OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

Similar documents
INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

Ocenco Incorporated. M-20 Self Contained Self Rescuer Instruction Manual

OCENCO M-20.2 Self-Contained Self-Rescuer Emergency Escape Breathing Device

Instructor s Manual for M-20.2 EEBD & M-20.2T Training Model

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

MSA AUER SSR 90 [K60]

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

Fire Escape Hood OPERATION AND INSTRUCTIONS

Care and Maintenance of the Ocenco EBA 6.5 Self-Contained Self-Rescuer

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

APPLICATION & LIMITATIONS:

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

Phalanx Alpha Phalanx Beta and Ultra Elite

Respiratory Protection

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

A. Evaluation of the written program

UltraFilter. respirator. with Ultravue or Ultra Elite Facepiece. instructions for use and care

BioPak 240 Revolution

Model XSMKIT. Operations and Instructions WARNING

TABLE OF CONTENTS PART 2 - CONFINED SPACES

SecureLift Lifting System Use Guide Nemisys

Checklist for care of Respirators

Purge Star & Ring Purge Systems

Rev. B. Operating Instructions

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Respiratory Protection Self-Inspection Checklist

Respiratory Protection Self Inspection Checklist

"RESPIRATORY PROTECTION AND SAFETY"

Care and Maintenance of the Draeger OXY K Plus Self-Contained Self-Rescuer

Texas Department of Insurance. Respiratory Protection. Provided by. Workers Health & Safety HS01-027B (1-06)

Respiratory Protection for Producers

60 Minutes Self Contained Self Rescuer. Donning Procedures for Person-Wearable Self Contained Self Rescuer

BioPak 240 Revolution

Self-Rescue Equipment and Skill Development for Mine Escape

CS150 CAP STAPLER OWNER S MANUAL

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

Breathing apparatus. Compulsory Specification for. Published by Government Notice No. R. 370 (Government Gazette 25040) of 20 March 2003

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

Material Handling and Storage of compressed gases and Air equipment

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

CHAPTER 26 WELDING AND CUTTING

HUBEN K1 Pre-charged Pneumatic Air Rifle Owner s Manual

Australian/New Zealand Standard

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

BCF WORK INSTRUCTION Respirator Inspection/Cleaning/Maintenance/Repair and Storage

Respiratory Protective Equipment

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

BREATHE SAFELY: The Proper Use of Respiratory Protection

Respiratory Protection

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by

STATE OF FLORIDA DEPARTMENT OF MILITARY AFFAIRS Office of the Adjutant General St. Francis Barracks, P.O. Box 1008 St. Augustine, Florida

ALERT SERVICE LETTER

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

Product Information News

Australian/New Zealand Standard

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

EMERGENCY BREATHING Military, Commercial & Corporate

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard


LIGHTWEIGHT ABRASIVE BLASTING HELMET INSTRUCTION MANUAL

PERSONAL AIR BREATHING UNIT

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

r (bar) Air Volume(L) Approval Service Life TPED 15

Rapid Survival System

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

Confined Spaces. 1. Definition Permit/Non-Permit

low maintenance respirator

RESPIRATORY PROTECTION PROGRAM

RESPIRATORY PROTECTION PROCEDURE

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Respiratory Protection. Program

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

This program shall contain, as a minimum, the following components:

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

PURPOSE OF THE POLICY

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Compressed Gases Safety Program

Safe Work Instructions For Oxygen Acetylene Equipment

Operation manual. K-S30 Chemical Oxygen Self-rescuer. Version No.: rev.01. Issue date:

Working in Gas Hazard Areas

NIOSH - CAUTIONS AND LIMITATIONS 3 INTRODUCTION 4 RESPIRATORY COMPONENT CONCEPT 5 !WARNINGS! 6 RESPIRATOR OPERATION 8

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

DBML-60/80 Squeeze Tool

Personnel Protective Equipment

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

4-in-1 Professional Inflator Kit

MMR Air Mask With. with Quick-Connect Hose

Particulate Respirator N95

Compressed Gases and Cryogens

Transcription:

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD) INSTRUCTION MANUAL - MINING Manual No: N24056 Revision A, ECN 3577 Date: September 21, 2015 OCENCO, Incorporated 10225 82nd Avenue Pleasant Prairie, WI 53158 USA Page 1 of 13

Section Page WARNINGS AND CAUTIONS 3 1. CLASSIFICATION OF THE M-20.3 EEBD 4 2. METHOD OF OPERATION 4 3. DONNING PROCEDURE 5 4. COMPONENTS 6 5. SPECIFICATIONS 8 6. SERVICE LIFE 8 7. DURATION 9 8. HOW TO INSPECT THE M-20.3 EEBD 9 9. HOW TO CARE FOR THE M-20.3 EEBD 10 10. WHEN TO USE THE M-20.3 EEBD 11 11. DISPOSAL 11 12. REGISTRATION 11 Page 2 of 13

WARNINGS AND CAUTIONS Warnings 1) Wearers must be fully trained in the use and care of the M-20.3 EEBD. 2) All warnings must be strictly adhered to; failure to do so could result in injury and/or death. 3) The M-20.3 EEBD must not be used for purposes other than those outlined in this manual. 4) The M-20.3 EEBD is not to be used underwater. Cautions 1) The M-20.3 EEBD must be regularly inspected to ensure operational readiness. 2) If the M-20.3 EEBD fails any of the inspections, remove the unit from service immediately. 3) Remove the unit from service if the tamper ball is missing. 4) The flow of oxygen will begin automatically when the unit is removed from its base. Cautions and Limitations 1) Failure to properly use and maintain this product could result in injury or death. 2) All approved respirators shall be selected, fitted, used and maintained in accordance with applicable regulations. 3) Never substitute, modify, add or omit parts. 4) Refer to the user instructions and/or maintenance manuals for information on the use and maintenance of this respirator. 5) Special or critical user instructions and/or specific use limitations apply. Refer to instruction manual before donning. Page 3 of 13

SECTION 1 CLASSIFICATION OF THE M-20.3 EEBD The Ocenco M-20.3 is a belt-worn or stored, Capacity 1, compressed-oxygen, Closed Circuit Escape Respirator (CCER), Emergency Escape Breathing Device (EEBD). The M-20.3 EEBD instantly provides breathable air, independent of the surrounding atmosphere, to a person escaping from toxic gas or oxygen deficiency. SECTION 2 METHOD OF OPERATION Oxygen automatically and continuously flows from the cylinder to the breathing bag when the unit is pulled from the base. During inhalation, whenever the bag flattens, the oxygen regulator increases the oxygen flow into the breathing bag. During inhalation, oxygen passes from the breathing bag through the scrubber and into the mouthpiece. During exhalation, carbon dioxide laden air is exhaled through the scrubber and then into the breathing bag. During inhalation and exhalation, carbon dioxide is absorbed by the carbon dioxide scrubber. Occasionally, during low work rates, the oxygen regulator supplies more oxygen than the user can consume. When this occurs, the excess gas automatically vents through the relief valve. The starting of the oxygen flow, the increased flow rate during high work rates, and the occasional venting of gas through the relief valve, all occur automatically: the user needs only to breathe. 2 3 1 4 Constant Flow of Oxygen Demand Flow of Oxygen Inhalation Exhalation Relief Valve Exhaust 5 Page 4 of 13

SECTION 3 DONNING PROCEDURE The following are the donning steps for the M-20.3 EEBD after it is removed from its storage container or carry case. These six steps must be practiced numerous times until they become second nature. 1. LIFT YELLOW 4. FIT YELLOW LEVER AND REMOVE COVER NOSE CLIP 2. REMOVE UNIT BY 5. PURGE CONTENTS OF BAG, INHALE PULLING YELLOW NECK STRAP UPWARDS THROUGH MOUTH AND ESCAPE 3. INSERT YELLOW 6. PUT GOGGLES ON AS NEEDED MOUTHPIECE To purge contents of the bag, exhale into the mouthpiece, hold breath and deflate bag by pressing on bag, then inhale through the mouthpiece, and breathe normally. Gas will vent through the relief valve. Do not remove the mouthpiece or the nose clip during the purge. Do not attempt to manually activate the oxygen regulator as this may result in a shorter duration. To fit the neck strap, simply place the neck strap over the head and pull upward on the o-ring to shorten the neck strap. To fit the goggles, pull the goggles over the head. After donning the goggles, prescription eyeglasses can be donned by guiding the eyeglass temples through the channels provided. CAUTION: The flow of oxygen will begin automatically when the unit is removed from the base. Page 5 of 13

SECTION 4 COMPONENTS Please refer to the illustration of components on next page: 1. Nose Clip: the yellow nose clip is attached to the mouthpiece and is used to close the nasal passage during use of the EEBD. 2. Mouthpiece: the yellow mouthpiece is placed in the mouth such that the flange seals between the lips and gums. The bits should be between the upper and lower teeth. Gently bite on the bits. 3. Neck Strap: the yellow neck strap is to be placed over the head for support and can be adjusted for fit. 4. Oxygen Cylinder: the stainless steel cylinder holds 100% medical grade oxygen. The cylinder is exempt from DOT approval due to its small internal volume. 5. Oxygen Regulator: starts the flow of oxygen and increases the oxygen flow during high work rates. 6. Activation Cable: the stainless steel activation cable is attached to the oxygen regulator and permanently attached to the inside of the base. 7. Gauge: indicates the amount of oxygen in the cylinder. The green zone indicates the M-20.3 EEBD is ready for use. The red zone indicates the cylinder is low on oxygen and should be removed from service. 8. Scrubber: a chamber that removes carbon dioxide from the exhaled air. 9. Breathing Bag: air reservoir that receives oxygen from the regulator and exhaled air from the user. 10. Relief Valve: a one way valve that automatically allows excess air in the breathing bag to vent. 11. Yellow Latch Lever: the yellow latch lever is lifted upwards to open the M-20.3 EEBD. Only lift Latch during emergency use. 12. Cover: the clear cover has an integral yellow tab, that when lifted, releases any possible vacuum which may have developed due to change in atmospheric pressure. 13. Base: the clear base allows the user to visually inspect the scrubber bed integrity and read the pressure gauge. 14. S-Hook: the metal hook that receives the cover latch on the belt side. 15. Goggles: provide eye protection from impact, smoke and chemical vapor. The goggles should be pulled up over the head and secured only after inserting the mouthpiece and applying the nose clips. Prescription eyeglasses can be worn over the goggles if necessary. 16. Tamper Indicating Ball: the presence of a stainless steel ball bearing located in the center of the yellow lever assures that the unit has not been opened. Unit must be removed from service if the Tamper Ball is missing. 17. Information Label: contains the following information: MFG Date: XX/XX Life Date: XX/XX Serial No.: X123456 Last Serviced: XX/XX the date of manufacture as month/year the end of service life date as month/year the traceable serial number of the M-20.3 EEBD the date of last serviced as month/year Page 6 of 13

Page 7 of 13

SECTION 5 SPECIFICATIONS Capacity 20 liters of oxygen Capacity 1 rated at NIOSH 24 liters actual Dimensions M-20.3 EEBD 7.6 x 18.5 x 16.8 cm ( 3.0 x 7.3 x 6.6 in) Weight 946 grams, breathing apparatus only (2.1 lb.) 1406 grams, with case (3.1 lb.) Operating Environment Approved for operating temperatures between 21 F (-6 C) and 110 F (43 C), relative humidity 95% and pressure between 0.8 and 1.2 atmospheres. SECTION 6 SERVICE LIFE Service Life: The M-20.3 may remain in service for fifteen years from the date of manufacture, provided the conditions of use are observed. The M-20.3 must be either stored or belt-worn, according to the conditions of use, throughout its service life. The M-20.3 may be deployed in the belt-worn configuration for 5 continuous years (10,400 hrs) during its 15-year service life. The 5-year belt-worn period begins when the M-20.3 is first deployed, for any length of time in the belt-worn configuration, and ends 5 years from the date of this deployment. After the M-20.3 has been deployed in the belt-worn configuration for 5 continuous years, it must be returned to Ocenco Incorporated to be refurbished, after which it may be re-deployed in the belt-worn configuration for 5 years or deployed in the stored configuration. After the M-20.3 has been deployed as a stored unit for 10 continuous years, it must be returned to Ocenco Incorporated to be refurbished, after which it may be re-deployed in the stored configuration or deployed in the belt-worn configuration for the remainder of its 15 year service life. Conditions of Use: (1) The visual inspections described in this manual must be performed. (2) Proper care described in this manual must be performed. (3) When stored, the M-20.3 EEBD must be contained in an Ocenco approved container and securely fastened to a wall or other substantial structure. Devices stored on vehicles must be secured against movement in a fully enclosed metal container. (4) When belt-worn, the M-20.3 EEBD must be contained in an Ocenco approved carry case. (5) At all times, the M-20.3 EEBD must be contained in an Ocenco/NIOSH approved carry case as called out on the M-20.3 Main Assembly drawing, N24000. Page 8 of 13

SECTION 7 DURATION Five factors affect the duration of the M-20.3 EEBD: 1. The amount of work required to escape affects the duration. Low ceilings, steep inclines or ladders, and irregular floors increase the work required to escape. Less work results in greater duration. 2. The physical condition or "fitness" of the user affects the duration. A high heart rate, age and high percent of body fat decrease the fitness of the subject. The more fit the user, the greater the duration. 3. Regardless of the "fitness" of the user, the amount of oxygen required is proportional to the user s weight. The less the user weighs, the greater the duration. 4. The user's breathing rate affects the duration. The rate can be increased by excitement and fear. The lower the breathing rate, the greater the duration. 5. The degree of training and familiarity can affect the duration. The more training and experience the subject has with the M-20.3 EEBD, the more his breathing will be calm and controlled. If a subject is familiar with a particular escape-way it may improve the mechanics of his escape. The greater the training and familiarity, the greater the duration. SECTION 8 HOW TO INSPECT THE M-20.3 EEBD The inspections for the M-20.3 EEBD are visual. DO NOT lift the yellow latch or open the clear case to inspect the M-20.3 EEBD. The inspections described below shall be performed on each M-20.3 EEBD upon deployment. Subsequently, if the M-20.3 EEBD is belt-worn, the inspection shall be performed at the beginning of each work shift that the device is worn. If stored, the following visual inspections should be conducted every 90 days: 1. Presence of Tamper Indicating Ball on the latch lever. Tamper Indicating Ball Yellow Latch Lever ONLY lift for emergency escape use. WARNING: DO NOT use unit if Tamper Indicating Ball is missing or Latch has been opened. Remove unit immediately from service if the unit has been tampered with or if Tamper Indicating Ball is missing. Lifting Yellow Latch Lever voids the warranty. 2. Read the Pressure Gauge: The tip of the needle on the gauge is normally in the green zone. If the needle is in the red or on the white zero pressure mark, remove the M-20.3 EEBD from service immediately. If the view of the gauge is obstructed, the M-20.3 EEBD must be removed from service. If the surrounding air temperature is above 120 F (49 C) and the needle is above the green zone, the unit can remain in service. The needle should return to the green zone when unit is removed from the high temperature. Page 9 of 13

3. Visually inspect the apparatus for indications of high force impacts. Indications of high force impacts are listed below. If any of these signs are present the M-20.3 EEBD must be removed from service: Case cracked, burned, deformed or excessively worn. Excessive gap between the Cover and Base. Damaged Latch or Cover Band. Dirt or debris visible through case. Moisture visible through case. Sorbent dust in breathing bag visible through case. 4. Ensure that the M-20.3 EEBD has not exceeded the life date printed on the information label. Ensure belt-worn period (5 consecutive years) has not expired. WARNING: If the M-20.3 EEBD fails any of the above inspection or if at any time during its life the pressure gauge is out of the green zone or the indications of force impacts are observed, the unit should be removed immediately from service. IN-SERVICE TESTING & TRAINING In-service M-20.3 CCERs selected for training or testing purposes must meet all of the visual inspection criteria listed above, and shall have been maintained in accordance with the stated conditions of use. Devices that fail visual inspection, are deployed outside the conditions of use, or are past their service life date, must be removed from service and shall not be used for training or testing purposes. Further, the M- 20.3 CCER donning instructions must be followed without omissions or additions to the stated procedure. Failure to follow the proper donning instructions may result in reduced respiratory protection. SECTION 9 HOW TO CARE FOR THE M-20.3 EEBD Your life may depend on the care you give your M-20.3 EEBD. Avoid the most common abuses: 1. If the M-20.3 EEBD is accidentally opened, do not close it. Remove from service. 2. Do not drop the M-20.3 EEBD, particularly when removing it from its carrycase. 3. Do not clean the M-20.3 EEBD with anything other than a soft brush (only outside case) 4. Do not immerse the M-20.3 EEBD in water 5. Do not sit on the M-20.3 EEBD. 6. Do not drag the M-20.3 EEBD on the ground. 7. Do not put tape or stickers on the M-20.3 EEBD that would impede its opening or the reading of the gauge. Page 10 of 13

SECTION 10 WHEN TO USE THE M-20.3 EEBD The M-20.3 EEBD should be used immediately at the first indication of a fire or explosion, even if smoke is not visible. Carbon monoxide is odorless and colorless. You could breathe a fatal amount of carbon monoxide before smoke is present. If you suspect an oxygen deficient atmosphere, put on the M-20.3 EEBD. Some of the possible indications of an emergency are: 1. Sight of smoke 2. Smell of smoke 3. Sight of fire 4. Fire or toxic gas alarm 5. Sudden increase of air temperature 6. Sound of an explosion 7. Vibrations of an explosion 8. Interruption of air flow 9. Someone around you has difficulty breathing or passes out In the event of an emergency, always don your M-20.3 EEBD before attempting to escape or help others. SECTION 11 DISPOSAL Safe disposal is necessary after the M-20.3 EEBD has been used, fails inspection, or has exceeded the fifteen year service life. Ocenco EEBDs must be disposed of in accordance with hazardous material disposal regulations. Please contact Ocenco Inc. for disposal options. SECTION 12 REGISTRATION The National Institute for Occupational Safety and Health (NIOSH) requests, but does not require, that purchasers of this respirator register each unit with NIOSH. Registration will enable NIOSH, which approved this model of respirator, to attempt to notify you if a problem is discovered that might affect the safety or performance of this respirator. Registration will also assist NIOSH in locating deployed units to periodically evaluate whether this respirator model is remaining effective under field conditions of storage and use. Page 11 of 13

Ocenco Incorporated 10225 82 nd Ave. Pleasant Prairie, WI, 53158 USA (262) 947-9000 Model M-20.3 Cap 1-M-20L CLOSED CIRCUIT, ESCAPE, RESPIRATOR SELF-CONTAINED BREATHING APPARATUS THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS: Model Name M-20.3 - Mining TC - Protection 1 Part Number 940302 Cautions and Limitations 2 13G-0004 SC/ESC/CAP 1-M-20L X JMNOS 1. PROTECTION SC Self-contained ESC Escape CAP Capacity 2. CAUTIONS AND LIMITATIONS J - Failure to properly use and maintain this product could result in injury or death. M - All approved respirators shall be selected, fitted, used and maintained in accordance with MSHA, OSHA, and other applicable regulations. N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O - Refer to the User s Instructions and/or maintenance manuals for information on the use and maintenance of this respirator. S - Special or critical users instructions and/or specific use limitations apply. Refer to Users Instructions manual before donning. Page 12 of 13