Fisher 4194 Differential Pressure Indicating Controllers

Similar documents
4194 Series Differential Pressure Indicating Controllers

Fisher 4194H Differential Pressure Indicating Controllers

Fisher 4195K Gauge Pressure Indicating Controllers

Fisher L2sj Low Emission Liquid Level Controller

Fisher 4660 High-Low Pressure Pilot

Fisher 4660 High-Low Pressure Pilot

Type 4660 High-Low Pressure Pilot

Model 4000 Pressure Controller

Fisher C1 Pneumatic Controllers and Transmitters

Fisher C1 Pneumatic Controllers and Transmitters

Fisher 2625 and 2625NS Volume Boosters

4150K and 4160K Series Wizard II Pressure Controllers and Transmitters

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

C1 Series Pneumatic Controllers and Transmitters

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Type R622 Pressure Reducing Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

1805 Series Relief Valves

Type EZH Relief or Backpressure Regulator

Fisher C1 Pneumatic Controllers and Transmitters

PRO-50 Instrument Supply Regulator

T208VR Series Tank Blanketing Vacuum Regulator

Fisher DVI Desuperheater Venturi Inline

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Fisher DSA Steam-Atomized Desuperheater

1805 Series Relief Valves

Model 130M Pneumatic Controller

670 Series Panel-Mounted Loading Regulators

Design DSA Steam-Atomized Desuperheater

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Fisher and Whisper Disk Diffusers

Type Cronos Pressure Reducing Regulator

64 Series Pressure Reducing Regulators

OPERATING AND MAINTENANCE MANUAL

S300 Series. Valve Link. Features. Fisher Controls

Powers Controls RC 195 Single Input Receiver-Controller

1305 Series Pressure Reducing Regulators

Fisher 8532 High-Performance Butterfly Valve

Y692VB Series Vacuum Breaker

RC 195 Receiver-Controller

Powers Controls RC 195 Multiple Input Receiver- Controller

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Fisher FIELDVUE DVC6200f Digital Valve Controller PST Calibration and Testing using ValveLink Software

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Type 299 Pressure Reducing Regulators

Types S100K and S102K Pressure Regulators

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

RESIDENTIAL REGULATORS

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

Types 627W and 627WH Direct-Operated Pressure Reducing Liquid Regulators

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

Float Operated Level Controllers

The Ins and Outs of I/P Transducers

Electropneumatic Transducer (I/P) Installation, Operation and

Model Series 62 Constant Differential Relay

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

1200 Series Pressure Regulators

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

Safety manual for Fisher GX Control Valve and Actuator

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

1301 Series High-Pressure Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Type 4708 Supply Pressure Regulator

Air Operated Hydraulic Pumping Systems to 50,000 psi

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Type 99 Pressure Reducing Regulators

TECHNICAL DATA. Q = C v P S

66 Series Direct-Operated Regulators and Vacuum Service Equipment

TECHNICAL DATA. Q= Cv S

971 Series Pressure Reducing Regulators

Types 95L and 95H Pressure Regulators

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

9700 Transmitter Submersible hydrostatic level transmitter

Type 4660 High-Low Pressure Pilot

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

TECHNICAL DATA. Page 1 of 12

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

ACTUATORS AND INSTRUMENTS

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Fisher 4660 High Low Pressure Pilot

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Type 1190 Low-Pressure Gas Blanketing Regulator

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Autocalibration Systems for In Situ Oxygen Analyzers

VACUUM REGULATORS CONTENTS

Choosing the right miniature instrument and control valve is a snap

Masoneilan* 78 Model Air Filter Regulator

HORIZONTAL BLADDER TANK

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Liquid Level Controllers

MEGR-1627 Instruction Manual

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Transcription:

4194 Differential Pressure Controllers D200048012 Product Bulletin Fisher 4194 Differential Pressure Indicating Controllers Fisher 4194 (low pressure) differential pressure indicating controllers show process differential pressure and set point on an easy to read process scale. The controllers sense two different pressures and compare the difference between these pressures with an operator adjusted set point. A pneumatic signal is then delivered to a control element to change the process differential pressure toward the set point. The controllers use a capsular element for differential pressure up to 2.0 bar (30 psi). They are available for proportional only, proportional plus reset, and differential gap control. The controller is also available (see table 1) with anti reset windup, internal auto/manual station, and remote set point adjustability (see table 1). 4194 controllers are used in industry where process monitoring and accurate measurement of differential pressures are required. SET POINT ADJUSTMENT PROCESS INDICAR W5850 1 W5827 2 CONTROLLER YOKE MOUNTED ON ACTUAR OF CONTROL VALVE SUPPLY GAUGE OUTPUT GAUGE INTERIOR OF CONTROLLER www.fisher.com

Product Bulletin 4194 Differential Pressure Controllers D200048012 Specifications Available Configurations See table 1 Sensing Element Range (Input Signal) See table 2 Process Scale Linear, square root, or others on request (1) Process Connections Standard: 1/4 NPT internal stainless steel (all input ranges) Optional: 1/2 NPT external stainless steel Output Signal Proportional or Proportional Plus Reset Range: 0.2 to 1.0 bar (3 to 15 psig) or 0.4 to 2.0 bar (6 to 30 psig) Differential Gap Output: 0 and 1.4 bar (0 and 20 psig) or 0 and 2.4 bar (0 and 35 psig) Action: Field reversible between direct (increasing sensed pressure increases output pressure) or reverse (increasing sensed pressure decreases output pressure) Supply and Output Connections 1/4 NPT internal Controller Adjustments Proportional Band: 5 to 500% of process scale range Reset: Adjustable from 0.01 to more than 74 min per repeat (from 100 to less than 0.0135 repeats per min) Differential Gap Controllers: Adjustable from 1 to 100% of process scale range Set Point: Continuously adjustable from 0 to 100% of the scale range. Internal Set Point Adjustment (standard): Internal adjustment knob Controller Performance (3) Repeatability: 0.09% of process scale range Dead Band: Less than 0.2% of process scale range Typical Frequency Response: 1.5 Hz and 90 deg phase shift with 3.05 m (10 feet) of 6.44 mm (1/4 inch) tubing and 1639 cm 3 (100 in. 3 ) volume Steady State Air Consumption (3)(4) 0.2 to 1.0 Bar (3 to 15 psig) Output: 0.08 m 3 /hr (2.8 scfh) 0.4 to 2.0 Bar (6 to 30 psig) Output: 0.07 m 3 /hr (2.5 scfh) Operative Ambient Temperature Limits (2)(5) 40 to 70 C ( 40 to 160 F) Hazardous Area Classification Complies with the requirements of ATE Group II Category 2 Gas and Dust Supply Pressure Requirements (2) See table 3 Supply Pressure Medium Air or non-corrosive Natural Gas Remote Set Point Pressures 0.2 to 1.0 bar (3 to 15 psig) or 0.4 to 2.0 bar (6 to 30 psig) Construction Materials See table 4 Meets Customs Union technical regulation TP TC 012/2011 for Groups II/III Category 2 equipment II Gb c T* III Db c T* Mounting Controller can be mounted on actuator, panel, wall, or pipestand Approximate Weight 4.5 kg (10 lb) NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology. 1. Consult your Emerson sales office or Local Business Partner for additional information. 2. The pressure/temperature limits in this document, and any applicable code or standard should not be exceeded. 3. Normal m 3 /hr normal cubic meters per hour (m 3 /hr, 0 C and 1.01325 bar, absolute). Scfh standard cubic feet per hour (ft 3 /hr, at 60 F and 14.7 psig). 4. Without auto/manual switch. With auto/manual switch add 0.01 normal m 3 /hr (0.5 scfh). 5. Also for transportation and storage limits. 2

4194 Differential Pressure Controllers D200048012 Product Bulletin Table 1. Available Configurations TYPE NUMBER (1) 4194A 4194AE 4194AM 4194AME 4194B 4194BE 4194BF 4194BFE 4194BM 4194BME 4194BFM 4194BFME 4194C 4194CE 4194CF 4194CFE 4194CM 4194CME 4194CFM 4194CFME 4194S 4194SE 4914HSM 4194SME Proportional Only Proportional Plus Reset Proportional Plus Reset Plus Rate (2) CONFIGURATIONS Differential Gap Anti Reset Windup Remote Set Point Internal Auto/ Manual Station 1. Reverse acting constructions are designated by an R added to the type number. 2. Consult your Emerson sales office or Local Business Partner for information on rate. Features Easy Maintenance Simple design of the controller allows fast, easy maintenance and minimal spare parts inventory. Easy Adjustment Adjusting the set point and the zero and span of the process pointer and switching between direct and reverse action are accomplished quickly and without special tools. Also, the set point and proportional band can be adjusted with no interaction between the two adjustments. Vibration Resistant Simple design and low mass of internal parts allow the controller to withstand vibration encountered in most plant environments. Low Air/Gas Consumption The relay and nozzle design reduces the steady-state consumption rate to as low as 0.07 m 3 /hr (2.5 scfh); less than the 6 scfh requirement set for the oil and gas industry by the US Environmental Protection Agency (New Source Performance Standards Subpart OOOO, EPA HQ QAR 2010-0505). Corrosion Resistant Tough plastic housing resists corrosive environments. Internal constructions are available to resist a corrosive supply pressure media. Mounting Versatility The controller can mount directly on the actuator or it can mount on a pipestand, on a wall, or in a panel. Highly Visible Display Two red pointers on a 114 mm (4 1/2 inch) long white on black scale show differential pressure and deviation from set point at a glance. Two other gauges monitor supply and output pressures. 3

Product Bulletin 4194 Differential Pressure Controllers D200048012 Table 2. Process Sensor (Capsular Element) Ranges, and Pressure Ratings AVAILABLE CAPSULAR ELEMENT RANGES MINIMUM (1) DIFFERENTIAL SPAN MAIMUM ALLOWABLE (2) DIFFERENTIAL Bar Psid Bar Psid Bar Psid Bar STATIC OPERATING RANGE MAIMUM ALLOWABLE (3) STATIC Minimum Maximum Inches of Bar Psig Bar Psig Mercury 0 to 0.4 0 to 5 0.2 2.5 0.4 5-0.4-10 0.4 5 0.5 7.5 0 to 0.7 0 to 10 0.4 5.0 0.7 10-0.7-20 0.7 10 1.0 15.0 0 to 1.4 0 to 20 0.7 10.0 1.4 20-1.0-30 1.4 20 2.1 30.0 0 to 2.0 0 to 30 1.0 15.0 2.0 30-1.0-30 2.0 30 3.1 45.0 1. Span is adjustable between minimum shown and maximum of the capsular element operating range and can be positioned anywhere within this range. For example, if a (0 to 2.0 bar (0 to 30 psid) capsular element is used and the minimum span of 1.0 bar (15 psid) is set, the process indication can be calibrated to a range of 0 to 1.0 bar (0 to 15 psid), 1.0 to 2.0 bar (15 to 30 psid), or any value between the minimum and maximum values of the operating range. 2. Maximum difference between the two input supply pressures. 3. Capsular element may be pressured to this valve (after reaching travel stop at upper range limit) without permanent zero shift of structural damage to controller components. Table 3. Supply Pressure Data Bar Psig Output Signal Range 1. If this pressure is exceeded, control stability may be impaired. 2. If this pressure is exceeded, damage to the controller may result. Normal Operating Supply Pressure (1) Maximum Pressure to Prevent Internal Damage (2) 0.2 to 1.0 or 0 and 1.4 (differential gap) 1.4 3.4 0.4 to 2.0 or 0 and 2.4 (differential gap) 2.4 3.4 3 to 15 or 0 and 20 (differential gap) 20 50 6 to 30 or 0 and 35 (differential gap) 35 50 Table 4. Construction Materials Part Standard Material Optional Material Case and cover Polyester plastic --- Exterior tubing Copper Aluminum, stainless steel, steel, or polyethylene Exterior fittings C36000 (brass) Aluminum, stainless steel, steel, or polyethylene Interior tubing S30400 (304 stainless steel) --- Capsular element N09902 (Nickel alloy) --- Nozzle S30300 (303 stainless steel) --- Flapper S31600 (316 stainless steel) --- Relay springs S30200 (302 stainless steel) or steel --- Relay O rings Nitrile --- Relay diaphragms Nitrile --- Other relay metal parts Aluminum or stainless steel --- Feedback bellows assembly C51000 (bronze) S32100 (321 stainless steel) Supply and output gauges Brass (wetted parts only) Stainless steel (wetted parts only) Remote set point bellows N09902 --- 4

4194 Differential Pressure Controllers D200048012 Product Bulletin Figure 1. Operational Schematic of Fisher 4194 Differential Pressure Controllers MANUAL SET POINT ADJUSTMENT PROCESS POINTER PROPORTIONAL RESET (VENTED) PROPORTIONAL BAND ADJUSTMENT FEEDBACK LINK REVERSE ACTION QUADRANT REMOTE SET POINT CONNECTED HERE INPUT ELEMENT CONNECTED HERE CONNECTING LINK FEEDBACK MOTION DIRECT ACTION QUADRANT INPUT MOTION FLAPPER DETAIL FLAPPER PIVOT BEAM FLAPPER OUTPUT CONTROL DEVICE SUPPLY NOZZLE OUTPUT PROPORTIONAL NOZZLE RESET PROPORTIONAL ONLY CONTROL SUPPLY RELAY PROPORTIONAL RESET NOZZLE OUTPUT PROPORTIONAL RESET NOZZLE NOZZLE RESET OUTPUT OUTPUT RESET VALVE SUPPLY RELAY RESET VALVE RELIEF VALVE SUPPLY RELAY SUPPLY RELAY PROPORTIONAL PLUS RESET CONTROL C0742 PROPORTIONAL PLUS RESET CONTROL WITH ANTI RESET WINDUP DIFFERENTIAL GAP CONTROL Principle of Operation Refer to figure 1 (proportional only control). The input element is connected to the process pointer and flapper by a connecting linkage. As the process differential pressure increases (in a direct acting controller), the flapper moves toward the nozzle, restricting flow through the nozzle and increasing nozzle pressure. When this occurs, relay action increases the output pressure (delivery) of the controller. Output pressure is fed back to the proportional bellows. The action of the proportional bellows counters the flapper movement that resulted from the process differential pressure change, and backs the flapper away from the nozzle. Set point adjustment also changes the proximity of the nozzle and flapper; however, when the set point is changed, the nozzle moves with respect to the flapper. When the controller is in the reverse acting mode (see flapper detail in figure 1), an increase in process differential pressure causes a decrease in output pressure. 5

Product Bulletin 4194 Differential Pressure Controllers D200048012 Figure 2. Controller Construction Detail SET POINT ADJUSTMENT INPUT ELEMENT (CAPSULAR ELEMENT) PROPORTIONAL BAND COVER PROPORTIONAL BAND ADJUSTMENT 1 ZERO ADJUSTMENT 2 SPAN ADJUSTMENT 2 CONNECTING LINK Notes: 1 White portion of adjustment enables direct controller action; black portion enables reverse controller action. 2 For the process pointer. W3612 1 In addition to the proportional only (4194A) version, a controller is available for proportional plus reset control (4194B). In this controller, output pressure is fed back to the reset bellows as well as to the proportional bellows. Anti reset windup is available on all controllers with reset. Remote set point is available on all controllers. The 4194S controller provides differential gap control. In this version, feedback pressure is piped directly to the reset bellows, reinforcing the change in flapper position rather than counteracting it. This construction causes the controller output to switch from full supply pressure to zero pressure or vice versa. The schematic diagram (figure 1) emphasizes detail of construction variations between control modes. Refer to table 1 for a complete description of type number suffixes. Construction Features Simplified Relay Maintenance A clean out wire provides a fast, easy means of cleaning the relay primary orifice during service. Pressure Protection for the Case A rubber plug in the plastic case pops out to prevent excessive pressure buildup from occurring inside the case before structural damage can take place. Easy Direct/Reverse Switching Controller action can be switched from direct to reverse or vice versa by simply loosening the screws on the proportional band cover and moving the cover out to rotate the proportional band knob to the desired action (see figure 2). 6

4194 Differential Pressure Controllers D200048012 Product Bulletin Figure 3. Typical Yoke Mounting Figure 4. Controller Dimensions 657 ACTUAR 4194 CONTROLLER REMOTE SET POINT CONNECTION P VIEW 260 (10.25) 130 (5.13) 102 (4.00) 51 (2.00) 5/16-18 UNC 2B 3 HOLES (MOUNTING) 67FR FILTER REGULAR 330 (13.00) 87 (3.44) 255 (10.04) MOUNTING PLATE FRONT VIEW REAR VIEW W5661 Easy Mode Conversion Conversion from proportional to proportional plus reset control requires the addition of a reset valve and two pieces of tubing. Conversion from proportional to differential gap control requires the addition of one piece of tubing. HIGH LOW 46A9765 A A5710 1 BOTM VIEW 147 (5.80) 66 (2.56) 31 (1.22) 1/4 NPT 4 HOLES mm (INCH) Anti Reset Windup Anti reset windup is available with proportional plus reset controllers. Relief valve may be installed to limit reset windup in either direction. Remote Set Point The capability of adjusting the set point from a remote location is available as an option on 4194 controllers. Auto/Manual Capability An internal auto/manual station is available for smooth bumpless transfer from automatic to manual and manual to automatic control of the controller output. Installation The 4194 differential pressure controllers may be shipped alone for a separate installation or for installation on a control valve actuator. The controllers can also be mounted on a pipe stand, on a wall, or in a panel. When a controller is mounted on an actuator and a positioner is not used, the controller will usually be opposite the supply regulator as shown in figure 3. If a positioner is used, the supply regulator can be mounted on the actuator casing. The controller must be installed so that the vent opening faces down. Basic controller dimensions are shown in figure 4. Dimensions for specific mounting methods are shown in figure 5. 7

Product Bulletin 4194 Differential Pressure Controllers D200048012 Figure 5. Mounting Dimensions 92 (3.62) 84 (3.29) 63 (2.49) 161 (6.35) HORIZONTAL PIPE 95 P VIEW P VIEW (3.75) 222 (8.75) 62 (2.43) 13 (0.50) 260 (10.25) 62 (2.43) 13 306 (0.50) (12.06) 152 (6.00) 36A9757 A B1473 4 36A9759 A 14R (0.56R) 236 (9.31) SIDE VIEW VERTICAL PIPE REAR VIEW DIMENSIONS OF PANEL CUUT REAR VIEW PIPESTAND MOUNTING PANEL MOUNTING WALL MOUNTING mm (INCH) 36A9761 B 13 (0.50) 62 (2.43) Ordering Information When ordering, specify: Application 1. Description of the service, such as throttling or on off 2. Pressure range, composition, and temperature of process fluid 3. Ambient temperature Construction Refer to the specifications and the Construction Features section. Carefully review each specification and feature, indicating your choice whenever a selection is to be made. Refer to table 1 for type numbers; add R to any type number if reverse action is desired. Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Automation Solutions Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Cernay 68700 France Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com 8 1991, 2017 Fisher Controls International LLC. All rights reserved.