Wicket doors. For keeping people and goods apart. Wicket door for people built into a sectional door for goods. same opening structure.

Similar documents
INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Building Code Guidelines For Home Pools

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

Building Code Guidelines For Home Pools

4 1 /8" 4 5 /8" OUTSIDE INSIDE FUNCTION TYPE DESCRIPTION K Cylinder by Turnpiece Deadbolt by inside turnpiece or outside key.

L/LV P. Lock series L = standard LV = vandlgard

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification:

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

How to Re - Key a Kwikset Pin & Tumbler Deadbolt

Pool Barrier, Fence, Gate, Closer and Alarm Requirements

Operation of Foxton Level Crossing

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2015 International Swimming Pool and Spa Code

Building Code Guidelines for Residential Pools

HLS TM 7 Series* Multipoint Hardware System. Edition 2

Swimming Pool Barrier 2015 International Swimming Pool and Spa Code

If the answer to ALL the following points (G to M) is 'Yes', the pool is not required to be surrounded by a pool fence:

Fencing your spa or swimming pool

Norton Shores Building Division 4814 Henry Street, Norton Shores, Michigan Telephone: (231) Pool Requirements

Fencing your spa or swimming pool

DEADBOLT SETS, MECHANICAL FEATURES

AMITY TWP POOL REQUIREMENTS

CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER MISSION VIEJO, CA (949)

Swimming Pools Regulation 1998

HLS 9000 Swing Door Handle Edition 4

(g)(1) Space about electric equipment.

The CompacSas BAH airlock is the ideal solution for transforming an existing door into an airlock

ROLLER SLIDE BALL BEARING

Gas Cylinder Cabinets

Pool Guide. Life Safety Inspections

FLEXI GATE WITH SMALL PET DOOR READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF GATE. KEEP INSTRUCTIONS FOR FUTURE USE.

1.0 - OPENING AND CLOSING THE DOOR

POP Product Guide. [Type text]

CHAIN LINK FENCE GATE

Town of Poughkeepsie Received: Permit # Aboveground/Inground Pool Building Permit Application

Southern Eagles Soaring

HARDWARE. Push / Pulls... A Pivots... A Hinges, Locks and Cylinders... A Handles, Locks and Accessories... A4...

Fire- & smoke- tight sliding door FST High quality for demanding architecture

Blocks must always run perpendicular (at 90 degrees) to the fence to ensure adequate stability.

Rustic Home Safety Gate

DEADLATCHES LK-2100 SERIES ASSEMBLY DETAILS LK R-RH

PSSI 6 Demarcation of Work Areas in Substations

Equipment Operating Procedure Glove Box

Read through all the steps first before working on the camera. Make sure you know what to do.

ADA Library Accessibility Checklist

2-1. CLEARING PROCEDURES

Installation, operating and maintenance Instructions for Seemag bypass level indicator

DICTATOR "DIREKT" Gate Closer

1 Sherpascopic Assembly Instructions. Sherpascopic Height Adjustable Work Platform

Name of product: Gripper for vertical façade FTV panels Types: PVF (60, 80, 100, 120, 133, 150, 172, 200 and 240 mm) INSTRUCTIONS FOR USE

PRACTICAL ADVICE ON LOCK-OFF RECYCLING/RECOVERY MACHINERY

PAS 13:2017 Safety Barriers within the Workplace

Swimming Pool Fence Guide Kodiak Iron

GRIP LOCK CHOCK (GLC)

Instruction Manual: VelectriX Foldaway

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

Healthy Hospitals Physical Activity Scan * Required

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

Circuit breakers PR 60

3M InCa Individual Cross-Connection Cabinets

i NOTE: This installation manual contains important information related to system

Name of product: Gripper of FTV panels for horizontal façades Types: PHF (60, 80, 100, 120, 133, 150, 172,200, 240) INSTRUCTIONS FOR USE

FLUID - Panic Exit Device

Inking unit. 4 4 Removing and installing the inking rollers A ZW 19 DW 16 FEAW 18 T 4.1. Roller diagram. Fig.

Barrel Assembly. Field Stripping

Interconnected Lock ANSI Grade 2 Medium Duty GF2 Series

DICTATOR "DIREKT" Gate Closer

Armed Officer's Training Manual Nomenclature and Inspection

GM-120: Container Top Lock Anchor Wand Page 1 WINSAFE CORP. GM 120 CONTAINER TOP LOCK ANCHOR WAND OPERATING INSTRUCTIONS AND MAINTENANCE

FEE SCHEDULE POOL PERMIT FEES. Refundable Security (Cash of L.C.) 1 Hot Tub, Spa, etc. $ nil 2 Above Ground Pool $ nil

Economic and Social Council

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS

Test Report. Test Report Smart Systems Limited Incorporating Smart Extrusions. Page 1 of 78

Nautique Triton Clamping Board Rack V2

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

REQUIREMENTS FOR NEW AND EXISTING DOMESTIC SWIMMING POOLS

SEA LIFE Brighton: Access Statement May 2015

BASIC MOTOR SKILLS TESTING

CompacSas BA. Comfort and design for high-security access

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2014 Florida Building Code and 2014 Florida Building Code Residential

Trilogy Theory of Operation

(1) Minimum Required. At least one entrance of sufficient area shall be provided to

BULLETIN SP b. All doors providing direct access from the home to the pool must be equipped with a self

USER MANUAL. Beach volleyball posts BEACH CHAMP ID:

3 Post Pressure Fit System Owner s Manual

WINSAFE CORP. OPERATING AND MAINTENANCE INSTRUCTIONS GM184 TOP ACCESS END LOCK ANCHOR WAND

SWIMMING POOLS/SPAS/HOT TUBS PLAN REVIEW GUIDE SHEET

Palmer township, Pennsylvania. Pool Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

TRAFFIC BOLLARDS. B2.a 114mm - Self-Righting. B2.b 114mm - Self-Righting Retractable. B2.c 114mm - Retractable. B2.d 114mm - Fixed

City of Cerritos SWIMMING POOL, SPA AND EQUIPMENT APPLICATION. (Please print or type) Name: Phone: ( )

User Guide. Tripod. flowtech 75 / 100 Tripod. Part No. S S

tubular EntrancE sets 6

Check with local zoning official for property line distance requirements.

LIGATURE RESISTANT CRESCENT HANDLE CYLINDRICAL SETS THE GOLD STANDARD FOR LIGATURE RESISTANCE + ADA COMPLIANCE

Mechanical Wind Recorder

Field Instruction. Protect Horizon Power employees and contractors from a potential hazard.

DESIGN CODE. Enterprise West Harlow London Road North Design Code 21

DEADBOLTS - SOLID BRASS

AREA VALVE SERVICE UNITS

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

Inventor Michael M. Canadav NOTICE

Transcription:

Wicket doors For keeping people and goods apart While a wicket door can be built into an ALU or ISO Alpha door, we recommend that wherever possible pedestrian traffic and goods traffic be kept apart. In other words, a permanent wicket door in the façade, separate from the sectional door, or a permanent wicket door next to the sectional door. The wicket door can be built into the sectional door, but this may affect the door s stability. It also presents limitations in terms of the door s width, height and threshold height, as a result of which the gate may not meet the current legal requirements for an emergency exit. Always discuss your plans with the local authorities so you can be sure you re choosing the right wicket door. Completely separate doors for pedestrians and goods. Separate doors for pedestrians and goods, but in the same opening structure. Wicket door for people built into a sectional door for goods. 1 2

Permanent wicket door next to the sectional door The advantage of a permanent wicket door is that the doors for pedestrians and goods are completely separate. This increases safety, ease-of-use and the stability of the sectional door. A permanent wicket door is installed in the façade next to the sectional door, where the design and panel structure of the wicket door and top panel match the structure of the sectional door, unifying them and making them both architecturally and aesthetically pleasing. Installation onto or in the opening A sectional door is always built against the interior side of the opening, so if you wish to install a permanent door in the same façade, Alpha will likewise always install it behind the opening. This has two advantages: firstly the doors are aligned, and secondly the width of the wicket door is 810 mm (1000 + 50-240 = 810 mm) for a 1,000 mm opening. The first aspect is aesthetically pleasing, while the second means a gain of 60 mm compared to when it is installed in the actual opening. If the wicket doorway is installed in the opening itself, the wicket door will stand forward from the sectional door and its width will only be 750 mm (1000-10 - 240 = 750 mm) in the same 1,000 mm opening. Choose the right door A permanent wicket door can open both inwards and outwards and you can choose between a left-hinged DIN standard door or a right-hinged DIN standard door. If the wicket door is also to be used as an emergency exit, the door must open outwards. 95 Free passage width: 810 mm DW side door: 1.000 mm 95 110 º DIN Left DIN Right DIN Right DIN Left 3 4

Wicket door built into the sectional door Integrated wicket door switch The wicket door switch, which is fitted under the safety catch, is an integrated safety device that prevents the sectional door from being operated when the wicket door is open. If you cannot install a permanent wicket door in the façade of your building, Alpha can build a wicket door into the sectional door. We offer various options for this, all of which meet the very highest structural, aesthetic and safety requirements. The built-in wicket door has a sophisticated integrated hinge system, an accurately-aligned locking system with stabilising pins and an integrated safety switch. Three choices are available for the threshold height: 22, 110 and 195 mm. Stabilising pins The wicket door is held in perfect position by the stabilising pins. This means that the door will never droop. The pins also create a more effective seal between the wicket door and the door. The magnetic contact of the wicket door switch is fitted beneath the pin. Divider A wicket door can never be positioned in the outermost parts of a sectional door, as this would affect its stability. The picture shows where the door can and cannot be installed. Wicket doors can be installed in sectional doors with a maximum door panel width of 6,000 mm. If you have a wider door, you will have to consider alternative options. Aesthetically appealing wicket door Alpha recently made significant improvements to its wicket door design, the main one being the integration of the hinge system into the sectional door. This means the fastenings are no longer visible on the exterior and the standard ALU wicket door profiles do not protrude as much. Optional extra: coloured wicket door profiles If you choose a coloured ISO or ALU sectional door with a built-in wicket door, the wicket door profiles do not have to have the same colour as the door. This option is up to you, and while some people prefer a clearly visible wicket door, others like theirs to be less conspicuous. Alpha offers you both options. 22 mm threshold To restrict the risk of tripping when evacuating the building, Alpha has created a low 22 mm threshold. Such a low threshold meets on certain conditions national directives on emergency exits. 5 6

Integrated wicket door as an emergency exit Door width and height The legislative and inspection bodies stipulate that a wicket door If you intend to use the built-in wicket which is to serve as an emergency door as an emergency exit, talk to exit must be of a minimum width the local authorities first and enquire and height, according to local about the regulations. The authorities or national regulations. The stipulate the conditions that the wicket 725-1000 mm door must meet, depending on the maximum width of an integrated wicket door is 1,000 mm and the maximum height is 2,250 mm. present in the building. As a rule, four Talk to your local authorities if aspects determine whether a wicket your wicket door is to serve as door is suitable as an emergency exit: an emergency exit. the type of lock, the door width, the door height and the threshold height. Lastly, an integrated wicket door must always open outwards, as is required 1900-2250 mm number of people working or otherwise for any door that serves as an emergency exit. 22 mm threshold To restrict the risk of tripping when evacuating the building, Alpha has created a low 22 mm threshold. Such a low threshold meets on certain conditions national directives on emergency exits. 22 Panic lock A wicket door that is to function as an emergency exit must be fitted with a panic lock. Various types of panic locks are available see page 61 for more information. A wicket door with a panic lock can always be opened using the latch on the inside, even when the deadbolt is secured. 7 8

Text Wicket door accessories and options Alpha invests heavily in creating options for the optimum integration of wicket doors into sectional doors. One of the main areas of attention is safety and ease-of-use, with special consideration given to making hinges, switches, security locks and locks as aesthetically pleasing as possible. We would also be happy to provide you with detailed individual advice on the available options for threshold heights, the direction in which the door opens, its dimensions and its position. The Alpha wicket door lock range comprises six locks: two standard locks and four panic locks (if the wicket door also functions as an emergency exit). Standard locks Lock with a handle on either side Lock with a fixed panel on the outside and a handle on the inside Panic locks Panic lock with a fixed door panel on the outside and a handle on the inside (panic function E) Panic lock with a handle on either side (split tumbler, panic function B) Panic lock with a fixed panel on the outside and push bar on the inside (panic function E) Panic lock with a handle on the outside (split tumbler) and push bar on the inside (panic function B) Depending on the situation, the fire brigade may stipulate that panic locks be installed. Panic lock, with panic function E With the type E panic lock, the door can always be locked with a key from inside. When the interior handle is turned, the latch and deadbolt are simultaneously retracted into the lock. The panic release function can only be used when there is no key in the cylinder. The latch and deadbolt can only be opened from outside with a key. The deadbolt stays in the lock after the panic function has been used. Use this lock if the wicket door is to serve as an emergency exit, but not as an entrance during the day. Coloured wicket door profiles If you choose a coloured ISO or ALU sectional door with a built-in wicket door, the wicket door profiles do not have to the same colour as the door. This is a matter of personal preference, and while some people prefer a clearly visible wicket door, others like theirs to be less conspicuous. Alpha offers you both options. Additional security locks For added safety, you can have two extra security locks fitted to the top and bottom sections of the wicket door. The same key can be used for all cylinder locks. The additional security locks have handles, so they can be opened without a key. Panic lock, with panic function B The type B panic lock is operated from inside in the same way as the type E panic lock, but there is a handle on the outside that can be locked and unlocked. This means that, if required, the door can serve as an entrance during the day. The lock works as follows: the wicket door can always be locked and unlocked from the outside with a key; when the deadbolt is locked using the key, the exterior handle will disengage and nothing will happen when it is turned. The exterior handle will remain disengaged even when the panic function has been used and the deadbolt has been retracted into the lock. The night bolt stays in the lock after the panic function has been used. The lock can only be used with the exterior handle when the key is inserted into the cylinder, which re-engages the exterior handle. 9 10 10/2013