White Paper August , Rev AA

Similar documents
INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Issue Date: Effective Date: Supersedes: V-15 (rev. 2)

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package

Vehicle-mounted meters, pump supplied

deltaflowc deltaflowc Venturi or Probe

QuantityWare Working Paper. NGL & LPG Measurement Standard Comparison

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

H&D Fitzgerald Pressure Pyknometry System Mark 5

Ron Gibson, Senior Engineer Gary McCargar, Senior Engineer ONEOK Partners

OIML R 71 RECOMMENDATION. Edition 2008 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Fixed storage tanks. General requirements

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Organisation Internationale de Métrologie Légale

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Oil Calculator Pro User Manual 2014

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

Electronic Volume Correctors

THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS

Truck-mounted Mass Flow Metering for LPG Delivery

CALIBRATION AND TRACEABILITY: ITS IMPORTANCE IN THE GAS INDUSTRY

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Cover Page for Lab Report Group Portion. Pump Performance

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Type , , S2.20 Specialized test procedure Procedure for testing LPG bulk meters using a vapour displacement prover

HEATEC TEC-NOTE. Setting Siemens Pressure Transmitter. Used on Heatec Vertical Asphalt Tanks. Publication No , Revised

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

Drilling Efficiency Utilizing Coriolis Flow Technology

Fluid Machinery Introduction to the laboratory measurements

Ships tank - General requirements

Sartorius CCL kg Prototype Mass Comparator

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Special Documentation Proline Promass 300 Modbus RS485. Petroleum Application Package MANUAL

How to specify a product. Process Sensors and Mechanical Instruments

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:

GMC-I Service GmbH Calibration Center

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

628 Differential Pressure Decay Leak Tester

Instrumentation & Data Acquisition Systems

MEASUREMENT BEST PRACTICES FORIMPROVEDREFINERY SAFETY, AVAILABILITY & EFFICIENCY

Technical Information Conducal CLY421

API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks

2016 Spring Committee on Petroleum Measurement Standards Meeting March 14-18, 2016 Hyatt Regency Dallas at Reunion Dallas, Texas

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

FTC130 Transmitter. Operating Manual

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

Pressure Metrology in Mexico

KENYA ACCREDITATION SERVICE

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Chapter 22 Testing Protocols

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Traceable calibration of automatic weighing instruments in dynamic operation

Courses of Instruction: Controlling and Monitoring of Pipelines

Next Generation Quartz Pressure Gauges

ISO INTERNATIONAL STANDARD. Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor

Case Study Results on Natural Gas Custody Transfer Measurement with Coriolis Meters in Saudi Arabia

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

Pneumatic high-pressure controller Model CPC7000

NEW VERSAFLOW CORIOLIS

Application Note AN-107

Pneumatic high-pressure controller Model CPC7000

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

Level MEASUREMENT 1/2016

SAUTER FK Version /2016 GB

Precision pressure sensor Basic version Model CPT6020

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Mass Flow Controller (MFC) for Gases

PM105 PRESSURE METER USER S MANUAL

SPE The paper gives a brief description and the experience gained with WRIPS applied to water injection wells. The main

2014 Programme of Training Courses in Measurement & Calibration

InstrumentationTools.com

STANDARD PROCEDURE OF A TIGHTNESS TEST OF A SOLAR COLLECTOR BOX. (EUROSUN 2000 SOLAR CONGRESS)

Oil and Gas Custody Transfer

AC : A LABORATORY EXERCISE TO DEMONSTRATE HOW TO EXPERIMENTALLY DETERMINE THE OPERATING POINT FOR A FAN

Pressure is our Business

Conversion factors for Thermal Mass flow meters for different operating mediums: An Experimental study

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Online data sheet FLOWSIC30 GAS FLOW METERS

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

Supplementary Certificate of Approval. No S433

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms *

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

OIL AND GAS INDUSTRY

Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format

CUSTODY TRANSFER OF FLUIDS IN MALAYSIA

Manual of Petroleum Measurement Standards Chapter 3 Tank Gauging

SIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15

Road and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July

Micro Motion Multiphase Applications

Transcription:

Section 1 Automatic Tank Gauging in Custody Transfer Applications Abstract Today Automatic Tank Gauges (ATG s) are commonly used world wide for custody transfer of petroleum products. International standards from both ISO, API and OIML describe the requirements on the equipment for use in custody transfer applications. This document gives a summary of the performance requirements in these standards, how they are adopted for legal metrological control in various countries. Further, the document describes the components in an ATG system used for custody transfer, and expected performance on level, temperature, density and volume. Also, an ATG system is compared with flow meters and it is briefly discussed when ATG s or flow meters may be the best choice. World wide view on using ATG systems for custody transfer Automatic Tank Gauge (ATG) systems have been used for custody transfer at least during the last 50 years. The technology has been refined a lot over these years, and even though the first float operated level gauges still can be seen in some use today, they are hardly used for custody transfer purposes. The major technology in custody transfer based tank gauging purchased today is based on highly accurate radar level gauges. One example is the Rosemount Tank Gauging system, which has an intrinsic accuracy of 0.5 mm over 30 meters measuring range and high accuracy inputs for temperature and density measurement. Even though transfers are often based on static level measurement, there is often a conservative approach in the petroleum industry when it comes to using an ATG for determination of a transfer instead of manual hand dip. This is despite the fact that a hand dip rarely is capable to compete in accuracy with a custody transfer class ATG system. Much of this is probably related to tradition and conservatism in the industry, but also to the fact that it is often required to have an independent party to perform the hand dip at a transfer. For manual hand dip this is simple to arrange, and an independent surveyor is just called in for the job. If a tank gauging system shall act as an independent measuring system, it implies that someone has to guarantee its independence. This requires an organization which supervises the equipment, and in most countries this is performed by the national metrological authority. Often the requirements on the equipment are formulated in a national law, i.e. the transaction is defined to be legal. There are today certain differences between countries how common it is to have legal custody transfer based on ATG s. Countries which have defined requirements on legal custody transfer for ATG s are: - Most European countries including Russia - Many countries in Asia (China, India, Indonesia, Malaysia, Thailand etc) - A few countries in Latin America Countries which have no defined requirements for legal custody transfer are: - North America - Middle East countries In USA, API has defined requirements on ATG s used for custody transfer (API chapter 3.1B), but there is today no authority which certifies equipment or supervise the use of it. In USA custody transfer is more defined as an activity which is a mutual agreement between a buyer and a seller, without involvement of a supervising party. There is however a lot of discussions going on within API, to go in the direction to accredit laboratories for certifying equipment which fulfills requirements according to API ch. 3.1B. So far however, no ATG systems have been certified. In Europe, there is a long history and tradition to use ATG s for custody transfer. Metrological institutes are most often involved, and the testing and supervision of the equipment is extensive. Countries and institutes which could be mentioned to have a high reputation and competence in ATG s used for custody transfer are: - PTB, Germany - LNE, France - BMS, Belgium - SP, Sweden - NMI, the Netherlands - GOST, Russia 2

Section 1 The typical procedure an ATG must pass to be able to be used for legal custody transfer is: A pattern approval test. This test is often quite extensive where the system is tested for intrinsic accuracy, influence on measurement from ambient temperature, humidity, electrical emission, electrical immunity etc. The pattern approval will also specify limitations of the use of the equipment (e.g. measuring range etc), and limitations on installation. Delivery test record. This test is often quite extensive where the system is tested for intrinsic accuracy, influence on measurement from ambient temperature, humidity, electrical emission, electrical immunity etc. The pattern approval will also specify limitations of the use of the equipment (e.g. measuring range etc), and limitations on installation. Installation test. When the equipment has been delivered to customer, a local representative from the metrological authority or an independent surveyor checks the installation and calibration on tank. After successful inspection, the equipment is metrologically sealed and the equipment is ready to be put in operation. The metrological sealing prohibits any change of the calibration without breaking the metrological seal. Subsequent verification. Performance of the equipment is checked at certain intervals on the tank. Common intervals are 1-2 years. The procedure may vary a bit between different countries. In France e.g., the equipment must also prove its suitability to perform in field, and it is required to test three systems during a time period of 3 months before approval is granted. In general there are very few suppliers that fulfill testing and requirements as above. In France, as an example, there is only one type of radar based level gauge that is approved. Of the above mentioned, the OIML R 85 edition from 2008 can be considered as the most developed and important, since it has been accepted as national requirements in a large number of countries. More or less all European countries have adopted OIML R 85, 2008 as the base for legal custody transfer, and it is widely spread also in Asia, Australia and some countries in Latin America. OIML R 85 has the advantage that it precisely specifies the tests that a system must perform to be accepted. Since OIML R 85 also is a harmonized standard, it is also sufficient to test at one accredited laboratory, and the test report will then be accepted in other countries. API standards are mostly recognized in US, but also frequently used in the Middle East. The primary task of the API standards is to give important guidelines for installation, calibration etc, which is not the focus in OIML R 85. Until now, there is no dedicated test laboratory which tests that ATG s fulfills the custody transfer requirements as specified in API standards, and it is more up to the user to verify this by himself. ISO 4266 is very similar to API ch 3.1B, ch 3.3 and ch 7. As the API standard, it gives general guidelines for the use of ATG for custody transfer. Performance requirements have during the last years, to a certain degree, been harmonized between the standards above. The table below shows requirements on temperature and level for the different standards when used for custody transfer. Level lab Level installed Temp lab Temp installed OIML 1 mm 4 mm - - API 1/16 inch 3/16 inch 0.5 F 1 F ISO 1 mm 4 mm 0.25 C 0.5 C Standards for ATG s used for custody transfer There are primarily three standard organizations that specify requirements on ATG s used for custody transfer. These, and the standards are: OIML R 85, 2008 (Organisation International Metrologie Legal) API ch 3.1B, ch 3.3, ch 3.6, ch 7 (American Petroleum Institute) ISO 4266, part 1-6 (International Organisation of Standards) 3

Section 1 Which are the components in an ATG System used for custody transfer? Figure 1 shows a typical ATG system that is used frequently for custody transfer applications in many countries. The necessary components in an ATG system used for custody transfer are: 1. Automatic Level Gauge (ALG), for measurement of the level at start and end of transfer. 2. Automatic Temperature Transmitter (ATT), for measurement of average product temperature at start and end of transfer. 3. Tank strapping tables for calculation of Observed Volume 4. Density measurement of the product, for calculation of Standard Volume. Figure 1. The Rosemount tank gauging system Smart Wireless Gateway 5900S THUM 2240S 2410 5900S 5400 2240S 5300 5900S 644 644 3051S 565 765 5300 2160/65/75 Field Communication Unit 2410 2410 5900S Radar Temperature Transmitter FBM 2180 2120 Liquid Level Switch 5400 Radar Level Transmitter 1 Fn 2 4 3 5 7. Rx On - TERM - Off 2180 Field Bus Modem Alternative Connections to DCS 9-5300 Guided Wave Radar 2230 Graphical 644 Temperature Transmitter with 65 Single Point Sensor Lo - GAIN - Hi 6 8 0 Tx Ext. pwr 2240S Multi-input USB Field Communicator Level Gauges 2410 Tank Hub 2410 RS-232 2230 Field Display www Smart Wireless THUM Adapter TankMaster PC workstation in network TankMaster.net 3051S Pressure Transmitter 565 Mutiple Spot Temperature Sensor 765 Mutiple Spot Temperature and Water Level Sensor Figure 2. A Hybrid Tank Gauging System FBM 2180 Rx Tx USB RS-232 Ext. pwr Rosemount TankRadar Lo - GAIN - Hi On - TERM - Off The density may either be measured manually from samples which are analyzed in laboratory, or automatically measured by connection of a high precision pressure transmitter to the system. In the latter case the ATG system is a Hybrid Tank Gauging System, and there is no need for manual sampling of density, see figure 2. Calculation of observed and reference density is then performed in the control room PC. A Hybrid Tank Gauging system can give: Custody transfer accuracy on Level, Temperature - Custody transfer accuracy on Density - Custody transfer accuracy on Standard Volume - Custody transfer accuracy on Mass In case the tank is non-atmospheric, an additional pressure transmitter is necessary for measurement of the tank atmosphere pressure. 4 www. s ol ar e s fl or i da. c om

Section 1 Calculations The calculations in an ATG system follows international standards and are summarized in the following flowchart: (TCT=Tank Capacity Table) Calculated value Total Observed Volume Gross Observed Volume Gross Standard Volume Net Standard Volume Weight in Air Input data Level, temperature,tct table, of weight, observed density, tank wall temperature Free water level,tct table Reference density, average product temperature, API tables Base Sediment and Water Air density For a normal custody transfer situation some of the above mentioned calculations may not be necessary, e.g. it is unlikely that free water is involved since a transfer usually is stopped before the level is close to the free water in a tank. Uncertainty in an ATG system The installed uncertainty of an ATG system depends on a number of factors like; the intrinsic accuracy of the transmitters, uncertainty due to the selected installation method, uncertainty in the Tank Capacity Table (TCT) etc. Realistic uncertainty figures in level, average product temperature, and density can be estimated to: Uncertainty in Level: ± 2 mm This assumes a high performance custody transfer level gauge with proven performance. The method of installation is important, where the installed level gauge must be rigidly mounted to the most mechanically stable point of the tank. This is normally achieved by installing the level gauge on a still-pipe, which either is mechanically fixed to the tank bottom or the lower corner between tank wall and tank bottom. For further installation guidelines see API ch. 3.1B. Certain corrections may be necessary to perform to achieve 2 mm installed accuracy like correction of thermal expansion of still-pipe etc. Corrections like this are normally available in these types of level gauges. Level uncertainties in transfers are affected by the fact that a custody transfer is a difference measurement, i.e. the difference in level at start and at end of transfer is measured. Some types of errors will thereby be cancelled out, e.g. an offset error of the level gauge will be the same before and after transfer, and will thereby have no (or very little) influence on the transferred batch. Uncertainty in Average product temperature: ± 0.3 C To achieve 0.3 C installed accuracy, a multi-spot RTD with sensor elements at various heights in the product is in most cases required. A stable electronic temperature conversion unit converts the resistance value to digital format, and the electronics should be designed for having full accuracy at all ambient temperature conditions. Uncertainty in Density measurement: ± 0.5 1.5 kg/m 3 Figures on accuracy for manual density sampling is often in the range of 0.5 kg/m 3. The actual accuracy of just the laboratory measurements is better, but handling of the sample on the tank roof, representativity of sample etc may introduce additional errors. For automatic measurement with the hybrid type system, the accuracy is mostly determined by the precision of the pressure transducer. The accuracy will also vary depending on the liquid level in the tank, i.e. at low liquid levels the accuracy will deteriorate, since offset drift in the pressure transmitter will affect the reading more than at high liquid levels. Typical accuracy figures which are achievable with standard pressure transmitters are around 1,5 kg/m 3 at 3 meter liquid level (with better results at higher levels). The main impact density has on the transfer calculations is when using API tables for calculation of Volume Correction Factor (VCF) and standardized volume. However, the API tables are not very sensitive to density variations. In most areas of the API table one can vary the density approx. 7 kg/m 3 without any visible change in the last decimal of the VCF figure. An example of this is shown in figure 3, where density can vary from 739,4 746,9 kg/m 3 without affecting the value of the VCF figure. Uncertainty in Tank Capacity Table: 0.01% - 0.10 % The precision in the Tank Capacity Table varies with respect to which calibration method that has been used, and the time since the calibration was performed. Old calibration methods often states an uncertainty of 0.10 % in the TCT, but recent calibration methods based on the EODR method has shown figures as low as 0.01 % 0.02 %. The fact that custody transfer is a difference measurement also affects the uncertainty in the TCT and errors are to a certain degree cancelled out. Particularly on small transfers one can expect that this cancellation effect has a large impact and uncertainty is far better than the figures above. 5

Section 1 Figure 3. Effect on VCF by uncertainty in density. Density @ 739.0 739.4 741.3 742.0 742.8 745.0 745.8 746.5 746.9 747.2 15 C (kg/m 3 ) Uncertainty -0.80-0.75-0.50-0.40-0.30 0.00 0.10 0.20 0.25 0.30 (%Reading) VCF Computed 0.9938 0.9939 0.9939 0.9939 0.9939 0.9939 0.9939 0.9939 0.9939 0.9940 Volume uncertainty, an example The uncertainty in volume depends on the shape of a tank, and has to be calculated for each tank type individually. To give some idea of what can be expected the following can serve as an example: A normal shaped tank 20 m high, 36 m in diameter has a volume of 20 000 m 3 (i.e. each mm in level corresponds to 1 m 3 ). When completely emptying the tank the uncertainty can be estimated as: 1. Uncertainty from level gauge (2 mm) corresponds to: 2 m 3 2. Uncertainty from temperature/density measurement corresponds to approx 4 m 3 at full tank, and to 0.4 m 3 at 2 m level. Worst case is full tank (temp 0.3 C, 0.5 kg/m 3 ): 4 m 3 3. Uncertainty from TCT (0.02 %) corresponds to: 4 m 3 Total estimated uncertainty of transfer: 6 m 3 (root sum square value) If one compares an ATG system with a flow meter one could estimate what accuracy is required by the flowmeter to have the same uncertainty. In this case the 6 m 3 corresponds to 0.03 % of the 20 000 m 3, i.e. the flow meter must have an accuracy of 0.03 % including conversion to standard volume, to be able to match the ATG system. Flow meter or ATG system for custody transfer There is often a discussion if metering or ATG should be used for determination of a transferred batch size. In practice it is common that both are used, and the figures from metering is compared with the result from the ATG measurement. However both methods have their characteristic pro s and con s, and in general one could say that at large batches there may be better performance with an ATG system compared to metering and the opposite at small batches. The performance may be illustrated schematically as in figure 4. The Pro s and Con s in different applications may be illustrated as below: (+ indicates preferred) ATG Meter Crude receipts/sales, large batch + - Crude transfer via pipe line - + Crude, trucks, tankcars - + Refined products receipts/sales + - Refined products, trucks, tankcars - + No service capability for meters + - Internal transfer (non-custody) + - Mass based transfer + +/- LPG +/- +/- Asphalt, lube oil, viscous products + - Cost * + - *Purchase and maintaining ATG s are generally cheaper compared to meters. Figure 4 Performance Flowmeter Batch size Automatic Tank Gauge 6

Section 1 Where the intersection of the two curves is located varies between different tanks, where the shape of the tank has certain influence. There is however also a lot of other factors that may influence the performance, and in general one can say: ATG s may not perform well if - Batches are small - Tank Capacity Table is old or badly strapped - Tanks are deformed or mechanically unstable Meters may not perform well if: - Batches are large - Product contains abrasive material which tears mechanics - Product is viscous (bitumen, lube oil, waxy crude etc) - There is a lack of proper calibration facilities Particularly the last point above may be considered. Calibration of an ATG system is normally very simple and low cost compared to meters which requires complex and expensive equipment. An ATG system is normally required also for other purposes. These may be: - Operational Control - Inventory Control - Mass balance and Loss control - Leak alarm If we assume there is an ATG system installed for purposes as above, one could estimate the additional cost for also using the ATG system for custody transfer. There is of course a bit higher price on a custody transfer class ATG system compared to a less well performing system. However, the life time of an ATG system is often very long with an average of maybe 15-20 years. In this long time perspective the additional investment in better performing equipment will be more or less negligible. Also, the procedure of supervision of the performance (subsequent verification) when installed on a tank is limited to some hour per year by an independent resource. The total overall additional cost to have an ATG system in custody transfer shape can therefore be considered low. The status of the Tank Capacity Table should also be considered. In particular it could be well worth to consider a re-strapping of an old tank according to new modern methods especially if the strapping was made in the far past. The cost for re-strapping may not be very high, and it may be well motivate against the measurement error in product volume that can occur on just one single emptying or filling operation of a tank. 7

Emerson Process Management Rosemount Tank Gauging Box 130 45, SE-402 51 Gothenburg, SWEDEN T: +46 31 3370 000 F: +46 31 25 30 22 E-mail: sales.rtg@emerson.com