Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

Similar documents
Operating instructions for. For visualization of your measurements

SHIMADZU LC-10/20 PUMP

ALGE DIVE! ALGE. ALGE-TIMING GmbH & Co

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Instruction Manual. BZ7002 Calibration Software BE

Operating Manual BCP-O2. BCP X-large Aluminum IP65. BCP regular with PA 6 housing. Rev

PC Configuration software for Discovery MkVI v 1.03 User guide

Operating Manual BCP-CO. BCP X-large Aluminum IP65. BCP regular with PA 6 housing. Rev

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

Calibration Procedure

Real-time gas analysis and software for the management of bioprocessing

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Calibration Procedure

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Pocket Oxygen Meter FireStingGO 2

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Pneumatic high-pressure controller Model CPC7000

The ICC Duckworth-Lewis Calculator. Professional Edition 2008

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

The ICC Duckworth-Lewis-Stern calculator. DLS Edition 2016

KIV-SACS Safe automatic calibration system:

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

RM-80 respiration monitor

SDM-2012 Docking Station Standalone Configuration Operator s Manual

SOLUBILITY OF A SOLID IN WATER

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

AX5000 Operational Manual

Boyle s Law: Pressure-Volume Relationship in Gases

Oxygen Meter User Manual

TR Electronic Pressure Regulator. User s Manual

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc.

KEM Scientific, Inc. Instruments for Science from Scientists

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Start the Polars program and load this file by using the explorer tab on the left side. You will get following picture:

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Tru Flight TRUFLIGHT INSTALLATION GUIDE TRUGOLF.COM

Armfield Distillation Column Operation Guidelines

Relative Humidity Calibration Kit

SPLIT HOPKINSON PRESSURE BAR OPERATIONS MANUAL 5/9/2014

Pneumatic high-pressure controller Model CPC7000

Tennis...32 Stay above...34 Decimal...36 Bundesliga simulator...38 Shooter management...41 Installation...43 Registration...45 Where do I get the

English. English. Predictive Multi Gas for

5890II GC Standard Operating Procedure 9/2/2005

Window and Door Measurement System

Operator s Manual. Rev F 8/29/ O Neil Rd, Macedon NY Telephone: (315) Fax: (315)

DDR Dive Data Recorder Manual - Rel /12

Figure SM1: Front panel of the multipatcher software graphic user interface (GUI) at the beginning of multipatcher operation.

Mass Flowmeters. Mass Flowmeters for Gases

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Lesson 12 New Procedure PULMONARY FUNCTION I

Experiment HS-2: Breathing and Gravity

Laboratory Mortar Mixer (Testing)

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

MoLE Gas Laws Activities

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Automated Liquid Handling Station

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

Software for electronic scorekeeping of volleyball matches, developed and distributed by:

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

New Cortex Software User Guide

Diver-Pocket Diver-Pocket Premium

QRAE II Quick Reference Covers Diffusion & Pump Models with Firmware Version 3.12 and higher

NCSS Statistical Software

Heavy Duty Dissolved Oxygen Meter

Wickets Administrator

Page 2 of 46 Prepared by: Engr. Ram Sankar

PosiTector UTG, UTG-STD & UTG-ME

RUNNING A MEET WITH HY-TEK MEET MANAGER

TOMI PRO MODEL PERSONAL MODEL

BIT User Manual. 1. About this manual. 2. Know your BIT 1.1. WARNING System Components

ACQUIDATA FAMILY CALIBRATION PROCEDURE CALIBRATION CHECKING

Mapping a Magnetic Field. Evaluation copy. Figure 1: Detecting the magnetic field around a bar magnet

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

Viva TPS. TS11/15 Total Stations Check and Adjust Procedure. October Summary

Inspection User Manual This application allows you to easily inspect equipment located in Onix Work.

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

Race Area Analyzer Solent

XC2 Client/Server Installation & Configuration

Calibration Procedure

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

iworx Sample Lab Experiment HE-4: Respiratory Exchange Ratio (RER)

SmartMan Code User Manual Section 5.0 Results

D-OptoLogger Dissolved Oxygen Logger Operation Manual

MP15 Jockey Pump Controller

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Inspection User Manual

Please note. Right now, the ongoing version of emax (3.9C) is not already completely compatible with the newest firmware version of Shimano!

iworx Sample Lab Experiment HE-5: Resting Metabolic Rate (RMR)

FTC130 Transmitter. Operating Manual

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Lung Sound Auscultation Trainer LSAT

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Microsoft Windows Software Manual for FITstep Stream Version 4

Transcription:

Operating Manual BACVis Manual BACVis for Sensors and MilliGascounter Rev.150728001

Contents 1 ABOUT THIS DOCUMENT... 2 1.1 Function... 2 1.2 Target group... 2 1.3 Symbols used... 2 2 SYSTEM REQUIREMENTS... 3 3 INSTALLATION OF BACVIS... 4 4 FUNCTIONS... 4 4.1 Start BACVis... 4 4.2 Input by user... 5 4.2.1 Select Com-Port, sensors and MilliGascounter... 5 4.2.2 Start the measurements... 6 4.2.3 1-Point calibration (Autocalibration)... 8 4.2.4 Stop the measurement... 9 5 DISPLAY... 9 5.1 Concentration... 9 5.2 Volume... 11 5.3 Highlight a curve... 12 5.4 Zoom... 12 Rev. 150728001 1

1 About this document 1.1 Function This operating manual provides you with all of the necessary information for the use of the BACVis software. Please read the operating manual before starting operation. 1.2 Target group This operating manual is intended for use by trained specialist personnel. The contents of this manual must be made available to personnel and followed by them. 1.3 Symbols used Danger! This symbol indicates a situation that is possibly dangerous. Failure to observe the safety instructions can result in personal injury. Caution! The symbol indicates the possibility of damage to property. Note! This symbol indicates helpful additional information. 1 Action sequence Numbers indicate steps to be performed in sequence. Rev. 150728001 2

2 System requirements You need the following components: BACCom12 for up to 12 gas sensors Sensors (CH4, CO2, O2 etc.) Computer with min. 1,6 GHz and 512 MB RAM Windows XP or newer One free serial port 100 MB free disk space Monitor with a resolution of 600x800 pixel Optional BACCom 12CB for 12 MilliGascounter (precision volume meter) Rev. 150728001 3

3 Installation of BACVis To install BACVis you have to create a new directory for example with Windows-Explorer that called BACVis. Then you copy the file BACVis.exe from disk to this directory. The installation is completed. Using the program you double click BACVis.exe or you create a link on your desktop. During the first measurement the measuring data are saved in the directory /data. 4 Functions 4.1 Start BACVis Fig. 1 Start Windows-Explorer and double-click on the symbol BACVis.exe or click on your link on the desktop and the program will start. It s looking for a connected BACCom 12, BACCom 12CB and the sensor heads. Rev. 150728001 4

4.2 Input by user 4.2.1 Select Com-Port, sensors and MilliGascounter With first use the COM-Ports have to be configured. The Com-Port selection has to be done on the Option/Settings in the shown window. Further you can minimize the number of heads. BACVis will only look for the set number. With the next checkbox you specify the data acquisition interval. Selecting the Counterbox will activate the connected MilliGascounter. Please make sure to enter each specific serial number and calibration factor (C1-C3) into the given fields for each MilliGascounter according to the BACCom Counterbox. Serial number and factors can be found on the data sheets for MilliGascounter. Confirm by applying OK button. Take care that the milligascounter are connected in the same order as input here! The shown volume is normalized to 273,15K, 1,013 bar and dry gas. Fig. 2 COM-port Max. number of heads Counterbox Intervall Counter calibration factors Selection of the Com-port Number of connected sensors Input of the proper number minimizes the search time Data acquisition of the volume if BACCom 12CB and MilliGascounter are connected The first port of the BACCom 12CB will be allocated to the first gas sensor! Selection of the measuring interval (2 minutes are recommended!) Input of the Serial number (SNR) and the three calibration factors (certificate at the bottom side of the counter) of the MilliGascounter for the accurate display of the volume The shown volume is normalized to 273,15K, 1,013 bar and dry gas. Rev. 150728001 5

4.2.2 Start the measurements With Task/New a new measurement could be started. Through selecting the check box in front of the sensors these are activated for this measurement. If the option Counterbox under Options/Settings is selected the MilliGascounter (connected at BACCom12 CB) are allocated to the sensors (Sensor 1 = Counter 1). The sensors will need to heat up 30 minutes until you can start the measurement. Attention! If you check the checkbox Autocalibration the sensors need to be exposed to the specified calibration gas as described in your data sheet. If you are not using the right gas, wrong measuring results will occur! For a normal measurement uncheck this checkbox! Fig. 3 Rev. 150728001 6

Heads Temperature Integration interval Measuring Interval Autocalibration Reset counter Comments to task Selection of the connected sensors Input of the temperature that is used during the measurement with fermenters and sensors. By means of this value the dilution effect through humidity will be compensated at the gas sensors Possibility for the smoothing of the measured data (The integration time is 16 seconds. 1 = 16, 2 = 32, 3 = 48) The adjusted standard interval is one minute. To change these between 20 seconds and 120 minutes you could click on to arrows in the field Measuring interval Activating this check box the sensors will do a zero point adjustment. This lasts 30 minutes and the sensors have to be exposed to a specified gas. See the data sheet of your sensors to find out the right gas. Reset of the counter. Because the counter has an integrated memory this is necessary if you starts a new measurement. If you computer has a shut down the measurement could be continued without activating this check box. The produced volumes will be stored continuously. The first line is the name of the measurements displayed in the headline of the measuring window. In the second and following rows you could write your personal notes. Rev. 150728001 7

4.2.3 1-Point calibration (Autocalibration) The 1-poimt calibration is a zero adjustment of the connected and activated sensors. It is necessary each month. In addition to that, the head is heated to avoid condensing humidity. In order that mechanical difference and temperature changes do not affect the results the autocalibration is done, which takes 30 minutes. The heads will be calibrated e.g. at ambient air (0,04 Vol.% CO 2, 0,00 Vol.% CH 4 ). Please note your data sheet to find the specification of your calibrating gas. Wrong concentrations in the gas will cause wrong measuring results. Therefore it is very important that you do not breath into the measuring adapter or in the sample vessel because the result will be high concentrations of CO 2 and you will receive false measuring results. If possible the autocalibration should be done in a well-ventilated room. During the autocalibration the measuring window appears. Fig. 4 At the bottom line you can see how long the calibration procedure is running any more. After it is ready the normal measurements continues and the measured concentration of the CH4-sensors will be shown in the graph and next to the sensor IDs. Rev. 150728001 8

4.2.4 Stop the measurement To stop the active measurement close the window (cross at the right top of the active window) The measuring data will be saved in the directory C:\. \Data in the following format: Measurement begin 01.01.2002 at 12:00:01: File format: 020101120001.dat Note! You can copy the file to work with the data while the measurement is running. The measurement does not have to be stopped. 5 Display 5.1 Concentration After the measurement is started the data are visualized like shown in the figure below. The window will be labelled like you do in the box for comments (Chap.4.2.2) Fig. 5 Rev. 150728001 9

At the left side the concentration (Vol.%) is shown. The bottom axes show the time in minutes. To view the produced volumes (MilliGascounter you could click (left mouse button) on the curve in the graph or in the legend. Afterwards you could see the belonging volume in the right corner of the window bottom. To view the volume curve click on the left Y-axis (concentration) and the window will change into the volume mode. Clicking again the mode will change back to the concentration mode. Rev. 150728001 10

5.2 Volume At the left side the produced Volume (ml) is shown. The bottom axes show the time in minutes. To view the corresponding gas concentrations you could click (left mouse button) on the curve in the graph or in the legend. Afterwards you could see the belonging concentration in the right corner of the window bottom. To view the concentration curve click on the left Y-axis (produced volume) and the window will change into the concentration mode. Clicking again the mode will change back to the volume mode. The shown volume is normalized to 273,15K, 1,013 bar and dry gas. Fig. 6 Rev. 150728001 11

5.3 Highlight a curve Each display of heads is shown as a coloured line that can be highlighted through clicking the line with the left mouse button or clicking the head at the right side of the window. To undo this highlight click on another part of the window. 5.4 Zoom Inside the measuring window it is possible to enlarge the desired area of the curve by pressing the left mouse button and simultaneous movement of the mouse from the right to the left side of the window. To undo this selection you have to move the mouse under simultaneous pressing of the left button from the left to the right side of the window. Rev. 150728001 12

BlueSens gas sensor GmbH Snirgelskamp 25 45699 Herten Germany Tel. +492366 / 4995-500 Fax +492366 / 4995-599 www.bluesens.de Rev. 150728001 13