vei 6 P.O. Box 150 Oppsal NO-0619 Oslo, Norway Tel: (+47) 23 18 02 00 Fax: (+47) 23 18 02 10 sales@indra.no www.indranavia.com Indra Navia AS Bromsveien 17 P.O. Box 145 NO-3191 Horten, Norway Tel: (+47) 23 18 02 00 Fax: (+47) 23 12 37 20 sales@indra.no www.indranavia.com Indra reserves the right to modify these specifications without prior notice.