COBRA. Compact Bailout Rebreathing Apparatus

Similar documents
Confidence Under Pressure

Rebreather Training Council Standard

Centre of Excellence for Subsea Safety

Hyperbaric Testing Testing and trials for the subsea industry. jfdglobal.com

Self Propelled Hyperbaric Lifeboats. 12, 18 & 24-man

Commercial Diving Products and Services. jfdglobal.com

Rebreather Training Council Standard

11. TDI Semi-Closed Circuit Rebreather Diver Course, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH

COMPETENCIES FOR SPECIFIC TASK AREAS UNDER THE SCIENTIFIC AND ARCHAEOLOGICAL DIVING ACoP

Manufacturers of Quality Diving Equipment

RESA Standards V1.0 16/08/18

RESA STANDARDS V2.0 15/12/2018

Semi-Closed (SC-) Rebreather Advanced SC Rebreather STANDARDS AND REQUIREMENTS TRAINING PROGRAM ( VERSION 2000/00 )

17. TDI Air Diluent Closed Circuit Rebreather Diver Course, Unit Specific- Inspiration / Evolution, KISS, Optima, Megalodon

20. Semi-Closed Circuit Rebreather Instructor, Unit Specific- DOLPHIN, RAY, Atlantis, SUBMATIX ST100 & AZIMUTH

Syllabus Number: 3.B.35 / BOD n. 188 ( ) CMAS CCR Diver diluent air/nitrox Training Program Minimum Training Program Content

24. Basic Closed Circuit Rebreather Decompression Procedures Instructor - Unit Specific

29. Air Diluent Closed Circuit Rebreather Diver, Unit Specific

Dräger FGT 5400 Diving Equipment

Overview. Prerequisites for the course. What will be covered throughout the course - Modules - Assembly & Pre/Post Care - Diving Skills

Rebreather Training Council Standard

ACUC ASSISTANT INSTRUCTOR - Currículum and Standards Ref: acuc-st-asi Oct 2003

20. TDI Advanced Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

Special Purpose Specification NFQ Level 6. Surface Supplied Diving Operations. Draft for Consultation. Teideal as Gaeilge. Level 6.

38. Rebreather Full Cave Diver

19. TDI Mixed Gas Closed Circuit Rebreather, Unit Specific, Ambient Pressure Inspiration & Evolution, Diver Course

Design Of Semi-Closed Rebreathers To Minimize Variations In Circuit Oxygen Levels

NHC Training. Passionate about improving subsea safety worldwide

Candidate Name: Member Number: Q4. When teaching defensively, what is probably the single best advice an instructor can follow?

Surface Supplied Mixed Gas Diving Operations

British Sub-Aqua Club Tel: +44 (0) Fax: +44 (0) bsac.com

Drass. 700 Series Surface Diving System

PHOTO: JONAS DAHM / DEEP SEA PRODUCTIONS VERSATILE REBREATHERS FOR SKILLED DIVERS

COVER PHOTO: JONAS DAHM / DEEP SEA PRODUCTIONS VERSATILE REBREATHERS HANDCRAFTED IN DENMARK

Common Discrepancies Uncovered on ADCI Diving Contractor & Training Program Audits

revo air diluent course procedures

Confédération Mondiale des Activités Subaquatiques. World Underwater Federation MIXED GAS DIVING STANDARDS

European Diving Technology Committee EDTC

We ve worked for almost a hundred years to keep professionals breathing in hazardous environments

10. TDI Advanced Trimix Instructor Course

7. TDI Advanced Wreck Diver Course

31. Helitrox Diluent Closed Circuit Rebreather Diver Decompression Procedures Course, Unit Specific-

Trifecta Systems. Cryogenic Equipment for High Performance Gas Supply. Trifecta Product Catalog

Annex 1 to Decision 2009/007/R

Demystification of Nitrox, Understanding Mixtures

DEPICFTRA:1SPORIATiO^

3. Contaminated Water Ops

Trifecta High-Pressure Systems

Delivering Excellence is our BusInesS

8. TDI Trimix Diver Course

SOP. Working in Confined Spaces

98695A01 - THE CONCEPT OF THE DIVATOR FAMILY

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

M-06 Nitrogen Generator (Nitrogen Making Machine)

31. Air Diluent Closed Circuit Rebreather Decompression Procedures Diver, Unit Specific-

Diving Standards. Health & Safety Authority March 2017

SPHL-R. A part of the James Fisher Hyperbaric Rescue Service. (Self Propelled Hyperbaric Lifeboat Recovery) Subsea UK Expo 2016

2016 OFFSHORE TRAINING AND ASSESSMENT SERVICES

Interspiro has over 60 years of experience in the design of Breathing Apparatus for demanding firefighting and diving conditions

BULLETIN A Training and Education Update for PADI Members Worldwide

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

Mine Rescue Certification Training Standard

UK Contractors Group Mobile Elevating Work Platforms Good Practice Toolkit June June 2015 Page 1 of 16

9. Extended Range Instructor

US NAVY DIVING PROGRAM: DIVING TO 300 FT DEPTHS USING SURFACE-SUPPLIED AND SATURATION FLY-AWAY DIVING SYSTEMS. Introduction

TDI Standards and Procedures. Part 2: TDI Diver Standards

Upon successful completion of the course the instructor trainer must:

1. TDI Helitrox Diver Course

Reclaim Basic Set Up

This document is a preview generated by EVS

NOAA DIVING PROGRAM MINIMUM STANDARD FOR DECOMPRESSION DIVING USING OPEN-CIRCUIT SCUBA EQUIPMENT

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Recommendations on Checking Anaesthesia Delivery Systems

Australian/New Zealand Standard

Australian/New Zealand Standard

Working in Gas Hazard Areas

Understanding CCR - In Depth

DIVING SERVICES UK COMMERCIAL & RESCUE DIVING CONTRACTORS

Dräger Saver PP Compressed Air Escape

Respiratory protective devices

Course Length: The course is four sessions for a total of 32 hours.

SHERWOOD PRO OWNER S MANUAL

CONFIDENCE UNDER PRESSURE

MSA Latchways Solutions for Industry

SHERWOOD OWNER S MANUAL

ASPEC Engineering HSE Management System. Work Instruction. 1 Objective. 2 Working in confined spaces. 2.1 What is a confined space?

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

Altitude Diver Standard Version (2010/00)

c) Loss of product or replacement when units are being serviced All of these are factors that need to be considered by the user.

SEMI-SUB AND JACK UP DRILL RIGS SPECIALIST CLEANING SERVICES & EQUIPMENT RENTAL SOLUTIONS

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

Any active TDI Helitrox Instructor who has been approved by TDI Headquarters Training Department

ANSI / ASSE Z88.2 American National Standard Practices for Respiratory Protection (1992 rev. versus 2015 rev.)

1. Unlimited, so long as adequate facility, supplies and time are provided to ensure comprehensive and complete training of subject matter

Dräger OCEANUS 140 Mobile Compressor

An Overview of Confined Space Rescue Course Objectives

Course Objectives. An Overview of Confined Space Rescue

SATURATION SYSTEM II COMPONENTS

Offshore Diving Supervisor Certification Scheme

9. Extended Range Diver

Transcription:

COBRA Compact Bailout Rebreathing Apparatus

INTRODUCTION The new COBRA (Compact Bailout Rebreathing Apparatus) set has been developed to provide a simple, highly reliable breathing system which offers a diver up to 45 minutes of fully independent breathing gas in the event of an emergency. COBRA is designed with the intent that a diver should be allowed to focus on the task in hand, knowing they can rely upon their emergency life support system in the event of a primary failure. Easy to operate and maintain, this semi-closed rebreather is completely mechanical and relies on no complex electronics for its operation. COBRA is robust and reliable and has been designed to perform under the arduous conditions experienced in saturation diving such as extreme pressures, volatile gas mixtures and harsh environmental conditions. DIVER SAFETY JFD pioneers state-of-the-art, customer specified commercial diving equipment which drives the continual improvement of safety standards for diving operations. COBRA ensures all divers operating in any conditions have access to a greatly extended emergency breathing gas supply that affords them the best possible chance of survival if things go wrong. 45 449 450 451 up to 45 minutes endurance up to 450 msw semi-closed rebreather 2 Introduction

COMPLIANCE COBRA incorporates existing Divex technology which has been extensively proven in the military diving world. BS EN14143:2013 COBRA meets the required safety, health and environmental standards to comply with EU legislation to the standard EN14143 making it the only fully certified deep diving emergency breathing system in the world. NORSOK U-101 COBRA also meets the relevant requirements of NORSOK U-101 and is able to satisfy NORSOK emergency breathing gas duration guidelines to 300msw. Norwegian guidelines stipulate that a diver must have a minimum of 10 minutes emergency breathing gas calculated at a breathing rate of 62.5l/m which renders open circuit bailout methods non-conforming at depths greater than 56m. Duration (minutes) Duration based on 10 minutes at 62.5lt/min with remainder at 40lt/min Compliance 3

WHY CHOOSE COBRA? For the past twenty years, JFD has produced the Divex SLS (Secondary Life Support) rebreather bailout system for commercial divers. The system has been adopted worldwide, offering divers a greatly extended duration over an open circuit bailout cylinder. However, there is now recognition that even greater duration is required as diving operations advance to depths below 200m and larger diving systems are installed containing extended excursion umbilicals. Scrubber hot-water jacket to ensure high CO 2 scrubbing performance on actuation Positive pressure when rebreather offline to maintain breathing loop integrity Compatibility with KMDSI/Ultrajewel helmets Can be mechanically switched on and off by the diver as a pre-dive check Single turn activation SLS Mk4 COBRA Weight out of water: 26kgs in water: neutral Dimensions width: 398mm height: 570mm depth: 171mm Gas Mixture Heliox (dependant on depth) Counterlungs completely encapsulated on the diver s back Easy fill scrubber system for fast, simple change out of sodalime Composite or steel twin cylinders easily accessible for charging Operating Temperature seawater -1 O C to +34 O C freshwater +1 O C to +34 O C Storage Temperature -30 O C to +70 O C (fully dried) Increased positive pressure feed to allow more rapid descent Safety indicator rotowink providing additional assurance of system positive pressure and hence integrity 4 Why Choose COBRA?

CAPABILITY JFD has a well-established history in the development of advanced commercial and defence rebreathers, and has developed some of the most innovative systems which significantly improve diver safety within the saturation diving industry. Capability 5

TESTING COBRA has been subject to rigorous testing throughout the development process assuring its capability and performance. Work of Breathing tested using a breathing simulator Operational parameters of breathing apparatus tested using a rig Environmental testing including gas mixtures, depth, temperature and wave form Conditioning testing including cleaning, disinfection, temperature and seawater resistance Functional requirements testing Hydrostatic imbalance Endurance testing Breathing circuit testing Inspired partial pressure oxygen levels Inspired gas temperature Helmet and body harness testing Practical performance testing LOW WORK OF BREATHING Low Work of Breathing Single Turn Activation SINGLE TURN ACTIVATION A single turn activation on and off means divers can test the set before leaving the stage as part of their pre-dive checks - providing a significant safety advantage over previous parachute systems. 6 Training

TRAINING JFD offers a full range of training courses to suit a variety of roles and requirements. It is strongly recommended that all personnel undergo familiarisation training as a basic introduction and understanding of the equipment. JFD also offers more advanced courses specifically relevant for supervisors and technicians. Courses run from the JFD facility in Aberdeen benefit from access to an indoor training tank and custom built lecture facilities however courses can be scheduled anywhere in the world. 1 & 2 DAY COURSES FAMILIARISATION 1 Day This one day course combines theoretical familiarisation elements with a practical training session designed for divers and supervisors who will be using the equipment on a day-to-day basis. Delegates will be given the opportunity to use the equipment within the safe and controlled confines of the JFD dive tank, as well as taking part in a more in-depth classroom session learning about technical features and functions. MAINTENANCE 2 Days This two day course has been specifically designed to provide technicians with detailed theory and practical sessions giving them the skills needed to competently build and maintain the system. Upon successful completion of the course, each student is issued with a certificate of training which is valid for 3 years. Renewal courses are available on request assuring that standards can be easily maintained. Testing 7

Aberdeen Bremen Cape Town China Glasgow Newcastle Perth Portsmouth Singapore Stirling Sydney Vaxholm Virginia jfdglobal.com enquiries@jfdglobal.com DOC-BRO-2 R0 Copyright JFD Limited 2018