New AQF Filter Polymer Filtration System

Similar documents
Digital Melting Point Apparatus

Norrsken Family Booklet

PRAHER PLC-MP AQUASTAR MANAUL 2009

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

VERTICAL AIR COMPRESSORS

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

STAGE, STADIUM & X-TREME SHOT.

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Spirax Compact FREME Flash Recovery Energy Management Equipment

80 Litre Suction Oil Drainer

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

VERTICAL AIR COMPRESSORS

! Warning, refer to accompanying documents.

Accu-Tab Systems 1000 Series by Axiall Corporation

AR740 RPS Redundant Power Supply Quick Install Guide

SPA WORLD. Pre- delivery Guide

HYDROVEX TTT Membrane Flow Regulator

Saline C 6.0 Junction Box

12V Mini Air Compressor

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

ENERGY BLADE 3K4. Energy Blade Installation Instructions

J Air and Water Kit Instructions Part# 02584

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

User Manual 1 P a g e Rev. V1.6-EN 11/08/2014

92831 TEL: (714) FAX:

Accu-Tab Systems 2000 P Series by Axiall Corporation

Vertex VP Operation and Maintenance

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

200L BELT DRIVEN AIR COMPRESSOR

Isolation of power supplies

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

OPERATING AND MAINTENANCE MANUAL GOLD LINE EXTRACTION CLEANERS M14-M26

SHHH AIR COMPRESSOR Model Nos. SHHH5/24 - SHHH5/50 - SHHH7/100

Operating Instructions Part No

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

4-in-1 Professional Inflator Kit

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

MODELS (2 foot Version) (4 foot Version)

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Vacufill MACHINE FOR FAST, ECONOMICAL AND EFFECTIVE COOLANT EXCHANGE, THE VACUFILL, WHILST UNDER VACUUM REFILLS THE COOLING SYSTEM IN SECONDS

L230 LED 40 Watt Searchlight

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

PPS PORTABLE POWER SUPPLY

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

Solaris Nitrogen. Installation Guide. Solaris Nitrogen Installation Guide Rev 1 PN IG /09/16

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

30T A/Manual Hydraulic Shop Press

Operating Instructions Part No

Installation, Operation & Maintenance Instructions

Siphon vessel / Priming aid

In Vessel Composter Installation & Commissioning Manual

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Airmate TS1.5/6 Oil-less Air Compressor

Operating Instructions in accordance with the Machines Directive 2006/42/EC

CUT OFF TOOL MODEL: CAT113

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Blue Whale Spa :- Site Preparation and Delivery

WIKA INSTRUMENT CORPORATION

Accu-Tab PowerBase 3012AT by Axiall Corporation

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

D Series Air and Water Kit Part# 02550

COOPER POWER SERIES. Manual or Hostick Operable, Padlockable 150 A Tap-Changer Switch Installation Instructions. Tap-Changer Switch MN800015EN

COOPER POWER SERIES. UltraSIL Polymer-Housed Distribution-Class MOV Surge Arrester Installation Instructions. Surge Arresters MN235006EN

12V MINI AIR COMPRESSOR

Budget Range Operators Handbook

COOPER POWER SERIES. UltraSIL polymer-housed VariSTAR surge arrester IEC for MV systems to 36 kv installation instructions

Gas Countertop Hot Plates

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

T EK-SUB 4800C 19 mm Submersible Level Transmitter

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

MP15 Jockey Pump Controller

Model: 43T. Bermad Pressure Relief Valve

Operating Manual for the Evance Iskra R9000 Wind Turbine

100C Air Compressor Kit

Chlorinator MODEL MK-I

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

RPS900W Redundant Power Supply. Installation Guide.

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

LSX Low Smoke Convertor Operations Manual

EDUCATION DEPARTMENT ACCU-TEST

Transcription:

New AQF Filter Polymer Filtration System Operator Manual Covering Serial Number 20002001 onwards February 2011

Index Disclaimer notice...3 Introduction...4 Important safety notices...5 Getting started...6 Installation...8 Connections...9 Operation...12 Care and maintenance...12 Specification...13

Disclaimer Disclaimer Notice This manual has been validated and reviewed for accuracy. Dantex does however pursue a policy of continuous product improvement and succeeding products are therefore subject to change without notice. Whilst every effort is made to ensure accuracy, Dantex makes no warranty of any kind with regards to this material either express or implied. Dantex assumes no liability for damages of any nature incurred either directly, incidentally or consequentially from the use of this material. If there are any points requiring clarification please contact Dantex who will be pleased to advise. This document contains proprietary information. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without prior written consent of Dantex. The information contained in this document is subject to change without notice. Important This manual contains important safety and operational information. Read carefully before attempting installation or operation. Save this manual for future reference.

Introduction Disclaimer Notice Thank you for choosing the New AQF Filter manufactured by Dantex, a company committed to providing the best graphic equipment solutions to the Flexographic Industry. This handbook is provided to allow the safe installation, operation and maintenance of the equipment. Please take time to read this, as it will ensure reliable, safe, operation and the best plate quality to be achieved. If, although very unlikely, you should experience any problem, Dantex technicians are available to answer your questions. Please do not hesitate to ask! Using you re Dantex Documentation For ease of use the following conventions are used throughout the manual: Notes that provide advice or suggestions to help you obtain best results. Indicates that neglecting the suggested procedure or recommendation could result in damage to the equipment or the plates. CAUTION Alerts you to conditions that could cause personal injury.

Important Safety Notices Important Notice This equipment meets statutory safety requirements. Incorrect installation or use however can lead to potentially dangerous situations leading to personal injury or damage to the equipment. Before attempting installation or use read all the following instructions carefully. They provide essential information on safety. Please keep this document in a safe place for reference and pass them on to any future users. Correct Usage - Limitations of Use The Recycling Unit Flexo/Water is designed for use in dry environments and is specifically intended to be used together with flexo/water equipments to recycle water. For your safety To avoid damage or injury, before wiring in the equipment, be sure the electrical supply corresponds to the details shown on the electrical rating plate attached to the machine and ensure a secure ground (earth) connection is provided and connected in accordance with local regulations. If in any doubt, contact A.G.I. for advice and do not turn on the electrical supply or attempt to operate the equipment. Never operate the equipment unless you are completely familiar with all aspects of its operation and location of safety devices and never operate with covers removed or override any safety devices. Always ensure the electrical supply is isolated before cleaning, maintenance or trouble shooting. Avoid dangerous environments. Do not use if equipment is damp or wet. Consult expert advice if an abnormal condition develops. Repairs should only be carried out by a qualified service technician, familiar with the hazards that may be present. Dantex cannot be held responsible for any damage or personal injury if the unit is not used in according to the instructions or for uses other than those for which it is intended.

Getting Started Responsibilities Dantex will ship the equipment ordered to a specified site location. Dantex is not responsible however for site preparation, installation and commissioning of the unit. This is the responsibility of either the end user or dealer as appropriate. The following points must be carefully planned in advance to facilitate a smooth trouble free installation: 1) Pre installation site preparation. This includes planning access into the building, making space available for the equipment that meets the specification requirements and ensuring all services such as electrical and extraction are ready and are of sufficient capacity. Please see guidance notes below. 2) Correct delivery address and instructions. 3) Preparation for unloading from the delivery vehicle. Hazard Warning Wear protective gloves, safety glasses and clothing when unpacking and installing equipment and take care of the hazards presented by nails, broken wood etc during the unpacking process. Take care when lifting heavy sections. Ensure sufficient personnel are used or use lifting devices as appropriate to prevent back or personal injury. Uncrating Carefully unpack the unit and check for any damage in transit. If any damage is found this must be notified immediately to the delivery company/insurers. Do not proceed with installation or operate the unit if damage has occurred. Check the contents against the packing list for missing parts. Disposal of packing material Different packing materials may be used according to circumstances to protect you re A.G.I. equipment. Please help to protect the environment by taking this material to the nearest local authority collection point for specific waste material. Choosing a location for the equipment Before attempting installation it is important that the site chosen meets the necessary requirements for easy and safe operation and adequate service access. The equipment must be sited on a stable secure horizontal floor capable of supporting the weight of the equipment either directly. Sufficient space must be allowed.

Room Requirements Lighting Normal lighting may be used but care should be taken to protect light sensitive materials (film, photopolymer plates) If in doubt check with your consumables supplier. Environment A room temperature of 200 C and a relative maximum humidity of 55% should be maintained for ideal working and operational conditions. Ventilation To remove obnoxious smells during operation the room should be adequately ventilated. It is strongly recommended that a professional heating and ventilation contractor be used. Important Notice The above notes are provided as a guide. In all cases installation must conform to local and national codes of practice according to the country in which the equipment is installed.

Installation Important Safety Notice Installation should only be carried out by competent personnel proficient with installation work and equipped with all the tools for each stage of the installation. In particular take note of the following precautions; follow instructions given in this manual carefully and observe precaution & warning notices.never operate the equipment with guards or safety panels removed or override safety switches. These are provided to ensure your safety! Prior to assembly it is recommended that the entire interior of the recycling unit is vacuumed to remove any foreign matter that may have accumulated during transport or during manufacture. Mechanical Assembly The Recycling Unit is an All in one unit ready assembled. You simply have to position the equipment and level it. Electrical Connections Before attempting electrical connection, check the details on the equipment supply rating plate conform to the supply available (also see important note below Line voltage ) If correct, connect the recycling unit to an adjacent isolator using the cable provided. Electrical connections must comply with local and national safety codes and must only be performed by competent and qualified electricians aware of the safety hazards present. If overrides of safety circuits or features are performed during installation or commissioning for any reason, these must all be restored and checked for correct operation before normal operation is permitted. It is strongly recommended that during electrical connection, troubleshooting or servicing that the main power supply to the machine is disconnected and the isolator locked out using a physical padlock to prevent it being inadvertent. Line Voltage It is very important to ensure that the line voltage is correct for the equipment supplied. Standard voltage is 230 V - F+N 50Hz 60Hz. No warranty claims will be honoured for equipment operated outside the voltage limits. If the electrical supply available is outside these limits a voltage correction transformer must be used. To ensure safe operation the equipment must be provided with a protective ground (earth) connection. Ground continuity must be checked and verified at the time of installation. The fitment of a ground fault interrupter is highly recommended.

Connections BLEEDER VENT VALVE FILTER OPENING VALVE; IT IS CONNECTED TO THE PUMP THROUGH A Ø25mm PIPE WATER INLET FROM THE PUMP TO THE FILTER WATER CHARGE FROM MAIN TANK FILTER DISCHARGE WATER INLET FROM THE FILTER TO THE MAIN TANK

Connections WATER INLET FROM FILTER TO MAIN EQUIPMENT TANK CONNECTION PIPE BETWEEN PUMP AND FILTER WATER CHARGE FROM MAIN EQUIPMENT TANK ELECTRICAL CONNECTION BETWEEN PUMP AND EQUIPMENT

Connections VALVE ON OPEN POSITION VALVE ON CLOSE POSITION

Operation In order to operate with the Recycling Unit Flexo/Water, after connecting it to the main equipment as shown, first of all you have to open the bleeder vent valve, thus discharging the air present in the filter; when the water begins to get out, the filter is ready to work. This must be also done each time you start using the filter again after emptying it in order to clean it. Then open the following valves: ~ Water inlet from the filter to the main equipment tank. ~ Filter opening valve. When you turn the equipment on, the recycling unit will automatically start working. Care and maintenance Warning: Do not attempt any maintenance until familiar with the equipment and the safety notices outlined in this document. Always ensure that the electrical supply is turned off and isolated before removing any panels or accessing parts. Simple maintenance can be performed by competent technicians but any serious abnormal conditions or replacement of parts should be referred to Dantex before attempting any work. The Recycling Unit has been designed for minimum maintenance. However, proper care and regular preventative maintenance will minimise the chances of failure and ensure optimum work quality. Please check the pressure gauge mounted on the filter: When it is green, you can operate; when it becomes red, you need to empty the filter through the discharge valve. Before starting working again, don t forget to discharge the air by opening the bleeder vent valve.

Specifications RECYCLING UNIT FLEXO / WATER Electrical Nominal Intensity Nominal Power Dimensions (cm) 230V SINGLE PH. 50HZ 2,7 A 0,6 Kw 56 X 56 X 110H Net weight (kg) 23

NEW - AQF Filter YOUR PARTNERS IN WATERWASH PHOTOPOLYMER PLATE Plates TECHNOLOGY & more Aquaflex is a Registered Trademark Dantex Graphics Limited. Aquaflex equipment is manufactured in the United Kingdom by Dantex Dantex Graphics Limited Danon House 5 Kings Road Bradford West Yorkshire UK +44 (0) 1274 777 777 info@dantex.com www.dantex.com