CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

G-CEM 4100 Extractive Multi-Gas Analyser

PRODUCT CONFORMITY CERTIFICATE

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Model EXAxt AV550G. Averaging Oxygen Analyzer

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

User manual CF8-D/W-IN

FLAMMABLE GAS SENSOR/TRANSMITTER

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

CONTENTS OVERVIEWS PRODUCT INFORMATION

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Precision pressure sensor Basic version Model CPT6020

Columbus Instruments

Oxygen & Binary Gas Measurement and Analysis

HumiSys HF High Flow RH Generator

Autocalibration Systems For In Situ Oxygen Analyzers

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

FTC130 Transmitter. Operating Manual

Best Practice Guide, Servomex 2700

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Features. Description

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

User Manual. asense miii. / CO sensor with built-in general purpose controller

780S Ultra High Purity Series

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Datasheet: K-30 ASCII Sensor

NGN Series nitrogen generator

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

SERVOTOUGH Oxy (1900)

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Micro Motion 3098 Gas Specific Gravity Meter

AMT-Ex Dewpoint Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

AUTOMATIC HOSE TEST UNIT, TYPE SPU

LT GasAnalyzer beyond standards

GasSense NDIR User Manual

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Model PDT Dewpoint Transmitter

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

C-Flow Coriolis Mass Flow Meters

Laser Gas Analyzer LG2000. The Laser Technologies

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Electro-Pneumatic Converter YT-940 SERIES

Gas density monitor With integrated transmitter Model GDM-100-TI

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Technical Data Sheet MF010-O-LC

Used with Dissolution Tester for Fraction and Flow Measurements

High-performance submersible pressure transmitter For level measurement Model LH-20

Keeping It Simple. Gas Mixtures for Stack Emissions Monitoring.

Installation, operating and maintenance Instructions for Seemag bypass level indicator

SCIENCE LAB UTILITY CONTROLS

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Products for Cryogenic Applications

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

Digital Mass Flow Meters and Controllers for Gases

SM8200. SO2/NO In Situ Multi-Gas Analyzer

TH-1800-T TRX-700-CNG Converter

Pneumatic high-pressure controller Model CPC7000


Manual Oxygen Analyzer A4009T

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

Electrochemical Sensor

analytical bulk flow distance FLOW level pressure temperature industrial communication

BUYER S GUIDE AQUAlogger 530WTD

EasyLine Continuous Gas Analyzers. So smart, they re simple

This test shall be carried out on all vehicles equipped with open type traction batteries.

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Ultra High Purity Model 780S

FAS-W. Features. Applications. Automatic condensation hygrometer

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

High Pressure Breathing Air Compressors

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Operation and Maintenance Manual

Saab Seaeye Cougar XT Compact

Hand-held pressure calibrator with integrated pump Model CPH6600

High-performance submersible pressure transmitter For level measurement Model LH-10

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

UniCEM. Continuous Emissions Monitoring System

How to specify a product. Process Sensors and Mechanical Instruments

Highest Quality. Gas Chlorination Systems

Pressure Transmitters 36 F-27839

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

better measurement Simply a question of

Transcription:

Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Multi-species infrared absorption analyser Accurate, reliable and low maintenance technology Extractive system with full zero & span verification using certified gas Gas temperature and pressure sensors On board normalisation to standard reference conditions Automatic calibration and verification Analogue and digital outputs - Export of data to SCADA, DCS and historian systems

GCEM4100 Extractive Gas Analyser The GCEM4100 hot extractive multi-channel gas analyser is CODEL s industry-proven continuous emissions monitor for difficult applications. Designed exclusively for use on gas turbines or applications where the flue gas concentration is very low and the temperature is abnormally high. Three decades of development, knowledge and practical experience have been utilised to produce this advanced technology gas analyser which gives complete flexibility of use on process or emissions applications whilst delivering superb accuracy and repeatability at a competitive price. Heated Probe Many conventional extractive systems require the sampled gas to be cleaned and dried to a very high standard prior to analysis, invariably resulting in a high maintenance demand. Such elaborate pre-conditioning is not required; the GCEM4100 creates perfect duct conditions in a temperature controlled chamber within a separate free-standing, air-conditioned cabinet. Process conditions are extracted using a heated probe system which has an option of compressed air blow-back for excessively dusty applications. Once the sample has been drawn it is simply cooled (or heated) then transferred along a heated sample line, without further conditioning, to be measured using a CODEL multi-channel analyser housed in the cabinet. Environmental agencies demand that continuous emission analysers have the facility to prove their performance using known concentration audit gasses. The GCEM4100 provides the facility to automatically check and control zero calibration point using clean, dry compressed air or nitrogen. Where independent span checks are required, bottled gases of known concentration can be injected directly into the measurement chamber. GCEM4100 Gas Analyser The GCEM4100 analyser is capable of measuring CO, NO, NO2, NOx, SO2, CH4, HCl, N2O, CO2 and H2O simultaneously and with integral temperature and pressure sensors can compute fully normalised data directly in mg/nm3. The analyser can be easily incorporated into the CODEL SmartCEM system along with dust, flow and oxygen signals to deliver a complete emission monitoring solution capable of meeting today s tough legislative demands. Heated Sample Line

GCEM4100 Extractive Gas Analyser - System Arrangement Duct Wall Heated Probe Sample Line Air Conditioning unit GCEM4100 Extractive Gas Analyser - Options Central Data Controller (CDC) 1. Plug-in 4-20mA Input PCB 2. Plug-in Contact Input PCB 3. RS485 PCB for Modbus Output CODEL SmartCEM Software

GCEM4100 Extractive Gas Analyser & CEMS Panel - Overall Dimensions 800 400 367 1000 CODEL CEMS Panel 1800 800 GCEM4100 Note: All dimensions are in mm GCEM4100 Extractive Gas Analyser with Air Conditioned Cabinet - Overall Dimensions 1200 367 600 535 540 1000 457 349 2118

SmartCEM Software Detailed and customisable reports to meet Regulatory Agency requirements User configurable real-time and historical graphing facilities for data analysis Data export to popular applications such as Excel etc Multi-user networking capability Real-time normalisation of data Satisfies EN14181 QAL3 requirements Data storage on PC hard drive of at least 10 years Easy installation and set-up Intuitive operation Will operate on all Windows based operating systems SmartCEM Emissions Monitoring Software provides the complete solution to data gathering and analysis on CODEL-based monitoring systems. With a simple installation and set-up routine, the program takes only minutes to load and configure and comes with a comprehensive on-board help feature. Real-time Displays Using a serial link to communicate with the sensors, SmartCEM updates the live data screen every 30 seconds to keep the user aware of the current situation on plant, while alarms warn the operator of high emission levels. Data is displayed in numerous formats - ppm, %, mg/nm 3, mg/m 3, kg/hr assuming flow measurement is available etc. - and the change of format is instantaneous. Graphs A key feature of SmartCEM is the provision of real-time and historical graphs providing detailed analysis of emissions data. One useful feature enables the user to highlight a period of time on the graph and obtain the average emissions. Data is easy to read and is configurable to individual operator requirements. GSM Unit The GSM unit allows CODEL engineers direct access to any analyser in our range giving them full online remote diagnostic information for technical support.* This service can be offered for a nominal monthly charge * Network coverage can limit the use of this service

GCEM4100 Extractive Gas Analyser - Technical Specification Sensor Unit Gas Species Options Maximum 7 gases from: CO, NO, NO 2, NO x, N 2 O, SO 2, HCl, CH 4 and CO 2 Gas temperature, pressure and H 2 O for data normalisation are standard. Measuring units ppm, mg/nm³, mg/m³, % Response Time Less than 200 Seconds (T90)- MCERTS Specification Gas Temperature Below dewpoint to 1300 C, See probe options below Calibration Automatic and manual zero/span verification Gas Species CO, NO, NO 2, NO x, SO 2, HCl, CH 4, N 2 O CO 2, H 2 O Max Measuring Range 0-6000 ppm, higher ranges available on request 0-25% Accuracy +/- 2ppm or 2% of span 0.5% or 2% of span Resolution +/- 1ppm 0.1% Zero & span drift +/- 2ppm or 2% of span per month 0.5% or 2% of span Linearity +/- 2% of span 2% of span Repeatability +/- 5ppm or 1% of span 0.3% or 1% of span Ambient Temperature -20 C to +50 C Construction Corrosion resistant epoxy coated aluminium housing sealed to IP66 Heated Sample Line Single Core PTFE tube, non interchangable, self regulating Probe Standard Probe High Temp Probe Compliances EMC Low Voltage Analyser Cabinet Analogue outputs Logic Outputs Inputs Serial Data Construction Ambient Temperature Power Supply Air Dryer Services 0-600 C Stainless Steel 0-900 C Hasteloy, 0-1100 C Inconol, 0-1300 C Kanthol 89/336/EEC directive compliant 73/23/EEC directive compliant 4-20mA current outputs for each gas channel supplied, isolated, 500Ω load max, fully configurable from software. up to 8 x volt-free SPCO contacts, 50V, 1A max, configurable as alarm contacts 1 x volt-free SPCO contact, 50V, 1A max, for data valid signal 1 x 4-20mA for oxygen RS232 Mild steel construction powder coated to IP66 or 55 (Double door) -20 C to +50 C 90-132VAC or 180-264VAC by switch For clean, dry, oil-free air Power Mains 230 VAC, single phase, 50/60hz Air Requirement Clean and dry compressed air @ 4bar Consumption Air mover driven (Single line up to 60m) normal operation 100L/pm, calibration 110L/pm Pump driven (Single line over 60m) normal operation 5L/pm, calibration 30L/pm Optional Items Central Data Controller For connection to additional SmartCEM systems Plug-in PCB 4-20mA Input PCB Plug-in PCB Contact input PCB Plug-in PCB RS485 PCB for Modbus Output Software CODEL SmartCEM Software - See SmartCEM software data sheet CODEL International Ltd Station Building Station Road Bakewell Derbyshire DE451GE United Kingdom Tel : +44 (0)1629 814351 Fax : +44 (0)8700 566307 Web : Email : sales@codel.co.uk Distributor