P8 to P60 Pitot-Static Probes

Similar documents
P06 & P012 Pitot-Static Probes

S-Type Pitot Tube. Operating Instructions

Operating instructions Pitot Static Tube

Air Differentail Pressure Switch

OWNER S MANUAL. AXD 530 MicroManometer

Using the Models TA-460, PVM610, and PVM620 to Measure Pressure

Experiment 8: Minor Losses

Constant Pressure Inlet (CCN) Operator Manual

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

Unit A-2: List of Subjects

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

AerE 343L: Aerodynamics Laboratory II. Lab Instructions

485 Annubar Primary Flow Element Installation Effects

IP65 Air Differential Pressure Switch

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the

Measurement of Atmospheric Pressure. Atmospheric Instrumentation

Unit 2 Kinetic Theory, Heat, and Thermodynamics: 2.A.1 Problems Temperature and Heat Sections of your book.

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Pressure Measurement

Automatic Isokinetic Sampler. ST5 Evo

AF100. Subsonic Wind Tunnel AERODYNAMICS. Open-circuit subsonic wind tunnel for a wide range of investigations into aerodynamics

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

BAPI Pressure Line of Products - FAQs

In Vivo Scientific, LLC INSTRUCTION MANUAL

PHY100 s Lab: The Relationship Between Liquid Pressure and Depth as it applies to Blood Pressure. Course & Sec:

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Properties of Fluids SPH4C

International Journal of Research in Advent Technology Available Online at:

Mass Flow Meter (MFM) for Gases

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

mass of container full of air = g mass of container with extra air = g volume of air released = cm 3

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Design Features. General Description

VALVES HIDROMATIC VALVE.

Mass Flow Controller (MFC) for Gases

Automatic Isokinetic Sampler. ST5 Evo

RTD Temperature sensor TH11

FPG8601 Force Balanced Piston Gauge

NATIONAL CENTER FOR COMBUSTION RESEARCH AND DEVELOPMENT (NCCRD) INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

VARIABLE AIR FLOW REGULATOR

Instruction Manual. Pipe Friction Training Panel

FLUID MECHANICS Time: 1 hour (ECE-301) Max. Marks :30

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

CVEN 311 Fluid Dynamics Fall Semester 2011 Dr. Kelly Brumbelow, Texas A&M University. Final Exam

ALF400 to 900, ALT-5/-9

Operating Manual. Check and Go Disposable Medical Depot, Inc Port Washington N.Y

FAN ENGINEERING. Field Testing of Fans FE-900. Introduction. Testing Equipment. Testing Standards. Prior to Testing

RLP100F910, F916, F918: Dual-channel volume flow controller

CHAPTER 6 MEASUREMENT OF INSPECTION PARAMETERS. Measurement Ports

deltaflowc deltaflowc Venturi or Probe

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

High-performance submersible pressure transmitter For level measurement Model LH-10

RGC-IR Remote Gas Calibrator for IR400

Double gas valves for biogases and recycling gases

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

T EK-COR 1100A Coriolis Mass Flowmeter

Measurement of Low GAS & Liquid Flows

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

3 1 PRESSURE. This is illustrated in Fig. 3 3.

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

For Multi-Parameter Meters see mvx

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Instruction Manual EMA 84 Digital Pressure Gauge

Radar, Ultrasonic and RF Level Transmitters

Mass Flow Controller (MFC) for Gases

analytical bulk flow distance FLOW level pressure temperature industrial communication

Model 2851 CONSTANT FLOW REGULATOR

SANP ACTING RELAYS YT-520/525/530 SERIES

OC Panel High Limit Aquastat Kit, Manual Reset p/n

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Ambient Weather WS-03 Thermo-Hygrometer

OXY 3690 MP. Measuring transducer for air oxygen

Pressure measurement explained

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

Hand-held pressure calibrator with integrated pump Model CPH6600

CSA Sample Draw Aspirator Adapter Operator s Manual

Installation and Operation Manual

1 Scope... 2 Functions of cementing float equipment... 3 Definitions... 4 Calibration... 5 Test Categories... 6 General...

LOCK UP VALVES YT-400/405/430/435 SERIES

HI 2314 HI 2315 HI 23151

AIR FLOW CALIBRATORS Single Sensor Designs

780S Ultra High Purity Series

Datasheet TM40. HUBER INSTRUMENTE AG, Grellingerstrasse 23, CH-4208 Nunningen. All rights reserved Paige 1 / 5 Datasheet_TM40_

Operating Instructions Temperature Measuring System MF420-5T-100

Integral type Differential pressure flowmeter VNT Series

OPERATION MANUAL Model 50M LFE - Laminar Flow Elements

T EK-THERMAL 1700B Thermal Mass Flowmeter

METHOD 2A - DIRECT MEASUREMENT OF GAS VOLUME THROUGH PIPES AND SMALL DUCTS. NOTE: This method does not include all of the

Digital Melting Point Apparatus

Measuring range Δp (span = 100%) Pa

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

Transcription:

P8 to P60 Pitot-Static Probes Operating Instructions: Install optional PX NPT fitting if required. See separate documentation for details. Measure in straight duct sections that are at least 1.5 diameters upstream and 8.5 diameters downstream of any duct disturbance such as elbows and meshes. Duct diameter should be at least 30 times the diameter of the probe. Minimum recommended duct diameter is 238 mm (9.4 inches). Smaller ducts will interfere with the dynamic pressure readings. Keep probe head aligned within 15 degrees of the flow direction. Errors in dynamic pressure readings will be less than 0.5% up to 12 degrees and increase to 2% at 15 degrees. Pitot tube has a flow coefficient (K) of 1.0 and requires no calibration. If you use any of FlowKinetics instruments the speed is automatically calculated. Probes are rated to 1500 F (815 C) at the tip.

2-41/64 [67.07] 5 [127.00] Ø1/8 [3.18] TOTAL PRESSURE PORT Ø0.04 [1.02] 8 EQUALLY SPACED STATIC PRESSURE PORTS R 1.0 [25.4] WALL THICKNESS 0.035 [0.89] Ø5/16 [7.94] L 2-5/8 [66.68] STATIC PRESSURE CONNECTION Ø1/4 [6.35] Probe L P8 8 [203] P12 12 [305] P18 18 [457] P24 24 [607] P36 36 [914] P48 48 [1219] P60 60 [1524] Ø1/4 [6.35] TOTAL PRESSURE CONNECTION 1/2 [12.70] NOT TO SCALE. DIMENSIONS IN INCHES [MM] MAXIMUM PROBE INSERTION DEPTH = L Pitot Static Probe P8, P12, P18, P24, P36, P48, P60

Measuring standard speed You will need a differential manometer only. Using this method you assume that the temperature and pressure in the test area are at standard conditions where Pamb=14.696psi (101325 Pa), Temp=70ºF (21.1ºC) and RH=0%. Connect the Pitot static pressure port to the low pressure port (P-) of the differential manometer. The Pitot stagnation pressure port should be connected to the high pressure (P+) port on the differential manometer. Standard speed in m/sec is calculated using V = 2 Δ P density where density = 1.2 kg/m 3 for standard air DP is the differential pressure reading from the manometer in Pascals. STATIC PRESSURE PORT (Pamb) TOTAL PRESSURE PORT (Pt) FLOW P- P+ If you are using a FlowKinetics manometer the speed is calculated automatically.

Measuring actual speed You will need a differential pressure manometer, an absolute pressure manometer and a temperature meter. Using a splitter connect the Pitot static pressure port to the low pressure port (P-) of the differential manometer and the absolute pressure port (Pabs) of the absolute manometer. The Pitot stagnation pressure port should be connected to the high pressure (P+) port on the differential manometer. This way you can measure the differential pressure and the static pressure simultaneously. Also insert the temperature sensor into the flow. Actual speed in m/sec is calculated using TEMP. SENSOR STATIC PRESSURE PORT (Pamb) FLOW Temp Pabs V = 2 Δ P density where DP is the differential pressure reading from the manometer in Pascals. density = Pabs R (Temp+ 273.15) in kg/m 3 Temp is the temperature of the flow in Celsius. R is the gas constant. R=287.026 joule kg Kelvin for air. Pabs is the static pressure measured with the absolute pressure manometer in Pascals. K is the Pitot flow coefficient (1.0) Splitter TOTAL PRESSURE PORT (Pt) If you are using a FlowKinetics FKT series manometer the speed is calculated and corrected automatically for temperature, ambient pressure, humidity and gas type. P- P+

Limitations of Usage and Cautions Pitot-Static Probes FlowKinetics LLC s products including, but not limited to, instruments, sensors, probes and accessories are not intrinsically safe, and must not be used in dangerous or hazardous areas. Servicing of these instruments incorporating battery changing must only occur in a safe area. Use of the FKS series may require working in a hazardous environment. Necessary safety precautions must be followed. FlowKinetics LLC s products are not authorized for use as any component in a life support system or device or as component of an aircraft s on board flight system. Life support systems or devices are defined as any system that can sustain, monitor or support life. Any attempts to service or modify or alter the product in any way, will void the warranty and will negate any right of claim against FlowKinetics LLC, relating to any liability in respect of the product.