Hallowell EMC Vacuum / Scavenging Interface

Similar documents
Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Draeger Fabius GS Pre-Use Check

Hallowell EMC Anesthesia WorkStation Operating Manual

Anesthesia Machine Intro

Anes Machine Use and Pre-use Check - CA1 focus

Flow meter. bellow vaporizer. APL valve. Scavenging system

Effective 2/1/17. SC1 Service Call PER Visit $76.00

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

Keeping anaesthetic pollution to minimum in theatre environment

MicroVent 1 Dual Mode Veterinary Ventilator IPPV / HFOV

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Recommendations on Checking Anaesthesia Delivery Systems

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

HORIZONTAL BLADDER TANK

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Landmark. Veterinary Anesthesia Systems. Operator s Manual P/N

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Breathing Systems. Professor Khalid Bashir

VERTICAL BLADDER TANK

Aespire 7100 Essential performance Compact design

AUTOVENT 4000 VENTILATOR

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Air Eliminators and Combination Air Eliminators Strainers

Operation and Maintenance of the EPV200 Portable Ventilator

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

APUS Anesthesia Machines

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

User Guide and Operating Manual

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

VACUUM REGULATORS CONTENTS

Breathing Circuits. Product training

Model PSI Compressor with 3-Gallon Air Tank 12VDC

M5400 Operators Manual

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

The centerpiece of a comprehensive anaesthesia workstation

Medical Instruments in the Developing World

User Manual. Model 3930 Vacuum Assisted Venous Drainage Controller w/ WAGD Suction Flowmeter

2011 Equipment Catalog

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

Anesthesia. Midmark Animal Health Products

URN (UNIVERSAL RODENT NOSE CONE) (17mm diameter) Figure 1

Glove Box Installation Manual

S/5 Aespire. Quick Reference Guide

KOALA. Disposable Adult Anaesthetic Circuits for Low Flow Anaesthesia KO.S5.22MM. Adult Anaesthetic Circuits. Medical Pty Ltd

1020 Industrial Drive, Orlinda, TN fax

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

OPERATING MANUAL LO-CROSS-FLOW CF M

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

OWNER S TECHNICAL MANUAL

Pneumatic Conveying Principles BSH&E SEMINAR

ACCU-PULSE Installation and Operation Instructions

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

GREIG FILTERS, INC. OPERATION MANUAL

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

Checking a Breathing System

Medical Gas Control Panel

STREAMLINE SHOP SERIES MODEL 30040V OPERATION & PARTS MANUAL

(Delivery System) Pocket Guide. Series 3 software

Installation Instructions for NP100 Series Nitrogen Control Panels

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

2 Sentry MCL Installation, Operation & Maintenance

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

A9600 Anesthesia Workstation. Your healthcare, we care.

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

Anesthesiology Research and Scholarship. Follow this and additional works at:

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

Flowmeters & Accessories Guide

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

MB-SP Series Solvent Purification System

The SAV04 Small Animal Ventilator. Contents Page

INSTRUCTION MANUAL. (Variante 2 / System 2) Surgery table standard (Variante 1 / System 1)

Your patients, our primary focus. Siesta i Whispa anesthesia machine

DESCRIPTION AND OPERATION OXYGEN SYSTEM OXYGEN SYSTEM

State-of-the-art anesthesia technology

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Standard Specification for Anesthetic Gas Scavenging Systems Transfer and Receiving Systems 1

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

ABRASIVE REGULATOR II

VAPOMATIC ANESTHETIC VAPORIZER

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Rev. B. Operating Instructions

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

ABRASIVE REGULATOR II

Transcription:

Hallowell EMC Vacuum / Scavenging Interface For use in veterinary medical applications only. Operating Manual and Scavenging Primer with Receiving Information, Installation and Maintenance Instructions Thank you for your order. I believe you will find this Veterinary Vacuum/Scavenging Interface by far, more reliable, easier to install, and simpler to use than any other such device on the market. Best regards, Stetson Hallowell

Hallowell EMC Vacuum/Scavenging Interface Available Mounting Options 000A5631 Round Pole Mount 000A5632 Square Post Mount 000A5633 Ceiling Mount 000A5634 Wall Outlet Mount 000A5762 Wall Mount Features of this HEMC interface: Two scavenging tube inlet ports (1) that accepts either 19 mm or 22 mm tubing. Optionally the interface can be supplied with three or four inlet ports. An integral scavenging backup system in the form of a charcoal canister (2) that scavenges the anesthetics, other than N2O, from the waste gas in the event of suction system disconnect or failure. This back up mode also facilitates transport to other areas of the hospital or can be used where vacuum is not available. There are no inlet, outlet or overpressure relief valves to foul, fail or need servicing. The scavenging flow rate can be precisely set (3) between 1 and 10 liters per minute and is easily verifiable at any time at a glance from most any angle. It is configurable such that it will plug into a wall outlet, hang from a ceiling drop, mount to a square post or pole mount on most any size round pole. Durable life lasting stainless steel construction with stainless steel hardware provides MRI compatible as well. DOCA3136B VacScav manual 2 of 10

Receiving: The packing slip you received with this interface lists the part number for this interface. You have received only ONE part completely assembled that is made up of all the additional parts needed to customize its gas connections and mounting options to your needs as discussed when you have placed your order, you received TWO parts only if the hose assembly was required to be separate. Installation: Wall Mount, Wall Outlet Mount, and Ceiling Drop Mount units: Your interface should be supplied with the type of quick connect (DISS, Ohio, Chemetron, Schrader or Puritan style) fitting you requested at the time your order was taken. The ceiling drop interfaces will have an additional 90 elbow fitting at the top of the flowmeter facilitating the vertical connection to the drop. Simply plug the interface into either the wall outlet or the ceiling drop. 1. Connect one 19mm or 22mm tube from each device you wish to scavenge onto the inlet ports (1) on the top of the interface. If an inlet port is not to be used it MUST BE occluded, a red cap plug is included for this purpose. 2. Be sure the appropriate size reservoir bag is securely attached to the bottom 22 mm connector (4) to the left of the flowmeter. A 2-liter evacuation purple, the color standard, bag is included and is appropriate for most applications. One liter and one-half liter bags are also available. 3. Weigh the charcoal canister. Mark the weight in grams on its label along with the date of installation. 4. Attach the canister to the 15 mm port (2) on the bottom side and to the right of the flowmeter. WARNING: This vacuum/scavenging interface WILL NOT work properly without the charcoal canister, even if the vacuum system is functioning. DOCA3136B VacScav manual 3 of 10

Installation: cont. Pole Mount and Square Post Mount units: 1. Your interface should have been shipped with a pole mount plate and clamps to accommodate the size pole or with a square post mount bracket and thumbscrews you told us you would be mounting the interface on. Place the interface in the desired position on the pole and close the two clamps or the square post and secure the bracket with thumbscrews. TIGHTEN SECURELY AS POSSIBLE. 2. Follow steps 1 through 4 above. 3. Pole/Square Post mount interfaces may either have an attached hose or may have a separate hose that needs to be connected to the back of the interface s flowmeter via the quick connect or DISS fitting you requested. Replaceable Parts List: Part # Description 200A3046 Cap, tapered for 19mm tube 240A1466A Flowmeter, Scavenger flow 1-10 lpm 200A3510 Bag, 2 Liter EVAC Purple Reservoir 240A1450 f/air Canister DOCA3136B Operating Manual, Vac/Scav Interface DOCA4948 HEMC Master Operating Manual CD 000A5642 Custom Hose Assembly Scavenging Primer: DOCA3136B VacScav manual 4 of 10

It has been determined, and regulations require, that waste anesthetic gases must be collected and removed from the premises for health reasons, thus the existence of this device. Scavenging systems can be classified into two major categories, passive and active systems. A passive system essentially is no more than a hose that directs the flow of waste gasses to a location where it can be safely vented, generally outside a building or into a non-recirculating ventilation system. Systems classified as active can be further grouped into blower in a box (low vacuum) systems or central vacuum systems. Blower-in-a-box systems are just that, they have a blower in a box that blows the gas out of the building. Piping is connected from each device to be scavenged into the box. The negative pressure in the piping and box is in the order of magnitude of -2 mmhg. This limits the number and length of drops, connections to machines, which these systems can handle. As will be seen below even this low vacuum pressure will require the use of a scavenging interface of some type. Central vacuum systems generate a much greater negative pressures, around 450 mmhg and can accommodate many drops and long piping runs. These systems can also be used for surgical and tracheal suctioning. It is for the latter classification of scavenging systems, the central vacuum system, that this interface was designed. Since in practice breathing systems are generally operated in either an open or semi-open mode they all must have some way to allow the excess fresh gas introduced into the systems to be vented. Otherwise, the pressure within the system, which includes the patient, would continue to increase until something ruptured. That something would probably be the lungs of your patient. Therefore, every breathing system is equipped with some form of automatic pressure limiting (APL) valve also called a pop-off valve the purpose of which is to vent just enough gas from within the system such that the pressure within does not exceed the desired safe level. The pressure at which an APL valve vents the gases is generally adjustable. Actually however APL valves are most often set either fully open during spontaneous breathing of the patient or fully closed in order to bag or mechanically ventilate the patient. Fully open in the case of APL valves does not mean that there is absolutely no opening pressure or resistance to flow. If this were the case there would effectively be a big hole in the breathing system, its contents would be free to flow out and the breathing bag would not hold enough volume to accommodate the patient s next breath. Thus every properly operating APL valve has some finite, albeit very low, opening pressure. Ideally this pressure is enough only to keep the breathing bag full and no more. Most APL valves do not permit gas to flow through them until the pressure in the system increases to somewhere between 0.5 and 2 cmh2o, that is then called its opening pressure. This is not much pressure when you consider that 1 psi is equal to about 70 cmh2o pressure, which for the discussion below is also about equal to 50 mmhg. Doing the math you can see that 1 cmh2o is equivalent to 0.014 psi, not much! Vacuum, suction and or EVAC (evacuation) systems are available in many hospitals today for other purposes such as surgical or tracheal suctioning but the same system can also be used for handling such pollutants as are discharged from anesthesia machines. The negative pressure in these systems however is in the neighborhood of -450 mmhg; this converts to about -630 cmh2o or 6 psi. Scavenging Primer: cont. DOCA3136B VacScav manual 5 of 10

It can be seen that if you were to connect a negative 630 cmh2o vacuum source up to an APL valve with an opening pressure of 1 cmh2o that in most cases, depending on the design of the valve, the valve would be sucked open and it would not take long for the gas in your breathing system, breathing bag and patients lungs to be completely evacuated. Some APL valves are constructed in a manner that will cause them to get sucked closed if too great of a negative pressure is applied to them. This will prevent the breathing system from being drained dry but this also prevents the excess gas from escaping therefore the pressure will continue to rise in the system a rate proportional to the fresh gas flow rate. The problem is similar to what you have seen when someone forgets to open the pop-off valve after bagging the patient a couple of times. The breathing bag eventually becomes over distended and the pressure within causes varying amounts of lung damage until the problem is noticed and the pressure relieved. In either case this is not good for the patient, and there in lies the need for this vacuum/scavenging interface. This is a device that couples two incompatible systems so that they will work with each other. A properly functioning scavenger interface, as we see above, should allow for the removal of all gases that exit an APL valve without interfering with its delicate operation. The scavenging system cannot apply any negative pressure to the device it is scavenging greater than the opening pressure of that device s APL valve. Most scavenging interfaces provide a needle valve to regulate the amount of suction that is applied to the system but no other interface quantify the amount of scavenging flow nor do any permit fine enough adjustment to make this an easy setting. The Hallowell EMC Vacuum/Scavenging Interface has been designed in such a way that even at high scavenging flows the negative pressure applied to the devices being scavenged never comes close to their opening pressures. See the graph on the next page. DOCA3136B VacScav manual 6 of 10

Pressure (cmh2o) Interface Operation With the vacuum system running and connected adjust the flowmeter to obtain the desired scavenging flow rate. If you are not sure what flow rate you should be using start with 5 lpm. The idea is to have the scavenging flow as low as possible so as not to over tax the vacuum system, but high enough to keep up with the average discharge from the devices you are scavenging. The reservoir bag exists to accommodate short periods of high discharge such as when you empty the breathing bag or press the flush button (something I highly recommend avoiding with any small animal patient connected). 2.0 1.8 1.6 1.4 1.2 Typical APL/Pop-off valve opening pressures Hallowell EMC 06-Dec-01 by: WSH Pressure drop across a typical f/air charcoal canister 1.0 0.8 0.6 0.4 100% margin 0.24 cmh2o 0.5 cmh2o 0.2 0 2 4 6 8 10 12 14 16 Flow (lpm) DOCA3136B VacScav manual 7 of 10

Interface Operation cont. Normally during low or moderate flow anesthesia the fresh gas flow rate is set at 2 lpm or much lower. The patient will uptake a portion of that flow and the balance is popped off to the scavenger. If you run your anesthesia system with 2 lpm fresh gas flow a scavenging flow of 5 lpm would end up drawing about 3 lpm of room air as well as the average waste gas discharged from the APL valve. If you are using higher fresh gas flow rates or are frequently emptying the breathing bag and flushing or adjusting the O2 flowmeter to compensate you may need to set the scavenging flow rate higher. With lower flows it could certainly be set lower. How appropriate the scavenging flow setting is for the way you operate your anesthesia system can easily be judged by observing the size of the reservoir bag frequently through a few cases. Decrease the flow rate till you see that over the long run the bag never seems to empty completely. Then increase the flow by 50% for a comfortable margin. After you have done this you will find that you will not have to change the setting again given that you continue to operate your anesthesia system in the same manner and that your vacuum level remains the same. Maintenance: This interface is made of solid brass and is chrome plated for durability and easy cleaning. Simply wipe it clean with a damp cloth when required, Get no alcohol on the plastic flowmeter. The charcoal canister serves a dual purpose in this system. The system will not function properly without the charcoal canister. Primarily it provides the slight pressure drop required for trouble free scavenging and filters dust and hair from incoming room air. Far less frequently, when made necessary by a suction system failure or disconnect, flow is revered through the canister and it absorbs the volatile anesthetics (not N2O) from the waste gases as they are discharged into the room preventing eventual over distention of the patients lungs. The interface can also be used in this latter back up mode during transport or for cases where vacuum is unavailable. The amount of dust accumulation at the bottom of the canister and its reserve capacity to absorb more anesthetic must be checked periodically to insure proper performance of the system. Weighing the canister periodically and comparing it to what the canister weighed when it was placed in service (See the Receiving section above) best estimates this reserve capacity. The frequency with which you check the canisters weight depends on your usage but should be done soon after any known suction system failure or disconnect or any transport cases. Be sure to clean off as much dust accumulation as possible from the underside of the filter before weighing it. Before the canister gains 50 grams over the weight recorded when it was put into service (its point of exhaustion) it should be discarded and replaced as recommended by the manufacturer. It is advisable to get into the habit of using the same gram scale to weigh the canisters. Exhausted canisters are to be disposed of as ordinary trash. As always your comments and feedback on our products are always appreciated. I can be contacted at 413-445-4263 or stetson@hallowell.com DOCA3136B VacScav manual 8 of 10

We would appreciate it if you would look into some of our other products including: The Hallowell EMC Model 2002 Pro Series of Veterinary Anesthesia Ventilators with bellows attachments accommodating patients from 2 to 400 lbs. Maintain normocapnia reducing the risks associated to respiratory acidosis and decreased blood ph levels leading to cardiac complications. This is especially important to your obese patients or those undergoing perineal, perianal or PU surgeries due to their positioning. Smooth out rocky anesthesias, free a pair of hands when you really need them. The Hallowell EMC Anesthesia WorkStation (AWS). This new concept is a complete anesthesia machine (less the vaporizer of your choice) for animals from 150 grams to 6 or 7 kg. It is the same size as the model 2000 but incorporates a heated circle rebreathing system for the patients you previously had to put on a non-rebreathing system. Also incorporated is an integral volume ventilator. Should you want to mechanically ventilate the patient just switch the control from STANDBY to VENTILATE. Now available is a 200ml attachment effectively doubling the maximum deliverable tidal volume (TV) and size of the patient it will accommodate. The Hallowell EMC Heated Hard Pads, literally bullet proof (.22 caliber), are a welcome relief from the so frequent hassles of patching or replacing the flexible heating pads. These solid polycarbonate pads will attach to any existing hot water circulating pump you may have with the provided connectors and still permit you to use your old flexible pads when desired. The Hallowell EMC lightweight equine wyes and breathing system tubes. The wyes are light plastic, will accommodate both Drager and Bivona style metal endotracheal tube connectors as well as the Bivona and Cook funnel fit connectors. They are available with gas sampling ports that draw from within the ET tube. We also have an equine bronchial-blocker tube for lung separation applications. The breathing system tubes are also light, clear and easy to clean and dry quickly. DOCA3136B VacScav manual 9 of 10

Name: Date: Self-assessment review quiz: 1. What are the general classifications of scavenging systems? 2. Why is scavenging important? 3. What does APL stand for? 4. What conditions could cause the breathing system bag to be drained by a scavenging system, i.e. what pressures would need to be in what relationship to each other? 5. What should a properly operating scavenging system provide for? 6. What observations could you make that would indicate to you that the scavenging flow is inappropriately set? What would you do to correct it? 6a. That was easy, what else? 7. What two things should be periodically checked to insure continued proper functioning of this interface? When or how often? How is this done? DOCA3136B VacScav manual 10 of 10