G95 Series BASOTROL Single Operator Valve

Similar documents
G96 Series BASOTROL Dual Operator Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G92 Series BASOTROL Automatic Pilot Gas Valve

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGC258 Series BASOTROL Gas Valve

Dual Solenoid Gas Valve Installation

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Operator: Save these instructions for future use!

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

GM Series Dual-Block Multi-Function Gas Control Valves

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

SPECIFICATIONS CAPACITY

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

36H SERIES Combination Gas Valve

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

SPECIFICATIONS ATTENTION

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

SPECIFICATIONS. Normally closed automatic shutoff valve with proof of closure. Fast opening, fast closing. ATTENTION

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Gas Pressure Switch for DMV safety shutoff valves

Instruction Manual No. 742, 8/98

North American 7337A/B/C-4 High Pressure Gas Regulators

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

Gas Pressure Switch for DMV safety shutoff valves

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first O.K. IFGC CSA UL ANSI NFPA

Pressure switch for gas and air

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Pressure Switch for gas and air

Pressure Switch for gas and air GGAO-A4

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

V43 Pressure Actuated Water Regulating Valve

SPECIFICATIONS ATTENTION

Gas Pressure Switch for DMV safety shutoff valves

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

Noth American 7347 High Pressure Gas Regulators

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Gas Appliance Pressure Regulators and. Line Pressure Regulator. FRS 7../6 Series FRS 5... Series

VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

Pressure Switch for gas and air

Line Pressure Regulators Class I or Class II. FRS 7../6 Series

C645A-E Pressure Switches

Service and installation must be performed by a trained/experienced service technician.

R122H, R222, R232A, and R232E Series Instruction Manual

Gas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.

SPECIFICATIONS FRS. 2 1/2 DN (ISO) Flanged. FRS DN (ISO) Flanged

Design Guide /01. ThermAir Burners TA Series version 1.10

Operator: Save these instructions for future use!

Line Pressure Regulator. Class I or Class II. FRS 7../6 Series

LINE PRESSURE REGULATOR GUIDEBOOK 7TH EDITION

Service and installation must be performed by a trained/experienced service technician.

The installation and maintenance of this product must be done under the supervision of an experienced. Safety first IFGC CSA UL ANSI NFPA

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Commonwealth of Massachusetts Approved Product Approval code G

Operator: Save these instructions for future use!

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Operator: Save these instructions for future use!

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Certified LP/Propane Line Pressure Regulator Guidebook

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Your safety and the safety of others are very important.

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

S300 Series. Valve Link. Features. Fisher Controls

Tightness controls TC 1 3 and TC 4

CSA: Certified File No Never perform work if gas pressure or power is applied, or in the presence of an open flame. Safety first O.K.

Operator: Save these instructions for future use!

GENERAL APPLICATION NOTES

CATALOG. 2 nd Edition

Butterfly Control Valve. DMK/6 Series

Transcription:

Product Bulletin Issue Date January 5, 2009 G95 Series BASOTROL Single Operator Valve The G95 Series BASOTROL valves are single operator, automatic valves available with a pressure regulator. For use in applications that do not require solenoid redundancy. Figure 1: G95 Single Operator Gas Valve Features and Benefits Bipolar Magnetic Operator Top or Bottom Regulation Adjustment Compact Design Selectable Tap Positions Numerous Magnetic Operator Cover Styles Available Provides dependable operation and long life Provides application flexibility Permits installation in dimensionally restricted applications Provides application flexibility Allows various mounting options and connection choices to best suit your requirements 2009 BASO Gas Products 1 Code No. BASO-PB-G95, Rev. - www.baso.com

Product Overview Application The valve is suitable for use with natural gas or Liquefied Petroleum (LP) gas at pressures up to 0.5 psi (35 mbar). The silicone diaphragm is suitable for operation over a temperature range of -40 to 175ºF (-40 to 79ºC). Valves with a nitrile diaphragm are suitable for operation over a temperature range of -20 to 175ºF (-29 to 79ºC). Note: This valve should be used only in applications that are within the limitations and provisions of the applicable American National and/or Underwriters Laboratories standards. Description The valve is equipped with one BASOTROL bipolar magnetic operator. Bipolar construction reduces the possibility of the valve sticking in the open position from residual magnetism or from mechanical interference. A leak limit orifice is supplied as standard on valves with a regulator stack. Valve Constructions The G95 series is available with 1/2 x 1/2 in. or 1/2 x 3/4 in. body connections with 25, 120, 240 VAC, or 12 VDC 2-wire magnetic operators. Refer to the Ordering Information section for more information. Additionally, the G95 series is available with other optional configurations. Pressure Connections The valve is available with 1/8-27 NPT pressure taps when required. Contact BASO Gas Products for details and ordering. Magnetic Operator Cover Styles An aluminum magnetic operator cover with conduit hub and 30 in. (762 mm), 18 American Wire Gauge (AWG) stranded lead wires are supplied as standard on all line voltage models. The leads and hub position may be located at the top, over the inlet, on the right side, or on the left side of the valve. Lead wires with 1/4 in. (6.35 mm) quick-connect terminals are also available. The Underwriters Laboratories (UL), Inc. Listed steel operator cover is available with a top conduit hub only. A plastic magnetic operator cover with 1/4 in. (6.35 mm) quick-connect male terminals is supplied as standard on all low-voltage models. However, an aluminum or steel operator cover with conduit hub is available. Contact BASO Gas Products for details and ordering of magnetic operator cover style and wiring requirements. Regulator/ Tap Options The valve is designed for various configurations. The top adjust or bottom adjust regulator, and right- or left-hand pilot tap options take advantage of space access limitations. Mounting The valve may be mounted on a horizontal manifold with the magnetic operator pointed up (vertical) or in a position not exceeding 90º from vertical. The valve may be mounted on a vertical manifold in any position around its axis. 90º 90º Horizontal mounting limited to 90º from upright. Vertical mounting may be 360º around its axis with the gas flow either up or down but always in the direction of the arrow. Figure 2: Mounting Positions 2 G95 Series BASOTROL Single Operator Valve Product Bulletin

Magnetic Operator Burner Manual Shutoff Valve Bottom Adjust Regulator Figure 3: Typical G95 Installation Dimensions 4.573 116.15 3.448 87.58 Note: Bottom Adjust Regulator Width Dimension is 2.676 in./67.97 mm 4.243 107.76 Note: Bottom Adjust Regulator Height Dimension is 5.393 in. /136.98 mm Figure 4: Dimensions Range of Regulation Table 2: Range of Regulation Inlet/Outlet Q MINIMUM Q MAXIMUM in. NPT cf/h m 3 /h cf/h m 3 /h 1/2 x 1/2 20 0.57 200 5.7 1/2 x 3/4 20 0.57 250 7.1 Note: 1 m 3 /h = 10.67 kw (cf/h - 1,000 Btu/hr) natural gas at 0.64 specific gravity. For LP flow rates, see Figure 5. G95 Series BASOTROL Single Operator Valve Product Bulletin 3

Ordering Information G 9 5 _ - Customer-specific Requirements Regulator Type A = Top Adjust (Right): 3 to 6 in. W.C. (7.5 to 15 mbar) B = Top Adjust (Right): 6 to 12 in. W.C. (15 to 30 mbar) L = Bottom Adjust: 3 to 6 in. W.C. (7.5 to 15 mbar) M = Bottom Adjust: 8 to 12 in. W.C. (20 to 30 mbar) A = B = C = D = F = G = U = V = Voltage 120V, 60 Hz 240V, 60 Hz 120V, 60 Hz 240V, 60 Hz 25V, 60 Hz 25V, 60 Hz 12VDC 12VDC MOA Location A = B = Capacity Btu/hr kw 190,000 56 190,000 56 Inlet/Outlet 1/2 x 1/2 in. NPT 1/2 x 3/4 in. NPT The presence of a particular construction in this information does not guarantee its availability. Consult BASO Gas Products for available constructions. Figure 6: Ordering Matrix 4 G95 Series BASOTROL Single Operator Valve Product Bulletin

Technical Data Product Maximum Operating Pressure Permissible Ambient (Surface) Temperature Available Magnetic Operator Cover Styles Electrical Rating Regulator Adjustment Range Inlet Pipe Size Outlet Pipe Size Outlet Wiring Connections Types of Gas G95 Series BASOTROL Single Operator Valve 0.5 psi (35 mbar) -20 to 175 F (-29 to 79 C) nitrile diaphragm -40 to 175 F (-40 to 79 C) silicone diaphragm Aluminum side conduit hub Aluminum top conduit hub Aluminum top without conduit hub Aluminum side outlet with eyelet Steel top conduit hub Plastic with 1/4 in. (6.35 mm) male quick-connect terminals 25 VAC, 60 Hz, 0.3 ampere draw 120 VAC, 60 Hz, 0.05 ampere draw 240 VAC, 60 Hz, 0.03 ampere draw 12 VDC, 0.5 ampere draw Bottom Adjust Regulators: Top Adjust Regulators: 1/2 in. NPT 1/2 or 3/4 in. NPT 1/8 in.-27 NPT, 1/4 in. cc also available 3 to 6 in. W.C. (7.5 to 15 mbar) 8 to 12 in. W.C. (20 to 30 mbar) 3 to 6 in. W.C. (7.5 to 15 mbar) 6 to 12 in. W.C. (15 to 30 mbar) 1/4 in. (6.35 mm) male quick-connect or 30 in. (762 mm) lead wires (other lengths are optional) Natural or Liquefied Petroleum (LP) Accessories Conversion Kits: Natural Gas to LP Gas: Packaging Bulk Pack Quantity Bulk Pack Weight LP Gas to Natural Gas: Top Adjust Regulator Bottom Adjust Regulator Top Adjust Regulator Bottom Adjust Regulator Bulk pack supplied to original equipment manufacturer (individual pack optional). 32 per carton 41 lb (19 kg) per carton Agency Listings CSA Certificate Number 229521-1656041 Specifications Standards ANSI Z21.78, CSA 6.20 Y71GF-4 Y71GF-3 Y71QH-2 Y71QH-3 Performance specifications are nominal and conform to acceptable industry standards. All agency certification of BASO products is performed under dry and controlled indoor environmental conditions. Use of BASO products beyond these conditions is not recommended and may void the warranty. Product must be protected if exposed to water (dripping, spraying, rain, etc.) or other harsh environments. The original equipment manufacturer or end user is responsible for the correct application of BASO products. Consult BASO Gas Products LLC for questionable applications. BASO Gas Products LLC shall not be liable for damages or product malfunctions resulting from misapplication or misuse of its products. Refer to the G95 Series BASOTROL Single Operator Valve Installation Instructions (BASO-INS-G95) for necessary information on the installation, use, and servicing of this product. 1007 South 12th Street PO Box 170 Watertown, WI 53094 www.baso.com 1-877-227-6427 (1-877-BASOGAS) Printed in U.S.A. G95 Series BASOTROL Single Operator Valve Product Bulletin 5