Fruit Testing during Long Term Storage

Similar documents
Operating manual Analogue Brix Refractometer

Operating manual Analogue refractometer

Manual Refractometer PCE-ALK

FIELD TIP SHEET. Mark the bag with black permanent marker before filling it with water.


GOLFWORKS THE. INSTRUCTIONS FOR: Maltby Golf Club Gauge Code: GW1040. Maintenance and Care. Operating Instructions.

MASTER TRUING STAND TS-3. Optional Dial indicator set with brackets Dial indicator bracket set only

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

PAPR Flow Tester. instructions. part no WARNING

product manual H-1200 & H-1250 Universal and Portable Penetrometers

Model 130M Pneumatic Controller

user leaflet GAUGING TRANSDUCERS

Transferpette -8/-12

TEST SPECIFICATION NYT-909-C

RayPette Plus Autoclavable Pipette. User Manual

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

MULTISCALE REFRACTOMETER

Advanced Test Equipment Rentals ATEC (2832)

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

MET 335W Fluid Mechanics Laboratory. Lab 1: Bourdon Tube Calibration. Nick Peak

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

The pipettes cover a volume range from 0.1µl to 10ml.

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

MULTICHANNEL. Labnet International, Inc.

Pipettor. User Manual

Smooth Vent Valve XVD. Series

Operating Instructions

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

A N F G J I C D D L A B C D E F

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. XVD Series

OPERATING INSTRUCTIONS

#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO PORTUGUÊS

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

Ambient Weather GL152-TT Marine Time and Tide Clock User Manual

600 / 600FC OWNER'S MANUAL

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Instrument Operating Manual

Operating & Maintenance MANUAL

Abbe 5 Refractometer

PUNE TECHTROL PVT LTD. Instruction and Maintenance Manual for Float and Tape Gauge FTG

Pneumatic dead-weight tester Model CPB3500

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3

Installation, Operation, and Maintenance Manual

Oct 1, 2002 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of FINE AGGREGATE AASHTO Designation T 84 (Mn/DOT Modified)

VWR UHP j :01 Page 1. ENGLISH 1 22 DEUTSCH FRANÇAIS ESPAπOL ITALIANO

Ambient Weather GL150-B Nautical Barometer User Manual

User s Manual. Autoclavable & UV resistant. Multi-channel digital micro pipette. In Vitro Medical Diagnostic Devices (98/79/EC)

Experiment Instructions. Circulating Pumps Training Panel

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

RG1200 Service and Repair Manual

Purge Star & Ring Purge Systems

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

ST 18 Aluminium Gas Model

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

VAPOMATIC ANESTHETIC VAPORIZER

LogIT Dissolved Oxygen Probe

Vibration isolation system 1VIS10W. User manual

INSTRUCTION MANUAL CZ 630/631

Model : LMW-9620 Please read this manual carefully before using the instrument Labnics Equipment

(fig. 3) must be at the same temperature as the water in this chamber CALORIMETRIC STUDIES OF THE EXTREMITIES

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

TECHNICAL DATA CAUTION

1. ABOUT THE PRODUCT:

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

HCMTCB MATERIALS SAMPLING & TESTING PERFORMANCE CHECKLIST

Model 23H Hand Crank Seamer

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DETERMINING THE LIQUID LIMIT OF SOIL

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Experiment 13: Make-Up Lab for 1408/1420

RIFLESCOPES INSTRUCTIONS

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

1.5 m. 2.4 m. Fig the pressure exerted by the oil on the base of the tank, the force exerted by the oil on the base of the tank.

USER MANUAL. All rights reserved

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

Chlorinator MODEL MK-I

METHOD 2D - MEASUREMENT OF GAS VOLUME FLOW RATES IN SMALL PIPES AND DUCTS. NOTE: This method does not include all of the

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Name Class Date _. What factors affect a person s ability to detect gentle pressure on skin?

AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES

DPC-30 DPC-100. Reference Manual

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Underwater Housing for Panasonic Lumix DMC-ZS60, DMC-TZ80

WIKA INSTRUMENT CORPORATION

Operation and Maintenance Instructions

ST 18 Aluminium Gas Model

Model VR6 System. Installation, Operation & Maintenance

Transcription:

[Type text] This paper guides the reader on basic testing equipment and methodology for long term storage of fruits. It talks about the two most important parameters which determine fruit quality: pressure and sweetness. The paper details usage of a penetrometer and a refractometer to measure values of the fruit. It also takes a real case of apple storage in controlled atmosphere conditions. Fruit Testing during Long Term Storage Specific Emphasis - CA Storage Jeevan Upreti for Kailash Agro Cold Storage

Contents The Fruit Penetrometer... 2 Introduction... 2 Operating the Penetrometer... 3 Maintenance of the Penetrometer... 4 The Handheld Refractometer... 5 Introduction... 5 Operating a Refractometer... 6 Calibration... 6 Testing the Fruit... 6 Maintenance of the Refractometer... 7 Actual Test Results and Analysis... 7 Acknowledgement... 8 1

The Fruit Penetrometer Introduction Fruit firmness testing is a universally accepted measure of fruit quality and maturity. It can be used to help growers gauge when best to pick and ship their produce. A fruit penetrometer measures the force required to insert a plunger tip of a specific size into the flesh of a fruit. The fruit penetrometer can also be an effective tool used to help monitor fruit softening during storage. There are countless variables which affect the appropriate firmness for harvest, such as plant variety, geographical location and temperature. Experience and consistency is important in establishing the best firmness value that applies to your specific set of variables Table 1: Penetrometer model and Applications Model no Purpose Diameter of tip Fruits GY-1 General Purpose 3.5 mm Berries & Small Film Fruits GY-2 Soft Fruit 3.5 mm Soft Fruits: Citrus, Melons, Plums 1 GY-30F All Purpose 8 mm Firm Fruits: Peaches, Tomatoes, Pears 2 GY-31F All Purpose 11 mm Apples & Harder Fruits [Source: Operating manuals of Fruit penetrometer] Table 2: Penetrometer model and Specifications Model Range Diameter Accuracy Penetration depth Size GY-1 2-15 Kg/cm 3 3.5 mm +0.1 10 mm 0x 60 x30mm GY-2 0.2-4 Kg/cm 3 3.5 mm +0.02 10 mm 0x 60 x30mm GY-3 0.5-12kg/cm 3 8 mm +0.1 10 mm 0x 60 1-24 kg/ cm 3 11 mm x30mm [Source: Operating manual of Fruit penetrometer] Weight 0.3 kg 0.3 kg 0.3 kg 1 This model is being used at M/S Kailash Agro Private Limited 2 This model is being used at M/S Kailash Agro Private Limited 2

Operating the Penetrometer The followings things need to be followed before using the penetrometer: 1. Move the plunger in and out for 10 seconds to ensure the mechanism functions freely 2. Turn the small knob at the top right hand side of the meter to loosen faceplate and adjust starting value 3. Tighten again before use For best results select a random sample of 15 to 25 fruits of uniform size and temperature of the variety to be tested. Caution: Testing should always be done at room temperature, hence please wait till the fruit being tested attains room temperature after having taken it out of the chamber. Conduct test only once the fruit attains room temperature naturally. The procedure of carrying out the test varies as per the type of fruit: For large fruits: Remove a portion of skin on opposing sun and shade cheeks of the fruit midway between the stem and bottom For small fruit: It is unnecessary to remove the skin. Make a puncture test on only one cheek halfway between the stem and the bottom. Penetration should be sufficient to obtain a reading. Note: With the penetrometer upright, secure the fruit against a hard surface or in your hand and force the tip vertically into the pulp at a slow, uniform speed. The tip should penetrate to the scribed line (1 cm). Record the reading. The trailing pointer will indicate the highest resistance point tested. Note: We recommend that one person should test the entire sample lot 3

Maintenance of the Penetrometer The maintenance of these devices starts the moment test is completed. The following steps needs to be followed: Clean the penetrometer tips Clean the exposed gauge load shaft by flushing with water. To do this, carefully hold the gauge with the load shaft pointing down under a gentle stream of water for 15 seconds. Dry with a towel and allow drying further by leaving it with shaft pointing down. The penetrometer should never be lubricated with oil as this will affect the plunger friction and decrease instrument accuracy 4

The Handheld Refractometer Introduction The Hand-held refractometer is a precision optical instrument. It helps us in knowing the concentration of the liquids. In Food industry it is generally used to know the sugar level in the fruits. New devices are coming with the feature of ATC (Automatic Temperature Compensation) Features of the device are: i. Easy and very convenient to use ii. Competitive Price iii. High Quality, Accurate testing result iv. ATC Compensation Range: from 10 0 C to 30 0 C (only in the models with ATC function) Table 3: Refractometer model and Specifications: S.no Model Range Min div. Accuracy 1 RHB-10/ATC 0-10% Brix 0.1% Brix ±0.10% 2 RHB-18/ATC 0-18% Brix 0.1% Brix ±0.10% 3 3 RHB-32/ATC2F 0-32% Brix 0.2% Brix ±0.20% 4 RHB-62/ATC 28-62% Brix 0.2% Brix ±0.20% 5 RHB-82/ATC 45-82% Brix 0.5% Brix ±0.50% 8 RHB0-50 0-50 % Brix 1 % Brix ±1% 9 RHB0-80 0-80 % Brix 1 % Brix ±1% 10 RHB0-90 0-90 % Brix 0.2 % Brix ±0.2% [Source: Operating manual of Westover make Handheld Refractometer] Note: For any new style or feature model, N will be added in the model name, such as RHBN- 32ATC etc. 3 This model is being used by Kailash Agro (P) Ltd. 5

Fig 1: Refractometer Model RHB-32ATC 1 2 3 4 1 - Day Light Plate 2 - Calibration Screw 3 - Focus adjustment 4 - Eyepiece Operating a Refractometer Calibration Before using a refractometer it is important to calibrate the device please find below a stepwise guide on calibration: i. Aim the front end of the Refractometer to the direction of the bright light, and adjust the eyepiece until the reticle can be seen clearly ii. Adjustment of Null: a. Open the daylight plate and place 2-3 drops of distilled or R.O water on the main prism b. Close the daylight plate and press it lightly so the water spreads across the entire surface of the prism without any air bubbles or dry spots and allow the sample to remain on the prism for approximately 30 seconds. c. Adjust the calibration Screw until the light/dark boundary coincides with the null line. Adjustment of refractometer with temperature compensation function should be made under the condition of 20 0 C (68 0 F) environment temperature. Testing the Fruit The following steps need to be followed: i. Open the daylight plate ii. Clean the surface of prism by soft cloth iii. Drop 2-3 drops of fruit juice on the main prism 6

iv. Close the daylight plate and press it lightly, then read the corresponding scale of light/dark boundary. The reading is the Brix value of the measured solution v. After measurement, clean away the solution on the surface of the prism and daylight plate by moist cotton cloth. The prism easily gathers mold, so to keeping it dry is important. Maintenance of the Refractometer The following measures should be adopted for effective maintenance of the device i. To insure testing accuracy, recalibration occasionally is used to maintain accuracy. ii. Adjustment of Null: Liquid and Specimen should be under the same temperature. If the temperature varies greatly, the null point should be adjusted once every 30 minutes. iii. After usage, do not use water to wash the instrument, so as to prevent water from entering into the instrument. iv. Handle gently. Do not touch or scratch the optical surfaces. v. Keep instrument in an environment of dry, clean and non-corrosive air. Actual Test Results and Analysis Apples at M/s Kailash Agro were stored from October, 2015 through April, 2016 under welldefined CA conditions of 1-2 0 C temperature and 90-95 % relative humidity. Below mentioned are the graphs showing pressure variation in the apple stored under CA conditions followed by sweetness variations. Pressure( Bar) Variation in apple over period of 4 month CA (Contolled Atmosphere) Storage 18 17.5 17 16.5 16 15.5 15 13.5 13 17.5 16.25 15.8 15.75 15.75 15.5 15.5 15.2 15.25 15.25.75 15.25.25 Oct,2015 Nov,2015 Dec,2015 Jan,2016 Chamber 6 Chamber 7 Chamber 8 Chamber 9 Chamber 10 Chamber 11 7

Sweetness( Brix) Variation in apple over period of 4 month CA (Contolled Atmosphere) Storage 16 15 13 12 11 12 11 12.5 11.5 11.25 11 10.75 13.5 13 12 15 13 10 10 9 Oct,2015 Nov,2015 Dec,2015 Jan,2015 Chamber 6 Chamber 7 Chamber 8 Chamber 9 Chamber 10 Chamber 11 Apart from showing a regular behavior of temperature and pressure variation the results also help determine: i. Correct time for opening CA chambers with respect to ideal pressure and sweetness of fruit to fetch the best price. ii. A smooth variation in pressure and sweetness reinforces the effectiveness of storage conditions in the chamber i.e. proper gas tightness, no leakages, proper air circulation and a well-defined storage and stacking pattern. Acknowledgement The author acknowledges Kailash Agro Private Limited and its management led by Mr. Kartik Jalan (CEO) for their support and motivation in carrying out the study. 8