Water Temperature Control - Groups of Fixtures

Similar documents
BrainWave Electronic Mixing Valve Installation, Operation and Maintenance (IOM)

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

SonoMeter 30 Energy Meters

ASSE International Product (Seal) Listing Program

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

SINGLE VALVE WITH LOW-FLOW BYPASS

Gas density monitor With integrated transmitter Model GDM-100-TI

B LCTV_v3 4/27/04 10:54 AM Page 1 Series e700

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Technical Information Conducal CLY421

Programmable pressure and temperature transmitters PTM/RS485

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Expert Hydrostatic Level Transmitters

LEAD FREE * Product Specification. Features n. Specifications n. Relay Specification n ! WARNING NOTICE

CALEFFI. Ball zone valves. series /03 GB

Precision pressure sensor Basic version Model CPT6020

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Programmable pressure and temperature transmitters PTM/RS485

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

Presented to the IAPMO Standards Review Committee on March 7, 2016

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pressure independent control valve (PICV) FLOWMATIC

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Solenoid valves VZWF, force pilot operated

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Tightness controls TC 1 3 and TC 4

Pressure Independent Control Series

Pressure Measurement Single-range transmitters for general applications

Pilot valves for pilot operated servo valves

2/2-Way Solenoid Control Valve

Porter Analytical & Industrial Products

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

CALEFFI. LEGIOMIX Electronic mixing valve series 01086/18.2 NA

Rada-Presto TF2020 and TF2020S

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Applications. Features AWWA ULTRASONIC WATER METER

Proportional Pressure-Relief Cartridge Valve, Size 2...4

9700 Transmitter Submersible hydrostatic level transmitter

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

4/2 way Pneumatic Solenoid Valve

Tightness control TC. Product brochure GB 3 Edition AGA

UPGRADABLE PRESSURE BALANCE BAT/SOWER FITTING VOLUME AND TEMPERATURE CONTROL VALVE 1-5/8" TO 3-1/ ROUG VALVE OPTIONS 1/2" NPT 1/2" NOM or 1/2" NOM or

Oxidation Stability of Gasoline and Aviation Fuels

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

RCD - Ultra-Rugged Differential Pressure Flowmeter

SPCH/ Blowing block

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

SonoSelect 10 and SonoSafe 10 energy meters

Programmable Submersible Level Transmitters

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Scald Protection Three-Way Thermostatic Mixing Valve

Harmony. Pressure Independent Balancing and Control Valve

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

MB610 Industrial Pressure Transmitter

How to specify a product. Process Sensors and Mechanical Instruments

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

2/2-Way Proportional Valve (motor-driven)

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

Pneumatic high-pressure controller Model CPC7000

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Series e700 Combination T/P Valve Provides Unsurpassed Protection from Temperature & Pressure

differential pressure regulating valve - threaded

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

QBS Electronic Pressure Regulator

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Mass Flow Controller (MFC) for Gases

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Mass Flow Meter (MFM) for gases

JUMO dtrans p30 Pressure Transmitter

Visualize Nitrogen Gas Consumption

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Valve Proving System VDK 200 A S06*

self closing tapware and bubblers AUTOMATIC SHUT-OFF REDUCE WATER WASTE IMPROVE HYGIENE VANDAL RESISTANT Spring Action Series Time Flow Series

Pneumatic high-pressure controller Model CPC7000

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

2/2-way proportional valve

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Pressure Independent Control Valves

Transcription:

Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors Programmable temperature Programmable service flush Programmable thermal disinfection mode Valve usage data logging capabilities Multiple valves can be data linked together to form a network)) 25

Outlook Water Temperature Control - Groups of Fixtures Outlook is a six outlet digital mixing valve which enables precise group fixture flow and temperature control for showering and hand washing applications. Outlook offers a digital solution to facilities seeking compliance prevailing legionella control guidelines. For secure or otherwise controlled institutional showering applications, Outlook is available with a range vandal resistant and antiligature showerheads and is operable by touch/no touch wall mounted sensors. For institutional hand washing applications, Outlook is available with a series of lavatory spouts operable by either integral spout located no touch or touch/no touch wall mount sensors. For the commercial public washroom, Outlook offers a single digital mixing valve option for multiple lavatories where ASSE1070 point of use compliance is required. * Minimum flow rate of 1.5 GPM represents the minimum flow through the six outlet mixing valve for optimum performance. For metered lavatory applications an individual Outlook outlet serving a single fixture meets the requirement of ASME A112.18.1 as referenced in ASSE 1070 of.25gpm per operating cycle. Outlook (gpm) Model Pressure Drop (psi) Min. 5 10 15 20 25 30 35 40 45 50 Flow C V Six Outlet Mixing Valve 7 10 12 14 15 17 18 19 21 22 1.5* 3.1 26

Outlook Components Flow Control No Touch Infra-Red Wall Sensor for Shower or Lavatory Designed for use in schools, recreation and sports centers and similar buildings where medium duty vandal resistance is desirable. Polymer with Durable Polished Chrome Finish. 2.7 (68 mm).9 (22 mm) 3.3 (84 mm).2 (6 mm) For a submittal drawing, refer to D46012. Shipping Weight: 1.5 lbs. Flow Control Touch Piezo Wall Sensor for Shower or Lavatory Designed for use in prisons, psychiatric facilities and similar buildings where a higher level of vandal resistance is desirable. Stainless Steel..4 (9 mm) For a submittal drawing, refer to D46014. Shipping Weight: 6.5 lbs. 1.0 (25 mm).2 (5 mm) 27

Outlook Components Flow Control No Touch Spout Sensor for Lavatory Designed for use in the public washroom. Brass with Durable Polished Chrome Finish. Available in 6 /150 mm, 7 1/2 /190mm and 9 /225 mm lengths. 4.3 (110 mm) 7.3 (185 mm) 5.9 (150 mm) 7.5 (190 mm) 8.6 (225 mm) For a submittal drawing, refer to D46015. Shipping Weight:.5 lbs. Six Outlet Mixing Valve Polymer Enclosure with Brass/Stainless Steel internal components. 21.2 (541 mm) 20.1 (511 mm) 7.4 9.2 (187 mm) (233 mm) 6 x ½ 15 mm 2.2 3.1 1.7 (56 mm) (78 mm) (44 mm) For a submittal drawing, refer to D46016. Shipping weight combined with Sensor Control Box: 17 lbs. 3.3 (84 mm) Sensor Box Polymer Electronics Enclosure. 10.0 (255 mm) 5.3 (134 mm) 1.5 (37 mm) For a submittal drawing, refer to D46017. 28

Outlook - Technical Specifications Connections.75 (20 mm) HW (1) & CW (1) inlet flat faced union connections..5 (15 mm) Mixed water outlet (6) flat faced unions Approvals ASSE 1070 BS EN ISO 9001:2008 Quality Management Systems and BS EN ISO 14001:2004 Environmental Management Systems Lead Free Compliant. Operation Wall Sensor flow control: Non-touch ON/OFF. Touch ON/OFF. Non-touch ON/OFF spout. Materials Mixing unit enclosure: PC/ABS. Integral components: DZR brass, stainless steel, engineering plastic. IP Rating Mixer Valve: IP24. Sensor Box: IP20. PSU: IP45. Electrical Specification Supply Voltage: 100-240 V RMS 50-60 HZ. 1.5 A Maximum load: 40 W at 12 V DC. Valve to sensor box cable length: 1.5m Sensor box to sensor cable length: 6m. Flow Times and Duty Flush Factory settings Flow time: 30 seconds. Duty flush cycle: 2 minutes. Duty flush waiting period: 3 days. Programmable range Flow time: 5 sec - 60 min. Duty flush cycle: 1 min - 59 min. Duty flush waiting period: 1 hr - 983 hrs. Duty flush not enabled at factory, programming required. Temperature Range Factory pre-set: Default 100 F (38 C). Programmable range: Min 86 F (30 C) 116 F (47 C) Maximum: 91 F (33 C) 122 F (50 C) Default 86 F (30 C) 122 F (50 C) at start up, or full cold only can be selected. Minimum blend temperature differential from hot supply: 5 F (2 C). Optimum thermostatic control range: (86 F) 30 C 122 F (50 C). Cold water range (recommended): 1 C - 20 C Inlet Hot water range (recommended): 122 F (50 C) 149 F (65 C) Maximum Inlet Hot Water 185 F (85 C) Temperature stability: ± 2F (1 C) for recommended supply conditions. Pressures Maximum static pressure: 115 PSI (8 bar) Minimum pressure loss: 15 PSI (1 bar) Hot and cold pressure should be nominally equal: Max differential 3:1 Flow Rates Minimum flow rate per outlet:.5gpm (1,4lpm) Environment Ambient temperature: 33 F (1 C) 104 F (40 C). Maximum relative humidity: 95% non-condensing. Suitable for indoor use only. Disinfection Factory settings - Standard Target time: 5 minutes. Max Warm Up: 1 min. Timeout: 10 mins. Target temperature: 140 F (60 C). Programmable range Temperature: 140 F (60 C) - 175 F (80 C). Time: 1-59 minutes. Configuration Tool A Laptop/PC is required to adjust factory settings, retrieve data, configure duty flush and disinfection cycles. The programmer software available is designed to run on Microsoft Windows XP/Vista operating systems. Please refer to the appropriate software manual. Sensor Box Web enabling on-line approach and linking on building management network is possible, or sensor box can be linked directly to Building Management System (BMS), via Modbus. Features Connections for 6 control sensors Connect to multiple sensor boxes in a network* (Modbus) Connection for motion (safety) PIR Connection for ventilation circuit * Maximum number of sensor boxes in a single network = 31 29