Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

Similar documents
Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

Mode form Mode name Mode Adult/Ped Neonatal. APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü

Technical specifications for SW version 2.0.x. Mode form Mode name Mode Adult/Ped Neonatal

HAMILTON-C1 neo. Technical specifications

HAMILTON-MR1. Technical specifications HAMILTON-MR1

HAMILTON-C1. Technical specifications

HAMILTON-C3. Technical specifications HAMILTON-C3

2015 Hamilton Medical AG. All rights reserved. Printed in Switzerland.

HAMILTON-T1. Technical specifications HAMILTON-T1

Safe and Intuitive Neonatal Ventilation

Technical Data and Specifications

Oxylog 3000 plus Emergency & Transport Ventilation

INTENSIVE CARE VENTILATORS

SERVO-s v8.0 Data sheet

V8800 Ventilator System. Your healthcare, we care.

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

SERVO-air ventilator. Datasheet for system version 2.1

INTENDED USE CLASSIFICATION PHYSICAL CHARACTERISTICS

Servo UNIVERSAL ADVANCED VENTILATION PLATFORM ALL PATIENT CATEGORIES

EVE. The mobile Ventilation Concept from Emergency to Intensive Care. easy - light - smart. Ventilation

WILAmed INTENSA. Intensive Care Ventilator System

Technical Specifications

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

DATA SHEET. VENTILATION SERVO-s

Inspiration 7i Ventilator

Oxylog VE300 Emergency & Transport Ventilation

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

HAMILTON-C3. The compact high-end ventilator

Minimum size for maximum performance

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

HAMILTON-G5. The modular high-end ventilation solution

HAMILTON-T1 HAMILTON-T1. Intelligent transport ventilation

EvitaXL. Excellence throughout the ventilation process. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Panther 5 Acute Care Ventilator


SERVO-i v8.0 Data sheet

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Manufacturer Distributor in USA

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Supporting you in saving lives!

IEC C LASSIFICATIONS:

ii /04 HAMILTON MEDICAL AG HAMILTON MEDICAL, Inc.

NEONATAL/INFANT VENTILATOR

Datasheet Servo-n System version 3.0. DocID:LAB version:01 status: Approved :02 by Jennie Haag u

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Intelligent Ventilation solution from ICU to MRI

Introducing Astral. Greater freedom. Confident care. Designed efficiency

Flight Medical presents the F60

Datasheet SERVO-n. System version 2.1. This document is intended to provide information to an international audience outside of the US.

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

DATA SHEET. ANESTHESIA SYSTEM FLOW-i

Dräger Savina Sub-Acute Care Ventilation

The anaesthesia workstation focused on you

Airox Supportair Ventilator

Supporting your patients every breath

Evita V300 ICU Ventilation and Respiratory Monitoring

fabian HFO Our 4-in-1 device

Automatic Transport Ventilator

Peter Kremeier, Christian Woll. 2nd. Understanding and comparing modes of ventilation. The Kronberg List of Ventilation Modes

ASV. Adaptive Support Ventilation

SLE5000 Infant Ventilator with HFO

Understanding and comparing modes of ventilation

The anaesthesia workstation focused on you

Aespire 7100 Essential performance Compact design

INTELLiVENT -ASV. The world s first Ventilation Autopilot

Principles of mechanical ventilation. Anton van Kaam, MD, PhD Emma Children s Hospital AMC Amsterdam, The Netherlands

Oxylog 2000 plus Emergency & Transport Ventilation

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Operator s Manual Addendum

Blease900 Ventilator PATIENT CENTERED VENTILATION

DATA SHEET. VENTILATION SERVO-i INFANT HIGHLIGHTS

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Emergency Transport and Ventilation

Dräger Babylog VN500 Neonatal Open Care

evolution 3e Ventilators

AUGUST ANESTHESIA MACHINES MEDICAL PRODUCTS ANESTHESIA MACHINES. Quality System Standard applied: ISO 9001, ISO 13485

MEDUMAT Standard a MEDUMAT Standard. The Ventilation Standard for Professionals

Mechanical Ventilation

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

PATIENT SETUP QUICK REFERENCE GUIDE

Software enhancements

fabian HFO: Modular, Powerful, Versatile.

Using Common Ventilator Graphics to Provide Optimal Ventilation

Safe ventilation at rest and on the move

State-of-the-art anesthesia technology

Anesthesia Workstation

Hamilton accessories CONTENT

A9600 Anesthesia Workstation. Your healthcare, we care.

Transcription:

HAMILTN-T1 Technical specification for SW 2.2.2 Ventilation modes Mode form Mode name Mode Adult/Ped Neonatal Volume-targeted modes, adaptive pressure controlled Pressure-controlled APVcmv / (S)CMV+ Breaths are volume targeted and mandatory. ü ü APVsimv / SIMV+ Volume-targeted mandatory breaths can be alternated with pressuresupported spontaneous breaths. PCV+ All breaths, whether triggered by the patient or the ventilator, are ü ü ü ü modes pressure-controlled and mandatory. PSIMV+ Mandatory breaths are pressure controlled. Mandatory breaths can be ü ü alternated with pressure-supported spontaneous breaths. DuoPAP Mandatory breaths are pressure controlled. Spontaneous breaths can be triggered at both pressure levels. APRV Spontaneous breaths can be continuously triggered. The pressure release between the levels contributes to ventilation. SPNT Every breath is spontaneous, with or without pressure-supported ü ü spontaneous breaths. Intelligent ventilation ASV perator sets %MinVol, PEEP, and xygen. Frequency, tidal volume, ü -- pressure, and I:E ratio are based on physiological input from the patient. Noninvasive modes NIV Every breath is spontaneous. NIV-ST Every breath is spontaneous as long as the patient is breathing above the set rate. A backup rate can be set for mandatory breaths. ncpap Demand flow Nasal Continuous Positive Airway Pressure. -- ncpap-pc Breaths are pressure controlled and mandatory. -- High flow oxygen Hi Flow 2 High flow oxygen therapy. No supported breaths. therapy Standard: ü ption: Not applicable: - -

Standard configuration and options (in alphabetical order) Functions Adult/Ped Neonatal Capnography, mainstream (volumetric) and sidestream o o Communication ports: CM1 port, USB port, Nurse call o o Communication protocols: for details see Connectivity brochure o o Dynamic Lung ü -- Event log (up to 1000 events with data and time stamp) ü ü Handles for various options (jet, ambulance, or bed rail mount) o o IntelliTrig (leak compensation) ü ü Languages (English, Chinese, Croatian, Czech, Danish, Dutch, Finnish, French, German, Greek, Hungarian, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Serbian, Slovak, Spanish, Swedish, Turkish) ü ü Manual breath/prolonged inspiration ü ü NBC filter (only for HAMILTN-T1 Military) o o Nebulization, pneumatic ü -- Night Vision Goggles (NVG) option o o 2 enrichment ü ü xygen adjustable from 21% to 100% ü ü Patient group ü o Print screen ü ü Screen lock ü ü Second battery (hot-swappable) o o Speaking valve o -- Sp2 monitoring o o Standby with timer ü ü Suctioning tool ü ü Trends/Loops o o Trigger, flow and pressure selectable ü ü Vent Status (Visual representation of ventilator dependence) ü ü Standard: ü ption: o Not available: -- HAMILTN-T1

Technical performance Description Automatic expiratory base flow Specification Adult/Ped: Fixed at 3 l/min Neonatal: Fixed at 4 l/min Inspiratory pressure 0 to 60 cmh2 Maximum inspiratory flow 260 l/min (120 l/min with 100% 2) Minimum expiratory time Means of inspiratory triggering xygen mixer accuracy Tidal volume 20% of cycle time; 0.2 to 0.8 seconds Flow trigger control ± (volume fraction of 2.5% + 2.5% of actual reading) Adult/Ped.: 20 to 2000 ml Neonatal: 2 to 300 ml Preoperational checks Tightness test, Flow Sensor/2 sensor/c2 sensor calibration Brightness setting for display The range is 10% to 100% brightness. By default, Day is set to 80%; Night is set to 40%. Brightness with NVG option The range is 1 to 10. The default is 5. Standards and approvals Classification Certification Class IIb, continuously operating according to EC directive 93/42/EEC EN 60601-1:2006/A1:2013, IEC 60601-1-2:2014, ANSI/AAMI ES60601-1:2005/(R)2012, IS 80601-2-12:2011, CAN/CSA-C22.2 N. 60601-1:14, EN IS 5356-1:2015, IS 80601-2-55:2011 Declaration The HAMILTN-T1 was developed in accordance with pertinent international standards and FDA guidelines. The ventilator is manufactured within an EN IS 13485 and EN IS 9001, Council Directive 93/42/EEC, Annex II, Article 3 certified quality management system. The ventilator meets the Essential Requirements of Council Directive 93/42/EEC, Annex I. Electromagnetic compatibility According IEC 60601-2:2014 Air transport compatibility Safety Class EN1789:2007+A2:2014, EN 13718-1:2014, EN 794-1:1997 +A2:2009, MIL STD-461F, RTCA/D-160G Class II, Type B applied part (ventilator breathing system, VBS), type BF applied part C2 sensor including C2 module connector; Sp2 sensor including adapter, continuous operation according to IEC 60601-1 Pneumatic performance 2 Pressure: 2.8 to 6 bar / 41 to 87 psi Connector: DISS (CGA 1240) or NIST Air supply Integrated turbine Inspiratory outlet (To patient port) Connector: IS ID15/D22 conical Expiratory outlet (From patient port) Connector (on expiratory valve) IS ID15/D22 conical

Electrical specifications Input power 100 to 240 VAC ±10%, 50/60 Hz 12 to 28 VDC (total range 10.2 to 30.3 VD Power consumption 50 VA typical, 150 VA maximum Battery Electrical specifications: 10.8 V DC, 6.7 Ah, 72 Wh, 50 W typical, 150 W maximum Type: Normal operating time: Lithium-ion, supplied by Hamilton Medical only Typically 4 hours with one battery, 8 hours with two batteries ne battery, display brightness = 80%: 4 h ne battery, display brightness = 20%: 4.5 h Two batteries, display brightness = 80%: 8 h Two batteries, display brightness = 20%: 9.25 h Graphical patient data Graphic type/tab name ptions Waveforms Pressure, Volume, Flow, PC2 1, FC2 1, Plethysmogram 2 Intelligent panels Dynamic Lung 3, Vent Status, ASV Graph 4 Trends 1-, 6-, 12-, 24-, or 72-h 5 trend data for a selected parameter or combination of parameters Loops Pressure/Volume, Pressure/Flow, Volume/Flow, Volume/PC2 1, Volume/FC2 1 Alarms 6 Priority High priority Alarm Apnea time (s), ExpMinVol high/low (l/min), xygen high/low (%), Pressure high/low (cmh2), Flow sensor calibration needed, Exhalation obstructed, Disconnection, xygen supply failed Medium priority ftotal high/low (b/min), PetC2 high/low (mmhg), Pressure limitation (cmh2), Vt high/low (ml), Sp2 high/low, High PEEP, Loss of PEEP, Pulse high/low Low priority High Sp2, Loss of external power 1 C2 option required. 2 Sp2 option required. 3 nly for adult/pediatric patients. 4 nly in ASV mode. 5 72-hour trend not available in all markets. 6 For a complete list of alarms see the perator's Manual HAMILTN-T1

Control settings and ranges 7 Parameter (units) Range Adult/Ped Range Neonatal Apnea backup n, ff n, ff ETS (%) 5 to 80 5 to 80 Flow (l/min) 2 to 80 2 to 12 Flow trigger (l/min) 0.5 to 20 0.1 to 5 Height (cm) 30 to 250 -- Height (in) 12 to 98 -- I:E 1:9 to 4:1 1:9 to 4:1 %MinVol (%) 25 to 350 -- xygen (%) 21 to 100 21 to 100 PEEP (cmh2) 0 to 35 3 to 25 Pasvlimit (cmh2) 5 to 60 -- Pcontrol (cmh2) 5 to 60 3 to 45 Phigh APRV (cmh2) 0 to 60 0 to 45 Phigh DuoPAP (cmh2) 0 to 60 3 to 45 Pinsp (cmh2) 3 to 60 3 to 45 Plow APRV (cmh2) 0 to 35 0 to 25 Pramp (ms) 0 to 2000 0 to 600 Psupport (cmh2) 0 to 60 0 to 45 Rate (b/min) 1 to 80 1 to 80 Sex Male, Female -- Sigh n, ff -- Sp2 monitoring n, ff n, ff SpeakValve n, ff -- TI (s) 0.1 to 12 0.1 to 12 TI max (s) 0.5 to 3 0.25 to 3 Thigh APRV (s) 0.1 to 40 0.1 to 40 Thigh DuoPAP (s) 0.1 to 40 0.1 to 40 Tlow APRV (s) 0.2 to 40 0.2 to 40 Vt (ml) 20 to 2000 2 to 300 Vt/Weight (ml/kg) -- 5 to 12 Weight (kg) -- 0.2 to 30 7 Parameter settings and ranges can change depending on the mode

Monitoring parameters Parameter (units) Description Pressure AutoPEEP (cmh2) Unintended positive end-expiratory pressure PEEP/CPAP (cmh2) PEEP (positive end-expiratory pressure) and CPAP (continuous positive airway pressure) Pinsp (cmh2) Pmean (cmh2) Ppeak (cmh2) Pplateau (cmh2) Inspiratory pressure Mean airway pressure Peak airway pressure Plateau or end-inspiratory pressure Flow Flow (l/min) In ncpap mode, the average flow, updated every second. In ncpap-pc mode, the average flow during expiration, updated every breath. Insp Flow (peak) (l/min) Exp Flow (peak) ( l/min) Peak inspiratory flow, spontaneous or mandatory Peak expiratory flow Volume ExpMinVol or MinVol NIV (l/min) Expiratory minute volume MVSpont or MVSpont NIV (l/min) VTE or VTE NIV (ml) VTI (ml) VLeak (%) MVLeak (l/min) Spontaneous expiratory minute volume Expiratory tidal volume Inpiratory tidal volume Leakage percent or total minute volume leakage Leakage percent or total minute volume leakage C2 FetC2 (%) Fractional end-tidal C2 concentration PetC2 (mmhg) slopec2 (%C2/l) End-tidal C2 pressure Slope of the alveolar plateau in the PetC2 curve, indicating the volume/flow status of the lungs V alv (l/min) Vtalv (ml) V C2 (ml/min) VDaw (ml) VDaw/VTE (%) VeC2 (ml) ViC2 (ml) Alveolar minute ventilation Alveolar tidal ventilation C2 elimination Airway dead space Airway dead space fraction at the airway opening Exhaled C2 volume Inspired C2 volume Sp2 Sp2 (%) xygen saturation Pulse (1/min) Sp2/Fi2 (%) Pulse The Sp2/Fi2 ratio (%) is an approximation of the Pa2/Fi2 ratio, which, in contrast to Pa2/Fi2, can be calculated noninvasively and continuously. PI (%) PVI (%) SpC (%) SpMet (%) SpHb (g/dl or mmol/l) SpC (ml/dl) Perfusion index Pleth variability index Carboxyhaemoglobin saturation Methaemoglobin saturation Total haemoglobin xygen content HAMILTN-T1

Parameter (units) Description xygen xygen (%) xygen concentration of the delivered gas xygen consumption (l/min) The current oxygen consumption rate Time I:E Inspiratory:expiratory ratio fcontrol (b/min) fspont (b/min) ftotal (b/min) TI (s) TE (s) Mandatory breath frequency Spontaneous breathing frequency Total breathing frequency Inspiratory time Expiratory time Lung mechanics Cstat (ml/cmh2) Static compliance P0.1 (cmh2) Airway occlusion pressure PTP (cmh2*s) RCexp (s) Rinsp (cmh2 / (l/s)) RSB (1 / (l*min)) Pressure time product Expiratory time constant Inspiratory flow resistance Rapid shallow breathing index

Physical characteristics 24.5 cm (9.6 in) without handle 138 cm (54.3 in) without handle 31 cm (12.2 in) 29.8 cm (11.7 in) with handle 143.3 cm (56.4 in) with handle 63 cm (24.8 in) 22 cm (8.6 in) without handle 27 cm (10.6 in) with handle Weight 6.5 kg (14.3 lb) 18.5 kg (40.8 lb) with trolley The trolley can accommodate a maximum safe working load of 44 kg (97 lb) Dimensions Monitor Trolley accessories See graphic above Type: TFT color Size: 640 x 480 pixels, 8.4 in (134 mm) diagonal HAMILTN-H900 mounting system, optional 2 bottle holding system, optional tubing support arm Manufacturer: Hamilton Medical AG Via Crusch 8, 7402 Bonaduz, Switzerland ( +41 58 610 10 20 info@hamilton-medical.com www.hamilton-medical.com 689334.06 Specifications are subject to change without notice. Some features are options. Not all features/products are available in all markets. For all proprietary trademarks ( ) and third-party trademarks ( ) used by Hamilton Medical AG see www.hamilton-medical.com/trademarks. 2018 Hamilton Medical AG. All rights reserved. HAMILTN-T1