GAS LIMITING ORIFICE VALVES LVG SERIES

Similar documents
BVA BUTTERFLY VALVES

IPG IGNITION GAS PILOTS BACK-LOADED GAS

PGM PREPIPED GAS MANIFOLD

ORIFICE METERS. WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel.

BBG BETA BURNER GAS SERIES

BBC BETA BURNERS. WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel.

North American Orifice Metering System

MRO Oil-Air Ratio Regulator

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

1200B2 Series Service Regulators. Instruction Manual

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Noth American 7347 High Pressure Gas Regulators

1800C and 1800C-HC Series Service Regulators

ELKHART BRASS MANUFACTURING COMPANY

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Natural Gas to L.P. Gas Conversion Kit

North American 7337A/B/C-4 High Pressure Gas Regulators

Instruction Manual No. 742, 8/98

MEGR-1627 Instruction Manual

SPECIFICATIONS CAPACITY

MEGR-1912 Instruction Manual

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Installation Instructions

Types S100K and S102K Pressure Regulators

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Typical Piping Layouts for PREMIX Blower Mixer Systems

Your safety and the safety of others are very important.

Natural Gas to L.P. Gas Conversion Kit

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

GAS VALVE RETROFIT KIT Pull Through Tube Heater Models

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Regulator from 1800 B series

R122H, R222, R232A, and R232E Series Instruction Manual

Operation Manual Piston Sensed Gas Pressure Regulators

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

G96 Series BASOTROL Dual Operator Valve

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

INSTALLATION & OPERATION MANUAL FOR Teppan-Yaki Griddles

ACCESSORY KIT INSTALLATION MANUAL

SL G3 - Fuel Conversion to Propane (NG to LP) P-Kit 302

2.0 INSTALLATION & SERVICE

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

GM-7000 Series CE Approved Gas Control Valve

R600 and HSRL Series Instruction Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Gas Conversion Kits Push Through (Positive Pressure) Tube Heater Models

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

ACCESSORY KIT INSTALLATION INSTRUCTIONS

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Commonwealth of Massachusetts Approved Product Approval code G

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

R600 and HSRL Series Instruction Manual

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

GM Series Dual-Block Multi-Function Gas Control Valves

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

Combination Air Valve

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

SL G3. Warning

Types 749B and R130 Changeover Manifolds

Installation Instructions For Natural Gas Conversion

BGC258 Series BASOTROL Gas Valve

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

1805 Series Relief Valves

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

RHPS Series PRV 6 User Manual

MODEL 240 GAS PRESSURE REGULATOR

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SPECIFICATIONS ATTENTION

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

North American 7339 High Pressure Gas Regulators

Pressure Regulating Valve. O&M Manual. PRV-15K Part # ,000 PSI MAWP. PRV-20K Part # ,000 PSI MAWP

Installation Instructions for NP100 Series Nitrogen Control Panels

INSTRUCTIONS FOR MODEL SSC LOW DELIVERY PRESSURE GAS REGULATORS

Gas Valve Replacement Kit

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

T208 Series Tank Blanketing Vapor Recovery Regulators

installation instructions

INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KITS: RXGY-F29, F30, F31, F32 & F33

RB Series Regulating System

Combination Air Valve Model

American Meter Co. Five-Year Limited Warranty Industrial Regulators

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Installation Instructions

Design and Application Details MICRO-RATIO Valves

Transcription:

GAS LIMITING ORIFICE VALVES LVG SERIES INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components, by unqualified personnel, can result in fire, explosion, severe personal injury, or even death. TABLE OF CONTENTS Subject Page A. General Information... 2 B. Receiving and Inspection. 2 C. Capacities... 3 D. Dimensions. 6 E. Installation.. 6 F. Operation 7 G. Maintenance... 7 These instructions are intended to serve as guidelines covering the installation, operation, and maintenance of Hauck equipment. While every attempt has been made to ensure completeness, unforeseen or unspecified applications, details, and variations may preclude covering every possible contingency. WARNING: TO PREVENT THE POSSIBILITY OF SERIOUS BODILY INJURY, DO NOT USE OR OPERATE ANY EQUIPMENT OR COMPONENT WITH ANY PARTS REMOVED OR ANY PARTS NOT APPROVED BY THE MANUFACTURER. Should further information be required or desired or should particular problems arise which are not covered sufficiently for the purchaser's purpose, contact Hauck Mfg. Co. HAUCK MANUFACTURING CO., 1 North Harris Street Cleona, PA 1742 717-272-351 4/14 www.hauckburner.com Fax: 717-273-9882

Page 2 WARNING This equipment is potentially dangerous with the possibility of serious personal injury and property damage. Hauck Manufacturing Company recommends the use of flame supervisory equipment and fuel safety shutoff valves. Furthermore, Hauck urges rigid adherence to National Fire Protection Association (NFPA) standards and insurance underwriter s requirements. Operation and regular preventative maintenance of this equipment should be performed only by properly trained and qualified personnel. Annual review and upgrading of safety equipment is recommended. A. GENERAL INFORMATION The Hauck LVG Series Limiting Orifice Gas Valves are designed for use with each burner in a multiple furnace application. They allow fine gas flow adjustment of individual burners to achieve the desired air/gas ratio at each burner. The standard LVG series valves can be used as straight through type valves, and are designed for use with any commercial fuel gas. B. RECEIVING AND INSPECTION Upon receipt, check each item on the bill of lading and/or invoice to determine that all equipment has been received. A careful examination of all parts should be made to ascertain if there has been any damage in shipment.

C. CAPACITIES Page 3 NATURAL GAS Full Open Valve Capacity PRESSURE DROP Model No. Pipe 1"wc 2"wc 4"wc 6.9"wc 13.8"wc.8"wc 27.7"wc Size 2.5 mbar 5 mbar 1 mbar 17.2 mbar 34.3 mbar 51.8 mbar 69 mbar LVG 55E 1/2 NPT 275 41 575 757 1,55 1,29 1,47 LVG 57E 3/4 NPT 5 59 815 1,7 1,5 1,855 2,1 LVG 51D 1 NPT 635 87 1,23 1,625 2,245 2,75 3,155 LVG 512D 1-1/4 NPT 1,7 1,5 2,16 2,8 4, 4,89 5,63 LVG 515D 1-1/2 NPT 1,5 2,1 3, 3,93 5,56 6,7 7,68 LVG 5D 2 NPT 2,56 3,5 5,1 6,565 9,8 11,1 12,7 LVG 525A 2-1/2 NPT 3,985 5,63 7,97 1,48 14,83 18,16,96 LVG 53A 3 NPT 5,215 7,83 14,33 13,7 19,4 23,77 27,4 LVG 5A 4"FLG 9,37 13,2 18,7 24,6 34,88 42,7 49,27 Notes 1. Capacities based on natural gas at.6 s.g. and 6 F (or C). 2. Pressure drop measured across full open valve. 3. Maximum inlet pressure is 15 psig (134 mbar) 4. For natural gas leakage rates with valve fully closed, consult Hauck.

C. CAPACITIES (Continued) Page 4 1 8 6 LVG 55E (1/2") Percentage of Maximum Flow vs 1 2 3 4 5 6 7 LVG 57E (3/4") 1 8 6 1 2 3 4 5 6 7 8 LVG 51D (1") LVG 512D (1 1/4") 1 8 6 1 2 3 4 5 6 7 8 9 1 1 8 6 1 2 3 4 5 6 7 8 9 1 11 12 LVG 515D (1 1/2") 1 8 6 1 2 3 4 5 6 7 8 9 11112131415 LVG 5D (2") 1 8 6 1 2 3 4 5 6 7 8 9 11112131415

Page 5 C. CAPACITIES (Continued) LVG 525A (2 1/2") Percentage of Maximum Flow vs 1 9 8 7 6 5 3 1 2 4 6 8 1 12 14 16 18 22 24 LVG 53A (3") Percentage of Maximum Flow vs 1 9 8 7 6 5 3 1 2 4 6 8 1 12 14 16 18 22 24 LVG 5A (4") Percentage of Maximum Flow vs 1 9 8 7 6 5 3 1 4 8 12 16 24 28 32 36

D. DIMENSIONS See appropriate Dimension sheet for detailed dimensional information. Page 6 E. INSTALLATION The LVG valves are designed as straight through valves and feature an arrow indicating the intended direction of flow. NOTE Tighten all connections to ANSI/ASME B1..1 specifications. Install the LVG in the gas line as close to the burner as possible, downstream of a shutoff valve, gas orifice meter and gas controlling valve, and in an area that allows easy access to the valve s adjusting mechanism. X726 (NOT TO SCALE)

Page 7 F. OPERATION The LVG series valves can be used with any clean commercial fuel gas. For flow adjustment, remove the hex screw cap from the valve. Using a flat-head screwdriver (1/4" allen wrench on LVG 525 5 sizes), adjust the piston assembly until the desired flow rate is achieved. Counterclockwise rotation increases gas flow. IMPORTANT Replace the hex screw cap when adjustment is complete to seal the valve. G. MAINTENANCE All LVG series valves are designed for maintenance free operation. Under normal usage, no service should be necessary. For the LVG 55-5 size valves, the entire piston cartridge may be removed for inspection or maintenance of the valve orifice. Remove the cartridge by unscrewing the brass hex connection. Replace the cartridge when complete.