RTA Series 1 4 Poles Coded Rotary Switches

Similar documents
RTA Series 1 4 Poles Coded Rotary Switches

Introduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots

Technical information for hinges

Prewired position switches FA series

Position switches FP series

D-Sub Vertical Surface Mount Connectors RoHS compliant Economical Interface Solution for SMT Applications

General Specifications

Model range*1) Switching pressure difference

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

Prewired position switches FA series

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors

Tapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.

Quick Reference Guide Power Series Switches

CFSW. Hinges with built-in safety multiple switch

Datamate Specification. Pin Numbering. Mating Profiles. Materials. Mechanical. 3 Row 6.

Pneumatic pressure switch 20DD

Amphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications

SOLENOID VALVES AND PNEUMATIC VALVES

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

[Instruments for vacuum measurement, checking and adjustment] 3

G SERIES METRIC MACHINE SCREW ACTUATOR

CFSW. Hinges with built-in safety multiple switch

Industrial Products Catalog Tank Valves

5. STRUCTURAL ANALYSIS

Glenair Well-Master TM 260 Micro-D Withstands Extreme High Temperature

E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA or E3FB

SEALED CONNECTORS FOR THE LIMIT SWITCHES

SENSORS Pressure CALDARO

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Reservoir End Covers Type EC

02 Push-to-Close Latch

Low Wind High Yields Series

PVQ 13 A2 R SE 1 S 20 C-11 D

I.H.S INSTALLATION INSTRUCTIONS

SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC.

Hand lever valves VHER

Inverse Proportional Pressure-Relief Cart., Size 2 4

Channel Bracket Support Cable Bracket Bearer Locking Pin Foundation Bolt Iron Anchor Step Manhole Sump Grill PVC/Steel Ladder Ladder Support & Hook

Digital Flow Switch. Series PFM7

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

Proportional Pressure-Relief Cartridge Valve, Size 2...4

RoHS. WS Series Snap Action Switch. Specifications. Part Number Configurator

CALEFFI. Ball zone valves. series /03 GB

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

BUL: 3-way unit valve, PN 16

GS - Parallel Gripper

RECTANGULAR CONNECTORS

Standard Hangers and Adapters

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

Proportional pressure regulators VPPE

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Gripping rotary modules

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

MPRM1690 MPRM2590 MPRM3290


Parts Manual. Scraper Hitches PH:

HEAVY DUTY PNEUMATIC

INSTRUCTION MANUAL Pressure Relief Device LPT

*NOTE: 75 OHM SERIES CONNECTORS ARE NOT INTERMATEABLE WITH THE 50 OHM SERIES.

Eurostyle Terminal Blocks Focus Product Stock List

Solenoid valves VZWF, force pilot operated

Ceramic Disc Capacitors Safety Standard Approved Disc Capacitor

DSL, DSH: Specially designed pressure limiter

Actuator Material. Style BCP. Bat BCP BCP BCP BCP BCP BCP BCP BCP BCP. Bat Bat Bat Bat Bat Bat Bat Bat Bat. Actuator Style

IP65 Air Differential Pressure Switch

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

FULL HEX RIVET NUT INSERT

Coding of banjo flow controllers. Actuation M = Manual S = Screwdriver

B2KL: 6-way ball valve with male thread, PN 16

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

Type 4708 Supply Pressure Regulator

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

Reliability and flexibility in a compact design

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Compact pressure switches for gas and air

Pressure Transmitters 36 F-27839

TENSOREX C+ TENSOREX C+

Power Inductors Type 3621 Series Type 3621 Series Electrical Characteristics A Series S.R.F. R.D.C. Irms (A) Isat(A) Inductance Inductance

Actuator Material. Style BCP. Bat BCP BCP BCP BCP BCP BCP BCP BCP BCP. Bat Bat Bat Bat Bat Bat Bat Bat Bat. Actuator Style

A comprehensive approach to monitor weight of fire extinguishing agent

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

TECHNICAL INFORMATION

Diaphragm pressure switches, 42 V

SpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Infrared Linescanners

Flow control valves Series RFU - RFO 2/

3/8" Safety Cable Systems

Troyer s Gourd Rack 8 unit F R H O P

Miniature controls. Contactors. Overload relays. Starters. Control relays

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

MANUAL KPS Pressure Control Valve

Pilot Check Valve: Metal Body Type

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Transcription:

1 4 Poles oded Switches Features/Benefits PB or hand soldering versions Bushing mounting Multiple poles Decimal and hexadecimal codes Screwdriver slot or extended actuator RoHS ompliant Typical Applications Appliances Electronic alarm systems Medical Building automation HVA air conditioning Electrical Data Silver Gold SWITHING MODE: BBM BBM MAX. SWITHING POWER 5 VA 0.5 VA MAX. SWITHING URRENT: 150 ma 20 ma MAX. ARRYING URRENT: 5 A 1 A NOMINAL VOLTAGE AT 50 Hz 60 V 25 V ONTAT RESISTANE: < 150 mω < 150 mω DIELETRI STRENGTH AT 50 Hz BETWEEN ONTATS AND GROUND TERMINALS: 500 V r 500 V r INSULATION RESISTANE BETWEEN ONTATS OR ONTATS AND FRAME (500 V =): 10 9 Ω 10 9 Ω OF OPERATIONS: 10,000 10,000 BOUNE: < 5 ms < 5 ms Environmental Data OPERATING TEMPERATURE: 20º to + 70º 20º to + 70º STORAGE TEMPERATURE: 40º to + 85º 40º to + 85º NOTE: Specifications and materials listed above are for switches with standard options. For information on specific and custom switches, consult ustomer Service enter. Mechanical Data MAX. OF BANS: 1. OPERATING TORQUE: 5 Ncm±20%. END STOP TORQUE: < 60 Ncm. STOP: With/without or adjustable MOUNTING: By fixed index 9.5 mm (0.374) of center, for bushing mount only Materials BUSHING/HOUSING: PETP Thermoplastic STATIONARY ONTATS & TERMINALS: Nickel Plated Brass with additional plating of Gold or Silver. ROTOR: Gold or Silver plated Brass or PB. ODING PLATE: PA thermoplastic ATUATOR: Polysulfon thermoplastic HARDWARE: Stop pin: Aluminum. Ball & Spring: Stainless steel. Washer: PA. Nut: Brass. Build-A-Switch To order, simply select desired option from each category and place in the appropriate box. Available options are shown and described on pages -9 thru -12. For additional options not shown in catalog, consult ustomer Service enter. Designation RTA Termination P With P Thru-hole H Horizontal with Switch Function P Thru-hole 1W12 SP, 30 Index, 12 pos. no stop 1W10 SP, 36 Index, 10 pos. no stop 1S02 SP, 30 /36 Index, 2 pos. 1S03 SP, 30 /36 Index, 3 pos. 1S04 SP, 30 /36 Index, 4 pos. 1S05 SP, 30 /36 Index, 5 pos. 1S06 SP, 30 /36 Index, 6 pos. 1S07 SP, 30 /36 Index, 7 pos. 1S08 SP, 30 /36 Index, 8 pos. 1S09 SP, 30 /36 Index, 9 pos. 1S10 SP, 30 /36 Index, 10 pos. 1S11 SP, 30 Index, 11 pos. 1S12 SP, 30 Index, 12 pos. 2S02 DP, 30 /36 Index, 2 pos. 2S03 DP, 30 /36 Index, 3 pos. 2S04 DP, 30 /36 Index, 4 pos. 2S05 DP, 30 /36 Index, 5 pos. 2S06 DP, 30 Index, 6 pos. 3S02 3P, 30 /36 Index, 2 pos. Indexing 2 22.5 index (coded only) 3 30 index (12 positions max.) 4 36 index (10 positions max.) 3S03 3P, 30 /36 Index, 3 pos. 4S02 4P, 30 /36 Index, 2 pos. EW10 Direct + complement, 36º Index, no stop EW12 Direct + complement, Index, no stop DW16 Direct, 22.5º Index, no stop ES Direct + complement, Index, with stop (specify stop position) DS Direct, 22.5º Index, with stop (specify stop position) Mounting Style W Without bushing R 3/8-32 Threaded Bushing M M10x.75 Metric Threaded Bushing A 3/8-32 Threaded Bushing with Offset Bracket B M10x.75 Metric Threaded Bushing with Offset Bracket 8 D ontact Material S Silver plated, matte-tin terminal P Gold plated, matte-tin terminal Actuator (max.) 25N.984 (25,0) with screwdriver slot 50N 1.97 (50,0) with screwdriver slot FLS Flush shaft with screwdriver slot and position indicator 25F.984 (25,0) Shaft with flat 06F.236 (6,0) Shaft with flat 3/8-32 Threaded Bushing with Straight Bracket M10x.75 Metric Threaded Bushing with Straight Bracket

1-4 Poles oded Switches DESIGNATION RTA TERMINATION P WITH P PINS.016 (0,4).028 TYP. (0,7) 1.016 (25,8) 0 (25,4) 0 (15,2).866 (22,0).150 (3,8).100 TYP. (2,5) H Horizontal with P Thru-hole Note: H termination only available with the following options: 1. With A or B mounting styles 2. 36º degree indexing 3. Up to 5 positions max 7X.028 ( 0,7 ) 0 0 ( 2,54 ) 2 ( 7,67 ) ING 2 22.5 index, 16 positions max. 3 30 index, 12 positions max. 4 36 index, 10 positions max. Both commons must be connected by user to ground. 9

1-4 Poles oded Switches SWITH FUNTION POLES 1W12 1W10 SWITH FUNTION 12 Positions 10 Positions 36º SP S SHEMATI 0 3P S SHEMATI 1 2 3 POLES 2W05 2W06 SWITH FUNTION 1S02 2 Positions Pos. Pos. 1 1 2 1 3 1 1 2 2 2 3 2 1 3 2 3 3 3 2S02 2 Positions SP 1S03 1S05 1S06 DP S SHEMATI 1 2 4P S SHEMATI 1 2 3 4 DP 2S03 2S04 2S05 4 Positions 1S08 8 Positions 2S06 1S09 1S10 1S11 1S12 9 Positions 10 Positions 11 Positions 12 Positions Pos. 1 1 2 1 3 1 4 1 5 1 6 1 1 2 2 2 3 2 4 2 5 2 6 2 EW10 EW12 DW16 Pos. 1 1 2 1 1 2 2 2 1 3 2 3 1 4 2 4 SWITH FUNTION Direct + complement, No stop Direct + complement, No stop Direct, No stop 36º 22.5º 3P 4P 3S02 3S03 4S02 2 Positions 2 Positions ES Direct + complement, with stop (specify stop position) & 36º DS Direct, with stop (specify stop position) 22.5º 22.5º 36º Term. Term. Term. Pos. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 E,J M,N L,N F, D D, D B A,N A I B J J H B A I Indexing Option ode 2, 22.5 ING ANGLE PB LAYOUT 1 2 4 8 1 2 4 8 Indexing Option ode 3, 30 ING ANGLE PB LAYOUT BD ONLY 1 POLE 2 POLES 3 POLES 4 POLES BD + OMPLEMENTS Indexing Option ode 4, 36 ING ANGLE PB LAYOUT NOTE: Layout view from component side. ommon terminals that are in locations A-G are not connected to common terminals that are in locations H-N. For 7-12 position output customer must tie these commons together. 1 POLE 2 POLES 3 POLES 4 POLES BD + OMPLEMENTS 10

1-4 Poles oded Switches MOUNTING STYLE W WITHOUT BUSHING M M10 x.75 MERTI THREADED BUSHING N M L J.495 (12,6).732 (18,6) M10 METRI N M L J.402 DIA. (10,2ø).374 (9,5).134 DIA. (3,4ø) Note: W mounting style not available with H termination. Note: M mounting style not available with H termination. R 3/8-32 THREADED BUSHING.134 (3.4Ø) A 3/8-32 THREADED BUSHING WITH BRAET.338 ( 8,59) ( 22,2) N M L J.374 (9.5) 3/8-32 UNEF.338 ( 8,59 ) ( 22,2 ) 7X ø.04.19 ( 2,1 ) ( 1,8 ) 0 ( 15,2) ( 15,7) ( 0,8 ).188 Note: R mounting style not available with H termination. Note: A mounting style only available with H termination. B 7X ø.04 M10 x.75 METRI THREADED BUSHING WITH BRAET.19 ( 2,1 ) (1,8) Note: B mounting style only available with H termination. 0 (15,24) (15,7) (0,8).188 (4,77).735 (18,67) 3/8-32 THREADED BUSHING WITH STRAIGHT BRAET.32 ( 8,1 ) 7X ø.04 ( 1,8 ) ( 2 ) 0 ( 0,8 ) ( 22,2 ).318 ( 8,07 ) D M10 x.75 METRI THREADED BUSHING WITH STRAIGHT BRAET.32 ( 8,1 ) 7X ø.04 ( 2 ) ( 1,8 ) 0,8 () 0.735 ( 18,67 ).318 ( 8,07 ) 11

1-4 Poles oded Switches ATUATOR 25N.984 (25,0) WITH SREWDRIVER SLOT 50N 1.97 (50,0) WITH SREWDRIVER SLOT.177 ( 4,5 ) ( 1 ) Ø.236 6 ( ).177 ( 4,5) ( 1) Ø.236 6 ( ).984 ( 25 ) 1.969 ( 50 ) FLS FLUSH SHAFT WITH SREWDRIVER SLOT AND POSITION INDIATOR 25F.984 (25,0) SHAFT WITH FLAT.220 DIA. (5,6Ø).091 (2,3).984 (25,0).945 (24,0) (1,0).157 (4,0) 30 06F.236 (6,0) SHAFT WITH FLAT.197 ( 5,0 ).157 ( 4,0 ).236 ( 6,0 ) ONTAT MATERIAL OPTION ONTAT AND ODE TERMINAL MATERIAL RATING S SILVER LOW LEVEL/DRY IRUIT SWITH: 150 ma MAXIMUM, 60 V NOMINAL. POWER: 5 VA MAXIMUM. ARRY-5 AMPS MAXIMUM. P GOLD LOW LEVEL/DRY IRUIT OR POWER SWITH: 20 ma MAXIMUM, 25 V NOMINAL. POWER: 0.5 VA MAXIMUM. ARRY: 1 AMP MAXIMUM. * Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications. AVAILABLE HARDWARE Mounting Nuts Stop pins Lockwasher PART 472706201 Standard PART 495100201 Metric PART Y200300200PH PART 472800202 NOTE: Additional nuts and lockwashers available separately, see section Technical Data and Additional Hardware. 12