Innovation Report. Physiological and Biomechanical Testing of EasyPedal Pedal Prototypes. Jan 2012

Similar documents
Myths and Science in Cycling

Available online at Prediction of energy efficient pedal forces in cycling using musculoskeletal simulation models

A Novel Gear-shifting Strategy Used on Smart Bicycles

JEPonline Journal of Exercise Physiologyonline

Journal of Human Sport and Exercise E-ISSN: Universidad de Alicante España

Assessment of an International Breaststroke Swimmer Using a Race Readiness Test

Changes in a Top-Level Soccer Referee s Training, Match Activities, and Physiology Over an 8-Year Period: A Case Study

Physiological Assessment: Summary Report 11 December 2011

Monitoring of performance an training in rowers

The running economy difference between running barefoot and running shod

University of Canberra. This thesis is available in print format from the University of Canberra Library.

Duration of exercise and anaerobic energy share. Assesment of anaerobic capabilities in elite athletes. Evaluation of anaerobic capabilities

Summary of Preliminary Report on the Performance Enhancements provided by ROTOR Q-Rings Foreword

ABSTRACT THE INFLUENCE OF BODY COMPOSITION ON CADENCE EFFICIENCY IN COMPETITIVE CYCLISTS. by Tate Bross Devlin

INTERACTION OF STEP LENGTH AND STEP RATE DURING SPRINT RUNNING

Steeplechase Hurdle Economy, Mechanics, and Performance

The Influence of Elliptical Chainrings on 10 km Cycling Time Trial Performance

Joint Torque Evaluation of Lower Limbs in Bicycle Pedaling

Personal Bicycle Fitting Report Rider Information

Biomechanical analysis of the medalists in the 10,000 metres at the 2007 World Championships in Athletics

INVESTIGATION OF POWER OUTPUT ON A NOVEL BICYCLE DRIVE IN COMPARISON WITH THE COMMON BICYCLE DRIVE

12. Laboratory testing

WHITE PAPER THE SCIENCE BEHIND NON-CIRCULAR CHAINRINGS

GROUND REACTION FORCE DOMINANT VERSUS NON-DOMINANT SINGLE LEG STEP OFF

Validity and Reproducibility of the Garmin Vector Power Meter When Compared to the SRM Device

HPA Power Transmission. Everardo Uribe

COMPARISON OF BIOMECHANICAL DATA OF A SPRINT CYCLIST IN THE VELODROME AND IN THE LABORATORY

Field Testing the Upright Versus the Aero Cycling Position

PEDALING ANALYSIS Pedaling Analysis monitor the power output variations coordinated action the smoothness of the pedaling

The Optimal Downhill Slope for Acute Overspeed Running

Chapter I examines the anthropometric and physiological factors that. determine success in sport. More specifically it discusses the somatotype

EFFECTS OF CHAINRING DESIGN ON PERFORMANCE IN COMPETITIVE CYCLISTS

Influence of Angular Velocity of Pedaling on the Accuracy of the Measurement of Cyclist Power

Training Program. Definitions. Preparation for Training

Coaching Applications The Effect of Intermittent Hypoxic Exposure plus Sea Level Swimming Training on Anaerobic Swimming Performance

Specificity of training is perhaps the most significant

The effect of deliberate practice on the technique of national calibre swimmers

A Pilot Study on Electromyographic Analysis of Single and Double Revolution Jumps in Figure Skating

INFLUENCE OF PEDALING TECHNIQUE ON METABOLIC EFFICIENCY IN ELITE CYCLISTS

A Re-Examination of Running Energetics in Average and Elite Distance Runners

Know your movement. Enhance your performance through biomechanics with Q RINGS & 2INpower

External Feedback Does Not Affect Running Pace in Recreational Runners

OXYGEN POWER By Jack Daniels, Jimmy Gilbert, 1979

Validation of a Step Test in Children Ages 7-11

Stride Frequency, Body Fat Percentage, and the Amount of Knee Flexion Affect the Race Time of Male Cross Country Runners

Vector Rope Trainer Cardiovascular Program Fitness Level: GENERAL

Analysis of energy systems in Greco-Roman and freestyle wrestlers participated in 2015 and 2016 world championships

A New Approach to Modeling Vertical Stiffness in Heel-Toe Distance Runners

Cycling. Active Cyclist. 8 weeks. Cycling training with Kéo Power. Endurance cycling, Intervals

Influence of crank length on cycle ergometry performance of well-trained female cross-country mountain bike athletes

The Influence of Load Carrying Modes on Gait variables of Healthy Indian Women

Human Ergometry. Bhavesh Bawankule M Tech Final year Mechanical Department Priyadarshini College of Engineering Nagpur, India

Anaerobic and aerobic contributions to 800 m and 8 km season bests

TRAINING PLAN WATTBIKE.COM BASE PLAN

Pedaling effectiveness. Jon Iriberri & Javier Sola WKO4

RELATION BETWEEN MAXIMAL ANAEROBIC POWER OUTPUT AND TESTS ON ROWING ERGOMETER

Congress Science and Cycling 29 & 30 june 2016 Caen. Théo OUVRARD, Julien Pinot, Alain GROSLAMBERT, Fred GRAPPE

60bbm and less 60-50bbm 50-30bbm 30-20bbm 20-10bbm (incorporates a significant aerobic component)

An intervention program on Portuguese Paracanoe athletes: a multidisciplinary approach

The Singapore Copyright Act applies to the use of this document.

Effect of Basic Endurance Training on the Level of Maximum Oxygen Consumption and the Recorded Achievement for Junior Swimmers 400m Freestyle Stroke

DIFFERENCES IN PHYSICAL FITNESS IN KUMITE AND KATA PERFORMANCE BETWEEN FEMALE KARATE ATHLETES

Walking Simulator Mechanism

Products for life and performance

APPLICATION OF FILMING AND MOTION ANALYSIS IN MOVEMENT STUDIES. Xie Wei Sports Medicine and Research Center, Singapore Sports Council, Singapore

Explanation slides series in article Longitudinal ( ) study in 5 Dutch Recreation Sports Groups. by Jan A. Vos, PhD, Exercise Physiologist

Relationship Between Common. Measures of Training Stress and. Maximum Mean Power During. Road Cycling Races

SQUASH CANADA TECHNICAL AND FITNESS TESTING PROTOCOL MANUAL

Changes in Relative Exercise Intensity during a Two Hour Endurance Race Using a Tandem-Bicycle for Exercise

VISUOMOTOR CONTROL OF STRAIGHT AND BREAKING GOLF PUTTS 1

Gait Analyser. Description of Walking Performance

NEURAL AND SENSORY APPLICATIONS OF INTERVENTION IN IMPROVING TECHNIQUE AT HIGH SPEED AND RACE PACE ASCTA CONFERENCE - BROADBEACH MAY 2014

SPRINTING CHARACTERISTICS OF WOMEN S 100 METER FINALS AT THE IAAF WORLD CHAMPIONSHOPS DAEGU 2011

Training Program using critical speed exercises and their impact on some Physiological and Physical variables of handball Players during the Match

RESPIRATORY REGULATION DURING EXERCISE

ARE YOU A SLOW- OR A FAST-TWITCH RUNNER?

PVDOMICS: Cardiopulmonary Exercise Testing (CPET) Training

Effect of Pedaling Technique on Mechanical Effectiveness and Efficiency in Cyclists

CHARACTERISTICS OF DIFFERENCES IN ENERGY EXPENDITURE AND HEART RATE DURING INDOOR AND OUTDOOR FIELD HOCKEY MATCHES

Variability of pacing in marathon distance running

Energy Systems and Growth

Ground Forces Impact on Release of Rotational Shot Put Technique

THEORY OF TRAINING, THEORETICAL CONSIDERATIONS WOMEN S RACE WALKING

Relationship Between Glide Speed and Olympic Cross-Country Ski Performance

Gender Differences and Biomechanics in the 3000m Steeplechase Water Jump

REVBOX MK7.0 INSTRUCTION MANUAL

1. Zinn, L. (2009). Zinn and the Art of Road Bike Maintenance, 3rd Ed. Boulder, CO: Velo Press.

Triathlon cycle-run transition: seated versus alternating seated and standing cycling

Combining effects in human walking: load, speed and gradient

1500m Training HOUSTON FRANKS MISSISSIPPI STATE UNIVERISTY

Journal of Exercise Physiologyonline (JEPonline)

The effect of the Gravity-Loading Countermeasure Skinsuit (GLCS) upon aerobic exercise performance

Available online at ScienceDirect. Procedia Engineering 112 (2015 )

Using Hexoskin Wearable Technology to Obtain Body Metrics During Trail Hiking

Languages. Heart rate. Vo2

Exploring the relationship between Heart Rate (HR) and Ventilation Rate (R) in humans.

Optimization of an off-road bicycle with four-bar linkage rear suspension

SWIMMING SCIENCE BULLETIN

#10 Work Physiology. By : Dewi Hardiningtyas, ST., MT., MBA. Industrial Engineering Dept. University of Brawijaya

Abstract. Ulrik Röijezon, PhD and Paul Arden, MCCI

Transcription:

Innovation Report Physiological and Biomechanical Testing of EasyPedal Pedal Prototypes Jan 2012 Report: Data collection: Dr. Michael Hanlon and Dr. Rodney Kennedy Sport and Exercise Research Institute, University of Ulster Dane Dunlop (Research Assistant) University of Ulster Research facilitated by:

Contents Page 1. Introduction 2 2. Methods 3 2.1 Main study methods 3 2.2 Case study 1 methods 5 2.3 Case study 2 methods 6 3. Results 7 3.1 Main study results 7 3.2 Case study 1 results 7 3.2 Case study 2 results 8 4. Conclusions 9 5. References 10 1

1. Introduction Cyclists are continuously pursuing new training methods and strategies in an attempt to improve performance [1]. To date most research has focused primarily on metabolic factors such maximal oxygen consumption (VO 2max ) and blood lactate thresholds as these have been repeatedly shown to predict performance [2, 3]. Nonetheless, an often overlooked and arguably more important factor is cycling economy, which is defined as the submaximal oxygen demand per unit of body mass required to perform a given task [4]. The economical transfer of power from the human body to mechanical power output driving the bicycle is influenced by many aspects of equipment configuration and the pacing strategy employed. Accordingly, manipulations of seat height [5, 6], seat-tube angle, pedal cadence [7], chainring design [8, 9], crank length [10, 11], and the pedal design [1, 10, 12] have all been investigated. Mechanical power is the product of torque and pedal velocity and has been shown to be a key determinant of cycling performance [13]. Torque is the product of the force applied perpendicular to the crank arm and the crank arm length [14]. Although constant torque production would optimise performance, anatomical and gravitational constraints mean that torque is actually produced in a nearly sinusoidal manner with minimal torque being produced when the crank is positioned vertically [15]. Consequently, any strategy that could potentially optimise the crank cycle warrants further consideration. Increasing the length of the crank arm during the downward stroke of the cycle has been shown to produce the highest torque values [15] and has subsequently lead to the design of non-circular chainrings to theoretically achieve such an effect. Nonetheless, the results of the experimental studies to date that have used such an approach could best be described as equivocal [8, 11]. An alternative method to achieve an increase in the crank arm during the downstroke is to potentially modify the foot pedal. The pedal is the terminal point of force transmission and throughout cycling history it has been subject to substantial research and development with a view to improve its design features [1]. Pedals have evolved from the classic loose pedal-shoe contact to a modern lightweight type with tight-cleat fixings. The EasyPedal has been designed with the express 2

intention of increasing the crank arm length during the critical downstroke period. To achieve this mechanical advantage, the EasyPedal prototypes feature lengthened conventional pedals and added an incline. The pedal design only allows anticlockwise rotation around the crank arm to facilitate pedalling and to allow the additional pedal length to temporarily lengthen the crank arm. Therefore, the aim of the proposed study is to assess the effects of the EasyPedal compared to a conventional pedal on measures of cycling efficiency in a group of recreational cyclists. 2. Methods 2.1 Main study methods Participants Fourteen apparently healthy, recreationally active volunteers 9 male and 5 female (Mean ± SD: age 38.2 ± 10.4yrs; height 174.8 ± 6.81cm; body mass 76.2 ± 9.3 kg; max heart rate 182 ± 10.4 beats/min) completed this study. The experimental procedure and nature of risks were explained to all participants. A pre-test questionnaire and informed consent was obtained and reviewed prior to testing. All procedures were approved by the Research and Ethics Committee of the University of Ulster. Experimental Design The study consisted of a single testing protocol at a laboratory on two separate days (3-10 days apart) to examine the EasyPedal (EP) prototype pedal or conventional pedal. The order of pedal was randomized and counter-balanced across the two days. All participants were familiarised with all testing procedures prior to experimental trial. All trials were performed at the same time of day to negate diurnal variation. Participants were required to follow their usual diet, and record all foods consumed 24 hours prior to their first experimental trial. The same diet then was consumed before the second trial. To facilitate compliance, diet sheets were given to each participant, which were brought to the first trial, photocopied, and returned to the participant to ensure replication. Participants were required to refrain from strenuous activity for at least 24 hours prior to each testing day. The testing schedule is illustrated in Figure 1. 3

Figure 1: Testing schedule for participants. Eight participants will use the prototype pedal on test day 1, followed by the conventional pedal on test day 2. The other eight participants will use the conventional pedal on day 1 followed by the prototype pedal on day 2. Data Collection The testing session consisted of a 10 minute warm-up at 90 watts, using either the prototype or conventional pedal. Midway through the warm-up, an oxygen mask was securely fitted to participant. Oxygen consumption was recorded after 7 minutes into the warm-up and was continually monitored using a Cosmed Quark CPET system (Cosmed, Italy). This system was calibrated for volume on each test day and for gas content during each test session. Participants completed an incremental protocol beginning at 120 watts and increased by 30 watts after each 4-minute phase (using the same pedal set-up as in the warm-up). Once the 210 watt phase was completed or when participants reached 90% of their estimated heart rate maximum (HRM), the test was terminated. All testing was completed on a Felt bicycle attached to an electrically braked cycle ergometer (T1980 Bushido Trainer, Tacx, Holland). A brake calibration was completed for each testing session. Participants self-selected their seat height until they were comfortable. A manual measurement was recorded to ensure an identical seat height for the second trial. Heart rate (HR) was recorded continuously during each trial by means of ECG calibration telemetry using the RS 400 (Polar Electro OY, Kempele, Finland). Preceding the first visit to the laboratory, participant s body mass and height were measured to the nearest 0.1kg and 0.1cm, respectively, (Seca Delta-Model 707, Cardiokinetics, UK). Laboratory temperature was controlled at 17 degrees for all trials. In addition, qualitative data was captured of the medial sagittal plane of the lower limb using a Panasonic VDR-D51 video camera at 50 Hz. Video data was recorded 4

after 8 minutes of the warm-up, and midway through the 150 and 210 watt phases for a duration of 30 seconds. Data Analysis Data was collected during the last 2 minutes of each 4 minute phase including the warm-up. Wireless data was received from the ergometer via an infrared dongle (Tacx, T1991) connected to a PC using Tacx trainer software (3.4.0). Statistical Analysis Oxygen consumption, heart rate and power output were assessed using a repeated measures ANOVA with two within subject factors (pedal type and intensity) in SPSS Statistics 17.0. An alpha level of p<0.05 was used throughout to indicate statistical significance. 2.2 Case study 1 methods One healthy recreationally active male (age 31 years, mass 88 kg, height 1.95 m) participated in this study. The experimental procedure and nature of risks were explained to the participant. A pre-test questionnaire and informed consent was obtained and reviewed prior to testing. The case study was carried out over two test days (8 days apart). On the first test day, the participant carried out an 18 minute cycling test using the EP pedals followed by a 2-hr rest period and then repeated the 18-min cycling test using conventional pedals. On the second test day the procedure was repeated, however the order of pedals used was reversed (now Conventional pedals - 2-hr rest - EP pedals). The 18-min cycling test consisted of 10 minutes at 90 watts, followed by 4 minutes at 120 watts and 4 minutes at 150 watts. This was carried out using the same ergometer set-up as described in the main study. However, in the case study the participant sat in a modified semi-recumbant position behind the typical saddle position (see Figure 2). 5

Figure 2: Semi-recumbant set-up during EasyPedal testing in case study 1 The data analysis was identical to the main study, with heart rate and video footage recorded, however the video footage was recorded using a Casio Ex F1 at 300 Hz. No inferential statistical analyses were conducted on the case study 1 results. 2.3 Case study 2 methods One healthy recreationally active male (age 31 years, mass 88 kg, height 1.95 m) participated in this study. The experimental procedure and nature of risks were explained to the participant. A pre-test questionnaire and informed consent was obtained and reviewed prior to testing. The case study was carried out over two test days (5 days apart). On the first test day, the participant carried out a 16 minute cycling test using conventional pedals followed by a 2-hr rest period and then repeated the 16-min cycling test using the EP pedals (new prototypes different than those used in both the main study and case study 1). On the second test day the procedure was repeated, however the order of pedals used was reversed (now EP pedals - 2-hr rest - Conventional pedals). The 16-min cycling test consisted of 7 minutes at 90 watts, followed by three 3-min stages at 150 watts, 180 watts and 210 watts. This was carried out using the same semirecumbant set-up as described in case study 1. Again, the data analysis was identical to the main study, with heart rate and video footage recorded, however the video footage was recorded using a Casio Ex F1 at 6

300 Hz. No inferential statistical analyses were conducted on the case study 2 results. 3. Results 3.1 Main study results No statistically significant differences were detected in oxygen consumption (p=0.521), heart rate (p=0.537) or power output (p=0.222) between the two pedal types (Table 1). Changes in intensity did have a significant effect on oxygen consumption, heart rate and power output (all p<0.01) as expected, with increasing intensity causing increases in all three variables. Table 1: Mean power output, heart rate and oxygen consumption for all cycling intensities Phase Power (Watts) Heart Rate (bpm) Oxygen Consumption (ml/kg/min) Time (min) EP Conventional EP Conventional EP Conventional 8-10mins (90 watts) 99.89 98.53 112.53 107.28 19.79 20.53 12-14mins (120 watts) 120.98 120.40 125.36 121.92 23.49 23.46 16-18mins (150 watts) 148.02 149.96 139.76 135.64 27.23 27.60 20-22mins (180 watts) 175.20 175.19 146.18 143.47 32.08 32.24 24-26mins (210 watts) 201.52 202.18 154.54 152.75 35.31 35.75 Mean 149.12 149.25 135.67 132.21 27.58 27.92 3.2 Case study 1 results Due to the effects of fatigue (causing increases in heart rates during the second half of each test day), the case study results are analysed by comparing pedals types against each other based on the time during the test day that they were used. Therefore, Table 2 illustrates the comparison of pedal types when used at the beginning of the test day and Table 3 compares the pedals when used in the second half of each test day. The results indicate no clear benefit (reduced exertion) of the EasyPedal prototypes in this semi-recumbant set-up. In fact, the conventional pedals tend to show slightly lower heart rates (1-3 bpm) at the same absolute intensity. 7

Table 2: Pedal type results when used during first half of test day (Case study 1). Negative values for differences indicate that the EP value is higher Power (Watts) Cadence (rpm) Heart Rate (bpm) Average Conventional Pedal 8-10mins (90 watts) 91 75 93 12-14mins (120watts) 120 75 104 16-18 mins (150 watts) 150 74 116 Easy Pedal (EP) 8-10mins (90 watts) 93 74 96 12-14mins (120watts) 120 75 104 16-18 mins (150 watts) 150 74 117 Difference (Conventional-EP) 6-7 mins (90 watts) -1 0-3 9-10 mins (150watts 0 1 0 12-13 mins (180 watts) 0 0-1 Table 3: Pedal type results when used during second half of test day (Case study 1). Negative values for differences indicate that the EP value is higher Power (Watts) Cadence (rpm) Heart Rate (bpm) Average Conventional Pedal 8-10mins (90 watts) 90 69 99 12-14mins (120watts) 120 68 110 16-18 mins (150 watts) 150 70 121 Easy Pedal (EP) 8-10mins (90 watts) 90 72 101 12-14mins (120watts) 120 72 109 16-18 mins (150 watts) 150 73 123 Difference (Conventional-EP) 6-7 mins (90 watts) 0-4 -2 9-10 mins (150watts 0-4 1 12-13 mins (180 watts) 0-2 -2 3.3 Case study 2 results Based on a similar analysis approach to Case Study 1, the results indicate no clear benefit of the EasyPedal prototypes in this semi-recumbant set-up (Tables 4 and 5). Conversely the conventional pedals tend to show lower heart rates (0-8 bpm) at the same absolute intensity. 8

Table 4: Pedal type results when used during first half of test day (Case study 2). Negative values for differences indicate that the EP value is higher Power (Watts) Cadence (rpm) Heart Rate (bpm) Average Conventional Pedal 6-7 mins (90 watts) 94 74 89 9-10 mins (150watts 150 71 111 12-13 mins (180 watts) 180 70 124 15-16mins (210 watts) 209 69 138 Easy Pedal (EP) 6-7 mins (90 watts) 91 74 89 9-10 mins (150watts 150 72 115 12-13 mins (180 watts) 180 72 129 15-16mins (210 watts) 210 69 145 Difference (Conventional-EP) 6-7 mins (90 watts) 2 0 0 9-10 mins (150watts 1-1 -4 12-13 mins (180 watts) 0-2 -5 15-16mins (210 watts) 0 0-7 Table 5: Pedal type results when used during second half of test day (Case study 2). Negative values for differences indicate that the EP value is higher Power (Watts) Cadence (rpm) Heart Rate (bpm) Average Conventional Pedal 6-7 mins (90 watts) 91 72 98 9-10 mins (150watts 150 72 119 12-13 mins (180 watts) 180 72 131 15-16mins (210 watts) 210 70 148 Easy Pedal (EP) 6-7 mins (90 watts) 93 74 103 9-10 mins (150watts 150 74 127 12-13 mins (180 watts) 180 70 139 15-16mins (210 watts) 210 68 153 Difference (Conventional-EP) 6-7 mins (90 watts) -2-2 -5 9-10 mins (150watts 0-2 -8 12-13 mins (180 watts) 0 2-8 15-16mins (210 watts) 0 2-5 4. Conclusions The aim of both studies was to assess the effects of the EasyPedal prototypes compared to conventional pedals on cycling efficiency. The main study and case study results do not indicate reduced energy expenditure when using the EasyPedal 9

prototypes versus conventional pedals in either a typical cycling set-up or semirecumbant position. This is based on similar levels of oxygen consumption and heart rate when using both pedal types at the same absolute cycling intensity (measured in watts. However, this does not rule out a potential benefit of the EasyPedal prototype when used at slower cycling cadences (testing in this study carried out at cadences of approximately 70 rpm) or with a novel/alternative cycling pattern. The testing detailed in this report illustrates the acute responses to using these pedal prototypes (i.e. after < 30 minutes of use). It is possible that individuals could learn to perform an altered pedalling style which could make greater use of the potential mechanical advantages of the EasyPedal prototypes. Such an altered style would take time to develop and would change the neuromuscular requirements of the task. It is still unknown how much time would be required to develop such a pattern and what possible advantages it would provide in terms of cycling efficiency 5. References 1. Koninckx, E., M. Van Leemputte, and P. Hespel, Effect of a novel pedal design on maximal power output and mechanical efficiency in well-trained cyclists. Journal of Sports Sciences, 2008. 26(10): p. 1015-1023. 2. Faria, E.W., D.L. Parker, and I.E. Faria, The science of cycling - Physiology and training - Part 1. Sports Medicine, 2005. 35(4): p. 285-312. 3. Coyle, E.F., et al., Physiological and biomechanical factors associated with elite endurance cycling performance Medicine and Science in Sports and Exercise, 1991. 23(1): p. 93-107. 4. Coyle, E.F., et al., Cycling efficiency is related to the percentage of type-i muscle fibers. Medicine and Science in Sports and Exercise, 1992. 24(7): p. 782-788. 5. Nordeensnyder, K.S., Effect of bicycle seat height variation upon oxygenconsumption and lower-limb kinematics. Medicine and Science in Sports and Exercise, 1977. 9(2): p. 113-117. 6. Shennum, P.L. and H.A. Devries, Effect of saddle height on oxygenconsumption during bicycle ergometer work. Medicine and Science in Sports and Exercise, 1976. 8(2): p. 119-121. 7. Hagberg, J.M., et al., Effect of pedaling rate on submaximal exercise responses of competitive cyclists. Journal of Applied Physiology, 1981. 51(2): p. 447-451. 8. Rodriguez-Marroyo, J.A., et al., The rotor pedaling system improves anaerobic but not aerobic cycling performance in professional cyclists. European Journal of Applied Physiology, 2009. 106(1): p. 87-94. 10

9. Belen, L., et al., Cycling performance and mechanical variables using a new prototype chainring. European Journal of Applied Physiology, 2007. 101(6): p. 721-726. 10. Zamparo, P., A.E. Minetti, and P.E. di Prampero, Mechanical efficiency of cycling with a new developed pedal-crank. Journal of Biomechanics, 2002. 35(10): p. 1387-1398. 11. Jobson, S.A., et al., Effect of the Rotor crank system on cycling performance. Journal of Sports Science and Medicine, 2009. 8(3): p. 463-467. 12. Van Sickle, J.R. and M.L. Hull, Is economy of competitive cyclists affected by the anterior-posterior foot position on the pedal? Journal of Biomechanics, 2007. 40(6): p. 1262-1267. 13. Coyle, E.F., Integration of the physiological factors determining endurance performance ability. Exercise and Sport Sciences Reviews, 1995. 23: p. 25-64. 14. Bertucci, W., et al., Effects on the crank torque profile when changing pedalling cadence in level ground and uphill road cycling. Journal of Biomechanics, 2005. 38(5): p. 1003-1010. 15. Faria, I.E., Energy expenditure, aerodynamics and medical problems in cycling - an update. Sports Medicine, 1992. 14(1): p. 43-63. 11