Flow controller Type ED/CCB311 Instruction manual

Similar documents
Magnetic level switch type MR783 Instruction Manual

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Instruction Manual Contact Pressure Vacuum Gauge

INSTRUCTION MANUAL Pressure Relief Device LPT

Further technical information is available on

FIREFIGHTING EQUIPMENT

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

GA24 Technical Datasheet

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

WHEATLEY Series 500 Swing Check Valve

OFFICINE OROBICHE S.p.A. 1/9

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Instruction Manual Differential Pressure Transmitter

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Engineering Data Sheet

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

Steam Trap BK BK 212-ASME. Original Installation Instructions English

CAST IRON SAFETY VALVE TYPE 6301

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

BALL VALVE ASSEMBLY AND MAINTENANCE PROCEDURE FOR LCV BALL VALVES REF. DOC. MMM LCVE Rev.0 July 2010 SERIES SFF & SFR.

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

BALL VALVE ASSEMBLY AND MAINTENANCE PROCEDURE. REF. DOC.MMM900N Rev.1 March 2014 SERIES M DIN / ANSI. Page 1 of 17

ATS430 turbidity sensor Retractable insertion assembly

User guide DIAPHRAGM SEALS. Industrial instrumentation for Pressure and Temperature

Manual Actuated Boiler Blowdown Valves

Installation Instructions

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

GM Series Dual-Block Multi-Function Gas Control Valves

6-5 Maintenance Manual

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

6301 TYPE CAST IRON SAFETY VALVES

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

VALVES HIDROMATIC VALVE.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Preparation and Installation of the Standard Type Flat Seat Rupture Disc / UNISERT Insert Holder Assembly (Sizes 10 and Larger)

SCA Series Inverted Bucket Steam Traps

KTM 50 (DN ) Installation, maintenance and operating instructions

Materials : Stainless steel ASTM A351 CF8M

OPERATION MANUAL PNEUMATIC VALVES

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Pressure Independent Control Series

USER MANUAL. MACMAG magnetic separator MHK MHF

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY Series 822/820 Swing Check Valve

SLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections

OPERATING INSTRUCTIONS

Operating instruction

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Steam Trap BK 15 (DN40, DN 50) Original Installation Instructions English

Installation, Operation and Maintenance Manual for Back Pressure Regulator

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

GM-7000 Series CE Approved Gas Control Valve

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Declaration of Conformity as per Directive 97/23/EC

FPD175 Compact orifice carrier assembly

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

G96 Series BASOTROL Dual Operator Valve

FLANGED TWO-PIECE BALL VALVES

Vane Flow Switches Colima FLU Series

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Installation. Use. Maintenance INSTRUCTIONS. Care

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure Reducing Valve DMV 750 set range: bar

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

TP1 and TP2 Temporary Cone Shaped Strainers

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

1305 Series Pressure Reducing Regulators

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

Instruction Manual Differential Pressure Transmitter

Manual winch MANISTOR 100 and 200

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Float Operated Level Controllers

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Model MTB-ASME Vertical Bladder Tanks

Installation, operation & maintenance manual - original version

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

FIREFIGHTING EQUIPMENT

Mixers. Venturi proportional mixers EMM & EMMTR (E2351 rev /07/2017)

Accessories. Differential pressure gauges for air and gas MAG-A & MAG-G (E5275 rev /04/2010)

Model MTB-ASME Vertical Bladder Tanks

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Transcription:

Flow measurement Flow controller Type ED/CCB311 1. GENERAL DESCRIPTION page 4 2. DETAILED DESCRIPTION page 4 3. PIPE - EXPLOITATION page 5 4. PREVENTIVE MAINTENANCE page 5 5. REPLACEMENT OF THE CONTACT UNIT (6) or (6 ) page 5 5.1. DISASSEMBLY page 5 5.2. REASSEMBLING page 5 6. ESSENTIAL SAFETY REQUIREMENTS page 6 7. SPARE PARTS page 7 8. WARRANTY page 7 Houdec Instrument SAS

Flow measurement Page 2

Flow measurement Read the manual Page 3

Flow measurement 1. GENERAL DESCRIPTION - CHARACTERISTICS Metal flow controller in stainless steel used to detect weak flows in horizontal or vertical piping systems (direction of the ascending flow). This is a device with very simple and reliable design. The flow controller is made essentially of a body with fixed flanges PN16 FS or PN20(150lbs) (DN depending on the model) including a diaphragm paddle set, and an aluminum box IP65 with a reed switch bistable inverter (male receptacle Souriau series 8N45 connection or SAIB series NU25 103-400-K2) in it. 2. DETAILED DESCRIPTION - OPERATION Standard flange ends PN16 NF-EN1092.1 (2007) (ex 29203) DN ØD ØK ØG N ØF f b ØC L H Std 40 150 110 88 4 18 3 18 60.3 250 95 50 165 125 102 4 18 3 18 60.3 250 95 65 (*) 185 145 122 4 or 8(*) 18 3 20 88.9 250 105 80 200 160 138 8 18 3 20 88.9 275 110 100 220 180 158 8 18 3 20 114.3 275 125 125 250 210 188 8 18 3 22 141.3 300 135 150 285 240 212 8 22 3 22 159 300 150 200 340 295 268 12 22 3 24 219.1 325 175 (*) Flange 4 holes according to EN 29203 (8 holes with request according to NFEN1092-1) Standard flange ends ANSI 150lbs B16.5 (NF-EN 1759.1) DN ØD ØK ØG N ØF f b ØC L H Std 1 1/2 127 98.4 73.2 4 15.9 1.6 17.5 60.3 250 95 2 152 120.6 91.9 4 19 1.6 19 60.3 250 95 2 1/2 178 139.7 104.6 4 19 1.6 22.2 88.9 250 105 3 190 152.4 127.0 4 19 1.6 23.8 88.9 275 110 4 229 190.5 157.2 8 19 1.6 23.8 114.3 275 125 5 254 215.9 185.7 8 22.2 1.6 23.8 141.3 300 135 6 279 241.3 215.9 8 22.2 1.6 25.4 159 300 150 8 343 298.4 269.7 8 22.2 1.6 28.6 219.1 325 175 - optionally, models DN40-50-60 or 1 1/2-2 -2 1/2 can be produced 200mm long. -the used joints must be standard and adapted to the joint mounting. Page 4

Flow measurement The flow controller consists of : - a body of stainless steel 316L (1). - a diaphragm paddle set (2) of stainless steel 316L - a receptacle SOURIAU (4) ref : 8N45 1111 25 or a receptacle SAIB (4 ) réf : 251-103-400-K2 - a straight end + plug (5) ref : 8N45 1185 51 (optional) a straight end + plug (5 ) ref : 254-103-400-K2 (optional) - reed switch (6) for Souriau or (6 ) for SAIB. A paddle joined on the diaphragm, placed at right angle to the flow, moves depending of the flow value in the direction of the fluid. A magnet fixed on the paddle in an inox slot regulates the state of the contact when the cutoff value is reached. IMPORTANT NOTE: The flow controller is factory adjusted for a specific cutoff value. Do not change the position of the contact, which must be up to the stop against the internal wall of the box (red point of the contact with respect to the cover) Identify the type of receptacle on the Box and adapt the correspondent plug according to requirement of the site. For a possible replacement of the switch, it imperative to specify the model of receptacle installed on the box. 3. PIPE EXPLOITATION. - The installation of the flow controller can be performed on a vertical or horizontal pipe (position to be established with precision in the order). - In horizontal installation, the contact box must be located in the lower part. - Verify the direction of circulation of the fluid before installation (red arrow attached to the body) - Be sure that the fluid to be controlled does not contain solid or magnetic particles, which could impede the good operation of the device. 4. PREVENTIVE MAINTENANCE This device needs no special care except the maintenance in good operational state of the diaphragm-paddle set (for example, filters or traps for magnetic particles are to be installed when used with charged fluids). 5. REPLACEMENT OF THE CONTACT UNIT (6) OR (6') This operation does not need any isolation of the line or dismantling of the device. 5.1.DISASSEMBLY - Disconnect the plug (5) / (5 ) from the receptacle (4) / (4 ) - Remove the cover of the box (3) - Unwind and remove the two screws of the contact fixing flange - Unwind the four screws fixing the receptacle (4) / (4 ) on the box (3) - Take out the contact (6) / (6 ) + receptacle (4) / (4 ) unit - Remove the unit consisting of insulating support and contact from its frame - Using a SOURIAU extraction tool ref : 8400 448 or SAIB ref : 086-025-02, take out the three contacts from their insulating support. (See here) 5.2. REASSEMBLING - Take the spare contact with its three contacts (6) / (6 ) - Using an insertion tool SOURIAU ref : 8400 1475 or SAIB ref : 085-025-01 insert the contacts in their insulating support. - Install this unit in the receptacle (4) / (4 ) placing the actuator up to the stop in the deepest slot - Place and manually tighten the clamping cone and nut - Fix the receptacle (4) / (4 ) on the box (3) - Place and fix the contact using two screws and the fixation flange of the contact Important NOTE: During the installation of the reed switch in the box, its termination must be in contact with the internal wall of the box (red point of the contact facing the cover). - Mount the box cover (3) - Reconnect the plug (5) / (5 ) to the receptacle (4) / (4 ) - Check the correct operation of the contact with respect of the specified alarm flow value. If necessary, make another adjustment to obtain this value moving the contact box in the openings provided for this purpose. After the adjustment, make sure that the fixing screws of the box are tightened. Page 5

Flow measurement 6.ESSENTIAL SAFETY REQUIREMENTS These devices must be installed horizontally or vertically and fixed correctly on the piping. Sudden variations of valve areas or installation types causing flow perturbation must be avoided. Attention do not prestress the device during the installation on the piping. Before the installation, check the cleanliness of the piping. The pipes must be free of any solid particles. The valves must be progressively maneuvered to avoid any waterhammer effect or vibration. Never exceed the max. operating pressure of the device. Never exceed the max. operating temperature indicated on the device plate. Do not use the device for any other type of fluid other than indicated on the device plate. Do not use solvents when cleaning the protection box. Do not put the device under sudden temperature changes Regularly check the corrosion state of the device SAFETY RELATED TO TEMPERATURE This pressure equipment being a part of a unit, it is the responsibility of the integrator to take the necessary measures in order to ensure the protection against risks due to temperature (for persons but also the type of ambient materials in conformity with the specification of the device). Protection could be ensured, for example, by insulation of hot elements, by access protection systems, by any system adapted to the site of use and compatible with the regulations in force. Before any action on pressure equipment, the qualified and authorized operator must check if the present conditions : pressure, temperature, etc are compatible with the planned actions. In the case of equipment with alarm contacts, he must also take every precaution in relation to the use of these contacts : voltage, current, elements or machines regulated through these contacts, etc The seals should be replaced, if needed, and the tightening elements of bolts checked. OPENING AND CLOSING OF PRESSURE EQUIPMENT Before any action on pressure equipment, the qualified and authorized operator must make sure that the present conditions : pressure, temperature, etc are compatible with the planned actions. In the case of equipment with alarm contacts, he must also take every precaution in relation to the use of these contacts : voltage, current, elements or machines regulated through these contacts, etc The dismantling of elements necessary for the access to PE (Pressure equipment) must be performed using the proper tools. The reinstallation is performed in the inverse order to the dismantling. The seals should be replaced, if needed, and the tightening elements checked, etc. Before pressurization, the operator checks if all the safety rules (same for new devices) are respected.. The conditions of use must be in conformity with the indicated prescriptions. This equipment must not contain fluids of any other group but the one (or, possibly, several groups), for which it was designed. It is strictly forbidden to perform any temporary or definitive modification, or any operation susceptible of modifying its physical, mechanical, or metallic characteristics on any of its parts, without preliminary written approval of the manufacturer. Any modification with respect to all this information, susceptible of placing at risk the safety related to any use of the equipment, is done outside the responsibility of HOUDEC INSTRUMENT SAS. The user must check that before start-up the safety instructions related to pressure equipment as well as to the good operation of the adjoining elements are observed. This equipment is designed for static loads corresponding to the device own weight and to the specific constraints linked to pressure and temperature as defined in the technical specification. It is not designed for additional loads or constraints related to vibration conditions, except if special agreement has been made during the preliminary studies. SAFETY RELATED TO PRESSURE This pressure equipment being a part of a unit, it is the responsibility of the integrator to take the necessary measures in order to ensure the protection against risks of internal overpressure or those due to improper use. Protection could be ensured, for example, by installation of security devices (valves). The integrator must also perform the necessary actions in order to guarantee safety of personnel in case of interventions on the equipment (for example : installation of insulation devices, valves and elements of measurement of residual pressure, manometer or any other.) He can implement any other mean (or design principle) as far as the latter can guarantee a safety level that is compatible with the essential safety requirements requested by the directive 97/23/CE and/or the regulations in force. Page 6

Flow measurement 7. SPARE PARTS Reed switch (Drawing N 14842) with male contacts SOURIAU Spare part N PDR-00082 Reed switch (Drawing N 14842-10) with male contacts SAIB Spare part N PDR-00083 When ordering spare parts, it is very important to quote the precise serial number of the device to be repaired before providing the description of any removed part. 8. WARRANTY The contact is the only quickly exchangeable part. In order to reliably identify the precise references for these parts related to the type of construction, it is necessary to indicate the serial number, written on the label or the marking plate, attached to the device. Tel. Of the aftersale service to be contacted: France : +33 (0)4 70 59 81 81 Other countries : contact the local representative This equipment is delivered with a guarantee (please, refer to the contractual conditions of the order for the guarantee period). We attract you attention on the fact that the use of parts that are not in conformity either with the original parts, or with the requested standards, (materials certified according to harmonized standards, class, with respect to the standardized parts, bolting, flanges, connections ), may challenge this guarantee as well as the responsibility that may be associated to it. Page 7

Flow measurement Houdec Instrument S.A.S. Z.A. de la Tour ABREST France Tel: +33 (0)4.70.59.81.81. Fax: +33 (0)4.70.59.96.37. www.houdec.com copyright information Page 8