HOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL

Similar documents
Contents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2

G&H SPC-1 SANITARY PROPORTIONAL-CONTROLLED VALVE WITH POSITIONER INSTRUCTION MANUAL IM US1 S 0812

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Operating instructions - Translation of the original -

DelVal Flow Controls Private limited

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

3/8" Dr. Air Butterfly Impact Wrench

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Two-port valves, male threaded, PN25

kysimply Unique Single Seat

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Instruction Manual. CPM-2 Constant-Pressure Modulating Valve IM70775-EN

H4802, H4802-1, H , and Pole Tampers

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Installation & Operation Manual Proven Quality since 1892

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Operating instructions - Translation of the original -

Operating instructions - Translation of the original -

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

SMP-BC Sanitary Mixproof Valve

Operating instructions - Translation of the original -

12S 1st Stage. -Maintenance Procedure-

Manual Actuated Boiler Blowdown Valves

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

Telefon (+45) Telefax (+45)

FLANGED MULTI-PORT BALL VALVES

Pressure Dump Valve Service Kit for Series 2300 Units

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Engineering Data Sheet

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Pressure Relief Valve DHV 718

CS150 CAP STAPLER OWNER S MANUAL

Pressure Reducing Valve

DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP-2000

OWNER S TECHNICAL MANUAL

PARTS, SERVICE & REPAIR BULLETIN

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

INTENDED USE TECHNICAL SPECIFICATIONS

Operation and Maintenance Instructions

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: K

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Operating Procedure TITON SUBSEA BOLT TENSIONER

SECTION BUTTERFLY VALVES

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

Operating instruction

OPERATING AND MAINTENANCE MANUAL

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Gas Welding Hoses and connections, the weak link

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Instruction presentation Special valves

CYL KNIFE GATE VALVES San Sebastian Spain

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

World Area Differences Technical Information

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Valves. Diaphragm shut-off valves, kidney-type

Flowmeter. Original operating manual DFM

Type ACE95jr Tank Blanketing Valve

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TYPE BV2-LD

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: FK

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

APT14, APT14HC and APT14SHC Spares 2

Siphon vessel / Priming aid

Instruction Manual Updated 7/26/2011 Ver. 2.2

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

RAIMONDI. 3-way globe valve for feedwater heater outlet bypass Installation and Maintenance Instructions

INSTALLATION, MAINTENANCE & OPERATING INSTRUCTIONS 2-4 REDUCED PORT/ FULL PORT (5700/6700) ANSI CLASS 150/300/600/900/1500/2500 TRUNNION BALL VALVES

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Armatures for analytical probes

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Pressure Reducing Valve DMV 750

LRS(H)4 Pressure-Reducing Regulator User Manual

shutoff valves 900 Series psig Manual Shutoff Valves

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Control Valves ZK 610 ZK 613

CO2 Tank Conversion Kit P.N , P.N , and P.N

JARVIS. Model CPE Hock and Neck Cutter EQUIPMENT... TABLE OF

Two-port seat valves

Model 4000 Pressure Controller

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Type ACE97 Pad-Depad Valve

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Instruction Manual. AlfaLavalSBAntiVacuumValve ESE02960-EN Original manual

Technical Data Sheet TI-F50 Locking Units series KFH

Constant Pressure Crude Oil Container Model CPCCP

Transcription:

1 CONTENTS 2 Introduction 2 2.1 Valve use 2 2.2 Application area 2 2.3 Incorrect use 2 3 Safety 2 4 Transport and storage 2 5 Installation instructions 2 5.1 Mounting 2 5.2 Installation into pipework 2 5.3 Operating space 2 5.4 Mounting space 2 6 Operation 3 6.1 Operation with air 3 6.2 Indication of valve position 3 6.3 Control unit 3 7 Cleaning and maintenance 3 7.1 Cleaning 3 7.2 Lead-time 3 7.3 Safety measures during maintenance 3 7.4 Grease to be used 3 7.5 Disassembling the valve 3 7.6 Assembling angle- and multiway valves 4 7.7 Assembling change-over valves 4 7.8 Actuator 4 7.9 Failures 4 Appendix A: Technical specification 5 Version and ordering code 5 Valve material 5 Gasket material 5 Air supply pressure 5 Liquid operating pressure 5 Operating temperature 5 Air consumption 5 Appendix B: Cross-section 6 Appendix C: Parts and spare parts 7 Parts 7 Spare parts 7 Ordering spare parts 7 www.pentair.com/valves 2012 Pentair Ltd. All Rights Reserved. HOVSB-0033-EN-1408

2 INTRODUCTION 2.1 Valve use The Hovap Basicflow process valve series 9600 is a valve with a single seat. This valve can be supplied as angle-, multiway- and change-over valve. 2.2 Application area The valve has been designed for use in the food and beverage and pharmaceutical industries. 2.3 Incorrect use The valve is not suitable for use in gas systems. Liquids with hard solid parts cause increased wear to the gaskets. 3 SAFETY Prevent that, during maintenance, liquids can pressurize the pipework in which the valve has been installed. There must be a free space of at least 200 mm above the valve. This prevents the jamming of parts of the body during opening/closing of the valve. Prevent that fingers or hand get jammed between valve and seats during operation of a disconnected valve. During cleaning at elevated temperatures, the valve can become so hot that touching the surface causes burning. 4 TRANSPORT AND STORAGE The valve has been wrapped in plastic. This prevents dust and dirt entering the valve interior. Re-wrap the interior when the valve is unpacked for installation of the body into the pipework. The quality of O-rings may deteriorate during long-term storage. 5 INSTALLATION INSTRUCTIONS 5.1 Mounting If possible, install the valve such that it closes against the flow direction. This prevents water hammer. 5.2 Installation into pipework The valve can be welded in every position in the pipework. Remove the valve internal parts, together with O-rings and gaskets, before welding. 5.3 Operating space A free space of at least 50 mm is required above the valve. 5.4 Mounting space To allow valve assembly and disassembly, a free space at least 250 mm is required above the actuator. Before disassembling a spring-to-close valve, the spring pressure must be eased by opening the valve with the air supply. Never try to open the actuator. The actuator is spring loaded! 2

P I 6.2 Indication of valve position The valve can be provided with a bracket for proximity switches. Following positions are possible: A B P II Valve(s) up Valve(s) down Both situations 6 OPERATION 6.1 Operation with air The valve is provided with two air connections with ⅛ BSP female thread. Angle- and multiway valves (A): P I: Close valve (for spring-to-open and double-acting valves). P II: Open valve (for spring-to-close valves). Change-over valves (B): P I: Connect lower and top body. Close bottom port (for spring-to-open and double-acting valves) P II: Disconnect lower and top body. Opening bottom port (for spring-to-close valves). The spring action must not be amplified by supplying air. This causes damage to the valve parts. Air connections that are not in use must be fitted with bleeding nipples. 6.3 Control unit The valve can also be provided with a control unit. Most commercially available units can be fitted. 7 CLEANING AND MAINTENANCE See Appendix B 7.1 Cleaning The valve material is resistant to detergents that are commonly used in the food industry, such as a lye (NaOH) or acid (HNO 3 ) solution of about 2½% at a temperature of about 80 C. After cleaning, the system must be rinsed with clean water to prevent corrosion. 7.2 Lead-time Sealing and wearing parts of the valve must be checked once a year. For special applications (such as highly viscous or crystallizing liquids) the lead-time must be adjusted in consultation with the manufacturer. 7.3 Safety measures during maintenance When disassembling the valve, the pipework must be empty. With disassembled valves, it must be prevented that the pipework can be filled accidentally by, e.g. starting a pump or activating a valve. Before disassembling a spring-to-close valve, it must be moved by the air supply to the open position. This prevents the valve being opened during assembly and disassembly by the spring s closing force. 7.4 Grease to be used The O-rings must be greased with grease that has been approved for use in the food industry. We recommend Molykote 111. 7.5 Disassembling the valve A - Remove, if present, the indicators. B - For spring-to-close valves, supply pressurized air to P II. C - Loosen clamp 12. D - Pull actuator 8, together with interior, from valve body 1 or 2. E - For spring-to-close valves, remove air pressure from P II; for spring-to-open multiway valves, supply pressurized air to P I. F - Loosen valve/insert with shaft 3/13. G - Angle- and multiway valves: remove valve plate 6 from valve and shaft 3. Change-over valves: remove valve plate 7 from insert and shaft 13. H - Loosen insert 5. I - Check all O-rings. 3

7.6 Assembling angle- and multiway valves General: Male thread connections must be secured with Loctite 243. A - Mount insert 5 with O-ring 20 on valve and shaft 3. B - Mount valve plate 6 with O-rings 21 and 22 over valve and shaft 3. C - Screw valve and shaft 3 into the actuator shaft. D - For spring-to-close valves, supply pressurized air to P II E - Install actuator 8, together with valve interior in valve body 1. F - Fasten clamp 12. G - For spring-to-close valves, remove air pressure from P II. H - Check if the valve operates smoothly. I - Install, if required, the indicators. 7.7 Assembling change-over valves General: Male thread connections must be secured with Loctite 243. A - Mount insert 5, change-over valve 4 and O-rings 20 on insert and shaft 13. B - Mount stem valve plate with seat 7 with O-rings 21, 22 and 23 on insert and shaft 13. C - For spring-to-open valves, supply pressurized air to P I. D - Screw insert and shaft 13 and stem valve plate with seat 7 into the actuator shaft. E - For spring-to-open valves, remove air pressure from P I; for spring-to-close valves, supply pressurized air to P II. F - Install actuator 8, together with valve interior, in valve body 2. G - Fasten clamp 12. H - Check if the valve operates smoothly. I - Install, if required, the indicators. 7.9 Failures Valve closes with great force Valve closes in the flow direction. Try to install the valve such that the valve closes in the opposite direction. If this is not possible, install a throttling actuator on top of the main actuator. Valve is opened by liquid pressure Liquid operating pressure is above 5 bar. Air supply pressure is below 6 bar. Leakage along stem valve Check O-rings 21. Leakage at clamp 12 Check O-rings 22. Leakage along valve Check O-ring(s) 20 and 23. Air leakage via actuator shaft Check O-rings. Air leakage via air connections of actuator Send actuator to Hovap for repair. Valve opens/closes slowly Air supply pressure is below 6 bar. Air tube is too long, is pinched, or the diameter is too small. Liquid in the actuator. Valve opens/closes with irregular movement Check if there is liquid in the actuator. Liquid in actuator Put a water separator in the air supply. 7.8 Actuator The actuator is spring loaded. Never try to open the actuator. The O-rings can be changed by dismounting the O-ring retainer 19 and top cover 18. The spring action of the valve can be changed by reversing the complete actuator. 4

APPENDIX A - TECHNICAL SPECIFICATION VERSION AND ORDERING CODE The following versions are available: VERSION ORDERING CODE 9601 9602 9611 9612 9621 9622 VALVE MATERIAL All metal parts that come into contact with the liquid are made of stainless steel according to W.Nr. 1.4401. The metal parts that do not come into contact with the liquid are made of stainless steel W.Nr. 1.4301. The actuator bearings are made of polyacetate. Gasket material The O-rings that come into contact with the liquid are made of EPDM. Alternatives are available. Air supply pressure The air supply pressure must be between 5 and 10 bar. We recommend dry air of 6 bar. Liquid operating pressure The maximum liquid operating pressure for spring-to-close and spring-to-open valves is 5 bar. For double-acting valves this is 10 bar. These values will be reached at an air supply pressure of 6 bar. Operating temperature Valves with standard O-rings can resist a maximum temperature of 140 C. Air consumption The air consumption in nl. per stroke is given in the table below. The consumption is calculated at 6 bar air pressure. Dimension Spring-to-close and spring-to-open Double acting 1½ 1.3 4.3 2 1.3 4.4 2½ 2.8 12.3 3 3.3 13.1 4 5.4.5 5

APPENDIX B - CROSS-SECTION 18 18 8 8 19 19 21 21 9 6 7 9 12 22 22 12 1 2 3 13 20 23 5 20 4 20 5 6

APPENDIX C - PARTS AND SPARE PARTS PARTS Ref. no. Qty. Material Angle- and multiway valve Change-over valve 1 1 W. Nr. 1.4401 Valve body - 2 1 W. Nr. 1.4401 - Valve body 3 1 W. Nr. 1.4401 Valve and shaft - 4 1 W. Nr. 1.4401 - Change-over valve 5 1 W. Nr. 1.4401 Insert Insert 6 1 W. Nr. 1.4401 Stem valve plate - 7 1 W. Nr. 1.4401 - Stem valve plate with seat 8 1 W. Nr. 1.4301 Actuator Actuator 9 1 W. Nr. 1.4301 Connection piece Connecting piece 12 1 St. Steel Clamp Clamp 13 1 W. Nr. 1.4401 - Insert and shaft 18 1 W. Nr. 1.4301 Top cover Top cover 19 1 W. Nr. 1.4301 O-ring retainer O-ring retainer 20 ½ EPDM-FDA O-ring O-ring 21 2 EPDM-FDA O-ring O-ring 22 1 EPDM-FDA O-ring O-ring 23 1 EPDM-FDA - O-ring 2 FPM O-ring O-ring SPARE PARTS 1½ 2 2½ 3 4 Ref. no. Descr. DN 40 DN 50 DN 65 DN 80 DN 100 20 O-ring 43.82 x 5.33 50.17 x 5.33 62.87 x 5.33 81.92 x 5.33 100.97 x 5.33 21 O-ring 18 x 3 18 x 3 18 x 3 22 x 3 22 x 3 22 O-ring 56.52 x 5.33 66.04 x 5.33 75.57 x 5.33 94.62 x 5.33 113.67 x 5.33 23 O-ring 50.17 x 5.33 59.69 x 5.33 69.22 x 5.33 88.27 x 5.33 107.32 x 5.33 O-ring 20 x 3 20 x 3 22 x 3 22 x 3 22 x 3 ORDERING SPARE PARTS When ordering spare parts, please include the following information: The valve number. The valve ordering code. See Appendix A. The valve size. The valve part position number. The quality of any O-rings. PENTAIR VALVES & CONTROLS www.pentair.com/valves All Pentair trademarks and logos are owned by Pentair Ltd. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change product designs and specifications without notice. Pentair is an equal opportunity employer. 2012 Pentair Ltd. All rights reserved. 7