POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

Similar documents
FLOWTRON HYDROVEN 3. User Manual. Intermittent Pneumatic Compression System

DYNAMIC COMPRESSION THERAPY

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

Intermittent Pneumatic Compression System

User manual. MNPG 102 Rev. 04 Edition 04/02/16. Pressotherapy model. Power-Q1000 Premium

CircuFlow TM 5150 Series

BTL-6000 LYMPHASTIM BTL PRESSO-THERAPY SYSTEM FOR MEDICAL AND AESTHETIC PRACTICES

12 Chamber Pump & Garment System for Lymphoedema

OPERATING INSTRUCTIONS FOR USE GUIDE

User manual. PG132 Rev01 Editi Compressive Limbs Therapy System DVT-7700

User manual. PG89 Rev 01 Editi Pressotherapy model. LymphoPress 4

Company building TOTAL SOLUTION OF AIR COMPRESSION THERAPY SYSTEM. New second factory. Main office & Factory Stories house

CircuFlow 5200 Series

CircuFlow Quick Setup Guide

User Manual. Indications for safety use This product is intended for use by medical professionals or patients who are under medical supervision.

CircuFlow TM 5208 Series

DYNAMIC COMPRESSION THERAPY

SEQUENTIAL CIRCULATORS

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

Customer Service See Service Provider Documentation

Paradise Pump Series Operator s Manual

FLOWTRON ACS800 +TRI PULSE INSTRUCTIONS FOR USE

Med Aire Alternating Pressure Pump and Pad System

SC505 Sof Care Inflator. Operating Instructions and Service Manual

Model IC-BAP-DL BioArterial Plus

Comfortmax Thermax Hot/Cold Water Circulation System. Instructions for Use

READYWRAP READYWRAP SOLARIS. Low Stretch Medical Binders. Low-stretch Adjustable Compression Wraps S I X E N O W S E I L A B L E

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

Advanced Pneumatic Compression. Flexitouch System MODEL PD32-U

NIMBUS range. with people in mind

1 METRON MANIPULATION TABLES - WARRANTY STATEMENT

SYMBOL DEFINITIONS. CAUTION: High pressure should be set with caution on patients with peripheral arterial occlusive disease.

Tourniquet Systems Pressure Infusion

LSX Low Smoke Convertor Operations Manual

Oxygen Dialflow Meter. Instructions for Use

LUNA V. User Manual. Warning

User Manual. PULSE User Manual WARNINGS

INSTRUCTION MANUAL & PARTS BREAKDOWN

Alternating Pressure / Low Air Loss Mattress System

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Resusci Anne Simulator

12V MINI AIR COMPRESSOR

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

Digital Inflation Equipment

Digital Display large color coded LED display is easy to read precise measuring shows actual cuff pressure

UNOSETION+Bipolar &BIO + Quadrupole &BIO + Quadrupole Vacuum + Sextupolar RF Slimming Machine. Model: YH-5403

NICE1 Cold + Compression Therapy System

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Instruction Manual for Configura Cushionair Portable Pump

MODEL Maverick Heavy Duty Aerosol Compressor Operator s Manual

TOURNIQUET SYSTEMS & PRESSURE INFUSION

ActiveCare+SFT and ActiveCare+DTx Patient Instructions for Use

Budget Range Operators Handbook

Pressure Regulator. Instructions for Use

SILENTAIRE TECHNOLOGY

Digital Inflation Equipment 89XDZ 89XDX. Please read this manual before carrying out any installation or service procedures.

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

INSTALLATION GUIDE Gas Rangetops

TOURNIQUET SYSTEMS & PRESSURE INFUSION

Instructions for Use (IFU) Electrical Leg- & Arm lift, model , ver. 2012

R E D I C O N T R O L S

12V Mini Air Compressor

12V AIR STATION ALL-IN-ONE

Nitrogen Supply System

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT

Vapotherm Q50 Compressor. Instructions for Use

Zenith Technical Innovations, LLC User Manual

Easy Nest Kits. Installation Suggestions

MoveRoll Conveyor Operating and Maintenance Manual

Portable Oil Lube Air Compressors

Operating Instructions Part No

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Instrument Description and Operating Instructions OXYMAT 2. Its own oxygen source

VENTI-O 2 plus. O 2 switching valve for: VENTImotion from serial number 4000 VENTIlogic from serial number 4000 VENTImotion 2

Dual Solenoid Gas Valve Installation

Oxygen Dialflow Meter. Instructions for Use

Digital Inflation Equipment 89XDA 89XDD 89XDB 89XDE.

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

VERTICAL AIR COMPRESSORS

Anodyne Therapy Professional System

*smith&nephew RENASYS GO Negative Pressure Wound

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

USER MANUAL LTH-255A Hand Piece

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

User Manual DIRECTHEALTHCARESERVICES.CO.UK

VERTICAL AIR COMPRESSORS

User Manual DIRECTHEALTHCARESERVICES.CO.UK

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

BP Controller 300 PSI

OC4000 USER'S GUIDE I O OXYGEN CONCENTRATOR FOR VETERINARY USE ONLY. by Supera Anesthesia Innovations GLOSSARY OF SYMBOLS. : ON (power switched on)

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Physiological Considerations for Compression Bandaging

OPERATION MANUAL BFX-2

AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Operating Instructions VETTER Industrial Lifting Bags 8 bar - Type IKV

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

SILENTAIRE TECHNOLOGY

Transcription:

TIMER (MIN) POWERPRESS UNIT 40 70 40 80 90 10 60 100 MIN MAX PRESSURE (mmhg) User Manual Neomedic 9601 Owens mouth Ave. #8 Chatsworth, CA 91311 Toll Free: 866-990-1168 Tel: 818-998-1023 Fax: 818-998-0277 www.air1000.com info@air1000.com Gradient Pneumatic Sequential Compressor

9. Troubleshooting If you should encounter a problem, please follow the fault finding guide below, if the fault cannot be rectified, please refer to Service. Fault Pump does not operate. Pump operates but garments will not inflate. None of the above. Check Is power switch on? Is power cord plugged in correctly? Blockage in garment supply tube. Garment not correctly fitted to pump. Pressure control set too low. Air leak in garment. Remedy Check switch. Check connections. Ensure that the tube airway is clear. Check connections. Increase pressure control. Check garemt. Replace if defective. Hint - Reduced pressure level indicates garment or connector leak None of the above. Call Service 10. Technical Description Model No: P1000 - T Supply Voltage: 1 V Supply Frequency: 60 Hz Electrical Rating: 14VA Fuse Rating: F0mAH2V Size: Length: 11.8 (0mm) Width: 8.3 (210mm) Height: 5.1 (1mm) Weight: 4.5lbs (2kg) Case Material: ABS Plastic 11

6. Warranty All Powerpress Unit shall conform to applicable specifications in effect from the invoice date to the end of the Warranty Period, and Powerpress Unit reserves the right to change such specifications at any time with or withour notice. The Warranty Period for Powerpress Unit products shall be as follows, calculated from the date of invoice: The Powerpress Unit pump is guaranteed for 12 months The Powerpress Unit garments are guaranteed for 6 months 7. Safety Warnings Electrical equipment may be hazardous if misused. The pump s rear case should only be removed by authorized technical personnel. Do not use the pump in the presence of flammable gases such as anesthetic agents. Make sure that the main power cable is positioned to avoid causing a trip or other hazard, and is clear of moving bed mechanisms or other possible entrapment areas. Contents 1. Introduction ---------------------------------------------------------------------- 4 2. Clinical Application-------------------------------------------------------------- 5 3. Clinical Treatment Guide ------------------------------------------------------ 6 4. Garment type & Size------------------------------------------------------------ 7 5. Pump Description --------------------------------------------------------------- 8 6. Warranty ------------------------------------------------------------------------- 10 7. General Safety-------------------------------------------------------------------- 10 8. Caution---------------------------------------------------------------------------- 10 9. Trouble Shooting----------------------------------------------------------------- 11 10. Technical Description----------------------------------------------------------- 11 8. Caution Electromagnetic compatibility (EMC). This product complies with the requirements of applicable EMC Standards. The use of accessories not specified by the manufacturer may result in increased emissions by, or decreased immunity of, the equipment, affecting its performance. 10 3

1. Introduction The Powerpress Unit system consists of a pneumatic pump which is light and simple to use and a 4 chamber garment. It is suitable for home use. The pump supplies air via connecting tubes to an inflatable garment allowing the application of controlled pressure to gently compress the limb. This action assists in increasing the return of blood, excess fluids, improves venous stasis and encourages the reabsorption of waste products. Compression Cycle: 36sec inflation (9sec each chamber) / 24 sec deflation Chamber 1 (Foot) = 36sec Chamber 2 (Ankle) = 27sec Chamber 3 (Calf) = 18sec Chamber 4 (Thigh) = 9sce Variable pressure output ranges from - 100 mmhg. The segments within the garments are designed to prevent ridging and ensure high patient comfort and compliance. How to use P1000 - T? Model# P1000 - T 1. Connect Tubing Hose and wear sleeves 2. Turn on Power Switch 3. Set the time you desire (0 ~ 60 min) 4. Start with low pressure and increase gradually up to you desire To Remove the Garment: Switch off the pump, disconnect the tubing from the pump by removing the tube connectors. ** We would recommend that this manual is read throughly before proceeding with treatment. Please also refer to clinical guidelines and contraindications. What is the importance of having a sequential GRADIENT Pump? It is designed to deliver a controlled amount of pressure which is greatest at the distal end (foot) of the garment and gradually decreases towards the proximal (top) end of the garment. This gradient pressure promotes better venous blood flow which in turn will control swelling, varicosities, let fatigue, and other problematic leg conditions. This improves the efficiency of the valves which return the blood to your body. The squeeze in a graduated compression garment is most firm at the bottom and reduces toward the top of the grament. This difference creates an effective pump which, working with the movement of your calf, muscle, pushes fluid and blood back up through the body. Also our gradient system prevent blood and lymph fluid for reversing to leg or arm during inflation time. Gradient: appx 7% Example: Foot 60 mmhg - Ankle 56 mmhg - Calf 52 mmhg - Thigh 48 mmhg 4 9

40 MIN 70 100 80 90 MAX 5. Pump Description 2. Clinical Application CHAMBER Intermittent Compression Therapy 1 2 1 2 3 4 side view 3 A thorough assessment of the patient should be made considering the general state of the patient and the specific characteristics of their presenting condition. The choice of system, i.e. garment and treatment regime, is to be recommended by the medical practitioner for the patient. 40 10 60 TIMER (MIN) PRESSURE (mmhg) Training and education of the patient in the use and understanding of the system will help to ensure compliance. Indications Lymphedema - primary - secondary; 4 Oedema - dependent - traumatic - secondary to stroke; 1 Timer (0 ~ 60 min) 2 Pressure Control Knob ( ~ 100 mmhg) 3 Air Tubing Hose Connector 4 Power Switch Cautions Chronic Venous Insufficiency 1. Proper application and connection to the pump is essential. 2. Garments should be removed if the patient experiences tingling, numbness or pain. Operation: The pump should be placed securely on a flat surface. Before starting the pump ensure that the garments are properly applied, the zippers are secured and the garment connecting tubes are attached to the pump outlet ports. Contraindications POWERPRESS unit should NOT be used in the following conditions: 1. Severe arteriosclerosis or other ischemic vasular diseases. 2. Known or suspected acute deep vein thrombosis. 3. Severe congestive cardiac failure. 4. Any local condition in which garments would interfere, for example: Gangrene Dermatitis Untreated, infected leg wounds Recent skin graft 8 5

3. Clinical Treatment Guide An initial pressure of 40 mmhg ( mmhg for management of lymphedema) is suggested at the commencement of treatment. It may be necessary to start at a lower level of pressure, dependent on the patient s tolerance. The pressure can be gradually increased over time, until the required pressure is reached. The upper treatment pressure range is generally 60-70 mmhg. A single treatment session is usually - 60 minutes. The above settings and timings are guidelines, and should not be used as a substitute for clinical judgement and experience. 4. Garments type & size Cytotoxicity Test, Delayed Hypersensitivity, Animal Skin Irritation Test Pass (ISO 10993-5, 10) Latex Free, Non Stretch Fabric Effective Lymphatic Drainage, Blood Circulation Design without Backflow or Gaps Seamless aircell between each chamber Waist Sleeve Available : (Regular) Cover size 35 ~ 43 ( Large) Cover size 42 ~ 49 Half Leg Sleeve (Regular) Open Arm Sleeve Open Full Leg Sleeve (Regular) 24 Open 18 (L) zip 19.5 (L) zip 28.5 (L) 28 (L) zip (L) 15 Circumference 13 15 Available Extenders size Half Leg Sleeve: 4, 6 Arm Sleeve: 4, 6 Full Leg Sleeve: 4, 6 Full Leg Full Leg Half Leg Half Leg Half Leg (XL) (R) (XL) (R) (2ch) Mid Thigh 29 24 Knee 25 24 18 Mid Calf 23 18 22 18 17 Ankle Arch (Instep) 19 15 19 15 14 17 12 18 12 11 6 7