Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Similar documents
Accu-Tab PowerBase 3070AT by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3140AT by Axiall Corporation

Vessel Installation and Operating Manual

Installation and Operating Manual

Installation Instructions JATCO Environmental Protection Tank Model J-7000

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

Saline C 6.0 Junction Box

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

J Air and Water Kit Instructions Part# 02584

INSTALLATION AND OPERATION INSTRUCTIONS

Contact Chamber and PoolMoss Packs

Installation, Operation and Maintenance Manual

D Series Air and Water Kit Part# 02550

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

PC1131 Electric Air Compressor

ACCU-MIX 1200 / / 26270

453 Series Steam Heated Vaporizing Regulator

INSTALLATION AND OPERATION INSTRUCTIONS

Installation, Operation, and Maintenance Manual

Purifier for Vinyl Lined Pools

Model 9201E Tempered Water Blending System

Owner s Manual W Automatic Aboveground Pool Cleaner

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

ECONOMY POOL SUNSHINE IONIZER MODEL SPE INSTALLATION INSTRUCTIONS

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

PURITY INSTALLATION INSTRUCTIONS MODEL P40

FLANGED TWO-PIECE BALL VALVES

Cocoa Patio Pond with Lit Spillway

SERIES BB TRASH BASKETS

BS Series Basket Strainer

FLANGED TWO-PIECE BALL VALVES

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

HIGH PERFORMANCE POOL & SPA PUMPS

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Modular skylight warranty

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Operator's Manual. Model #PS Arch Chemicals, Inc Lake Park Drive Smyrna, GA PULSAR

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Model TWBS.SH Tempered Water Blending System

SPECIFICATIONS APCEPH1

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Installation & Instruction Manual For Portable Series R.O. units:

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

CSA Sample Draw Aspirator Adapter Operator s Manual

ASAHI/AMERICA EFFECTIVE: 12/01/08. Dimensional Guide. Halar (E-CTFE) Piping & Valves

SERIES BA TRASH BASKETS

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

ULTRA QUIET & OIL FREE

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Electronic Control Pump Instruction Manual

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

Electronic Control Pump Instruction Manual

Commercial Well Tank Installation Instructions

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

Installation and Operating Instructions

Operating Manual. Model BAC-30RT30/BAC-30DC

4-in-1 Professional Inflator Kit

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

HYDROVEX TTT Membrane Flow Regulator

Electronic Control Pump Instruction Manual

General Safety. All electrical work

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Shell & Tube. JATCO Inc. Operating Manual

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

KJ4000 Operating Instructions & Parts Manual NSN

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Yoke Block Instruction Manual

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

Please Do Not Return This Product To The Store!

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

FLANGED MULTI-PORT BALL VALVES

Vortex Dual. Refrigerant Recovery Machine

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

Interface Devices, Inc. Hydraulic Mini Mule

Back Pressure Regulator

RANDOM ORBITAL POLISHER INSTRUCTION MANUAL 3 in (76 mm) 11,000 RPM

92831 TEL: (714) FAX:

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

480C DUAL PERFORMANCE VALUE PACK

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

Model Series 63DL Differential Type Flow Controller

Transcription:

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The Acid-Rite ph Adjustment System is designed for use with Axiall Acid-Rite tablets only. DO NOT use ANY OTHER tablets. Chlorine gas release could result. 1 Revised 03-01-17

System Description Acid-Rite ph Adjustment System 2500 The Acid-Rite ph Adjustment System 2500 incorporates a Feeder that will accurately and reliably add a ph adjustment chemical to your water system. The system also incorporates a level controlled solution tank and pump to deliver the acid to the return line. The design allows only the lower tablets to be wetted and dissolved while the tablets above remain drier. ONLY use Axiall Acid-Rite tablets. Use of other tablets will void the warranty, void the NSF Certification and could increase the possibility of a chlorine gas release. 2

Installation (Figure 1) 1. Mount the System on a level surface. 2. Thread supplied Female adapter onto float valve inlet. 3. Use 1 piping or hose to connect from Return Line water supply to the feeder. Include a block valve and the supplied inlet filter. 4. A flow meter assembly and valve assembly are shipped separately to preven breakage in shipment. 5. Cement the flow meter assembly to the discharge of the pump check flow direction. 6. Cement the check valve and control valve assembly to the the flow meter assembly check flow direction. 7. Use 1 piping or hose from Valve Assembly to connect to Return Line delivery point AFTER the heater. Include a block valve. 8. There is an overflow port on the solution tank near the top. If desired, this may be plumbed to a drain. Use 1-1/2 pipe or hose. 9. Plug in the Power and Controller cords. 10. Test run system. Repair any leaks. FIGURE 1 Installation 3

Start-Up Instructions 1. Open inlet and outlet block valves. Water will flow through the feeder and fill the solution tank. 2. When inlet water stops flowing, open the Discharge Control valve a 2-3 turns. 3. Start pump with controller, and set flow at 1-2 gpm. 4. Shut down system, to prevent acid spashing while tablets are added. 5. Add Acid-Rite tablets to feeder. 6. Start system using the controller to add acid. 7. Monitor ph of pool and adjust flow through feeder as needed. Operation Instructions 1. Remove lid from Acid-Rite AR 2500 Feeder. 2. Add Acid-Rite ph Adjusting Tablets to the feeder. 3. Replace lid. 4. Check ph of water system and adjust flow as necessary. NOTE: When pool water circulation stops, flow to the feeder will stop. This will stop acid delivery. Troubleshooting System overflows. 1. Debris in the float valve. 2. Debris in the check valve. 3. Float valve stuck in down position. Clean float valve. DO NOT use any lubricant on the valve internals. Pump will not run. 1. Check power supply and connections, and controller 110v signal. 2. Check for 110 voltage across terminals #2 and #5. If voltage present, wiring or pump motor failure. 3. If no voltage, check pump contactor. Pump loses prime (solution tank drains) 1. Maximum inlet flow exceeded. To determine the maximum inlet flow rate, start by closing the discharge gate valve. Open the discharge gate valve in small increments. Remember to allow a few minutes each time to allow the flow meter to stabilize. If pump loses prime, maximum inlet flow has been exceeded. Shut down system for a few minutes (which will prime the pump), close back on the discharge gate valve and restart the system. Continue this process until the maximum inlet flow is determined. 4

Float Valve maintenance If valve becomes clogged with debris on a continuing basis, add a second filter to the inlet. Use the 60 mesh in the first filter then a 100 mesh in the second. The 100 mesh filter can be supplied by your specialist. Cleaning The system should not require any cleaning as it is delivering an acid product. Should cleaning be necessary, refer to the Safety Data Sheet for use of Personal Protective Equipment for handling acid solutions. Electrical Drawing 5

ACID-RITE SYSTEM LIMITED WARRANTY Axiall, a Westlake Company ("Axiall") warrants (subject to the below conditions) only its title to this water treatment system equipment (the "System") and that the System will be free of defects in materials and workmanship for a period of twelve (12) months from its original installation date. THIS IS THE ONLY REPRESENTATION OR EXPRESS WARRANTY THAT AXIALL MAKES AND ALL OTHER EXPRESS WARRANTIES UNDER STATUTE OR ARISING OTHERWISE IN LAW FROM A COURSE OF DEALING OR USAGE OF TRADE WITH RESPECT TO THE SYSTEM ARE DISCLAIMED. ANY IMPLIED WARRANTIES EXISTING AS A MATTER OF LAW SHALL NOT EXCEED THE DURATION OF THIS LIMITED WARRANTY. IN THE EVENT THE SYSTEM FAILS TO CONFORM TO THIS WARRANTY, AXIALL'S EXCLUSIVE OBLIGATION AND YOUR EXCLUSIVE REMEDY SHALL BE LIMITED TO, AT AXIALL'S OPTION, THE FURNISHING OF NEEDED REPLACEMENT PARTS OR THE FURNISHING OF A NEW SYSTEM (BUT THIS DOES NOT INCLUDE INSTALLATION OR THE COSTS FOR INSTALLATION). EXCEPT AS PROVIDED IN THE IMMEDIATELY PRECEDING SENTENCE, IN NO EVENT WILL AXIALL BE LIABLE UNDER ANY THEORY OF RECOVERY (WHETHER BASED ON NEGLIGENCE OF ANY KIND, STRICT LIABILITY OR TORT) FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES IN ANY WAY RELATED TO ANY USE MADE OF THE SYSTEM. Warranty Conditions. This Limited Warranty shall apply and be effective only if: (i) the System is installed and operated and maintained in accordance with this manual and the instructions accompanying the System; (ii) you, at your cost, promptly return the System or defective part to such location as may be specified by Axiall; and, (iii) only Acid-Rite ph Adjustment tablets are used in the System. If any of these conditions are not met, this Limited Warranty will not apply and you acknowledge and agree that your purchase of the System will be on an "AS-IS" basis without any warranty of any kind whatsoever having been provided by Axiall. You assume all responsibility and risk and liability arising from: (i) the unloading, installation, storage, handling and use of the System, including use thereof alone or in combination with other materials; (ii) the improper functioning or failure of unloading, installation, transportation or storage equipment you use, whether furnished or recommended by Axiall or not; and, (iii) the failure to comply with laws, rules and regulations governing storage, unloading, installation, handling, and use of the System. You will indemnify, hold harmless, and defend Axiall from and against any claim, suit, damage, cost, expense, fine, liability, or cause of action whatsoever, including reasonable attorney fees, on account of relating to, or arising out of the use, possession, installation or resale of the System. This Limited Warranty gives you specific rights, and you also may have other rights, which vary from jurisdiction to jurisdiction. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Acid-Rite is a trademark of Axiall, A Westlake Company 800-245-2974 6