VHC Vitamin-D Accurate Sample Preparation. VHC Vitamin-D Quantitative Vitamin D Test [REF] 1000J-10/-25/-50

Similar documents
Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Pendant Drop Measurements

HemoCue Hb Procedure Template

Specimen Collection. Lead Screen Filter Paper Testing Dried Blood Spots (DBS) Laboratory Services February 2017

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Granulocyte Colony Stimulating Factor (hg-csf) Ultrasensitive Assay

Gel Loading Practice MiniLab

ab IgG1 Human ELISA Kit

Oxygen Sensor with Electrode

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

VOLUMETRIC TECHNIQUES

4 CONTROL-CHART EXAMPLES

RayBio Human vwf ELISA Kit

COLLECTION OF BLOOD. Types of patients

User Manual. Quantos Automated Dosing Liquid Module

Rat myeloperoxidase-antineutrophil cytoplasmic antibody(mpo-anca) ELISA Kit

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Human ABCD1 ELISA KIT

Technical Procedure for General Laboratory Equipment

Pipettor. User Manual

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Module 14: Blood Collection and Handling DBS

Automated Liquid Handling Station

HemoCue Training and Education Program. Capillary Sampling. Hemoglobin. USPRO1 Rev 1 3/03. Training and Education Program 2003 HemoCue, Inc.

CspB ELISA Kit DAS ELISA for the detection of CspB protein Catalog number: PSP 35500

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

RayBio Human TNF-alpha ELISA Kit

Pipetting and Determining Protein Concentration

Flow experiment with the ibidi pump system and µ-slide I 0.6 Luer

TapeStation Tips & Tricks

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: July 2010 REVIEWED DATE: May 2017 PRINCIPILE:

VividTrac R. Video Intubation Device. INSTRUCTIONS FOR USE. English

biosensis Human IGF-II, Insulin-like growth factor II, Somatomedin-A ELISA Kit Protocol

biosensis Rat Fibronectin ELISA Kit Protocol

Register your instrument! Eppendorf Xplorer / Eppendorf Xplorer plus. Adjustment

Lab Equipment ANALYTICAL BALANCE

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

biosensis Human TNFα/Cachectin/TNFSF2 ELISA Kit Protocol

Pipetting Small Volumes

RayPette Plus Autoclavable Pipette. User Manual

6900 Maintenance Instruction System Flush

256 Pneumatic Pressure Indicator

Lab Skills Practice: Pipetting Small Volumes. B3 Summer Science Camp at Olympic High School 2016

Students measure the change in pressure by varying the volume of trapped air in a syringe while:

Bt-Cry1Ac & Bt-Cry2A Multi-trait ELISA Kit DAS ELISA for the detection of Bt-Cry1Ac & Bt-Cry2A proteins Catalog number: PSM 14900

WHITEPAPER. Integrated process monitoring of dosing pressures

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

biosensis Mouse CXCL10/IP-10 ELISA Kit Protocol

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

M.M.C. International B.V.

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

RayBio Human IFN alpha/beta R2 ELISA Kit

Chemistry Safety Packet

The pipettes cover a volume range from 0.1µl to 10ml.

Bt-Cry2Ab and Bt-Cry3Bb1 Multi-trait ELISA Kit DAS ELISA for the detection of Bt-Cry2Ab and Bt-Cry3Bb1 proteins Catalog number: PSM 26800

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Operating Manual Body fat balance

Analysis of Deuterium Enrichment by Fourier Transform Infrared Spectrometry (FTIR): Practice. Christine Slater PhD

HOW TO MANAGE VAPORIZATION IN AN ANALYTICAL SYSTEM By Dean Slejko and Tony Waters

New power in production logging

Chapter 2. Pipetting techniques. Guide to Pipetting

SPECIFICATIONS APCEPH1

Operator Quick Guide ORBISPHERE 3654

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Measuring Mass and Volume

Quick Reference Guide

User Manual. Quantos Automated Dosing Powder Module

Solutions for transcutaneous monitoring

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

biosensis Human Lipocalin-2/NGAL ELISA Kit Protocol

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

TEST SPECIFICATION NYT-909-C

Calibration of Volumetric Glassware

Qi Litre Ultrasonic Cleaner

BASIC LABORATORY TECHNIQUES (Revised )

130 SSP Soluble Salt Profiler

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Improving Pipetting Techniques

biosensis Mouse Vascular endothelial growth factor A/VEGF-A/VEGF-164/VEGF-1/VEGF- 120/VEGF-2 ELISA Kit Protocol

USING HAZOP TO IDENTIFY AND MINIMISE HUMAN ERRORS IN OPERATING PROCESS PLANT

BSS 2 Bottle Sampling System. Instruction manual Version 1.8

MSD 96-Well MULTI-ARRAY Human (6E10) Abeta 40 Ultra-Sensitive Kit

Mare Foaling Predictor Kit

biosensis Human Soluble Tumor Necrosis Factor receptor type II (stnfrii) ELISA Kit Protocol

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Real World Metric System

Prepared By: Lisa McAvoy 30/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Eclipse Precision & Analytical Balances

User Manual MFCS TM -EZ

INTERNATIONAL STANDARD

LogIT Dissolved Oxygen Probe

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

Before you start sampling, be sure to read

GAS FILLING MACHINES PROCESS MONITORING PRESSURE BALANCE

Transcription:

VHC Vitamin-D Accurate Sample Preparation vitality-health-check.com/service/vhc-vitamin-d-accurate-sampling-sample-preparation VHC Vitamin-D Quantitative Vitamin D Test [REF] 1000J-10/-25/-50 NOTE: THE ORIGINAL/REFERENCE VERSION OF THIS DOCUMENT IS THE ENGLISH VERSION. Training Document for Professional Users For Self-Study and Reference The VHC Vitamin-D test is an innovative Point of Care Vitamin D test for professional use, providing lab-grade results within 15 minutes. There has been a thorough, robust, and reliable process development of the test within the cassette. The VHC Vitamin-D enables the consultant and therapist to measure the important health parameter Vitamin D directly and anywhere at the Point of Care. It remains your responsibility as professional user to assure a thorough sample preparation and therefore a quality reading. The UniSampler supports you doing this with high precision. We provide this document, to support you when implementing and processing the VHC-Vitamin-D tests. It serves as instruction material for reference and self-training for the professional user. It is very important the user is focused and controls each handling step when collecting and preparing the sample. If the quantity of the applied sample is incorrect or was not mixed thoroughly, the quality of result of the reading will be impaired. The UniSampler Your Minilab for Measuring, Mixing, and Applying the Sample When running a quantitative test like the VHC Vitamin-D, the sample preparation is crucial for the quality of the reading. With the help of the UniSampler your work at the Point of Care will be as precise and controlled as in the professional lab. Therefore, it is important to exactly know which effects can happen that can influence the sample preparation in the UniSampler. 1/9

During Sample Preparation, the UniSampler is Always Engaged The capillary (a) integrated in the Blood Collector measures exactly 10 μl whole blood. For further sample preparation, the Blood Collector with the sample in its capillary is attached to the Collection Tube pre-filled with 5 drops of sample buffer so that the capillary tip can submerse. The sample is removed from the capillary into the buffer and mixed in the UniSampler. There is a second capillary integrated underneath the cap of the Blood Collector (b). It connects to a cone-shaped dropper (d). To start the test, you use this dropper to apply 3 drops of the prepared sample to the sample well of the test cassette. The UniSampler consists of: Collection Tube and Blood Collector with the sample capillary (a) and a cap (b). When attached, both parts form the sample mixer with the sample outlet (c, d) underneath the cap (b). The UniSampler Precise Measuring, Mixing and Application The UniSampler was developed to support accurate measuring, mixing and applying the sample. The integration of the sample-capillary and the dropper in the Blood Collector of the UniSampler allows precise sampling without further tools, provided you utilize the UniSampler correctly and monitor each procedure step closely. Prepare Sample Buffer Carefully Provide Exactly 5 Drops of Buffer 2/9

It is important to accurately measure the 5 drops of sample buffer to gain a correct relation of the sample dilution! If you accidentally use one drop more or less or the drop size is not equal it will influence the quantitative result! Work calmly and diligently! Pay attention that the dropper of the sample buffer bottle is bubble free before you start to drip in to the Sample Collector. Drip slowly with equal pressure. The Specific Task of the Sample Buffer Regarding the Test Process Vitamin D is fat-soluble. Therefore, it is preferentially stored in the fat tissue. Within the blood it is bound to the Vitamin-D-Binding Protein (VDBP) to facilitate transportation in the blood stream. The particular consistence of the sample buffer forces the effective release of all Vitamin D during mixing of sample and sample buffer. Effective, complete Vitamin-D release from the VDBP is the prerequisite for later Vitamin D detection and quantification on the cassette. 3/9

A Sample buffer is applied. Vitamin D is already released from Vitamin-D-Binding Protein. B Continuous lateral flow on the strip. Antibodies mark free Vitamin D. C The control line forms first, the test line increases dynamically until the end of the test. Sampling with the UniSampler 10 μl Whole Blood Exactly Measured It is important that the finger selected for collecting the sample is warm and well perfused in order to achieve a good sample quality. Eventually, it is recommended to soak the finger in warm water or massage it lightly. Once the fingertip is punctured with an appropriate lancet there is often only a small drop of blood that should be wiped off with a tissue so that the wound will not close immediately. In case there is only a minor blood flow, massage the finger carefully. Do not milk out! The second drop of blood should be about 2 3 mm in size in order fill the capillary of the Blood Collector completely. Monitor this process exactly! If the capillary is not full or contains bubbles you are not applying the right volume and this will impair the reading. It is always better to puncture a second time or use a second capillary rather than to conduct the VHC Vitamin-D Test with an inferior sample. 4/9

When inserting the Blood Collector with the filled capillary downward into the Collection Tube of the UniSampler until the tip is submersed in the sample buffer pay close attention that the capillary does not accidentally touch the edge or the inside of the Collection Tube. Work thoroughly! Otherwise a part of the sample could be lost. Close the UniSampler carefully by tightly attaching the Blood Collector to the Collection Tube until it is sealed. Sample and Sample Buffer in the UniSampler Mix Very Thoroughly! It is of the utmost importance for the quality of the reading that the sample and the buffer are completely mixed. Jerky movements with enough pep of the capillary results in ejecting the sample and subsequent panning with the remainder will ensure a complete mixture. Every user will individually optimize these mixing movements after a few tests. Work thoroughly and monitor exactly for full depletion of the sample from the capillary and complete mixing. Only multiple and bold spinning and panning will lead to full capillary depletion and complete mixture! Avoid bubble forming! Keep UniSampler tightly sealed! Control with transmitted light! In order to control that the sample and sample buffer are completely mixed, you must observe the UniSampler with transmitted light multiple times. In the beginning the capillary has a distinct intense coloration since the capillary forces still retain most of the sample (A). After complete depletion and mixture, the capillary finally appears a little bit lighter with transmitted light than the sample mixture at the bottom of the Collection Tube of the UniSampler (C). 5/9

If you do not mix with enough force a large part of the sample remains in the capillary (A). Should the pre-mix from several drops while mixing, make sure to reconnect them again, by slowly panning the UniSampler. It is important that the pre-mix sample is completely mixed and bubble free before applying the sample and accumulates at the bottom of the Collection Tube (C). Work this step especially thoroughly and monitor multiple times with transmitted light! Sample Application Apply Full 3 Drops onto Test Cassette! The cap of the Blood Collector covers the sample outlet or the drip tube (A) which is used to apply the sample. Again, this important step requires correct measuring. Forming of bubbles in the drip tube (B, C) may lead to a wrong volume. Pay attention that the drip tube of the UniSampler is always bubble free (D). You must work thoroughly during application onto the test cassette. If a drop touches the surface of the membrane or the previous drop before it is completely formed it will rupture and subsequently not have enough volume. In addition, an embedded air bubble can change the drop volume. 6/9

Work thoroughly! Drip 3 full drops! The volumes are important! Read after Exact 15 Minutes. Vitamin-D-Signal Increases Dynamically! After the sample application, a continuous lateral liquid flow is established in the strip. This creates a controlled process. Pay attention to the clear forming of the control line. The test line appears after some minutes. The Vitamin D signal is dynamically gaining intensity as long as the test performs. Exactly 15 minutes after applying the sample, the test must quantified with the VHC- Reader. LOT specific calibration data are stored on the RFID card, used to program the VHC- Reader. Pay attention and always check that you use the correct RFID card. Compare the LOT-numbers of the test pouch and the RFID card. Control the Test Process Test successfully performed A Strong signal B Weaker signal Check Control Line! Error images (repeat test) C Test not completed not enough buffer? D Control line is missing E Control line unclear 7/9

Control the Test Process Check Control Line! Frequently Asked Questions FAQ How do you proceed if the VHC-Reader shows an error although the test has completed successfully and the control line is clearly visible? Check if you have accidentally inserted the test cassettes in the adapter the wrong way. In this case the VHC-Reader reads the test line as the control line and indicates an error. Also check that the batteries in the VHC-Reader are sufficiently charged. If necessary you can also operate the VHC-Reader with the optional USB-adapter cable (DataReader cable). What do you do if the control line at the end of the test is not clearly visible or fuzzy in spite of completely applying the sample? In this case, the test within the cassette has not processed correctly and the Test result must be discarded and the test repeated. Take a photo of a test with a control line indicating an error. Please send us this photo by email together with your contact information and describe briefly yourobservations. We will contact you immediately. What is the effect if the mixture of the sample buffer is not correct? Without enough pep when mixing the sample will only exit slowly from the capillary. If the depletion of the sample from the capillary is not monitored exactly it could be that the mixture contains not enough sample. The reading tends to deviate downwards. What happens if you apply less than 3 whole drops of sample mixture on the test strip? By applying the pre-mix a continuous lateral flow is generated on the strip of the test cassette which expedites the test process. If the sample inlet becomes dry prematurely due to missing pre-mix volume the test will not run for the full 15 minutes. A weak test line is the result due to a dynamically increasing Vitamin-D-signal over the full 15 minutes. If you are 8/9

still unsure although working thoroughly apply another drop if necessary. It is important that the sample inlet does not become dry during the entire test process. In doubt, a little too much buffer is not harmful. How long do the batteries in the VHC-Reader last? If you use the VHC-Reader only for instant readings and not in the timer modus, the batteries last for up to 100 readings. The more often you use the timer modus, the more battery power is used. If you mostly work in timer modus, you may prefer to operate the VHC-Reader with the special USB adapter cable (DataReader cable). It is available as bundle together with the DataReader software, connection the VHC-REader withj PC. Where do I find information, videos and training material regarding the VHC Vitamin- D test online? Please refer to the service on our homepage. http://www.vitality-health-check.com/service We shall update this material from time to time based on your feedback This is Version 1.1 Created in February 2018 Copyright 2017 Jungbrunnen Fountain of Youth GmbH www.vitaöity-health-check. NOTE: THE ORIGINAL/REFERENCE VERSION OF THIS DOCUMENT IS THE ENGLISH VERSION. Copyright 2018 Jungbrunnen - Fountain of Youth GmbH. All rights reserved. 9/9