Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Similar documents
6 digital caliper with case

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

700 SERIES BMS II BUBBLER MONITORING SYSTEM

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

92831 TEL: (714) FAX:

92831 TEL: (714) FAX:

Model ASSEMBLY and OPERATING INSTRUCTIONS

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

R E D I C O N T R O L S

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

4 and 8 Station PDS Control Installation & Operators Manual

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

J Air and Water Kit Instructions Part# 02584

AIR INLINE METAL SHEAR

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

TrekMill USER'S MANUAL MM5050

In Vivo Scientific, LLC INSTRUCTION MANUAL

Model No Product Name Handpiece Only Complete System

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

D Series Air and Water Kit Part# 02550

DEEPSEA. SeaLite Lumos POWER & LIGHT. Operator s Manual Ruffin Road San Diego, CA USA.

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

2 Gallon, 100 PSI Oilless

Installation Instructions Air Compressor Part # 2780, 2781

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

210 Series Transmitter with External Electrochemical Sensor

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

8675/8677/8678 OWNER S MANUAL

MODEL 100 NITROGEN INFLATION CART

RAM 4021 Operation Manual

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

Portable oxygen concentrator

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Installation and Operation Manual

A3 / A4 / A5 / A6 / A8 Spherical Ionization Chambers REF / / / / User Manual

User s Guide Temperature Sensor Converter TSC-599

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Owner s Manual & Safety Instructions

77-I0PN230 Rev. A. Model 1030 User Manual

SOTR Special Operations Tactical Respirator

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

Portable Compressed CO 2 Regulator

KJ4000 Operating Instructions & Parts Manual NSN

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

HAS2400 Hepa Air Scrubber

DRAG HARROW SAFETY & OPERATING INSTRUCTIONS. Original Language. Serial No. Order No.

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

- GAS REGULATOR - COMPACT STYLE

Installation Instructions JATCO Environmental Protection Tank Model J-7000

Installation & User Guide. English Version 1.0

Installation, Operation & Maintenance Manual

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

453 Series Steam Heated Vaporizing Regulator

Golf Performance Monitors. PureContact Operating Guide. Version of 9

1/2 Twin Hammer Composite. Air Impact Wrench ASSEMBLY AND OPERATING INSTRUCTIONS

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Wireless Belt Pack BP Conductor with Radio Transmit

! Warning, refer to accompanying documents.

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

HoverJack. Air Patient Lift. Equipment Manual. From HoverTech International. Issued: June 1,

10% OFF HHPROMO. Havahart Spray Away Animal Repellent Sprinkler Owner s Manual Model #5266. Caught a critter in the act?

2 Gallon Air Compressor

Wireless Belt Pack BP Conductor Jack with Radio Transmit & Volume Control

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

6 & 8 Bubble Panel Installation Manual

Owner s Manual Humiport 10/20

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

AA100 Acoustic Actuator

Model OPERATING INSTRUCTIONS. Due to continuing improvements, actual product may differ slightly from the product described herein.

Model 6202 Reduced Oxygen Breathing Device 2

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Installation, Operation & Maintenance Manual

This document to be used with Hurley traditional Davits

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

COMPACT METAL bender 99826

M3-LED. Operator s Manual. Operator s Manual MADE IN THE USA USA

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

RJE INTERNATIONAL, INC.

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Digital Vacuum Regulator

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

Aneroid Sphygmomanometer. Use, Care, & Maintenance

KJ1000 Operating Instructions & Parts Manual NSN

Fingertip Pulse Oximeter

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Transcription:

Vevazz Operation Manual Vevazz, LLC 30520 Rancho California Road Suite 107-46 Temecula, CA 92591 Phone: (773) 665-4005 Fax: (888) 234-2765 URL: www.vevazz.com

Warranty & Service Information Proprietary Notice Information contained in this document is copyrighted by Vevazz, LLC and may not be duplicated in full or part by any person without prior written approval of Vevazz, LLC. Its purpose is to provide the user with adequately detailed documentation to efficiently install, operate and maintain the device supplied. Efforts have been made to keep the information contained in this document current and accurate as of the date of publication or revision. Limited Warranty Vevazz, LLC warrants the Vevazz to be free from defects in workmanship and material under normal use for a period of one (1) year from the date of shipment. Vevazz, LLC's sole obligation under this warranty will be to repair or replace, at its option, the Vevazz that proves to be defective during the warranty period. The foregoing shall be the sole warranty remedy. Except as set forth herein, Vevazz, LLC makes no warranties, either expressed or implied, including the implied warranties of merchantability and fitness for a particular purpose. No warranty is provided if the Vevazz is modified without the express written consent of Vevazz, LLC. Vevazz, LLC shall not be liable in any event for incidental consequential damage. This warranty is not activated before the customer returns the completed Vevazz Product Registration form within 30 days after purchase of the product. This warranty is not assignable. Service Support In order to return your Vevazz under the terms of this one year limited warranty, you must contact us for a return merchandise authorization number (RMA number) within one (1) year from the shipping date. Call us at 773-665-4005 Monday through Friday 8:00am to 5:00pm MST to obtain the RMA number from our customer service department. The return of the Vevazz and all accompanying documents must be packed carefully to prevent shipping damage. The RMA number must be clearly printed on the outside of the shipping container.

Assembly instructions Unpack everything from the box Long Cords Short Cords Small Paddles and Cords Large Paddles Base Unit

Power Connector in Back of Base Unit Belts Tape Measure 1. Plug the power cord into the back

2. Plug the long 2 wires into the base unit where it says large paddle 3. Plug the short wire into one of the large paddles (either connector on the paddle) 4. Plug the other end of the short wire into another free paddle (either connector on the paddle) Optional connection for 2 paddle one long wire into each paddle and nothing more.

5. If you have 4 paddles - Repeat steps 3&4 with the other short wire and another different large paddle - you will have two sets of two paddles connected by a short wire. (either connector on the paddles) If you only have two paddles skip to step 8 6. If you have 6 paddles add one more paddle to each set of two paddles with a short wire for each paddle to make two sets of 3 paddles connected together 2 short wires (either connector on the paddles) if you only have 4 paddles skip to step 8

7. If you have 8 paddles Repeat steps 6 so you end up with two sets of 4 paddles connected by 3 short wires. If you only have 6 paddles skip to step 8 8. Plug the long wire into the paddle If you have more than two paddles, plug the long wire into one of the end paddles on one of the series of paddles 9. Plug the other long wire into the other paddle or series of paddles if you have more than 2 paddles

So you end up with two identical sets of paddle(s) connected to the base by one long wire 10. Plug the two smaller paddles into the ports where it says small paddle 11. Turn on the switch in the back of the unit you should see the red power indicator light - light up red

12. Push start, and all the paddles should light up for 7 minutes (along with the green running indicator light) And shut off automatically after 7 min.

Operating Instructions 1. Assemble the Vevazz Base Unit, Large Paddles and Small Lymphatic Paddles as illustrated in the Assembly Instructions. Plug in the number of Small Lymphatic Paddles to be used. Plug in the number of Large Paddles to be used. 2. Large Paddle Placement - Place each Large Paddle anywhere on the body below the neck, directly over the area needing to be treated. (See diagram below for areas of placement) Use the Velcro Patches as needed, to be put in place on the back of each Large Paddle using the adhesive, and the Vevazz Velcro Body Straps as needed in order to hold the Paddles in place. Large Paddle Placement: Place Large Paddles anywhere within the area marked RED 3. Small Lymphatic Paddle Placement - Each Small Lymphatic Paddle can be held in place by hand or placed under a waist band or other clothing. The Small Lymphatic Paddles are intended to be placed in the following areas (See diagram below for areas of placement): Below the diaphragm - in the inguinal lymph nodes Above the diaphragm - in the armpits Above the neck - in the subclavian lymph nodes Small Lymphatic Paddle Placement: Place the Small Lymphatic Paddles within the areas marked RED 4. Press the Start Button to initiate the LED light delivery treatment cycle. The treatment cycle will terminate once the 7 minute timer has elapsed. 5. How to Stop A Treatment Cycle: Pressing the Stop Button during the treatment cycle will stop the treatment and reset the machine back to the Initial Screen Display. To begin a new treatment cycle, press the Start Button once again.

Contraindications Below is a list of contraindications - situations in which the Vevazz SHOULD NOT be used to deliver an LED light delivery treatment cycle. Contraindications are conditions or factors that serve as a reason to withhold treatment because it may be harmful to the patient. If at any time there is a question as to whether a treatment should be administered using the Vevazz, always consult a medical doctor first. Not for use on: Open wounds or sores Minors People with a pacemaker People who have or are affected by photosensitivity People with epilepsy People with any form of cancer People with severe kidney problems People with severe liver problems People with thyroid problems Women who are pregnant or nursing Maintenance Cleaning and Disinfection Item: How Often: Procedure: Small Lymphatic Paddles After each use Using a soft cloth dampened with warm soapy water or isopropyl alcohol, wipe the entire face of the small lymphatic paddle, including the plastic window of the light-emitting surface. CAUTION: Do not allow liquid to enter any of the openings on the unit. Large Paddles After each use Using a soft cloth dampened with warm soapy water or isopropyl alcohol, wipe the entire face of the large paddle, including the plastic window of the light-emitting surface. CAUTION: Do not allow liquid to enter any of the openings on the unit. Preventative Inspection Before each use, carefully inspect the Vevazz Base Unit to make sure it does not appear damaged. Before operation the user should also check all Large Paddles and Small Lymphatic Paddles to verify that the protective cover housing the LEDs is intact. Vevazz, LLC has no serviceable or calibration requirements.

Specifications and Contact Information Power Requirements Power:120VAC@2A or 240VAC@1A Electrical output: 15 VDC @ 8.5 AMPS Model Specifications LED: Class 1 Non-Prescription Environmental Specifications Operating Temperature: 10-40⁰ C (50-104⁰ F) Storage Temperature: -30-55⁰ C (-22-131⁰ F) Relative Humidity: 10-95% (storage), non-condensing Storage Whenever possible, the Vevazz should be stored at room temperature in a cool, dry place. Storage Specifications are as follows: Temperature: -30⁰ C - 55⁰ C (-22⁰ - to 131⁰ F) Relative Humidity: 10% to 95% (non-condensing) 15% - 95% (operating), non-condensing

Contact Information In the United States or Canada Contact: Vevazz, LLC 30520 Rancho California Road Suite 107-46 Temecula, CA 92591 Tel: (773) 665-4005 Fax: (888) 234-2765 URL: www.vevazz.com