Study of the IBF of Double/Triple THGEM

Similar documents
Design and Construction of a GEM-TPC Prototype for R&D Purposes

Effects of the electric field on the electron drift velocity in a double-gem detector in different gas mixtures

Performance of a triple-gem detector for high rate charged particle triggering

TPC Report. D. Karlen T2K ND280m meeting December 7, 2004 Rome

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

485 Annubar Primary Flow Element Installation Effects

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

A Study of Spatial Resolution of GEM TPC with Ar-CF 4 -ic 4 H 10 Gas Mixtures

Numerical Tools for LCLS-II Vacuum Systems

GasSense NDIR User Manual

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

3. Structure static test. 4. Solar Sail Material Test. 5. Conclusion

Development of small, easy to build and low gas consumming timing RPCs

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

Relative Dosimetry. Photons

Influence of HALO and drain-extension doping gradients on transistor performance

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

EUV Resist Performance under High Stray Light Levels: an Interference Lithography Study

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

Analysis of RPC Performance with Different Gas Mixture

3. DYMAX Lightguides. Diameters Distance vs. Intensity Multiple Poles Connections

Vacuum Simulations of the KATRIN Experiment

MODULAR FLEXIBLE PERFORATING SYSTEM. PERFORATING-EXPLOSIVE OPERATIONS RISK MITIGATION AND EFFICIENCY IMPROVEMENT RIPS-17-18

Surfing Interconnect

Compact4Pool. pool filters. For spas and swimming pools by up to 20,000 litres Pump, filter, pre-filter and UV-C in one. Advantages of Compact4pool:

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

5mm Infrared LED EAILP05RDDB1

Automatic Isokinetic Sampler. ST5 Evo

Corrosion problems in seawater pump caissons. Practical solutions.

Karl Suss MJB4 Mask Aligner

Understanding How the Appearance of Optical Fiber Splices Relates to Splice Quality

Long term stability tests of INO RPC prototypes

TOTAL-IONIZING-DOSE RESPONSE OF 65 nm MOSFETS IRRADIATED TO ULTRA- HIGH DOSES. GIULIO BORGHELLO

The Gas Attenuator of FLASH

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

1)! DO NOT PROCEED BEYOND THIS MARK

Mitos Fluika Pressure and Vacuum Pumps Datasheet

SoLID Heavy Gas Cherenkov Update

Turbine dynamics and power curve performance

The Transition Radiation Detector of the AMS-02 Experiment

9A5N Solid State CW Paddle

Mass Spec will not Autotune

AMS 6916 Board mount pressure sensor with ratiometric analog output

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

The Principles of Vacuum Technology

A Reliable and Tracer Gas Independent Leak Detector for Food Packages

Fabry Perot / PDV Comparison. May 24, 2007

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

ISR workflow Tests status

C-Flow Coriolis Mass Flow Meters

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

sorting solutions osx separator series

Applications of ELCIRC at LNEC

Currents measurements in the coast of Montevideo, Uruguay

TUV Low Pressure Mercury

Experience with the ZEUS central tracking detector

TECHNICAL DESCRIPTION

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

Improving distillation tower operation

Approved by Principal Investigator Date: Approved by Super User: Date:

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Kicker types for In- and Ejection in the damping Rings of TESLA

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3

Stop Chasing & Start Managing Density

Porter Analytical & Industrial Products

Quadruple mass spectrometers (transducer type)

Engineering and Design Rules for Hopper Scales

Next Generation Quartz Pressure Gauges

Installation and Operation Manual

Practical approach and problems in in-situ RGA calibration

HIGH ACCURACY MULTI-GAS MONITORING USING AUTOMATED SELF- CALIBRATION

THROUGH-HOLE PACKAGING REELS, TUBES, AMMO PACKS & TAPING SPECIFICATIONS

Product Technical Bulletin #48

Status update of Beam pipe. S. Tanaka KEK

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Clinical Implementation of the IPEM 2003 Code of Practice for Electron Dosimetry

Cover Page for Lab Report Group Portion. Pump Performance

Detecting sound wave of bubbles produced in a boiling liquid

Safety Manual VEGAVIB series 60

Monitor Unit Calculations Part 2. Calculation of machine setting. Collimator setting

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

ECE520 VLSI Design. Lecture 9: Design Rules. Payman Zarkesh-Ha

Total Ionization Dose (TID) Test Results of the RH1028MW Ultralow Noise Precision High Speed Operational Low Dose Rate (LDR)

Sail Through Engineering Post-Workshop Activity

Alice TPC Review Short Summary

Pressure Sensitive Paint (PSP) / Temperature Sensitive Paint (TSP) Part 1

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Quantitative study of sniffer leak rate and pressure drop leak rate of liquid nitrogen panels of SST-1 tokamak

Ultrasonic level transmitter and indicator

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

Diagnostics for Liquid Meters Do they only tell us what we already know? Terry Cousins - CEESI

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Transcription:

Study of the IBF of Double/Triple THGEM Qian Liu, Carlos, Hongbang LIU, Zhengyang Heng NED 2012, Mianyang 1

Outline PMT/Gas PMT THGEM introduction IBF of DTHGEM study Triple THGEM study Combined analysis Conclusion 2

Photo Multiplier Tube (PMT) PMT 1. High Gain 2. Excellent time resolution (ps) 3. Output channel limited 4. Magnetic field deflected 5. Expensive Gas PMT 1. High Gain 2. Good time resolution (ns) 3. Multi-Channel output 4. Magnetic field tolerated 5. Radiation hard 6. Relatively cheap 7. Compact 3

Principal of photo cathode coating Transparent Reflect In both methods, ions will be accelerated in electric field and 4 hit on photo cathode.

Thicker Gas Electron Multiplier (THGEM) Standard GEM Developed from 1997 by F. Sauli (CERN) Typical parameters: 50 m Kapton Ø60 m holes 100-200 m pitch THGEM F. Sauli NIM A 433 (1997) 531 Developed from 2004 by A. Breskin (Israel, CERN) : Parameters: Thickness t = 0.2~0.5 mm Hole diameter d = 0.2-1 mm Pitch a = 0.5-1 mm Cu G-10 Chechik et al. NIM A535 (2004) 303 ROBUST! Easy produced 5

Experiment setup Different pattern designs of THGEM 6

Test procedure 1. We tested them with aligned/not aligned configuration. D T1 B1 2. The current of each layer are measured and the following parameters are calculated: T2 B2 A 7

D Almost 0 negligible T1 B1 T2 B2 A 8

IBF measurement (T1/Tot) for Conf. B/C * aligned not-aligned * aligned not-aligned For aligned DTHGEM, the IBF is not related to the transfer field. For not-aligned DTHGEM, the IBF decreases while transfer field increases. 9

IBF measurement for conf. A(T1/Tot) 1.2 kv/cm induction field 2.0 kv/cm induction field The IBF decreases dramatically while transfer field increases. Errors are calculated using the error propagation function. 10

IBF analysis for conf. C (aligned) D T1 0% 1398 32.3% 78 1.7% 0 kv/cm B1-38 0.87% 221 5.1% 0% 1.2kV/cm T2-34 0.78% 2588 59.7% B2-2709 62.5% 0% 1.2kV/cm A -1553 35.8% 11

IBF analysis for conf. A Gain was pushed to the second THGEM, so the electrons and ions from the first layer of THGEM are almost negligible. 0% 14.2% ~0% 0 kv/cm ~0% 9.8% 0% ~0% 76.2% 1.2kV/cm 77.3% 0% 1.2kV/cm 22.7% 12

IBF analysis for conf. A Double the transfer field, the ions will hit B1 instead of drifting to T1. But the ions from bottom are still mainly collected by T2. 0% 3.1% ~0% 0 kv/cm ~0% 27.5% 0% ~0% 68.5% 2.4kV/cm 79.2% 0% 1.2kV/cm 20.7% 13

Triple THGEM configuration D 7.6 mm 2.5 mm 2.5 mm 2.0 mm 1 2 3 A 700 V 1575 V 1575 V 400 V Conf. B is used for triple THGEM. The middle one is not aligned to the others two. 14

Scan the top THGEM HV To push the gain to the bottom two, TOP THGEM high voltage is set to 700V. Fit quality Gain The quality of the fit starts to get worse at 800V/0.4cm. The gain shows lower than 900V/0.4cm, the single photon is dominated. Starting at 900V/0.4cm, the multiple photons are dominated, and the top THGEM starts to work. 15

UV light stability Motivation: during DTHGEM test, the current of anode decreased when induction field increased. One probability is the UV light intensity decreased. Method: Applying 6.5 V to UV light, turn it on for 1 min which is approximately the same time period for IBF measurement, then turn it off for another 1 or 2 minutes. The light source should be quite stable during the IBF measurement! 16

UV light vs. PA Meter D 1 2 LED=5.5V G=3774.3±159.7 3 A PA The noise from PA contribution can be avoid by chose a different fit range. LED=6.0V G=3895.2±41.5 17

UV light vs. PA Meter The anode current can be estimate by: LED Thres./fC Rate/Hz Gain I_Anode I_Anode I_B3 5.5 1.12 550 3774.3-2.12-3.0-7 6.0 1.12 6975 3895.2-26.22-37.7-88 6.5 1.12 27947 4172.2-99.87-165 -385 2.0 kv/cm induction field A/(A+B3)=30% Measured from PA Meter 18

Gain 2D scan for not-aligned TTHGEM Gain doesn t change much. But with larger bottom transfer field, the gain is smaller. Numbers are gain value. The test has been done with LED=5.5V 19

IBF 2D scan for not-aligned TTHGEM Numbers are IBF% 20

IBF vs. LED for not-aligned TTHGEM The top transfer field = 3.0kV/cm The bottom transfer field = 2.0kV/cm The error are calculated by error propagation. By increasing LED voltage, the uncertainty of IBF decreases because the current is bigger and more stable The IBF 2D scan result for 5.5V LED can be found in the backup slices. 21

discussion The not-aligned conf. can decrease 93.3% IBF, while only lose 17% gain. Question followed: 1. will this not-aligned conf. decrease the max counting rate? 2. will this not-aligned conf. decrease the efficiency? Due to the PA meter, IBF is measured for LED=6.5 V; To have single photon-electron signals, gain is measured for LED=5.5V If we assume the gain will not change much, and the LED intensity will be the same if the same voltage is applied, we can define the relative efficiency by: The R here can be get from gain MCA files, or by solving the function above. 22

Efficiency of aligned 2D distribution The result gives a same behavior as not-aligned configuration. The result is got from MCA. 23

MC Simulation Ions diffusion is much less than electrons which proves this mis-aligned configuration is effective to the IBF. 24

What ve done in GUCAS 25

Conclusion 1. 93% of the IBF can be reduced by not-aligned configuration while the gain only decreased 17%. 2. The ions will mainly collected (60%~70%) by the layer where those ions are generated. So working under the minimum gain of the first layer THGEM is also important. 26

谢谢 ~ 27