TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

Similar documents
Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Service Call: Vacuum Prevention System Testing on Category A and B Aerial Devices. Tools Required: 1. Atmospheric Vent Test Set (P/N )

Service Call: Procedure for Bleeding the Hydraulic Leveling System. Tools Required: S-Wrench 1/2, 9/16, 5/8, 11/16, & 3/4 Drain Pan

Universal Valve Company Inc

Exercise 3-2. Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Two-wire control

Universal Valve Company Inc

T-02b2: Set Up/Adjust Drive (DC Full Range GE-Valutr

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Operator's Manual Supplement

Approved Models. Important. Contents

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Time-Delay Electropneumatic Applications

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Maintenance of the Electronic ( EPC ) Pressure Controllers on GCs

Operator: Save these instructions for future use!

Control of Energy - Isolation Process

Instructions for High Altitude Conversion

Operator: Save these instructions for future use!

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

User manual CF8-D/W-IN

GV Standard X-Vent. Setup, Commissioning & Installation Guide

MP15 Jockey Pump Controller

WATER CONTROL SYSTEM QUICK START

D I G I T A L C L A M

Touch Screen Guide. OG-1500 and OG Part # T011

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

A U T O O P E N S E R I E S C A P P R E S S O P E R A T O R S M A N U A L

Safety Indicators: Signal Words. Indicates an imminently hazardous situation which, if not avoided, is likely to result in death or serious injury.

OC Panel High Limit Aquastat Kit, Manual Reset p/n

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

SPECIFICATIONS ATTENTION

APPLICATION NOTE E SQUEEZE DELAY AND RETRACTION OPERATION

Conversion instructions from natural gas to propane

Apex Evaporator Manual

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

The MAXX Press DIGITAL CAP OPERATOR S MANUAL

Apollo Safety Features

Propane Conversion Kit Instructions

Operator: Save these instructions for future use!

A I R S W I N G E R O P E R A T O R S M A N U A L

Inside Front cover This page will remain blank.

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

BUBBLER CONTROL SYSTEM

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

EDUCATION DEPARTMENT ACCU-TEST

R E D I C O N T R O L S

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

Gas Network Craftsperson

VERTICAL AIR COMPRESSORS

700 SERIES BMS II BUBBLER MONITORING SYSTEM

OPERATION MANUAL BFX-2

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Service Installation: 48 V Power Supply September 27, 2018 SI Written by BTA

Miniature controls. Contactors. Overload relays. Starters. Control relays

RATED CAPACITY LIMITER SYSTEM DS 350 OPERATOR S HANDBOOK. DS350/1225/1229 Consoles HC 248H OPERATING CODES. Link-Belt. Construction Equipment

SAINT MARY S COLLEGE OF CALIFORNIA STANDARD HAZARDOUS ENERGY CONTROL PROGRAM INCLUDING LOCKOUT/TAGOUT. Prepared by

Flamco Flamco-Fill STA Flamco-Fill STM

Risk and Hazard Management

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

GAS FUEL VALVE FORM AGV5 OM 8-03

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

BUBBLER CONTROL SYSTEM

LCR-6-WT-EPP CYLINDER ROLLER EXPLOSION PROOF SERIES INSTRUCTION MANUAL MANUAL NUMBER Rev A Issued November 2011

OXYGEN MINERALE ABSOLUTE RANGE OWNER S MANUAL OXY MINERALE 600/1000 SERIES

Napa Technology Trouble Shooting. For Premier & Premier PLUS Models

accidents which arise due to non-observance of these instructions and the safety information herein.

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

SPI Supplies Plasma Prep III Process Controller Operation Manual

Manual Leveling Control Installation/Operation

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

USER MANUAL OPERATION AND THE USE OF A CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Operator: Save these instructions for future use!

ENVIRONMENTAL INSTRUMENTS, LLC

OMNISPORT 2000 SWIMMING QUICK REFERENCE

Electrical operating instructions

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

O P E R A T O R S M A N U A O P E R A T O R S M A N U A L L

TROUBLESHOOTING FOR PRO COOLING UNIT

OPERATION MANUAL. For the PARU01. Underwater Plasma Cutting. Supervisors Remote Panel

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Operator: Save these instructions for future use!

Manual Weighingblock VB2 series and Uniscale

Pressure Dump Valve Service Kit for Series 3000 Units

955108_2. AirForce Operator s Guide

Electrical operating instructions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Actuating elements for ComEx

OWNER S MANUAL NMB SERIES

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

5 Channel Calibrator

FAULT CODE TROUBLESHOOTING INDEX

Version-E E100930

VERTICAL AIR COMPRESSORS

Transcription:

Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench Model: TZ34/20 & TZ50/30

Tech Tips Safety Rules Danger Failure to obey the instructions and safety rules in the appropriate Operator's Manual and Service Manual for your machine will result in death or serious injury. Many of the hazards identified in the operator s manual are also safety hazards when maintenance and repair procedures are performed. Do Not Perform Maintenance Unless: You are trained and qualified to perform maintenance on this machine. You read, understand and obey: o manufacturer s instructions and safety rules o employer s safety rules and worksite regulations o applicable governmental regulations You have the appropriate tools, lifting equipment and a suitable workshop. The information contained in this tech tip is a supplement to the service manual. Consult the appropriate service manual of your machine for safety rules and hazards.

Step 1 Perform all operations on firm level ground. When the Auto level module is operating correctly: Once the outriggers pads are in contact with the ground, the green LED lights on the outrigger push-button will light. The TZ will then lift up at the back end until the tires are slightly off the ground, at this point the module will beep. The front of the machine will then lift up, and after a few adjustments, the machine will announce itself level with a long beep. If instead, after attempting to auto level, you find that the outriggers lift the machine to the full extension of the hydraulic cylinders, go to step 2. Step 2 If there is a beep after the outriggers reach full extension, then it is likely the timer module is out of adjustment. However, If there is no beep from the Auto level module, then go to step 3. To re-adjust the timer module, located inside the control box: Begin by turning the blue knob on the timer module, counterclockwise to the.1 second interval, then try auto leveling again. If the auto level now performs correctly, then this was the problem and all that remains, is to adjust the timing interval such that the machine levels out with the tires 2 to 3 inches off the ground. You can now return the machine to service.

Step 3 The Auto level module failing to beep, can indicate failure in one or more of the following components. 1) The Timer module. 2) The timer relay 3) The Auto level module. We will only need to test the first two components, if both of these test good, then the Auto level module is at fault. Keep in mind there could be more than one faulty component, so both the timer module and the relay have to be tested. Manually level the machine and leave the power selector switch set to ground control, for the following tests. Step 4 Testing the Timer module: Connect the ground probe of your multimeter to the black ground wire off the hour meter, this will provide a good ground for the meter. Now while pressing the down function pushbutton (yellow circled), on the panel, you should get the following on the timer module terminals (see photo on right): 1. You should have approximately 24VDC on the Black/Red wire, labeled 'PLUS' in the photo. 2. You should have continuity between the white/black and the black wire, labeled LOAD and MINUS in the photo. If these are your readings, the timer module is working correctly, proceed to testing the timer relay in step 5..

Step 5 The auto level relay is the second one down on the right. Inside the ground control box. Test the Auto level relay: Using the Multi Meter verify there is voltage at terminals 30, 86 and 87 ( 3 red wires) on the relay, while holding down the auto level pushbutton. The relay is working correctly, in which case the failed component is the Auto level module. If however, there is no voltage on 87 and it's found on 87A instead, this would indicate the relay is not switching. Double check this by confirming that the white/black wire on terminal 85 is grounded. Replace the relay if it fails to switch. After replacing any faulty components, test and return the machine to service. Step 6