LPG, LEG, LNG tankers & Chemical and Product tankers

Similar documents
Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

CONTROL and INSTRUMENTATION

Annual Inspection and Calibration Checklist VAF Oilcon MK-6(M) MEPC.108(49) Page 1 of 5

Minimum standard of competence in advanced training for liquefied gas tanker cargo operations (STCW Reg V/1-2)

SLOP RECEPTION AND PROCESSING FACILITIES

TEC-0461 To whom it may concern Date 25 June 2002

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

AUTOMATIC HOSE TEST UNIT, TYPE SPU

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

17. CARGO MEASUREMENT AND CALCULATION

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

IE011: Process Control & Instrumentation Technology

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

OPERATING PROCEDURES

RAM 4021 Operation Manual

GUIDANCE IN-SERVICE INSPECTION PROCEDURES

Session One: A Practical Approach to Managing Safety Critical Equipment and Systems in Process Plants

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MANUAL GAS MANIFOLDS

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MOL LNG Transport (Europe) Ltd File: 02 Checklists 6 pages Rev. No. 1 Loading Plan Part Two (2) (Line UP) Loading Plan Part Two (2) (Line Up)

RAM 4021-DPX Operation Manual

IE068: Process Instrumentation Technology

RAM Operation Manual

IE039: Practical Process Instrumentation & Automatic Control

Orifice Plate Flow Meter

Improving distillation tower operation

ROV Development ROV Function. ROV Crew Navigation IRATECH SUB SYSTEMS 2010

INTERNATIONAL MARITIME ORGANIZATION

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

Cold-acclimatised pipelines

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

Radar, Ultrasonic and RF Level Transmitters

Commandant United States Coast Guard

Periodical surveys of cargo installations on ships carrying liquefied gases in bulk

How to specify a product. Process Sensors and Mechanical Instruments

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

RULES PUBLICATION NO. 119/P

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

American made since 1954

200 PSI FAST-FILL AIR SOURCE KIT

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.]

FIRE FIGHTING Address : Phone : Fax : Url : Mail :

RHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Yokogawa Systems and PCI Training

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

EZY Chek Systems CERTIFICATION EXAM COVER SHEET

CPE562 Chemical Process Control HOMEWORK #1 PROCESS & INSTRUMENTATION DIAGRAM

Installing a Probe. Typical Installation

Installation of Ballast Water Management Systems

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

CSA Sample Draw Aspirator Adapter Operator s Manual

GAS TANKER COMMITTEE #4

Special Documentation Proline Promass 80, 83

Valve test benches. Systems overview

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

PROCESS MONITORING AND CONTROL

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

We re Going Global. Vessel Loss Control. Technical Notes #36

Vehicle- or rack-mounted liquefied gas meters, pump supplied

+Port: LOADPORT Voyage No.: 03 Date: 01-Aug-2016 No. Description Remarks [ ]

SINGLE VALVE WITH LOW-FLOW BYPASS

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

RESOLUTION MSC.397(95) (adopted on 11 June 2015) AMENDMENTS TO PART A OF THE SEAFARERS' TRAINING, CERTIFICATION AND WATCHKEEPING (STCW) CODE

Automatic Isokinetic Sampler. ST5 Evo

Field Instrumentation Training Strategy

UTAS EH&S INSTRUCTION No. 036 June 2012 Revision No. 3. Purging of Flammable Gas Equipment and/or Piping (Explosion Hazard)

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

2. Application This "Guidelines" applies to all ships. 3. General Requirements for the Maintenance and Inspection of Fire-protection Systems and Appli

REGASIFICATION VESSELS

200 PSI HIGH-FLOW AIR SOURCE KIT

Tanker Familiarisation IMO Model Course Chapter 1-9

Chapter 2 Preparations for Tank Cleaning Work

Commandant United States Coast Guard

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

PARTS & SERVICE. regulator (new) for NGW/ GBW applications. Rev. 02/2018 Id.No. DOK50026

GLD TM Ballast Water Treatment System

Measurement And Control Appreciation

API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks

GAS FUELLED ENGINE INSTALLATIONS

HEALTH AND SAFETY MANUAL

The Discussion of this exercise covers the following points:

STCW Code Table A-V/1-1-1 Specification of minimum standard of competence in basic training for oil and chemical tanker cargo operations

Flow controller Type ED/CCB311 Instruction manual

GLD TM Ballast Water Treatment System

Valve actuation at the world s largest flow metering calibration facility

2007 Gas-Lift Workshop

Transcription:

marine Welcome to Nordan Marine A/S Nordan Marine Calibration Service: LPG, LEG, LNG tankers & Chemical and Product tankers Calibration of level controls Calibration of pressure and temperature alarms Calibration of level alarms and level gauges Calibration of DP transmitters Fixed gas detector systems Providing the certificate approved by Japanese Customs - The World s Best Alternative - 2

Nordan Marine - Calibration Service Nordan Marine staff of qualified Calibration Engineers have years of experience with calibration of measuring equipment on a variety of different vessels. We offer our clients a one-company solution to your needs for service of cargo pumps, booster pumps, safety relief valves and calibration of measuring equipment. Annual calibration of measuring equipment It is essential that your vessels measuring equipment is calibrated and functioning correctly. In particular, in relation to the cargo control system, it is essential that gauges and transmitters can be trusted. It is therefore required by class, and others, that this equipment be calibrated yearly and that this work is documented by certificates. Our trained Instrumentation Engineers will issue a certificate on all equipment calibrated onboard your vessel. We bring our own certified calibration tools and devices ensuring you that you can rely on your gauges and transmitters after we have completed our work. 32

Calibration of Cargo Measuring Equipment Nordan Marine offers: Calibration of level gauges Calibration of pressure and temperature gauges Calibration of level alarms Calibration of pressure and temperature alarms Calibration of pressure and temperature transmitters Calibration of DP transmitters Calibration of pressure switches Calibration of SPRT, PT 100, PT 1000 Calibration of TC sensors Calibration of thermocouples Calibration of display units for temperature, pressure and level gauges Service on fixed gas detection systems Oil content meter Intert gas system Ship reference equipment 24 Hrs, worldwide service We offer a 24 hours service 365 days a year. Our Electronic Engineers fly on short notice and on in- expensive seaman s tickets. 24-hr service Tel.: +45 9840 2440 Service Email: service@nordanmarine.com 73

Nordan Marine - Calibration Service Calibration, repair and service on level gauges We are able to perform service, repair and calibration on all most all level gauges, both local and remote mechanical and electrical gauges and indicators. Each maker has its own special guidelines and procedures to follow which all the Service Engineers at Nordan Marine s calibration department are trained to perform. Nordan Marine also provides the vessel with a new certificate on every device after completion. Calibration, repair and service on pressure gauges Calibration on pressure gauges, sensors, transmitters and switches between -1 to 350 bar. Pressure gauges can be either a mechanical or an electrical device. At Nordan Marine, we can supply quality pressure gauges, sensors, transmitters and switches, we are also offering the solution to simply calibrate and adjust the existing devices. The calibration procedure can vary depending on the customer s choice; normally, we will use our own calibrated equipment to measure and produce a pressure in 5 points across the measuring range. When we deliver the certificate all values from the test such as deviation, serial number and calibration date will appear. 4

Calibration of Cargo Measuring Equipment Calibration, repair and service on temperature gauges Calibration on temperature gauges, sensors, transmitters and switches between -80 to 650 C, just like pressure gauges, all temperature gauges can be either mechanical or electrical devices. Calibration of both mechanical and electrical temperature devices is performed in two steps: Electrical: Step 1: First, we disconnect the sensor and measure different values to clarify the sensors condition, and then, we calibrate the sensor and reconnect it to its respective terminal. Step 2: Now, we calibrate the loop from the sensor to the digital display. All values from the two steps together with deviation, the serial number and a new calibration date will appear on the new certificate. Mechanical: Step 1: We pull out the sensor from the thermos wells and then we test in liquid at four different temperatures to see how the sensor and gauge reacts all over the measuring range. If the device has a too big deviation, we calibrate the device and test it again. Step 2: When the device works as it should, we will mount the sensor back to place. All values from the two steps together with the deviation, a serial number and a new calibration date will appear on the new certificate. 5

Nordan Marine - Calibration Service Calibration, repair and service on alarm systems We test, repair and calibrate alarms for pressure, temperature and level gauges. We service complete alarms systems from different makers, and with our close contact to them, we can deliver spare parts on short notice. When our Calibration Engineers have completed a job, we will issue a certificate for the actual system calibrated and serviced. Certificates Calibration Certificates After completion of the calibration works our engineers will hand over a certificate of all equipment calibrated and upon return to the office complete a detailed report for all work done. Spare parts Nordan Marine has stock of various equipment such as gauges, transmitters, PT 10 sensors and thermocouples most commonly used. Further, we have daily contacts with manufactures, which provides us with the ability to supply needed parts on a short basis. Approved by Japanese Customs Authorities Nordan Marine can get calibration certificates approved directly from the Japanese Customs Authorities. Our Calibration Engineers are educated in the electronic field and can perform both electronic and mechanical calibration. They work regularly on many types of equipment such as: ENRAF Musasino Heinrichs Whessoe Krohne 6

Calibration of Cargo Measuring Equipment Pre- docking Inspection / Assessment As a service to our clients, Nordan Marine offers a free pre-docking inspection service. We will bear the Service Engineer cost. Only direct cost such as flight tickets-hotel and living expenses will be invoiced to the client. The inspection / assessment will normally take place in a discharge port 3 to 4 month before the vessel will go to dry dock. A detailed report will be worked out, outlining the performance of the cargo pumps, booster pumps, safety valves, cooling compressors and instrumentations. This allows our clients better preparation of the next docking. Service and overhaul of cargo pumps, booster pumps and safety relief valves Besides our calibration service, Nordan Marine offers overhaul and repair on the following equipment: Deep well cargo pumps Booster pumps Ballast pumps Safety relief valves FRAMO cargo pumps See our other brochures for more information, or contact us directly. 47

Contact us: Denmark Nordan Marine A/S Industrivej 11 9900 Frederikshavn Denmark 1 Phone: +45 9840 2440 (24 hrs) Fax: +45 9840 2441 E-mail: sales@nordanmarine.com service@nordanmarine.com www.nordanmarine.com