8122H AXION Drench / Safety Shower

Similar documents
8320 AXION MSR COMBINATION EYE / FACE WASH & DRENCH SHOWER

Model TWBS.SH Tempered Water Blending System

Model 9201E Tempered Water Blending System

Model Portable Eyewash

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

Emergency Eyewash & Shower Testing Program

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Installation. S19-300T (top supply) S19-300B (bottom supply)

Laboratory Safety Guideline Emergency Eyewash and Safety Showers

DB 61 Dolphin TMV3 Integrated Thermostatic Mixing Valve

ANSI Z Compliance Checklist

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

Emergency Shower & Eyewash. Training Guide

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Bermad Pressure Reducing. Model: 42T

V43 Pressure Actuated Water Regulating Valve

1 Exam Prep. Tabs and Highlights

EMERGENCY EYEWASH STATIONS & SAFETY SHOWERS GUIDELINES

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Blowdown vessels Meeting the requirements of HSE PM60

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

EMERGENCY EYEWASH & SHOWERS

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

Horizontal Bladder Tanks

EYE WASH STATIONS & SAFETY SHOWERS GUIDELINES

Vertical Bladder Tanks

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Vertical and Horizontal Bladder Tanks

Service and installation must be performed by a trained/experienced service technician.

FIREFIGHTING EQUIPMENT

Air Amplifiers & SYSTEMS

NGP-250/500 Nitrogen Generator Quick Start Guide

CUT OFF TOOL MODEL: CAT113

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Model MTB-ASME Vertical Bladder Tanks

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Model MTB-ASME Horizontal Bladder Tanks

High Performance BSP Dial Up Pattern Pressure Reducing Valve

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Model MTB-ASME Vertical Bladder Tanks

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Wet pipe low flow foam/water system

ANSI / ISEA Z Compliance Checklist

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

TECHNICAL DATA. Q = C v P S

DS06D,G Dial Set Pressure Regulating Valve

Smart Water Application Technologies (SWAT) TM

G92 Series BASOTROL Automatic Pilot Gas Valve

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Combination Air Valve

Dri-Line Mk3 Monnier Compressed Air Drain Trap

SECTION BUTTERFLY VALVES

Instructions for Installation, Operating and Maintenance

Two-port valves, male threaded, PN25

TECHNICAL DATA CAUTION

Anti-flood device Model B-1

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

OXYGEN and SYSTEM OXY

D05 Pressure Regulating Valves

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

GRAVEL/ FILTERS IRRIGATION EQUIPMENT LTD. SERIES APPLICATIONS

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

SRV66 Sanitary Pressure Reducing Valve

2-port seat valves PN25 with externally threaded connections

San Antonio Water System Standard Specifications for Construction ITEM NO. 841 HYDROSTATIC TESTING OPERATIONS

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Bermad Model:

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

ASSE International Product (Seal) Listing Program

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL DATA Q= C. Table 1 - Specifications

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

FIREFIGHTING EQUIPMENT

Forged stainless steel ASTM A182 F316

BGA158 Series CE Approved Class A Shutoff Gas Valve

SANP ACTING RELAYS YT-520/525/530 SERIES

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Pressure Independent Control Series

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

LOCK UP VALVES YT-400/405/430/435 SERIES

Gas Countertop Hot Plates

Installation and Use Manual

TECHNICAL DATA OBSOLETE

Transcription:

www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)57 579 066 8H AXION Drench / Safety Shower "G 3.8 kg No CH Z358. Horizontal wall installation AXION MSR Greens ABS shower head (SP89) Stay open valve (SP60) Universal Emergency shower sign (SP77) Stainless steel push rod (SP00) Test tag (SP70) PNR UK Ltd 8a Harris Business Park, Stoke Prior, Bromsgrove, B60 4DJ www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)57 579 066 Co. Reg. 306776 V.A.T. Reg. No. 488 0643 6

www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)57 579 066 PNR UK Ltd 8a Harris Business Park, Stoke Prior, Bromsgrove, B60 4DJ www.pnr.co.uk spraynozzles@pnr.co.uk +44(0)57 579 066 Co. Reg. 306776 V.A.T. Reg. No. 488 0643 6

HAWS DRINKING FAUCET COMPANY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HAWS AG Bachweg 3 CH-340 Burgdorf Switzerland www.haws.ch HAWS Corporation P.O.Box 070 455 Kleppe Lane Sparks,Nevada 8943/USA www.hawsco.com Model 8H Axion NOTE TO INSTALLER: please leave this information with maintenance department. " G 558 00 Supply 68 No. 0804/3 R400 00 678 3 53 30 Top View TÜV tested SCALE :5 THESE DIMENSIONS MAY VARY +/-,7mm (/") Legally-stipukated dimensions: 3 There must be a minimum clearance radius of 400 mm / ' 3 3/4" (not counting operating controls) between a vertical line running down from the shower head and the nearest obstacle (wall, vertical inlet pipe or similar). Height above floor level: 00mm - 300mm (6' 0 /" - 7' 6 /"). The operating controls must be no higher than 750mm (5' 9") above floor level (while conforming to local regulations). Free access to the emergency body shower 8H Axion must be guaranteed at all times. The operator is responsible for the observance of this requirement. Jeannine Ruf 8H Axion.0.0 /4

HAWS DRINKING FAUCET COMPANY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS HAWS AG Bachweg 3 CH-340 Burgdorf Switzerland www.haws.ch HAWS Corporation P.O.Box 070 455 Kleppe Lane Sparks,Nevada 8943/USA www.hawsco.com Model 8H Axion No. 0804/3 Shower location: The emergency body shower 8H Axion must be installed in the vicinity of potential danger zones. It must be highly visible and easily accessible. Connection conduit: You are recommended to use a " G conduit, capable of withstanding pressure of - 6 BAR (30-90PSI). The use of an inlet filter designed to prevent the entry of standards of suspendede particles and other impurities is also recommended. Water quality: Emergency body showers requiere a supply of drinking water conforming to European standards or their equivalents in other countries. Water temperature: The requiered water temperature should be determined by the user. The accepted ideal range is 5-35 C / 60-95 F (but please ensure conformity with local regulations). Volume flow: A minimum flow rate of 60 litres / 5,8 US gallons per minute must be maintained. The emergency body shower must be capable of delivering this amount of water for at least 5 minutes. Connection to plumbing system: The inlet consists of a " G female-threaded conduit. Regular inspection: The emergency body shower 8H Axion should be inspected at weekly intervals. The inspection tag should be dated and signed after each check. Problem. No flow. Insufficient flow of water TROUBLESHOOTING Repair-checklist Check the main shutoff valve. Check the line pressure. This should be at least BAR / 30PSI (dynamic). Jeannine Ruf 8H Axion.0.0 /4

A 3 4 PARTS BREAKDOWN ITEM PART NU. DESCRIPTION SP89 SP60 Axion shower head Valve assembly 3 SP77 Shower sign 4 5 SP00 SP70 Pull rod Test tag A B B C C 4 3 D 5 D E E PARTS BREAKDOWN F TÜV tested WHEN ORDERING PARTS PLEASE SPECIFY YOUR MODEL NUMBER APPROVALS DRAWN Jeannine Ruf CHECKED DATE 6.07.00 BACHWEG 3 T +4 (0)34 40 60 00 CH340 BURGDORF F +4 (0)34 40 60 0 SWITZERLAND TITLE www.haws.ch info@haws.ch 8H Axion MATERIAL Jeannine Ruf 6.07.00 ZONE REV DESCRIPTION ECN DATE BY REVISED Jeannine Ruf.0.0 REVISIONS DRAW-NO. THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR HEREWITH IS NOT TO BE REPRODUCED, USED, OR DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT ECN NO. SIZE PART NO. A4 THE PERMISSION OF HAWS CORPORATION. SCALE :0 3 4 0804/3 REV. SHEET 4 OF 4 F