Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors Programmable temperature Programmable service flush Programmable thermal disinfection mode Valve usage data logging capabilities Multiple valves can be data linked together to form a network)) 25
Outlook Water Temperature Control - Groups of Fixtures Outlook is a six outlet digital mixing valve which enables precise group fixture flow and temperature control for showering and hand washing applications. Outlook offers a digital solution to facilities seeking compliance prevailing legionella control guidelines. For secure or otherwise controlled institutional showering applications, Outlook is available with a range vandal resistant and antiligature showerheads and is operable by touch/no touch wall mounted sensors. For institutional hand washing applications, Outlook is available with a series of lavatory spouts operable by either integral spout located no touch or touch/no touch wall mount sensors. For the commercial public washroom, Outlook offers a single digital mixing valve option for multiple lavatories where ASSE1070 point of use compliance is required. * Minimum flow rate of 1.5 GPM represents the minimum flow through the six outlet mixing valve for optimum performance. For metered lavatory applications an individual Outlook outlet serving a single fixture meets the requirement of ASME A112.18.1 as referenced in ASSE 1070 of.25gpm per operating cycle. Outlook (gpm) Model Pressure Drop (psi) Min. 5 10 15 20 25 30 35 40 45 50 Flow C V Six Outlet Mixing Valve 7 10 12 14 15 17 18 19 21 22 1.5* 3.1 26
Outlook Components Flow Control No Touch Infra-Red Wall Sensor for Shower or Lavatory Designed for use in schools, recreation and sports centers and similar buildings where medium duty vandal resistance is desirable. Polymer with Durable Polished Chrome Finish. 2.7 (68 mm).9 (22 mm) 3.3 (84 mm).2 (6 mm) For a submittal drawing, refer to D46012. Shipping Weight: 1.5 lbs. Flow Control Touch Piezo Wall Sensor for Shower or Lavatory Designed for use in prisons, psychiatric facilities and similar buildings where a higher level of vandal resistance is desirable. Stainless Steel..4 (9 mm) For a submittal drawing, refer to D46014. Shipping Weight: 6.5 lbs. 1.0 (25 mm).2 (5 mm) 27
Outlook Components Flow Control No Touch Spout Sensor for Lavatory Designed for use in the public washroom. Brass with Durable Polished Chrome Finish. Available in 6 /150 mm, 7 1/2 /190mm and 9 /225 mm lengths. 4.3 (110 mm) 7.3 (185 mm) 5.9 (150 mm) 7.5 (190 mm) 8.6 (225 mm) For a submittal drawing, refer to D46015. Shipping Weight:.5 lbs. Six Outlet Mixing Valve Polymer Enclosure with Brass/Stainless Steel internal components. 21.2 (541 mm) 20.1 (511 mm) 7.4 9.2 (187 mm) (233 mm) 6 x ½ 15 mm 2.2 3.1 1.7 (56 mm) (78 mm) (44 mm) For a submittal drawing, refer to D46016. Shipping weight combined with Sensor Control Box: 17 lbs. 3.3 (84 mm) Sensor Box Polymer Electronics Enclosure. 10.0 (255 mm) 5.3 (134 mm) 1.5 (37 mm) For a submittal drawing, refer to D46017. 28
Outlook - Technical Specifications Connections.75 (20 mm) HW (1) & CW (1) inlet flat faced union connections..5 (15 mm) Mixed water outlet (6) flat faced unions Approvals ASSE 1070 BS EN ISO 9001:2008 Quality Management Systems and BS EN ISO 14001:2004 Environmental Management Systems Lead Free Compliant. Operation Wall Sensor flow control: Non-touch ON/OFF. Touch ON/OFF. Non-touch ON/OFF spout. Materials Mixing unit enclosure: PC/ABS. Integral components: DZR brass, stainless steel, engineering plastic. IP Rating Mixer Valve: IP24. Sensor Box: IP20. PSU: IP45. Electrical Specification Supply Voltage: 100-240 V RMS 50-60 HZ. 1.5 A Maximum load: 40 W at 12 V DC. Valve to sensor box cable length: 1.5m Sensor box to sensor cable length: 6m. Flow Times and Duty Flush Factory settings Flow time: 30 seconds. Duty flush cycle: 2 minutes. Duty flush waiting period: 3 days. Programmable range Flow time: 5 sec - 60 min. Duty flush cycle: 1 min - 59 min. Duty flush waiting period: 1 hr - 983 hrs. Duty flush not enabled at factory, programming required. Temperature Range Factory pre-set: Default 100 F (38 C). Programmable range: Min 86 F (30 C) 116 F (47 C) Maximum: 91 F (33 C) 122 F (50 C) Default 86 F (30 C) 122 F (50 C) at start up, or full cold only can be selected. Minimum blend temperature differential from hot supply: 5 F (2 C). Optimum thermostatic control range: (86 F) 30 C 122 F (50 C). Cold water range (recommended): 1 C - 20 C Inlet Hot water range (recommended): 122 F (50 C) 149 F (65 C) Maximum Inlet Hot Water 185 F (85 C) Temperature stability: ± 2F (1 C) for recommended supply conditions. Pressures Maximum static pressure: 115 PSI (8 bar) Minimum pressure loss: 15 PSI (1 bar) Hot and cold pressure should be nominally equal: Max differential 3:1 Flow Rates Minimum flow rate per outlet:.5gpm (1,4lpm) Environment Ambient temperature: 33 F (1 C) 104 F (40 C). Maximum relative humidity: 95% non-condensing. Suitable for indoor use only. Disinfection Factory settings - Standard Target time: 5 minutes. Max Warm Up: 1 min. Timeout: 10 mins. Target temperature: 140 F (60 C). Programmable range Temperature: 140 F (60 C) - 175 F (80 C). Time: 1-59 minutes. Configuration Tool A Laptop/PC is required to adjust factory settings, retrieve data, configure duty flush and disinfection cycles. The programmer software available is designed to run on Microsoft Windows XP/Vista operating systems. Please refer to the appropriate software manual. Sensor Box Web enabling on-line approach and linking on building management network is possible, or sensor box can be linked directly to Building Management System (BMS), via Modbus. Features Connections for 6 control sensors Connect to multiple sensor boxes in a network* (Modbus) Connection for motion (safety) PIR Connection for ventilation circuit * Maximum number of sensor boxes in a single network = 31 29