NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

Similar documents
NZQA registered unit standard version 3 Page 1 of 6

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

Explosion Protection Technology Pty Ltd

Explosion Protection Technology Pty Ltd

NZQA registered unit standard version 1 Page 1 of 5. Meet requirements for Approved Filler Test Certificate for refrigerants

IECEx OPERATIONAL DOCUMENT

NZQA registered unit standard 1178 version 7 Page 1 of 6

NZQA registered unit standard version 2 Page 1 of 5. Press wood veneer into plywood and laminated veneer lumber

NZQA expiring unit standard version 6 Page 1 of 5. Demonstrate knowledge of electrical safety and safe working practices for electrical workers

NZQA Expiring unit standard version 2 Page 1 of 5. This unit standard is for people involved with pest control in rural environments.

NZQA unit standard version 1 Page 1 of 5. Demonstrate knowledge of hazardous substances relevant to Certified Handlers

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

NZQA registered unit standard version 3 Page 1 of 7. Demonstrate knowledge of bitumen gangbar sprayers and operations

NZQA registered unit standard 676 version 5 Page 1 of 5

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

QUALIFICATION DETAILS

Intrinsic safety 101 hazardous locations

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

ATEX and explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 8. Operate bitumen gangbar sprayer transfer, heating, and blending equipment

NZQA Expiring unit standard version 7 Page 1 of 8. Demonstrate knowledge of safe working practices in telecommunications.

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

Dangerous Substances and Explosive Atmosphere Regulations 2002 Appendix 2 Detailed assessment & zone classification where DSEAR applies to an area

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

NZQA registered unit standard version 2 Page 1 of 5

NZQA Expiring unit standard 8296 version 5 Page 1 of 5

Procedure: Pressure equipment safety

NZQA registered unit standard version 3 Page 1 of 6

A Unified Marking System for Ex Equipment

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of health and safety when welding and thermal cutting

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

NZQF NQ Ref 1594 Version 2 Page 1 of 8

NZQA unit standard version 1 Page 1 of 6. Describe hazards and apply risk reduction techniques and strategies while driving a bus or coach

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 5: Dive supervisor. Australian/New Zealand Standard

AS/NZS :2013. Training and certification of occupational divers AS/NZS :2013. Part 2: Surface supplied diving to 30 m

NZQA registered unit standard 1269 version 7 Page 1 of 5. Plan, prepare for, and carry out line shifts in a cable harvesting operation

SOP. Working in Confined Spaces

NZQF NQ Ref 1542 Version 3 Page 1 of 9. This qualification has been reviewed. The last date to meet the requirements is 31 December 2020.

NZQA Expiring unit standard version 3 Page 1 of 5. Demonstrate knowledge of the varroa mite and its control in the beekeeping industry

Course outline: 111 WH&S E101A UEENEEE101A - Occupational Health and Safety regulations, codes and practices in the workplace

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E

SWMS No 009 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 4

National Certificate in Equine (Community Coach) (Level 3)

NZQA registered unit standard version 2 Page 1 of 5

This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents

Confined Spaces. This procedure applies to all workers of the Diocese of Maitland Newcastle (DoMN).

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

Occupational Health and Safety Act

IECEx Certificate of Conformity

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

CONTRACTOR WHS HAZARD STANDARD CONFINED SPACE EXTERNAL USE ONLY

IGO GROUP SAFETY STANDARD 30 - WORKPLACE VENTILATION INDEPENDENCE GROUP NL

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Demonstrate knowledge of New Zealand Rules of Harness Racing and Regulations and their application

Level 2 Award in Working in Medium Risk Confined Spaces

NZQA registered unit standard version 5 Page 1 of 5. Demonstrate knowledge of abandon ship procedures and sea survival techniques

Release: 1. UEPOPL002A Licence to operate a reciprocating steam engine

Provide initial response at rope rescue incidents

ONTARIO REGULATION 632/05 CONFINED SPACES

Australian/New Zealand Standard

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

PURPOSE To define the minimum requirements for controlling risks associated with persons entering or working in confined spaces.

Hampstead Hill School Health and Safety Policy: Confined Spaces

URBAN SEARCH AND RESCUE - OPERATIONS Undertake structural collapse rescue as part of an urban search and rescue (USAR) operation

Demonstrate lead climbing on bolted rock climbs

FOOD GRADE MACHINERY GREASE (DISCONTINUED) MATERIAL SAFETY DATA SHEET

ontario regulation 629/05 made under the occupational health and safety act

AS/NZS 1596:2014. The storage and handling of LP Gas AS/NZS 1596:2014. Australian/New Zealand Standard. Superseding AS/NZS 1596:2008

Safe Work Practices (SWP) SWP (3) CONFINED SPACE ENTRY

Safe Work Practices / Procedures / Instruction CONFINED SPACE

DSEAR Assessment. To be completed in conjunction with any generic risk assessment for the task/activity being undertaken.

TOXIC GAS DETECTORS IN THE WORKPLACE UK REGULATIONS AND STANDARDS

WHS PROCEDURE P Confined Spaces. Approved by: Ruth Hampton Review Date: 6 th December 2015

Certificate of Conformity

Further technical information is available on

Level 2 Award in Working in High Risk Confined Spaces

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

INSPECTION, TESTING AND CERTIFICATION OF GASFITTING WORK DONE UNDER SUPERVISION

Australian/New Zealand Standard

NZQF NQ Ref 0733 Version 4 Page 1 of 10

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Qualification details

NZQA Expiring unit standard version 5 Page 1 of 5

Protocol for Confined Space Entry Requirements

flammable dust II 1D or II 1/2D or II 1/3D Level measuring devices and silo equipment for the potentially explosive atmospheres

Procedure: Permit Activities-Work in Confined Spaces and Hot Works

Technical Data. Dimensions

This standard comprises the following:

Flammable Environments Guideline

CPCCWHS1001 Prepare to work safely in the construction industry

Working in Confined & Enclosed Space Policy

Level 2 Award in Working in Low Risk Confined Spaces

Confined Space Entry Program Guidelines (Human Resources - Health and Safety Department)

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

(2) but does not include a shaft, trench or tunnel that is a mine or is part of the workings of a mine.

Mine Rescue Certification Training Standard

Transcription:

Page 1 of 7 Title Conduct a conformity assessment of explosion-protected apparatus Level 6 Credits 9 Purpose This unit standard covers the assessment and certification of explosion-protected apparatus with a certificate of conformity other than an IECEx, ATEX, ANZEx or AUSEx Certificates, and producing a conformity assessment document. It encompasses skills and knowledge to examine and compare document content, compare requirements of IEC or AS/NZS Standards with alternative Standards on which the original certification was based, knowledge of explosion-protection techniques, and technical report writing. This unit standard is for electrical engineers and inspectors who are responsible for the design, selection, or inspection of explosion-protected electrical apparatus for use in hazardous areas. People credited with this unit standard are able to: demonstrate knowledge of the documentation used in assessing explosion-protected apparatus for conformance to accepted Standards; demonstrate knowledge of the processes used in assessing explosion-protected apparatus for conformance to accepted Standards; prepare to conduct conformity assessment; conduct conformity assessment; and document and submit conformity assessment report. Classification Explosive Atmospheres > Electrical Apparatus in Explosive Atmospheres - Compliance Available grade Achieved Entry information Critical health and safety prerequisites Unit 26740, Demonstrate and apply intermediate underpinning knowledge of electrical apparatus in explosive atmospheres, or demonstrate equivalent knowledge and skills. Candidates must be an Electrical Inspector holding current registration and a practising license with the Electrical Workers Registration Board (EWRB).

Page 2 of 7 Explanatory notes 1 This unit standard has been designed for training and assessment on-job or off-job in a simulated environment which includes explosion-protected apparatus and wiring systems similar to those encountered in a real workplace. 2 It is recommended that candidates undertaking this unit standard be working towards achievement of the National Certificate in Electrical Apparatus in Explosive Atmospheres (Level 4) [Ref: 1671]. 3 Candidates who achieve this unit standard will be given industry endorsement for explosion-protection techniques relating to one or more of: mining, gases or dusts, depending on which explosion-protection technique competence is demonstrated. The explosion-protection endorsements are as follows: Unit endorsement suffix Competence demonstrated Ex d Flameproof Ex e Increased safety Ex n Non-sparking Ex i Intrinsic safety Ex p Pressurization Ex td (DIP) Protection by enclosure dusts I Group I apparatus only Gases Gas hazards only Dusts ELV Dust hazards only For apparatus and systems operating at extra-low voltage. For further detail about the explosion-protection endorsements, please contact ETITO at http://www.etito.co.nz. 4 This unit standard is directly equivalent to Unit 2.9 Conduct a conformity assessment of explosion-protected equipment in the Australian/New Zealand Standard AS/NZS 4761.1:2008 Competencies for working with electrical equipment in hazardous areas (EEHA) Part 1: Competency standards and includes essential skills and knowledge as specified in the relevant clauses. It aligns with Australian Competency Standards UEENEEM035A, UEENEEM036A and UEENEEM037A from UEE07 Electrotechnology Training Package Version 3.1 (copyright Australian National Training Information Service). 5 This unit standard is intended to be assessed against in conjunction with other work skills related to compliance assessment of electrical/electronic apparatus and general technical evaluation and report writing at NZQF Level 5 or above. 6 Competence is to be demonstrated in relation to any classified hazardous areas and explosion-protection technique. A copy of a candidate s current practising licence must be presented at the time of assessment. 7 References AS/NZS 1768:2007, Lightning protection; AS/NZS 3000:2007, Electrical installations (known as the Australian/New Zealand Wiring Rules); AS/NZS 4761.1:2008, Competencies for working with electrical equipment for hazardous areas (EEHA) Part 1 Competency Standards;

Page 3 of 7 AS/NZS 4761.2:2008, Competencies for working with electrical equipment for hazardous areas (EEHA) Part 2 Guide to assessing competency; AS/NZS 60079.10.1:2009, Explosive atmospheres Classification of areas Explosive gas atmospheres; AS/NZS 60079.14:2009, Explosive atmospheres electrical installations design, selection, and erection; AS/NZS 60079.17:2009, Explosive atmospheres electrical installations inspection and maintenance; AS/NZS 60079.29.2.2008, Explosive atmospheres Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen; AS/NZS 61241.0:2005, Electrical apparatus for use in the presence of combustible dust General requirements; AS/NZS 61241.14:2005, Electrical apparatus for use in the presence of combustible dust Selection and installation; AS/NZS 61241.2.1:2000, Electrical apparatus for use in the presence of combustible dust Test methods Methods for determining the minimum ignition temperature of dust; Electricity Act 1992; Electricity (Safety) Regulations 2010; Hazardous Substances and New Organisms Act 1996; Health and Safety in Employment Act 1992, and associated regulations; New Zealand Electrical Codes of Practice (NZECP), ISSN 0114-0663 (available from the Ministry of Economic Development); Standards Australia HB13-2007, Electrical equipment for hazardous areas; Workplace Exposure Standards and Biological Exposure Indices, available from the Department of Labour, http://www.osh.govt.nz/order/catalogue/329.shtml, and associated regulations; and all subsequent amendments and replacements. 8 Definitions ANZEx Australian/New Zealand Certification Scheme for explosion-protected electrical equipment. ATEX derived from French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles. Appropriate personnel individuals with responsibilities for co-ordination, design, installation, maintenance, production or servicing activities. This can include: site managers, project managers, engineers and technicians, technical experts, line managers or supervisors, regulatory personnel, team leaders, other personnel designated by an organisation or enterprise. AUSEx Electrical equipment in hazardous areas Australian certification scheme. Certification documentation document(s) that assure(s) the conformity of a product, process, system, person, or organisation with specified requirements. Established procedures formal documented arrangements of an organisation, enterprise or statutory authority in regard to how work is to be done and by whom and may include but are not limited to quality management systems, safety management systems, work clearance systems, work instructions, reporting systems, and arrangements for dealing with emergencies. Explosion-protection techniques techniques applied to the design of electrical apparatus, components, and systems to prevent the electrical energy from becoming an ignition source in the presence of flammable vapours and gases or combustible dusts in explosive atmospheres. See Explosion-protected apparatus.

Page 4 of 7 Explosion-protected apparatus electrical apparatus to which specific measures are applied to avoid ignition of a surrounding explosive atmosphere. Such apparatus employs one or more of the following explosion-protection techniques: For gas and vapour atmospheres Ex d flameproof; Ex e increased safety; Ex i intrinsic safety; with levels of protection Ex ia, Ex ib and Ex ic; Ex n non-sparking; For dusts Ex id intrinsic safety (dusts); Ex td enclosed; Others, less common Ex p pressurisation; Ex pd (dust); Ex m encapsulation, with levels of protection Ex ma, Ex mb, Ex mc (gases and vapours), and Ex md (dusts); Ex s special protection; categorised by Zone of application; e.g. Ex s (Zone 0); Ex o oil immersion; Ex q sand filled; Ex v ventilation. Explosive atmosphere an atmosphere comprising volatile substances mixed with air under atmospheric conditions in the form of gases, vapours, mist, or dust, in which, after ignition has occurred, combustion spreads to the entire unburned mixture. Hazardous area area in which an explosive atmosphere is present, or may be expected to be present, in quantities such as to require special precautions for the construction, installation, and use of apparatus. IEC International Electrotechnical Commission, the international standards and conformity assessment body for all fields of electrotechnology. IECEx IEC system for certification to standards relating to equipment for use in explosive atmospheres. Verification dossier a set of documents showing the complete compliance history of electrical apparatus and installations within hazardous areas, as defined in Standards. 9 Range a Assessment is to take account of variations between the industry sectors and enterprises. For example, apparatus used in underground coal mining will be different in some respects from that used in a petrochemical plant. b Occupational Safety and Health (OSH) policies and procedures may include but are not limited to work permits and clearances, hazard monitoring, evacuation procedures, plant and electrical isolation. c The application of contingency management skills must be demonstrated for all outcomes and evidence requirements. d Established maintenance procedures must be followed. e All activities and evidence presented for all outcomes and evidence requirements in this unit standard must be in accordance with safe working principles and practices, legislation, policies, procedures, ethical codes and Standards, safe and sound practice, and industry practice; and, where appropriate, manufacturers instructions, specifications, and data sheets.

Page 5 of 7 Outcomes and evidence requirements Outcome 1 Demonstrate knowledge of the documentation used in assessing explosion-protected apparatus for conformance with accepted Standards. 1.1 Documentation and Standard(s) required to begin an assessment are identified. 1.2 Differences between the test requirements of Standards from other countries and the compliant/acceptable Standards against which the apparatus is being assessed are identified. 1.3 Results given in apparatus test reports are explained. Outcome 2 Demonstrate knowledge of the processes used in assessing explosion-protected apparatus for conformance to accepted Standards. 2.1 Conformity assessment processes and procedures are explained. 2.2 Processes and procedures for assessing previously certified explosionprotected apparatus to current acceptable Standards is described, and possible outcomes are identified. 2.3 A clause-by-clause assessment between the apparatus manufacturing Standards and the current acceptable Ex Standards are described in terms of processes and procedures used and differences between the Standards that may be detected. Outcome 3 Prepare to conduct conformity assessment. 3.1 Certification documentation is obtained and read to determine the certification specifications for which the apparatus has been assessed. 3.2 Relevant Standards required to begin the conformity assessment are obtained in accordance with established procedures. 3.3 OSH policies and procedures are followed where a site inspection is required to identify apparatus that is already installed and is subject to the conformity assessment.

Page 6 of 7 Outcome 4 Conduct conformity assessment. 4.1 Conformity assessment is carried out in accordance with OSH and other established procedures. 4.2 Knowledge of all Standards to be used including IEC, ATEX or AS/NZS Standards is applied to a detailed comparison with alternative Standards on which original certification is based. 4.3 The documented certification criteria of the apparatus are compared to those required by currently acceptable Standards, including any test on which the certification is based. 4.4 Discrepancies between the certification documentation and IEC, ATEX, AUSEx or AS/NZS Standards are identified and actions needed to correctly address each of these are recorded. Outcome 5 Document and submit conformity assessment report. 5.1 Conformity assessment results are documented in a conformity assessment document, which informs whether the apparatus provides an equivalent level of safety to be installed, maintained, overhauled/repaired, and used safely within a hazardous area. 5.2 Recommendations for corrective actions to address discrepancies are included in the conformity assessment document. 5.3 Conformity assessment document is forwarded to appropriate personnel in accordance with established procedures for inclusion in the verification dossier. Planned review date 31 December 2016 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 29 August 2000 30 June 2012 Review 2 17 June 2011 N/A Consent and Moderation Requirements (CMR) reference 0003 This CMR can be accessed at http://www.nzqa.govt.nz/framework/search/index.do.

Page 7 of 7 Please note Providers must be granted consent to assess against standards (accredited) by NZQA, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMRs). The CMR also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the (ETITO) reviewcomments@etito.co.nz if you wish to suggest changes to the content of this unit standard.