OC508 Programmable mv Calibrator

Similar documents
Oxygen Meter User Manual

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Sensoric 4-20 ma Transmitter Board Operation Manual

Manual Weighingblock VB2 series and Uniscale

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Connections The C20B can be connected either using the Molex locking socket, or by connection to four plated through holes. The plated through

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Pneumatic high-pressure controller Model CPC7000

AMS 6915 Board mount pressure sensor with digital output (I²C)

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Pneumatic high-pressure controller Model CPC7000

CONTROL and INSTRUMENTATION

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

AMS 2710 PCB pressure sensor module with V output

BI-680 Online Dissolved Oxygen Controller Instruction Manual

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases

HumiSys HF High Flow RH Generator

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

TH-1800-T TRX-700-CNG Converter

MARTINI. instruments. THANK YOU FOR CHOOSING. Sales and Technical Service Contacts:

NOVATECH OXYGEN /CARBON DIOXIDE ANALYSER /TRANSMITTER MODEL 1537

Digital Pressure Gauge Main features: Data Sheet: DFP.418.R4.EN

BUBBLER CONTROL SYSTEM

Hand-held pressure calibrator with integrated pump Model CPH6600

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

FTC300. Fast Thermal Conductivity Analyzer. Operating Manual

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SonoMeter 30 Energy Meters

ISM-3 User Manual PBI D 04/2013

DeeterFlow Automatic Liquid Dispenser

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

FTC130 Transmitter. Operating Manual

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Manual Oxygen Analyzer A4009T

e2c 20 - easy to connect

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

Overview. Front Panel: Keypad and Display

Instruction Manual. BZ7002 Calibration Software BE

ECL Comfort 110, application 131 (valid as of software version 2.00)

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

AUTO PUMP STATUS CENTER

Mass Flow Controller (MFC) for Gases

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Bypass Mass Flow Controller (MFC) for gases

REASONS FOR THE DEVELOPMENT

Optical Dissolved Oxygen Meter

C-Flow Coriolis Mass Flow Meters

AMB MOISTURE BALANCE AMB 50, AMB 110 and AMB 310. Operating Manual

PRODUCT MANUAL. Diver-MOD

Mass Flow Controller (MFC) for Gases

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

CF8-W-Disp-CO. User manual. CO 2 / CO sensor with built-in general purpose controller

APA software instruction manual

Installation and Operation Manual

GasSense NDIR User Manual

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

Built-in Purge Control Functions

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Additel 761 Automated Pressure Calibrators

Installation and Operating Instructions for Blow Down Controller Type LRR 1-12

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

KEM Scientific, Inc. Instruments for Science from Scientists

AMS 6916 Board mount pressure sensor with ratiometric analog output

Experiment AMe-1: Small Animal Respiratory Exchange Ratio (RER)

OPERATING INSTRUCTIONS FOR LXT-280. Dissolved Oxygen Transmitter DANGER

Automatic Isokinetic Sampler. ST5 Evo

KERN EG/EW Version /02

Manual of SF6 Comprehensive Tester

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

Optical Dissolved Oxygen Meter

APPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S

Additel 761 Automated Pressure Calibrators Selection Guide

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

BAPI Pressure Line of Products - FAQs

PCDY01 Dissolved Oxygen Meter

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Electronic gas volume corrector model DGVC-04

BUBBLER CONTROL SYSTEM

TR Electronic Pressure Regulator. User s Manual

EPP4 Pressure Regulator Basic G 1/4"

Design Features. General Description

SENSORS Pressure CALDARO

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

Stand-Alone Bubble Detection System

Model 4040/4043/4045 General Purpose Thermal Mass Flowmeter

Description. Measuring Device 3760XBI USP. Balancing

Transcription:

OC508_GBM_201609 OC508 Programmable mv Calibrator Owner s Manual Orbit Controls AG Zürcherstrasse 137 CH8952 Schlieren - ZH orbitcontrols.ch

OC508 Programmable mv Calibrator Selection of DIN Thermocouples Measurement of mv Signals Calibrated Signal Output 0-65.535mV Junction Simulation Control with BCD parallel or Binary, Keyboard or USB Port BCD parallel all Data Output USB Control with PC SoftManager FUNCTION Measurement and Simulation of Thermocouples with Junction Compensation. Generation and Measurement of mv Voltages. Temperature Measurement with external Pt-100. Control with Front Keys, BCD parallel, Binary or USB from a PC BCD parallel or binary coding is factory set. Model OC508 is a programmable mv Calibrator and Simulator of DIN Thermocouples. The type of the Thermocouple, the Temperature or the mv Signal can be set from the keys at the front, via USB or optionally from BCD parallel or Binary Data Port. The generated mv output signal ranges between 0mV and 65.535mV. The output can be set directly in mv or in Temperature C through the selected internal linearizing DIN T/C table. The basic unit is a precision, temperature compensated programmable voltage source with a resolution of 1µV and stability of 10ppm. It is free programmable from 0 to 65535µV. The measurement of external mv Signals has the basic range of ±100mV. It is jumper selectable for other signals. The measuring chain can be calibrated from the keyboard in the Calibration Submenu. SoftManager OC508W for Windows is available for controlling OC508 from a PC via the USB Port. The Data can also be entered from BCD parallel or Binary Ports, permitting operation from programmable controllers. Generated signals are available at a BCD parallel port for further use. For Junction compensation an external 4W Pt-100 can be used. The measured ambient temperature is displayed at the LCD front panel display and available at the BCD parallel port. mv Input: mv Voltage or Temperature from Thermocouples B,E,J.K.N.R,S,T will be displayed. The voltage has three digits resolution -99.999 to 99.999. The Temperature has one digit resolution. Ranges: +/- 100mV (other ranges selectable with jumpers) Values out of range are displayed as: INPUT UNDEFINED! EINGANG UNDEFINIERT! mv Output: mv Voltage or Temperature of the selected Thermocouple B,E,J.K.N.R,S,T can be selected. Range: 0 to 65.535mV. Values out of range are displayed as: OUTPUT UNDEFINED! AUSGANG UNDEFINIERT!

Terminals: External Pt-100, four wire connection Data Bus: USB or BCD parallel or Binary Inputs and Outputs Display: LCD 2x20 Dot Matrix, Background illuminated for 10 min. after key pressed Supply: 230VAC or 24VDC Data: - USB Input and Output with selectable Baud Rate (Serial Control) - BCD parallel Inputs and Outputs, 5 Digits with sign, positive Logic - Binary parallel Inputs, 18 Bit coding with sign, positive Logic PLEASE NOTE: BCD parallel or binary coding is factory set Firm Ware. PRINCIPLE of OPERATION SETTINGS Four modes of operation are selectable: SETUP VALUE SELECTION MEASURING MODE MENU Left Key: After Switch-on: SETUP (HTEST). During Measurement: MENU. Middle Key: During Measurement: Value Selection During Selection: Cursor Movement In Menu: Position select Right Key: During Measurement: Tare In Menu: Return to Measurement In Setup: Return to Measurement Dung the Selection: Cursor-flashing digit-increase 1. SETUP - Calibration of Pt-100 @ 100 Ohm. - Calibration of the input. - Check of the Input and Output Functions of the BCD data. Check of the DAC for Output Voltage and for generating of the Output. 2. VALUE SELECTION - Selection of mv or ºC values of Input and Output 3. MEASUREMENT - Measurement of the input Voltage, the Temperature and the selection of the Output voltage. - The input values of Voltage and Temperature are transformed into BCD. - The Data at the UBS are active after a command.

4. MENU 4.1 Output Selection T/C OUTPUT LINEAR TYPE B TYPE E TYPE J TYPE K TYPE N TYPE R TYPE S TYPE T T/C AUSGANG LINEAR TYP B TYP E TYP J TYP K TYP N TYP R TYP S TYP T 4.2 ON and OFF the Junction Compensation for the Output. During the Measurement, when the Simulation the activated, the display shows the junction temperature. OUTPUT COLD JUNCTION COLD JUNCTION OFF COLD JUNCTION ON AUSGANGSKOMPENSATION KOMPENSATION AUS KOMPENSATION EIN 4.3 Input Signal Selection T/C INPUT LINEAR TYPE B TYPE E TYPE J TYPE K TYPE N TYPE R TYPE S TYPE T T/C EINGANG LINEAR TYP B TYP E TYP J TYP K TYP N TYP R TYP S TYP T 4.4 ON and OFF the Junction Compensation for the Input. During the Measurement, when the Simulation the activated, the display shows the junction temperature. INPUT COLD JUNCTION COLD JUNCTION OFF COLD JUNCTION ON EINGANG KOMPENSATION KOMPENSATION AUS KOMPENSATION EIN 4.4 Filter Selection for the Input Signal INPUT FILTER EINGANGSFILTER OFF AUS FI. 1 FI. 1 FI. 2 FI. 2 FI. 3 FI. 3 FI. 10 FI. 10 FI. 20 FI. 20 FI. 30 FI. 30 FI. 40 FI. 40 FI. 50 FI. 50 FI. 60 FI. 60 FI. 70 FI. 70 FI. 80 FI. 80 FI. 90 FI. 90 FI. 100 FI. 100

4.5 Source selection for the Output Voltage or Temperature INPUT DATA PORT DATENEINGANG MANUAL MANUELL with Keys at the front Manual Entry BCD (Binary) BCD (Binär) via parallel Ports (rear panel) USB USB via USB from a PC 4.6 Language LANGUAGE ENGLISH SPRACHE DEUTSCH 4.6 Baud Rate of the Data Port: 9600, 19200, 57600, 115200, 230400 Bd BAUD RATE BAUD RATE

MANUAL ENTRY T/C OUTPUT = LINEAR By selection MANUEL of the Data Input, the mv value can be set like: Confirm with when the display shows MANUAL. The flashing digit can be set with between 00.000 and 65.534mV. Switch over into the Output Mode with. T/C OUTPUT = one of DIN Thermocouples By selection MANUEL of the Data Input, the Temperature can be set like: Confirm with when the display shows MANUAL. The flashing digit can be set with within the temperature table of the selected Thermocouple. Switch over into the Output Mode with. TARE The Tara refers to the measured signal. The right front key activates the Tare When pressed for a second time the Tare will be deactivated. Tare activated: Press the key once Tare ON Tare OFF Tare deactivated: Press the key again Tara EIN Tara AUS USB INTERFACE Protocol Input: R +<CR><LF> Transmission enabled. (Periodical after each measuring sample) S +<CR><LF> End of Transmission X + x + Number+<CR><LF> Output Value Selection Remark: The Function DATA INPUT = DATA OUTPUT USB has to be activated. X Meaning x Meaning A Linear Input a Linear Output B T/C-B Input b T/C-B Output C T/C-E Input c T/C-E Output D T/C-J Input d T/C-J Output E T/C-K Input e T/C-K Output F T/C-N Input f T/C-N Output G T/C-R Input g T/C-R Output H T/C-S Input h T/C-S Output I T/C-T Input i T/C-T Output Remark: By missing X or x the value will not be set. Output: X + x +Number1+ ; +Number2+ ; +Number3<CR><LF> Number1: Measured value Input (mv or ºC) Number2: Measured value Junction (ºC) Number3: Selected Output (mv or ºC)

TERMINALS for BCD parallel Rear panel Input T/C-BCD Output T/C-BCD Output Pt-100-BCD In: ED.CBA mv Out: ED.CBA mv Out: ED.CBA mv In T/C: EDCB.A C Out T/C: EDCB.A C Out T/C: EDCB.A C Pin D-SUB 25F Weight Pin D-SUB 25F Weight Pin D-SUB 25F Weight 1 A-BCD 1 1 A- BCD 1 1 A- BCD 1 2 A- BCD 2 2 A- BCD 2 2 A- BCD 2 3 A- BCD 4 3 A- BCD 4 3 A- BCD 4 4 A- BCD 8 4 A- BCD 8 4 A- BCD 8 5 B- BCD 1 5 B- BCD 1 5 B- BCD 1 6 B- BCD 2 6 B- BCD 2 6 B- BCD 2 7 B- BCD 4 7 B- BCD 4 7 B- BCD 4 8 B- BCD 8 8 B- BCD 8 8 B- BCD 8 9 C- BCD 1 9 C- BCD 1 9 C- BCD 1 10 C- BCD 2 10 C- BCD 2 10 C- BCD 2 11 C- BCD 4 11 C- BCD 4 11 C- BCD 4 12 INFO 12 Reserve INFO 12 Reserve INFO 13 GND 13 GND 13 GND 14 C- BCD 8 14 C- BCD 8 14 C- BCD 8 15 D- BCD 1 15 D- BCD 1 15 D- BCD 1 16 D- BCD 2 16 D- BCD 2 16 D- BCD 2 17 D- BCD 4 17 D- BCD 4 17 D- BCD 4 18 D- BCD 8 18 D- BCD 8 18 D- BCD 8 19 E- BCD 1 19 E- BCD 1 19 E- BCD 1 20 E- BCD 2 20 E- BCD 2 20 E- BCD 2 21 E- BCD 4 21 E- BCD 4 21 E- BCD 4 22 E- BCD 8 22 E- BCD 8 22 E- BCD 8 23 Sign 23 Sign 23 Sign 24 Reserve STB 24 STB 24 STB 25 GND 25 GND 25 GND Pt-100 TERMINALS Rear Panel Pt-100 Pin Meaning 1 2 Sens + 3 4 Excitation - 5 Sens - 6 7 8 Excitation + Logic Control Log 0 = GND Log 1 = 5 24V

TERMINALS for BINARY Coding - Rear Panel Input T/C-BCD Output T/C-BCD Output Pt-100-BCD In: ED.CBA mv Out: ED.CBA mv Out: ED.CBA mv In: T/C: EDCB.A C Out T/C: EDCB.A C Out T/C: EDCB.A C Pin D-SUB 25F Description Pin D-SUB 25F Description Pin D-SUB 25F Description 1 1 1 A- BCD 1 1 A- BCD 1 2 2 2 A- BCD 2 2 A- BCD 2 3 4 3 A- BCD 4 3 A- BCD 4 4 8 4 A- BCD 8 4 A- BCD 8 5 16 5 B- BCD 1 5 B- BCD 1 6 32 6 B- BCD 2 6 B- BCD 2 7 64 7 B- BCD 4 7 B- BCD 4 8 128 8 B- BCD 8 8 B- BCD 8 9 256 9 C- BCD 1 9 C- BCD 1 10 512 10 C- BCD 2 10 C- BCD 2 11 1024 11 C- BCD 4 11 C- BCD 4 12 INFO 12 Reserve INFO 12 Reserve INFO 13 GND 13 GND 13 GND 14 2048 14 C- BCD 8 14 C- BCD 8 15 4096 15 D- BCD 1 15 D- BCD 1 16 8192 16 D- BCD 2 16 D- BCD 2 17 16384 17 D- BCD 4 17 D- BCD 4 18 32768 18 D- BCD 8 18 D- BCD 8 19 65536 19 E- BCD 1 19 E- BCD 1 20 Do Not Use 20 E- BCD 2 20 E- BCD 2 21 TC Selection 21 E- BCD 4 21 E- BCD 4 22 TC Selection 22 E- BCD 8 22 E- BCD 8 23 TC Selection 23 Sign 23 Sign 24 Reserve STB 24 STB 24 STB 25 GND 25 GND 25 GND Pt-100 TERMINALS Rear Panel Pt-100 Pin Description 1 2 Sens + 3 4 Excitation - 5 Sens - 6 7 8 Excitation + TC Select BIT Pin 21 22 23 LINEAR 0 0 0 B 1 0 0 J 0 1 0 K 1 1 0 N 0 0 1 R 1 0 1 S 0 1 1 T 1 1 1 Logic Control Log 0 = GND Log 1 = 5 24V

HARDWARE, SELECTION and CALIBRATION The Hardware contains four boards: OC508B Data Outputs BCD OC508J Data Inputs BCD OC508C Calibrator OC508M Main Board OC508B H7 BCD Output Polarity of the INFO Input is not used OC508J H6 H6 1-2 H6 2-3 H6 4-5 BCD Input Polarity INFO (Strobe) Input Strobe HIGH external Strobe LOW external Strobe internal OC508C P3 P2 P1 Calibrator Offset Range Heater

OC508M Main Board H4 1-2 Pt-100 two Terminals, connects S- with I- H5 1-2 Pt-100 two Terminals, connects S+ with I+ H1 1-2 Input 100mV (factory setting) H1 2-3 Input 1V / 10V H2 1-2 Input 20mA H2 2-3 Input 100mV, 1V, 10V (factory setting) H3 1-2 GND for S- (factory setting)

HTEST and CALIBRATION The Submenu permits calibration of the input parameters, checking of the ADC conversion and testing of the outputs. The entry into the Submenu is possible when the key is pressed during the instrument is switched-on. Keep the key pressed until the display changes into the calibration mode (around 20 seconds) and shows CALIBRATION OC508. Key Display RESIST 100.0 TEMP 0.0 C Connect 100.00 Ohm resistor to the Pt-100 input. Set the value at the display to 100.0 with. The temperature shows 0.0 C. Remark: Press the key ONCE to increase the value. Press it twice to decay the value. ADC LOW 1.2298 RESULT 0.000mV Apply 0mV to the signal input. Press the key until EE STORE LOW will be displayed. Zero Point has been calibrated. ADC HIGH 1.6407 RESIST 100.000mV Apply 100mV to the signal input. Press the key until EE STORE HIGH will be displayed. Full Range has been calibrated. BCD-IN LEFT POSITION BCD 1.6407 combination at the input connector will be converted into mv TEST INPUT 0.000mV signal and displayed. BCD 1 MEDIUM POSITION With 1.6407 are the mv selected and converted into BCD code. They TEST OUT 0.000mV are available at the output terminals. BCD 2 RIGHT POSITION With 1.6407 is the temperature selected and converted into BCD code. TEST OUT 0.0 C They are available at the output terminals. DAC HORIZ. POSITION With 1.6407 are the mv selected in a range 0 65.535mV. They are TEST OUT 0.000mV available at the output connector. Calibration 0mV and 65,535mV can be performed with P2 and P3 on the board OC508C.

PC Program for Windows Setting Menu of Calibrator OC508 Calibrator OC508 connect with USB cable to the PC. Select the Data Port INPUT DATA PORT USB and the speed DAUD RATE for e.g. 57600 BD. Program OC508W installation and Start A simple program OC508W for controlling the calibrator OC508 from a PC is part of the delivery. After installation open the program. The window shows two fields: Output and Input. Click at COM and further to Setup. The green light shows the connection to a free Port. The COM is selected automatically. Mark the field T/C Set and select the Output and Input types. Use Send to select the required Input and Output Type, e.g. Voltage. Enter the required Output value, e.g. 12.345mV. The value 12.345mV is transferred to OC508. The LCD Display shows OUT: 12.345mV The external signal at the input of OC508 e.g. 41.363mV is shown when the Read key is activated. The key Stop stops the Input reading. The Temperature measured with external Pt-100 is shown below the input value.