3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Similar documents
3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Fast. Efficient. Precise control. 3M Liqui-Cel Membrane Contactors. Dissolved gas control solutions for the beverage industry

A high level of consistency and control.

Adhesion Performance Requirements for Adhesive Backed Light Trim and Foam. Technical Bulletin August, 2016

Tape, Polyester Two Sided Pressure Sensitive. Technical Bulletin August, 2016

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

FLANGED MULTI-PORT BALL VALVES

FLANGED TWO-PIECE BALL VALVES

Pressure Sensitive Adhesive Cellular and Fibrous Materials Automotive Spec Testing. Technical Bulletin August, 2016

Vessel Installation and Operating Manual

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

FLANGED TWO-PIECE BALL VALVES

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

Cylinder Adhesive for Geotextile Seaming

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Cocoa Patio Pond with Lit Spillway

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

NS Cylinder Spray Adhesive - User s Guide

Installation and Operating Manual

FOOSBALL ASSEMBLY, INSTRUCTIONS AND RULES PL

TR5000 THE TOUGHEST TRAINING SYSTEM ON THE PLANET. MODEL NO. STRIKER TRAINER 2L Escalade Sports

Yoke Block Instruction Manual

DT400/436 Tee Connector Installation Instructions

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Cylinder Spray Adhesive - User s Guide

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

COOPER POWER SERIES. QD8 Quik-Drive tap-changer VR or VL reversing switch stationary contact assembly kit number A48 installation instructions

Owner s Manual Tourmaster Storage Cart

SASK-A-POLE OWNERS AND USERS MANUAL

Traditional Basketball Set. Assembly & Installation Instructions

6500 KNIFE GATE VALVES

RADROVER REAR RACK INSTALLATION MANUAL

Pressure Relief Valve Instruction Manual

Type BBS-03, BBS-05, BBS-06, BBS-25

MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Installing Carriers to Cross Bars

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

COMPACT METAL bender 99826

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Remington 700. Disclaimer Limited Warranty Satisfaction Guarantee Installation Instructions

FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Please Do Not Return This Product To The Store!

EasyLife INSTRUCTIONS FOR USE. Respironics Inc Murry Ridge Lane Murrysville, PA USA JDH 3/25/10

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Integrity Testing LifeASSURE BDA020, BGA020 and BNA020 Series Filter Cartridges

BS Series Basket Strainer

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Pressure Injection Cell Operator s Manual

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Cylinder Tilt Saddle Instruction Manual

Yoke Block Instruction Manual

DAI630TB2669 Dead Front Arrester Installation Instruction

Dual Release Walkers 6291 Series. 1 General. 1.1 Symbols WARNING

Stainless Steel 142 mm Filter Holder YY

SOTR Special Operations Tactical Respirator

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

Effective March 2015 Supersedes S August 2002

Circular Sight Windows

MECH-TECH SYSTEMS CCU MODEL FOR GLOCK PISTOLS

ROPV R40 E Series User Manual

2010 Koninklijke Philips Electronics N.V. All rights reserved. INSTRUCTIONS FOR USE

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

TMP. PepperBall User Manual

Rescue Ladder Basic Kit Model: FS-EX243 18ft (5.48m)

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

Read through all the steps first before working on the camera. Make sure you know what to do.

Repair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B

User s Manual. USB Golf Simulator. Contents

Multi-Probe Sampling System User Guide & Manual

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

Invacare Twilight II Nasal Mask

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

3" UC Ultra-Chuck Durable Lightweight Air Inflated Bladder Chuck Operation/Repair Manual. (76.2 mm) DOUBLE E COMPANY, INC.

GREIG FILTERS, INC. OPERATION MANUAL

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

OWNERS MANUAL. Model Shown with optional Primary Mooring Cleats. Portable Mooring System SAFETY OPERATION MAINTENANCE PARTS

STYRIGGER PRODUCT MANUAL

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

OPERATION AND INSTRUCTION MANUAL

Instruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

The P-Rod Double by The Airgun Lab Installation Instructions Revision F 08/01/2016 page 1 of 18

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

MAVERICK FOOSBALL TABLE

MANUAL. Sesame. Thermoplastic Tank Technologies

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Model Sanitary Vent SECTION I

IMPACT RING BIT SYSTEM Care & Maintenance Instructions

COOPER POWER SERIES. 600 Ampere Deadbreak Grounded Standoff Bushing 15 & 25 kv and 35 kv Class Installation Instructions. Bushings MN650045EN

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Transcription:

Membrane Contactors 3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors Assembly and Disassembly Instructions 3M.com/Liqui-Cel

TABLE OF CONTENTS I. Safety and Warning 3 II. Assembly Parts 4 III. Assembly Tools 4 VI. Disassembly Procedure 5 V. Assembly Procedure 7

I. SAFETY INFORMATION Read, understand, and follow all safety information contained in these instructions prior to the use of this 3M Liqui-Cel Membrane Contactor. Retain these instructions for future reference. Intended Use: This Liqui-Cel Membrane Contactor is intended to add to or remove dissolved gases from non-dangerous liquid streams. It is expected that all users be fully trained in the safe operation of membrane contactors. Membrane contactors are intended for installation and operation by qualified installers and operators in accordance with all operating guidelines, installation instructions, and any other industry requirements. Use in any other application may not have been evaluated by 3M and may lead to an unsafe condition. WARNING To reduce the risks associated with explosion: Only use replacement parts supplied by 3M for this product. To reduce the risks associated with crush or impact related injuries: Always ensure the membrane contactor is properly secured. Be sure the membrane contactor cannot tip, roll, fall, slide or make any movement that may cause injury or damage to other system components. No liquid, vacuum or sweep gas should be running through the contactor when changing cartridges or other parts. Membrane contactors should be completely drained of liquid before attempting to service. Care must be taken not to hit or jar (shock) the membrane contactor. NOTICE To reduce the risks associated with lifting or moving: Always consult the product datasheet or operating guide for membrane contactor weights. Use appropriately rated lifting equipment for lifting or moving heavy membrane contactors. Drain liquid from the contactor before moving. Do not move a membrane contactor while it contains liquid. CAUTION To reduce the risks associated with environmental contamination: At the end of useable life, dispose of the membrane contactor or cartridges in accordance with local regulations and laws. The membrane contactor(s) should not be stored where they are exposed to direct sunlight. Membrane contactors should always be stored in sealed bags or shrink wrap material and in the original box or other opaque box. Store dry membrane contactor(s) at temperatures <49 C (120 F) with low to moderate humidity levels (<60% relative humidity). Avoid contact with surfactants/solvents or oxidants (e.g. ozone, chlorine) to prevent wet-out or oxidation of the hydrophobic membrane. To avoid contamination, gloves are recommended when handling the membrane cartridges. Do not use dope or metal connections to connect to plastic connections of the membrane contactor. Failure to follow any instructions in this guide will void any warranty, if any exists. WARNING CAUTION NOTICE EXPLANATION OF SIGNAL WORD CONSEQUENCES Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage. Indicates a potentially hazardous situation, which, if not avoided, could result in minor or moderate injury and/or property damage. Indicates a potentially hazardous situation, which, if not avoided, could result in property damage. EXPLANATION OF SAFETY AND RELATED SYMBOLS Warning: Explosion Warning: Crush or Impact Caution: Lifting or Moving Hazard Caution: Possible Environmental Impact 3

II. ASSEMBLY PARTS A. Outer Viton O-ring (2) O-ring used to seal water side (cartridge/housing seal). B. Center Viton O-ring (4) O-ring used to seal water side (cartridge/center nozzle seal). A B C. Retention Ring (2) 9 mm diameter retention ring for outer O-ring. D. Viton Gasket (2) 4 inch gasket (end cap seal). D C III. ASSEMBLY TOOLS A. Small Insertion Tool Used to support the cartridge during assembly/ disassembly. B B. Large Insertion Tool Used to insert the cartridge and outer O-ring. C. Rubber Mallet Used to tap insertion tool during O-ring assembly. D. O-ring Pick Used to remove the outer (shellside) O-ring during disassembly. A D C 4

IV. DISASSEMBLY PROCEDURE A WARNING To reduce the risks associated with crush or impact related injuries: Always ensure the membrane contactor is properly secured. Be sure the membrane contactor cannot tip, roll, fall, slide or make any movement that may cause injury or damage to other system components. No liquid, vacuum or sweep gas should be running through the contactor when changing cartridges or other parts. Membrane contactors should be completely drained of liquid before attempting to service. Care must be taken not to hit or jar (shock) the membrane contactor. To reduce the risks associated with lifting or moving: Always consult the product datasheet or operating guide for membrane contactor weights. Use appropriately rated lifting equipment for lifting or moving heavy membrane contactors. Drain liquid from the contactor before moving. Do not move a membrane contactor while it contains liquid. CAUTION To reduce the risks associated with environmental contamination: B At the end of useable life, dispose of the membrane contactor or cartridges in accordance with local regulations and laws. NOTICE To avoid contamination, gloves are recommended when handling the membrane cartridges. DISASSEMBLY PROCEDURE STEPS (A) Using a 3/8" socket, remove the end cap clamps. (B) Remove the end caps using a twisting, pulling motion. It may be necessary to lightly tap the gas elbow outward with a rubber mallet to loosen the end cap. (C) Remove the gasket. C (D) Using the O-ring pick, remove the retention ring. D 5

(E) Using the O-ring pick, remove the outer O-ring. Insert the pointed end of the pick into the O-ring and pull outward. E NOTE: The outer O-rings may be damaged during removal and should be discarded DO NOT RE-USE. (F) Place the small insertion tool on a solid flat surface, with the beveled side pointing up. F (G) Flip the contactor over and rest on top of the small insertion tool. G Repeat the previous 3 steps on the other end of the contactor. Once the outer O-ring is removed, the vessel should slide down over the cartridge. The cartridge will be supported by the small insertion tool. (H) Carefully slide the cartridge out of the housing. H NOTE: Be careful not to chip the potted edge of the cartridge. 6

V. ASSEMBLY PROCEDURE A WARNING To reduce the risks associated with explosion: Only use replacement parts supplied by 3M for this product. To reduce the risks associated with crush or impact related injuries: Always ensure the membrane contactor is properly secured. Be sure the membrane contactor cannot tip, roll, fall, slide or make any movement that may cause injury or damage to other system components. Care must be taken not to hit or jar (shock) the membrane contactor. To reduce the risks associated with lifting or moving: Always consult the product datasheet or operating guide for membrane contactor weights. Use appropriately rated lifting equipment for lifting or moving heavy membrane contactors. NOTICE To avoid contamination, gloves are recommended when handling the membrane cartridges. B ASSEMBLY PROCEDURE STEPS (A) Place the small insertion tool on a solid flat surface, with the beveled end pointing down. NOTE: The end with the 1/4" ridge should be pointing up. (B) Rest the housing on the small insertion tool. (C) Carefully insert the cartridge into the housing. C (D) Position an outer O-ring over the potted end. Note that the cartridge will be about 1/4" below the flanged surface of the housing. D 7

(E) Place the large insertion tool over the end of the cartridge and outer O-ring. Be sure the large insertion tool is placed evenly over the O-ring. E Tap lightly around the circumference of the insertion tool until the cartridge and outer O-ring move into the housing. (The small insertion tool will act as a stop.) F (F) Flip the housing over and rest back on the small insertion tool. Note that the cartridge protrudes approximately 1/4" from the flanged surface of the housing. G (G) Place an outer O-ring over the potted end of the cartridge. (H) Place the large insertion tool over the end of the cartridge and outer O-ring. Tap lightly on the insertion tool until the cartridge is centered in the housing. H NOTE: Slightly more tapping force may be required during this procedure. 8

(I) Install a retention ring on one side of the contactor. Tap lightly with the rubber mallet if necessary. I (J) Install a gasket in the grooved end of the housing. J NOTE: Prior to inserting the end cap, check the integrity of the 2 small center O-rings. Replace if damaged or worn. K (K) Install the end cap using a twisting, pressing motion. Press evenly to prevent damage to the center O-ring or to the center tube. If the center O-rings are pinched, or otherwise damaged, they will not seal properly. Continue until the end cap is completely flush with the vessel. L (L) Install the clamps using a 3/8" socket. Repeat the previous 4 steps for both ends of the contactor. Ensure that the gas ports are properly aligned before completely tightening the clamp bolts. For more information, contact us or visit us online at 3M.com/Liqui-Cel. 9

Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed. Product Use: Many factors beyond 3M s control and uniquely within user s knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user s method of application. Warranty, Limited Remedy, and Disclaimer: Unless an additional warranty is specifically stated on the applicable 3M product packaging or product literature, 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE. If the 3M product does not conform to this warranty, then the sole and exclusive remedy is, at 3M s option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 3M and Liqui-Cel are trademarks of 3M Company. All other trademarks are the property of their respective owners. 2017 3M Company. All rights reserved. Separation and Purification Sciences Division 13840 South Lakes Drive Charlotte, North Carolina 28273 USA Phone: +1 980 859 5400 3M Deutschland GmbH Separation and Purification Sciences Division Öhder Straße 28 42289 Wuppertal Germany Phone: +49 202 6099-0 Fax: +49 202 6099-241 LC-1093 Rev. 04/2017 3M.com/Liqui-Cel