Introductions for a Multi-function Portable SF 6 Leaking Alarm Testing Device Based on a Two-level Configure Gas Technology

Similar documents
Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

u = Open Access Reliability Analysis and Optimization of the Ship Ballast Water System Tang Ming 1, Zhu Fa-xin 2,* and Li Yu-le 2 " ) x # m," > 0

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

AIR PRESSURE CONTROLLED MASS MEASUREMENT SYSTEM

Constant pressure air charging cascade control system based on fuzzy PID controller. Jun Zhao & Zheng Zhang

The Discussion of this exercise covers the following points:

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Neil Kane Managing Director EMT UK

Modeling Diffusion Rates of a Gas in an Enclosed Space

Coriolis Mass Flow Meter

Battery Powered Thermal Mass Flow Meters for Gases

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Gravimetric preparation of NO 2 primary reference gas mixtures at the NMISA. Tshepiso Mphamo 03 September 2012

Project Title: Pneumatic Exercise Machine

Analysis and Research of Mooring System. Jiahui Fan*

THE FUNDAMENTALS OF THE AIR SAMPLER CALIBRATION-VERIFICATION PROCESS

This test shall be carried out on all vehicles equipped with open type traction batteries.

Correction of Pressure Drop in Steam and Water System in Performance Test of Boiler

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

Membrane covered optical CO 2 sensor

APPLICATION NOTE. GC Integrated Permeation Device

67. Sectional normalization and recognization on the PV-Diagram of reciprocating compressor

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS

Petro-Chemical & Analyzer Sampling Systems

Introductory Lab: Vacuum Methods

Technical Data Sheet MF010-O-LC

A Fault Diagnosis Monitoring System of Reciprocating Pump

THE WAY THE VENTURI AND ORIFICES WORK

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

Generating Calibration Gas Standards

Research on the Sealing Detection Technology for No Leak Detection Interface Specimen Yingjun Huanga, Xudong Liaob, Guoyun Baic, Tao Chend, Miao Loue

RESEARCH OF BLOCKAGE SEGMENT DETECTION IN WATER SUPPLY PIPELINE BASED ON FLUID TRANSIENT ANALYSIS ABSTRACT

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Drilling Efficiency Utilizing Coriolis Flow Technology

Petro-Chemical & Analyzer Sampling Systems

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

Level MEASUREMENT 1/2016

Application Note AN-107

Shanghai AEAD Technology Co., Ltd Professional Manufacturer of Flow, Level, Pressure, Temperature

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

The Discussion of this exercise covers the following points:

Results of mathematical modelling the kinetics of gaseous exchange through small channels in micro dischargers

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Basketball field goal percentage prediction model research and application based on BP neural network

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

Irrigation &Hydraulics Department lb / ft to kg/lit.

Journal of Chemical and Pharmaceutical Research, 2014, 6(3): Research Article

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Hydraulic pressure balance Model CPB5800

Gas density monitor With integrated transmitter Model GDM-100-TI

Manual of SF6 Comprehensive Tester

CHEM 355 EXPERIMENT 7. Viscosity of gases: Estimation of molecular diameter

Design Features. General Description

Chapter 13 Gases, Vapors, Liquids, and Solids

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Modal Analysis of Propulsion Shafting of a 48,000 tons Bulk Carrier

You should be able to: Describe Equipment Barometer Manometer. 5.1 Pressure Read and outline 5.1 Define Barometer

Using the UltraRAE. Firmware 2.35

SAFETY DEMONSTRATION TESTS ON HTR-10

THERMODYNAMICS OF A GAS PHASE REACTION: DISSOCIATION OF N 2 O 4

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Truck-mounted Mass Flow Metering for LPG Delivery

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

FTIR Users Group Meeting FTIR development

Heat Pump Connections and Interior Piping

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Mitos Fluika Pressure and Vacuum Pumps Datasheet

Gas Diluter Portable Gas Dilution System User s Manual

In Vivo Scientific, LLC INSTRUCTION MANUAL

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Dead-weight tester High-pressure version Model CPB3800HP

Thermo Scientific Model 146i Principle of Operation

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

Model Description

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Transcription:

Research Journal of Mathematics and Statistics 6(4): 45-49, 2014 ISSN: 2042-2024, e-issn: 2040-7505 Maxwell Scientific Organization, 2014 Submitted: April 08, 2014 Accepted: June 08, 2014 Published: November 25, 2014 Introductions for a Multi-function Portable SF 6 Leaking Alarm Testing Device Based on a Two-level Configure Gas Technology Bao-jun Qu and Jian-wei Zhang School of Mechanical Engineering, Shandong University of Technology, Zibo, China Abstract: In this study, we make a study of a new two-level configure gas technology. This technology can expend the configure gas device s dilution ratio and combined with inner set baffled spiral cast to achieve a full-sacle configure gas of SF 6 and air. Further to make the SF 6 leaking alarm testing device to be not only a multi-function portable device but also have the advantages like compact structure, light weight, large dilution ratio, high accuracy, degree of automation and so on. And this device can solve the situation of SF 6 leaking alarm device can t calibrate conveniently in indoor workplace, such as electric power system GIS obviously. Keywords: Leaking alarm, SF 6, test INTRODUCTION The sulfur hexafluoride is widely used in power system because of its good performance in insulation and arc extinction. With the developing of electric power technology and wide application of GIS electrical equipments, electrical room with SF 6 equipments, but a part of SF 6 will be separated with the effects of high-voltage arc or high temperature, the products are always highly toxic. And when the switches or the devices indoor for SF 6 are leaking, it will pose serious life-threatening risk to the workers who are indoor. So it needs SF 6 leaking alarm testing device to test the levels of SF 6 and O 2. And there are a great variety of the SF 6 gas leaking alarms with different detection principle, but most of their sensitivity, accuracy or stability can not be effectively guaranteed at present. A random sample of SF 6 leaking alarm testing devices which are installed in two cities power network system, we find that about 70% can t work normally or relatively great detection error. So they can t test the levels of SF 6 and O 2 effectively, hidden trouble in safety. For the moment, the reports about SF 6 leaking alarm testing device are less both at home and abroad. And the internal power network system majority uses traditional configure gas technology to check the SF 6 leaking alarm testing device. At present the SF 6 gas leaking alarms have problems in testing: first, most of companies don t take any testing action for the device, don t familiar with its performs of real time monitoring. Second, at the scene there are a great variety devices with different detection principle, include of electrochemical technology, electric breakdown technology, infrared spectroscopy absorb technology and so on, it bring problems for devices testing because of the lack of SF 6 leaking alarm device testing technology s versatility. Third, part of companies use the standard gases to test devices, the rate is slowly. And the varying s standard gases cylinders needed for scene testing also bring problems for testing and operating. This study is mainly to solve the testing problems above-mentioned. Via studying on a two-level configure gas technology, expending the configure gas device s dilution ratio to achieve a full-sacle configure gas of SF 6 and air. Further to get an alarm testing device for SF 6 leaking with compact structure, light weight, large dilution ratio, high accuracy and degree of automation by using liquid SF 6 and air pump as gas source. TWO-LEVEL DYNAMIC CONFIGURE GAS TECHNOLOGY It needs compounding multi-component and various s mixture gases to test the alarm testing device for SF 6 leaking. So we need selecting the suitable configure gas methods to ensure the inspections work can be carried out better. At present, the common methods to configure gas standard material include both static and dynamic at home and abroad. The static methods include gravimetric method, differential pressure gas preparation method, gas bag method and so on. The basic principle of gravimetric method is weight hybrid, mixing different weight and various gases. Differential pressure gas preparation method relies on the ideal Dalton law, filling with the species gases and dilute gas into a assumed constant and sealed steel cylinder. Gas bag method is pressing the quantitative tube s raw material into gas bag, diluting to a certain volume, kneading the gas bag by Corresponding Author: Bao-jun Qu, School of Mechanical Engineering, Shandong University of Technology, Zibo, China 45

Table 1: Several air flow devices parameters contrast table US ALICAT Japan KOFLOC US AALBORG Type MC series 8500 series GFC17S series Effective control range 0.5%-100% FS 2%-100% FS 1%-100% FS Control precision ±(0.8% reading data+0.2%fs) ±1.5%FS ±1.0%FS Repeatability ±0.2% ±0.5% ±0.2% Responding time 0.1-0.3S 1-2S 1-2S Working temperature range -10 C to +50 C 0 C to +50 C 5 C to 50 C Inner set gas species 20 common gases and 10 mixed gases, automatically switch Single calibration gas Single calibration gas hand to mix well-distributed. These methods are tedious operation, rigorous technology steps. It s hard to get a certain accurate. And the short stable time led the limitation of using (Du and Deng, 2008). The dynamic method is making a known raw gas with diluted gas into the mixer to mix at a constant ratio incessantly. So we can compound and supply a certain standard gas incessantly. The dynamic method is suitable for our device because of it can both long time supply massive standard gas and compound various mixed gas (Zhou and Yi, 2008). At the pressure of one standard atmosphere, SF 6 s relative density is 6. 16 g/cm 3 in the gaseous and 1400 g/cm 3 in the liquid. Therefore, when we use 2 L the liquid SF 6 is roughly equivalent to 454 L in the gaseous. This ensure that you can have a long-term compounding gas with 2 L liquid SF 6 without aerating frequently or a 10 L s steel cylinder, so we get a portable device and the device needs a full-sacle configure gas of SF 6 and air. Thus it needs two-level dynamic configure gas system, achieve twice dilutions for raw gas, to ensure control precision. Considering SF 6 leaking alarm devices have a larger structural differences and various installing positions, this study select the dynamic method combined with gas bag method, compounding standard gas by dynamic configure gas system. And test the gas in the sealed soft bag which is install onto the alarm device. The dynamic method uses the high precision quality flow controller to control the species gases flow. Some common air quality flow controllers parameters are compared in Table 1. From Table 1 we can get that US ALICAT s MC flow controller has a higher control precision and more suitable for configurating the trace level mixed gas conditions. Meanwhile the 20 common gases and 10 mixed gases, automatically switch bring great convenience to compounding multi-component mixture gases for portable SF 6 leaking alarm testing device. Due to air quality flow controllers calibration gases are pure gases when they are in factories, so they will have indicator value errors while the first time to dilute the raw gases be the multicomponent gases via the devices, needed correcting. Under the standard status, test the different gases flow need a linear parameter transformation and it s general 46 decided by the absolute viscosity of gas. This parameter can be calculated as follows: Q og = Q 1 (η 1 /η og ) In formula: Q 1 = The flow that flow controller display η 1 = Calibrating gas viscosity under the standard status Q og = The actual flow of multi-component gases η og = The multi-component gas viscosity under the standard status (Alicat Company, 2005) If consider the influence of pressure and temperature, the multi-component gas formula is: Q og = Q 1 (η 1 /η og ) (298. 15/273+t) (p/101. 325) In formula: t = The actual temperature p = The actual pressure We can get that pressure and temperature have very small influence on the compounded of standard gases, so we can neglect them. And we have prove it through experiments under many times, different conditions. The viscosity calculation formula of multicomponent gases under the standard status is: η = η 1 (ω 1 /ω T )+ η 2 (ω 2 /ω T )+ +η n (ω n /ω T ) In formula: ω 1 ω n is the corresponding gas flow; ω T is flow of mixture gases; η 1 η n is the corresponding gas viscosity. MULTI-FUNCTION PROTABLE SF 6 LEAKING ALARM TESTING DEVICE S WORKING PRINCIPLE This device include gas source, two-level configure gas system, gas mixed system and so on. It can be automatically switch according to the dilution ratio. So when the dilution ratio is lower it takes the first order gas distribution mode to achieve a fast configuring and when the ratio is greater than 100:1 it takes the second order gas distribution mode to achieve the low s automatically configuring. Moreover, it

Fig. 1: Multi-function portable alarm testing device for SF 6 leaking working principle s figure; 1: Raw gas steel cylinder; 2: Dilution gas steel cylinder; 3: The first pressure reducing valve; 4: The second pressure reducing valve; 5: The first electromagnetic valve; 6: The second electromagnetic valve; 7: The third electromagnetic valve; 8: The 4 th electromagnetic valve; 9: The 5 th electromagnetic valve; 10: The 6th electromagnetic valve; 11: The first quality flow controller; 12: The second quality flow controller; 13: The third quality flow controller; 14: The 4th quality flow controller; 15: Check valve; 16: Relief valve; 17: The first mixer; 18: The second mixer 19: The first buffer tank; 20: The second buffer tank; 21: Pressure transmitter; 22: Air cleaner; 23: Microminiature air pump; 24: Check cavity can test the of O 2 because of the alarm device s O 2 content is usually 18%. Therefore, take the standard SF 6 as dilute gas, air as raw gas (air has about 21% O 2 under the standard status) to configurate the 15-21% standard O 2 gas can completely meet the O 2 s testing requirements, instead of carrying steel cylinder. It s working principle as Fig. 1. It s working principle are: The gas configuration of the first order cylinder: Switch on the raw gas steel cylinder and regulated to a suitable gas pressure by the first pressure reducing valve; switch on the dilution gas steel cylinder and regulated to a suitable gas pressure by the second pressure reducing valve; switch on the 5 th and the third electromagnetic valve, the third and the 4 th quality flow controller, the diluted raw gas and the dilution gas into check cavity after mixing in the second mixer, completing the gas configuration of the first order cylinder. The gas configuration of the second order cylinder: Switch on the raw gas steel cylinder and regulated to a suitable gas pressure by the first pressure reducing valve; switch on the dilution gas steel cylinder and regulated to a suitable gas pressure by the second pressure reducing valve; switch on the first and the second electromagnetic valve, the first and the second quality flow controller, the diluted raw gas and the dilution gas into the first buffer tank after mixing in the first mixer, completing the primary gas distribution. 47 Fig. 2: The inner set baffle spiral cast mixer s internal structure images The relief valve switch on automatically when the primary distribution get the pressure of mixed gas are above the relief s setting pressure, then excreting the redundant mixed gas to keep the pressure, or carry the second order distribute. Switch on the third electromagnetic valve and the 4th quality flow controller at same time, the mixed gas in the first buffer tank and the diluted gas enter into the check cavity through the second mixer. Then, complete the gas configuration of the second order cylinder. This device can also take the air pump mode: switch off the second pressure reducing valve and use check valve to shut the pathway of diluted gas steel cylinder. Switch on micro miniature air pump and the 4th electromagnetic valve, the air go through the second buffer tank at a constant pressure under the pressure transmitter s control; to be instead of steel cylinder, reduce the real time labor intensity. The gas mixer is the core of the gas mixing uniform or not and the key of the dynamic system can mix various gases unform quickly. Its mixed performance determines the accuracy and stabilization of compounding gases. The first mixer and the second mixer in Fig. 2 use the inner set baffle cast mixer with 17 inner set baffle spiral cast, in fluid s process,

Table 2: The performance test results for 3 kinds of mixers Structural pattern Inner set baffled spiral cast Spiral cast Through type SO 2 /SF 6 19.8 19.5 19.2 is 20 SO 2 /SF 6 1.8 1.6 1.4 is 2 H 2 S/SF 6 20.2 19.6 19.5 is 20 H 2 S/SF 6 1.8 1.7 1.5 is 2 CO/SF 6 100.5 100.8 101.1 is 100 CO/SF 6 is 10 9.6 9.4 9.1 Table 3: The determination results of SF 6 gas leaking alarm calibration device s accuracy The SF 6 s (%) setting flow L (ml/min) SF 6 s setting () SF 6 s actual () The errors of gas distribution (%) 50.0 2000.0 100.0 98.5 1.500 50.0 2000.0 200.0 197.0 1.500 50.0 2000.0 300.0 297.0 1.000 50.0 2000.0 400.0 395.5 1.125 50.0 2000.0 500.0 503.5-0.700 50.0 2000.0 600.0 602.0-0.333 50.0 2000.0 700.0 697.0 0.429 50.0 2000.0 800.0 797.0 0.375 50.0 2000.0 900.0 903.0-0.333 50.0 2000.0 1000.0 1008.0-0.800 50.0 2000.0 1100.0 1095.0 0.455 50.0 2000.0 1200.0 1193.0 0.583 50.0 2000.0 1300.0 1292.0 0.615 50.0 2000.0 1400.0 1392.0 0.571 50.0 2000.0 1500.0 1512.0-0.800 50.0 2000.0 1600.0 1590.0 0.625 50.0 2000.0 1700.0 1706.0-0.353 50.0 2000.0 1800.0 1790.0 0.556 50.0 2000.0 1900.0 1890.0 0.526 50.0 2000.0 2000.0 2004.0-0.200 50.0 2000.0 2500.0 2488.0 0.480 50.0 2000.0 3000.0 2994.0 0.200 50.0 1500.0 4000.0 3985.0 0.375 50.0 1500.0 5000.0 4970.0 0.600 50.0 1000.0 6000.0 6005.0-0.083 50.0 1000.0 7000.0 6976.0 0.343 50.0 1000.0 8000.0 7930.0 0.875 50.0 1000.0 9000.0 9014.0-0.156 50.0 1000.0 10000.0 9941.5 0.585 PERFORMANCE TEST The sample gas of SF 6 s is 50%, the diluted gas is clean air and configurating the of SF 6 standard gas from 100 to 10000, the flow of SF 6 standard gas is 2000 ml/min. Use the SF 6 chromatograph to test the actual, observe the relative errors between the setting and the actual, the determination results are showed in Table 3. From the determination results, we can get that the flow control precision is less than 0. 9%; the uncertainty of gas distribution is less than 1. 5%. This suggests that the dynamic system is large dilution ratio, good stability and high accuracy. CONCLUSION At present, the reports about the SF 6 gas leaking alarms testing technology are comparative little and have not found a multi-function portable alarm testing device for SF 6 leaking with two-level configure gas technology. This device has these advantages compared with other test system: This device can use SF 6 and air pump as the gas source, get the requisite various s SF 6 standard gas through the two-level configure gas technology to avoid bringing massive SF 6 standard gas and diluted gas steel cylinder. This device can take both air pump model and air bottle model as the air source. The clean air is provided by air pump in air pump model and provided by exteriorization air bottle in air bottle model. This device uses the dynamic two-level configure gas method, can be used when the amount of standard gas is larger, the dilution ratio is higher, the configure gas s time is longer or have a big difference in molecular weight. This device use a special mixer with 17 inner set separators, can configure gas with high precision, low effectively. REFERENCES segmentated times increase in power series, formed 2 17 times cutting, shear, rotation and mixed again, to get a good dispersion and a fully mix. The performance test for the mixers of inner set baffled spiral cast, spiral cast and through type and the results are showed in Table 2. In Table 2, we can get that use the spiral cast mixer and spiral cast mixer can urge each gas molecular intercollision s affects. For the air uniform of both large and small, to achieve a stable mixing, the performance of mixing gas: inner set baffled spiral cast>spiral cast mixer>through type mixer. 48 Alicat Company, 2005. The Operation Manual of Gas Quality Flow Controller. (Accessed on 10/26/2005 Rev.4). Du, L.M. and Z.P. Deng, 2008. Study on dynamic volumetric system of uniform mixed different gas. Chinese Hydraulic. Pneum., 3: 29-30. Li, C.Y. and Q.F. Du, 2003. Application of automated gas divider in the standard gases analysis. Low Temp. Specialty Gases, 121(15). Zhao, C. and C.D. Wang, 2007. Study on the volumetric method using a multi-component dynamic gas confection system. Sci. Technol. Rev., 25(5), Sum No. 227.

Zhao, J.H., H.Y. Lan, Z.J. Chen, Z. Li and C.W. Zhao, 2008. Research on the dynamic multiple gases Distributing system based on mass flow controller. Process Automat. Instrum., 29(2): 44-48. Zhou, Y.H. and X.Z. Yi, 2008. Development of the dynamic gas-mixing equipment based on single chip microcomputer. Microcomput. Inform., (Accessed on: Vol. 24 of the first 8-2) Zhou, Z.Y., J.P. Liang and L.J. Gai, 2004. Study of diffusion tube calibration gases preparation and dynamic volumetric method. Acta Metrologicasinica, 25(1). Note: Provide missing information of following references which are available in the reference list but not mentioned anywhere in the text. Zhao and Wang (2007), Li and Du (2003), Zhou et al. (2004) and Zhao et al. (2008). 49