Interpreting the Status of an Underground Coal Mine Heating for Valid Risk Management and Control

Similar documents
Goaf Inertisation and Sealing Utilising Methane from In-Seam Gas Drainage System

The Role of Gas Monitoring in the Prevention and Treatment of Mine Fires

Challenges of gas monitoring and interpretation in underground coal mines following an emergency

Review of oxygen deficiency requirements for graham s ratio

COAL MINES TECHNICAL SERVICES, GAS DETECTION RELATED SERVICES FOR MINES RESCUE

T.I. Mayes and A.D.S Gillies. A Review of Current Australian Longwall Mine Ventilation Practice, Proceedings, First Mine Environment and Ventilation

Investigations into the identification and control of outburst risk in Australian underground coal mines

Applied Modelling of Ventilation and Gas Management to Increase Production in a Single Entry Longwall Panel

The Effect of Air Column in Transport Canisters on Measured Gas Contents

Investigation of spontaneous heating zones and proactive inertisation of longwall goaf in Fenguangshan Mine

Application of the QMRS GAG at Crinum North Mine

Problems with Determining Oxygen Deficiencies in Ratios Used for Assessing Spontaneous Combustion Activity

COAL AND GAS OUTBURST COMMITTEE. HALF DAY SEMINAR Wollongong 22 nd June, 2011

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

Gas Emission Modelling of Gate Road Development

! Time required for inertisation output to interact with and extinguish a fire.

T.I. Mayes and A.D.S Gillies. An Analysis of Current Australian Longwall Ventilation Methods, Proceedings, Seventh International Mine Ventilation

Describe Flammable Gas Measurement

CFD Modelling of Goaf Gas Migration to Improve the Control of Spontaneous Combustion in Longwalls

Proactive Strategies for Prevention and Control of Fires in Bord and Pillar Mines Working in Thick Coal Seams

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

OUTBURST THRESHOLD LIMITS ARE THEY APPROPRIATE?

Southern Districts Emergency Escape System

MINING INQUIRY BOX FLAT COLLIERY REPORT, FINDINGS AND RECOMMENDATIONS

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

Measurement of Representative Landfill Gas Migration Samples at Landfill Perimeters: A Case Study

Quantifying the impact of cover depth and panel width on longwall shield-strata interactions

Emerging Crash Trend Analysis. Mark Logan Department of Main Roads, Queensland. Patrick McShane Queensland Transport

Significant Change to Dairy Heat Treatment Equipment and Systems

Gas Content Measurement and its Relevance to Outbursting

2018 STATEMENTS OF FACT MINE RESCUE. 1. To test for methane, use a methane detector or chemical analysis.

Reduction of Speed Limit at Approaches to Railway Level Crossings in WA. Main Roads WA. Presenter - Brian Kidd

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Ultima. X Series Gas Monitor

Gas Content and Emissions from Coal Mining

Recognised Standard 08. Conduct of mine emergency exercises

INSTRUCTIONS FOR USING THE RISK ASSESSMENT FORM

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

STORM WATER RETENTION TANKS MAINTENANCE INFORMATION FOR HEALTH AND SAFETY FILE

Australian longwall panel ventilation practices

Chapter 7. Coal Cargoes. Properties and Characteristics 7.1

SPONTANEOUS COMBUSTION AT THE BLAIR ATHOL COAL MINE. S Prebble and A Self

Emergency management systems and plans

2018 National Metal and Nonmetal Mine Rescue Contest. Mine Rescue Field Competition Written Test. Good Luck!

Decreasing Post Blast Re-Entry Time with Battery-Powered Wireless Monitoring of Gas and Ground Movement

Gas Gathering System Modeling The Pipeline Pressure Loss Match

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

PSSI 36 General Confined Spaces, Tunnels, Culverts and Similar Spaces

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

CARRIAGE OF DIRECT REDUCED IRON (DRI) BY SEA CHANGES TO THE IMO CODE OF SAFE PRACTICE FOR SOLID BULK CARGO

Evaluation of the optimum conditions for a local ventilation system in connection with the mine ventilation network

EUSMUNC06 (SQA Unit Code - FG2W 04) Locate and avoid supply apparatus for Utilities Network Construction

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Confined Space Program

Hampstead Hill School Health and Safety Policy: Confined Spaces

Circular No. 3/ March To the members. Dear Sirs,

Dust Monitoring and Control Efficiency Measurement in Longwall Mining

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Retention Time Locking: Concepts and Applications. Application

Gun Vacuum Performance Measurements February 2003

2. Introduction of nitrogen injection displacement for fire extinguishment

Working in Gas Hazard Areas

A Revised Framework for the Transformer DGA Guide

A.M. Wala, A.D.S. Gillies and H.W. Wu, Lessons from an Underground Coal Mine Fire in Australia using Retrospective Numerical Simulation Study,

A GUIDE TO RISK ASSESSMENT IN SHIP OPERATIONS

QUARTERLY ACTIVITIES REPORT. Successful drilling of Primero West-1 well and Nyanda-4 corehole.

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Rapid and Reliable Detection of Dissolved Gases in Water

GEOTHERMAL WELL COMPLETION TESTS

Gas Accumulation Potential & Leak Detection when Converting to Gas

Simulation of the Effects of Inertisation of Fires on Mine Ventilation Systems

The purpose of this policy is to provide operational guidelines for San Diego County Fire Departments (FD) responses to natural gas incidents.

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

Hydraulic and Economic Analysis of Real Time Control

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

MODELLING OF FUME EXTRACTORS C. R.

Aberdeen Significant Error Review ITE Independent Report. Eur Ing Keith Vugler CEng FInstMC

On-Stream Tightness Testing of Vacuum Process Installations

Leveraging Gas Reservoir Data

PRAGMATIC ASSESSMENT OF EXPLOSION RISKS TO THE CONTROL ROOM BUILDING OF A VINYL CHLORIDE PLANT

SWMS No 009 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 4

NSW Mines Rescue Unmanned Aerial Vehicle (UAV)

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

2 nd International Mine Rescue Conference

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Key Technology, Inc. Confined Space Entry Program. July, 2017

Safe Work Practices / Procedures / Instruction CONFINED SPACE

Gas Tester Competent Person Course Outline

CONTRACTOR WHS HAZARD STANDARD CONFINED SPACE EXTERNAL USE ONLY

Pre Feasibility Study Report Citiwater Cleveland Bay Purification Plant

1. Add a new Annex B.8 to read as follows:

Challenges encountered by New Zealand mines rescue at the Pike River mine disaster

PERMIT-REQUIRED CONFINED SPACES PROGRAM

Transcription:

University of Wollongong Research Online Coal Operators' Conference Faculty of Engineering and Information Sciences 2016 Interpreting the Status of an Underground Coal Mine Heating for Valid Risk Management and Control Brendan Newham LDO Group Basil Beamish B3 Mining Services Pty Ltd Michael Brady Joncris Sentinel Services Matthew Fellowes Coal Services Publication Details Brendan Newham, Basil Beamish, Michael Brady and Matthew Fellowes, Interpreting the Status of an Underground Coal Mine Heating for Valid Risk Management and Control, in Naj Aziz and Bob Kininmonth (eds.), Proceedings of the 16th Coal Operators' Conference, Mining Engineering, University of Wollongong, 10-12 February 2016, 456-462. Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: research-pubs@uow.edu.au

INTERPRETING THE STATUS OF AN UNDERGROUND COAL MINE HEATING FOR VALID RISK MANAGEMENT AND CONTROL Brendan Newham 1, Basil Beamish 2, Michael Brady 3 Fellowes 4 and Matthew ABSTRACT: The status of an underground coal mine heating event is predominantly assessed based on gas sampling results from the affected area. The gas samples can be obtained in a number of different ways, but for accurate determination of the gases present analysis is normally performed using gas chromatography. Several gas indicators have been identified from past experiences that are used in combination to determine a Trigger Action Response Plan for individual mines. The upper levels of the Trigger Action Response Plan contain more urgent actions in response to the assessed level of advanced heating, with the ultimate level being withdrawal from the mine. Once this point is reached the only action that can be taken to control the event has to be done remotely and also, once activated it is difficult to re-enter the mine. Recent experience of a heating event provides new data that demonstrates the importance of understanding and interpreting the status of hot spot development to risk management and control applied by an Incident Management Team. This paper discusses the use of gas trending, including the development of: a new gas indicator ratio that is very sensitive to the heating status and control measures applied; and a hot spot tracking diagram that provides a good visual representation of the heating status and the response to actions taken. NTRODUCTION The identification of a spontaneous combustion event in an underground coal mine relies on vigilant use of a valid Trigger Action Response Plan (TARP) that has been designed to match the likely spontaneous combustion behaviour of the coal being mined. The TARP contains trigger levels based on a combination of physical (visual) signs and gas or gas ratio indicators that are chosen to enable appropriate early responses to be implemented to manage and control the event. At a more advanced stage of an event it may be necessary to prepare for sealing of the area to exclude air ingress, or in a more extreme case to completely inert the sealed area by injecting for example nitrogen. Once an event has been identified there is also the need for appropriate decision making to be implemented by an Incident Management Team (IMT) based on sound risk management supported with valid data interpretation of the status of the heating event. This decision making process is very important as the uppermost level of the TARP is withdrawal from the mine, which has consequences for both safety of mine personnel and the management options available once this point is reached. This paper presents a case study of a spontaneous combustion event that occurred in 2015, which was successfully managed and controlled by applying sound engineering principles. Key stages of the event are discussed in the paper rather than a blow by blow description of all the actions taken. As a result of the event some new lessons were learned that may assist in improving the management of future events. 1 LDO Group, 16 Spitfire Place, Rutherford NSW 2320, E-mail: BNewham@ldo.com.au, 0438401275, 2 B3 Mining Services Pty Ltd, PO Box 1565, Toowong BC QLD 4066,E-mail: basil@b3miningservices.com, 0488708949, 3 Joncris Sentinel Services, PO Box 736, Rockhampton QLD 4700,E-mail: michael@joncris.com.au, 0408064730, 4 Coal Services, 533 Lake Road, Argenton NSW 2284,E-mail: matthew.fellows@coalservices.com.au, 0429341853, 456 10 12 February 2016

BACKGROUND TO THE SPONTANEOUS COMBUSTION EVENT On Thursday 25th June 2015 a heating event was confirmed in 18 CT of the West Headings in the Great Northern Seam (GNS) at Mannering Colliery (Figure 1). This discovery resulted after a lengthy and difficult search initially triggered by a low level carbon monoxide alarm spike from the tube bundle monitor point at the GNS entry to the upcast shaft of the mine. The indicators found at the site included heat haze, sweating and a benzene smell, with elevated levels of carbon monoxide recorded by hand held gas detectors. Prior to this event, there were no known recordings of spontaneous combustion occurring at Mannering Colliery throughout its more than 50-year mine life. In addition, there were very few known recorded occurrences of spontaneous combustion in the Great Northern Seam workings throughout its extensive mining history, although spontaneous combustion events have been known to occur in stockpiled coal on the surface. Figure 1: Location plan of heating site The depth of cover to the Great Northern Seam is generally in the range of 150-210 m and there is typically around 30 m of interburden between the Great Northern Seam and the underlying Fassifern Seam. In-situ gas contents range from 1.6-2.75 m3/t for the Great Northern Seam and 2.4-3.5 m3/t for the Fassifern Seam. The seam gas composition is predominantly methane (>95%). R70 self-heating rate test results indicate an intrinsic spontaneous combustion propensity rating of medium to high for the Great Northern Seam, dependent on the ash content. However, the incubation period for this coal is strongly dependent on a number of site specific parameters and other coal properties. The mine ventilation arrangements in place for more than the past two years, since placing the mine on care and maintenance, consists of a reduced flow of approximately 130 m3/s at a collar pressure of around 600 Pa. Typically, much of the underlying Fassifern Seam workings ventilation air returns up through inter-seam staple shafts and flood ventilates the old Great Northern Seam workings prior to returning to the upcast shaft. The mine has five inter-seam staple shafts that are still in use to some extent. Very few areas of the mine, either in the Great Northern Seam or the Fassifern Seam are effectively sealed. This is typical of the district, which has been mined for in excess of 100 years. 10 12 February 2016 457

The mine uses a Maihak 10 point tube bundle monitoring system. The bottom of each of the staple shafts is monitored to capture all Fassifern Seam workings return air just prior to entering the Great Northern Seam workings. In addition, five other fixed locations are monitored within the Great Northern Seam workings, including the top of the upcast shaft, which captures the total mine return air. Mine atmosphere monitoring also includes the Mining Supervisor underground inspections and hand held monitoring. Bag samples are typically taken monthly from the top of the upcast shaft. GAS MONITORING RESPONSE TO THE HEATING EVENT Initial data and interpretation of the heating event status On Friday 26th June 2015 an IMT was formed consisting of the Mine Manager, the Ventilation Officer and the General Manager of Mines Rescue and Regulation and Compliance. A number of actions were implemented including the mobilisation of the Coal Mines Technical Services (CMTS) gas chromatograph to be onsite as soon as possible as well as planned underground activities to manage and control the incident. All formal notifications had been issued the day before as required by the WH and S (Mines) Act 2013 Part 3, WH&S (Mines) Regulation 2014 CI 179(d): any initial indication that any underground part of a coal mine is subject to windblast, outbursts or spontaneous combustion. The IMT were keen to establish the status of the heating event as this would have implications for the management actions required to control the event. The IMT contacted an external consultant who had previous experience and knowledge of the self-heating behaviour of the Great Northern Seam coal to place the initial gas readings taken the day before and the subsequent gas monitoring results into perspective. Subsequently, an additional consultant with gas monitoring experience was engaged so that the two consultants could work as a team and report back to the IMT on interpretation of the heating event gas monitoring results in response to control actions as they were implemented. At 6:30pm tube bundle sample point #10 was set up on its own purge pump at location 4 shown in Figure 1 and bag sampling commenced every hour, processed via the newly setup gas chromatograph and reported using SmartMate software. The initial downstream gas readings of the heating event at location 4 (Figure 1) indicated a Graham s ratio of 2.54, with ethylene present. The general information in the SmartMate software indicated that for European coals this would correspond to a serious heating. It is also noted that all mines should establish their own levels and that older coals can produce a higher Graham s ratio. None of the literature values take into consideration the status of hot spot development. In 2004, bulk self-heating tests were conducted on coal from Mandalong Colliery in both a gassy as-mined state and non-gassy, dried coal state (Jabouri 2004 and Beamish and Jabouri 2005). The coal tested is analogous to that present at Mannering Colliery (same seam and only 8 km away). The relationship between hot spot coal temperature and Graham s ratio from these tests (Figure 2) indicates that for the Graham s ratio of 2.54 the hot spot temperature is in the range of 110-130 C, depending on how dry the coal is. In the area of the heating event site the coal had been standing for a considerable number of years. Therefore the hot spot temperature was more likely to be closer to the lower end of the temperature range indicated by the Graham s ratio. In addition, this was only a spot reading and subsequently 53 regular readings from 6:30pm 26/6/2015 to 5:56pm 28/6/2015 yielded a Graham s ratio of 2.21±0.10. A review of the data obtained by Jabouri (2004) from bulk self-heating tests of Mandalong coal showed that at the hot spot temperature indicated by the Graham s ratio, the ethylene/ethane ratio becomes a good confirmation indicator of the hot spot development status (Figure 3). When this ratio is 0 it is an indication that the hot spot has not advanced to a significant stewing stage. Once the value increases above 0.3, a well-defined hot spot has formed and the hot spot begins to migrate towards the free surface. The faster this ratio approaches 1 the more rapid the temperature increase becomes with 458 10 12 February 2016

ignition being imminent. This trend in the ethylene/ethane ratio was also confirmed by additional bulk self-heating test results for Mandalong coal obtained from testing conducted in 2010 (Pantano, 2010). The initial bladder sample produced an ethylene/ethane ratio of 0.12. When compared to the results of the bulk self-heating tests of Mandalong coal this indicated a hot spot temperature range of approximately 100-120 C (Figure 2). The slightly lower temperature range indicated by the ethylene/ethane ratio compared to the Graham s ratio may be an artefact of minor ethane seam gas being added to the airstream and thus lowering the ethylene/ethane ratio. Fifty three subsequent readings yielded an ethylene/ethane ratio of 0.12±0.01. Using the ethylene/ethane ratio removes the risk of missing hot spot temperature acceleration due to the dependence on gas indicators obtained from a single gas such as carbon monoxide make for example. An error in the measurement of carbon monoxide due to drift in calibration could also result in a false higher or lower Graham s ratio. Figure 2: Relationship between hot spot temperature and Graham s ratio for Mandalong coal (original data from Beamish and Jabouri 2005) Figure 3: Relationship between hot spot temperature and ethylene/ethane ratio for Mandalong coal (original data from Beamish and Jabouri, 2005) 10 12 February 2016 459

Once the hot spot status had been identified it was possible to provide a more realistic risk assessment to amend the TARP to make use of logical trigger levels. These were assessed by considering the rate of increase in both the Graham s ratio and ethylene/ethane ratio with temperature. Looking at the sensitivities of these two indicators, it was decided to implement a Graham s ratio of 3 and an ethylene/ethane ratio of 0.24 for the Level 3 TARP, as these would indicate a substantial elevation in the hot spot temperature and coincide with the hot spot advancing towards a free surface. Hot Spot Tracking diagram and application to the heating event management and control Having decided on the best gas indicators to monitor the progress of the heating taking place there was a need to present this information in such a manner so that any changes taking place could be readily identified and matched against actions taken to manage and control the heating event. An additional factor was added to this tracking sequence, namely the barometric pressure in case changing natural conditions affected the ventilation and air supply to the heating. Initially separate plots were used for each indicator with a timeline on the X-axis. However, as the event progressed it became apparent that a composite plot was needed for tracking the hot spot development and the response to ventilation changes. Initially, the Graham s ratio was plotted on the left Y-Axis (with a range of 0 to 3, matching the Level 3 TARP trigger) and the barometer was plotted on the right Y-Axis. The values of the ethylene/ethane ratio were approximately 0.12 and the Level 3 TARP trigger had been set at 0.24. It was decided that to enable the Graham s ratio and the ethylene/ethane ratio to be on the same plot a multiplier of 10 should be applied. This composite plot can be termed a Hot Spot Tracking (HST) diagram (Figure 4). Figure 4: Hot spot tracking response from 26/6/2015 to 1/7/2015 Between the commencement of monitoring on the 26/6/2015 and early morning of 30/6/2015 both the Graham s ratio and the ethylene/ethane ratio remained relatively stable even with a falling barometer (Figure 4). This enabled preparatory work to continue unhindered with the eventual aim of sealing off the area. However, by Tuesday afternoon (30/6/2015) after a recalibration of the Gas Chromatograph CO detector it became apparent that the baseline level of the Graham s ratio had increased significantly and the ethylene/ethane ratio was increasing substantially (Figure 4). By late Tuesday evening these values were rapidly approaching the Level 3 TARP triggers. 460 10 12 February 2016

An assessment of possible explosive mix scenarios had been performed throughout the day based on the makes of the various gases and oxygen consumption rate. Given the status of seal-up preparations at that time the only option available to control the air reaching the hot spot was to lower the previously installed rolled up flexible stopping at location 3 (Figure 1) and restrict the ventilation entering the heating site in preparation for a final sealing at location 4 (Figure 1) on the downstream side of the heating. The response to this ventilation control was expected to be a decrease in the gas indicator ratios and a decrease in the oxygen concentration. The response from the implementation of the ventilation intervention of completing stopping #3 was almost immediate with a rapid drop in the ethylene/ethane ratio recorded within approximately three hours. A drop in the Graham s ratio was delayed by almost 12 hours. The on-going drop in both the Graham s ratio and the ethylene/ethane ratio provided confidence in being able to take additional time to organise the final seal-up of the area, particularly as no explosive mix was developing and the oxygen content began to drop noticeably. This was also supplemented with nitrogen injection into the area. Note the CO/CO2 ratio was also added to the HST diagram (Figure 5) at this stage to provide further confirmation of the success of the ventilation intervention. A scaling factor of 60 was applied to bring the value into the same Y-axis range. A similar response in the gas indicators from restricting the ventilation to the incident area was also recorded for a spontaneous combustion event at Spring Creek Mine (New Zealand) in 2008 (Beamish and Hughes, 2009). The assessed hot spot temperature of that event was lower than this one, but the immediate response of the ethylene/ethane decrease was identical. The Graham s ratio response was also delayed. All gas indicator readings continued to decrease after Stopping #3 was completed and approximately two and a half days later the final seal at Stopping #4 was completed with additional nitrogen injection. The Graham s ratio initially increased, but then gradually decreased over time following the seal-up (Figure 5). However, the ethylene/ethane ratio continued to progressively decline indicating that the hot spot was diminishing. Continued monitoring of the sealed area atmosphere recorded the oxygen content decreasing to below 3% and the gas indicator ratios continued to decline, indicating the event was successfully controlled. Figure 5: Hot spot tracking response from commencement of event to seal-up 10 12 February 2016 461

CONCLUSIONS When managing an underground coal spontaneous combustion event it is imperative that the self-heating characteristics of the coal are known so that informed decisions can be made by the IMT based on the understanding of the status of the heating. A recent heating event at Mannering Colliery illustrates the practical advantages of implementing this sound engineering practice. Initial detection of the heating indicated the presence of a hot spot that was able to be interpreted from valid laboratory data as being in a semi-stable stewing stage between 110-130 C. This enabled preparatory work to continue towards sealing the heating in a controlled manner. A new gas indicator ratio, ethylene/ethane was also able to be introduced as confirmation of the hot spot status, which proved to be more sensitive to control measures than the normally used Graham s ratio. Presentation of gas monitoring data to assess cause and effect was identified as crucial to interpretation of the heating event progress to assist with valid risk assessment for management and control. This was achieved by developing a composite plot that contained data for barometric pressure, Graham s ratio and ethylene/ethane ratio. A scaling factor was applied to the ethylene/ethane ratio to enable it to be plotted on the same Y-axis as the Graham s ratio. This new plot was termed a HST diagram as it provided a clear indication of hot spot status and progress as well as the response to control measures adopted. It was also shown that other useful gas indicators such as CO/CO 2 can be added to this diagram with appropriate scaling factors. Staged control of the heating event was achieved by sequential ventilation restriction and sealing of the area. The rapid drop in gas indicators such as ethylene/ethane ratio shows how sensitive hot spot development is to ventilation control. ACKNOWLEDGEMENTS The authors would like to thank Lake Coal for granting permission to publish these results. REFERENCES Beamish, B and Hughes, R, 2009. Comparison of laboratory bulk coal spontaneous combustion testing and site experience A case study from Spring Creek Mine, in Proceedings of the 9 th Coal Operator s Conference, N Aziz and J Namcik (eds), pp 287-295 (The Australasian Institute of Mining and Metallurgy: Melbourne). Beamish, B and Jabouri, R, 2005. Factors affecting hot spot development in bulk coal and associated gas evolution, in Proceedings 6 th Coal Operators Conference, pp 187-193 (The Australasian Institute of Mining and Metallurgy: Melbourne). Jabouri, I, 2004. Investigating self-heating test results of coal from Mandalong Colliery, Undergraduate Mining thesis (unpublished), University of Queensland, Brisbane. Pantano, L, 2010. A review of Mandalong Mine bulk coal self-heating, Undergraduate Mining thesis (unpublished), University of Queensland, Brisbane. 462 10 12 February 2016