United Kingdom of Great Britain and Northern Ireland

Similar documents
United Kingdom of Great Britain and Northern Ireland

EC type-examination certificate UK/0126/0065 Revision 1

EC type-examination certificate UK/0126/0126

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Certificate of Approval. No 5/6B/211

Vehicle- or rack-mounted liquefied gas meters, pump supplied

Vehicle-mounted meters, pump supplied

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

EC type-examination certificate UK/0126/0014 Revision 6

P U B L I C N O T I C E

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Metering Code Gas TSO, measurement by connected party Effective from to the present

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

MECHANICAL BULKMETERS BM Series

pren CEN standard-draft pr EN 12261

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

TF- & DM-Series. Turbineflowmeter

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

14. Exploded View. Page 68

GUIDELINES. Systems. Pressure. Guidelines Acceptance of equipment, establishment of safe operating limits and fitness for service

DEUTSCH. Flüssigkeits- Mengenmesser FMO. Seite Flow Meter FMO. Page Compteur volumétrique. Page 43-63

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Air Eliminators and Combination Air Eliminators Strainers

M-06 Nitrogen Generator (Nitrogen Making Machine)

Torque Tube TB300 Digital Transmitters

Summary of the MRA LPG Codes of Practice

G REQUIREMENTS FOR THE INSTALLATION OF GAS BOOSTERS, MICROTURBINES AND ASSOCIATED SYSTEM PROTECTIVE DEVICES

Additive Injectors. AccuPlus. Installation and Operations. The Most Trusted Name In Measurement

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

Organisation Internationale de Métrologie Légale

UNDERSTANDING, ACCELERATED

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

IMPLEMENTATION OF EIGA CARBON DIOXIDE STANDARDS

Circulating Lubrication Systems (Oil)

Residential Meters. Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

SIKA Ba_ODWT15_en 05/2018. Operating manual for oil deadweight tester 0.015% accuracy ODWT15

PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)

Orifice Plate Flow Meter

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Radar, Ultrasonic and RF Level Transmitters

The latest automotive systems require innovative leak test methods and fixturing.

SIHI LPH-X - Liquid Ring Compressors

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format

Turbine Flowmeters for Gas Applications

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

Road and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July

Turbine Flowmeters for Gas Applications

MANUAL. Additive Injector AccuPlus. Installation / Operation Manual. MN05002E Issue/Rev. 0.2 (9/17)

The benefits of system solutions for valve users

MECHANICAL EQUIPMENTS: COMPRESSORS, PUMPS, SEALS, SPEED DRIVES, CONTROL VALVES & ACTUATORS & SAFETY RELIEF VALVES

THERMAL MASS FLOW MEASUREMENT FOR GASES

Spirax Compact FREME Flash Recovery Energy Management Equipment

6-way characterised control valves DN15 and DN 20

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Restriction Orifice. Single or Multi Stage Orifice to. Reduce Pressure or. Limit the Flow Rate

Gas Lift Valve Testing

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise

Flow divider designs MTL

Pressure calibration equipment

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Chlorinator MODEL MK-I

FAQs about Directive 017

Rotor Gas Meter. Creators in flow

Fluid Machinery Introduction to the laboratory measurements

Pressure reducing valve, pilot operated

TH-1800-T TRX-700-CNG Converter

11. Spare Parts. applications since applications since

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

Coriolis Mass Flow Meter

Truck-mounted Mass Flow Metering for LPG Delivery

Electronic Turbine Meter TERZ 94

Specifications of Cryogenic vacuum jacketed valves

É DANAK PROD Feg.No.7025

SonoSelect 10 and SonoSafe 10 energy meters

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

DMX 3 - DMX 3 MF INSTALLATION OPERATION MAINTENANCE. Your distributor : TECHNICAL INSTRUCTIONS (e) Revision

Size 6 up to 31.5MPa 1) up to 25 L/min

AMT-Ex Dewpoint Transmitter

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

The number of revolutions is proportional to the passed volume. The rotation is transferred to a mechanical index, which indicates this volume.

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

WATER METERS.

KRAL Volumeter OME Series. Operating Instructions

RMG Meßtechnik GmbH. Publication No E

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

KTM 50 (DN ) Installation, maintenance and operating instructions

Bubble Tube Installations

Transcription:

(UK/0126/0074) MI-005 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0074 issued by the Secretary of State for Business, Innovation & Skills Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 (SI 2006/1270) which implement, in the United Kingdom, Council Directive 2004/22/EC (MID), this certificate of EC type-examination has been issued to: Toptech Europe NV Nateus Business Park Nieuwe weg 1 - Haven 1053 2070 Zwijndrecht (Antwerp) Belgium in respect of an interruptible measuring system for liquids other than water and having the characteristics described below. Designation : 2-MultiLoad II/Prime4/EGS Q min -Q max : see paragraph 3.1 Minimum measured quantity : 200L Accuracy class : 0.5 Mechanical environment : M2 Electromagnetic environment : E2 Climatic environment : -25 C to +55 C open, condensing Temperature range of liquid : -10 C to +50 C Intended for measurement of : liquid petroleum products, bio-fuels and ethanol The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. Issue Date: 26 th February 2010 Valid Until: 25 th February 2020 Reference No: T1154/0001 Signatory: for P R Dixon Chief Executive National Weights & Measures Laboratory Department for Business, Innovation & Skills Stanton Avenue Teddington Middlesex, TW11 0JZ United Kingdom

Descriptive Annex 1 INTRODUCTION The instrument is an interruptible meter measuring system for loading or unloading road tankers and comprises the MultiLoad II electronic calculator/indicator (flow computer), Prime4 measurement transducer and a choice of gas elimination devices as specified below. 2 CONFIGURATION OF THE MEASURING SYSTEM 2.1 Essential parts 2.1.1 Measurement device The measurement device is manufactured by FMC, typed as Prime4. See paragraph 4.1 for further details. 2.1.2 Electronic calculating/indicating device (flowcomputer) The flow computer is the MultiLoad II, manufactured by Toptech Europe NV. See Evaluation Certificate TC7311 for details. 2.1.3 Gas elimination device The gas separators/indicators are listed in section 4.2. 2.2 Conditional parts 2.2.1 Temperature sensor If a temperature sensor is used, it must be a class A or B PT100 sensor to measure the liquid temperature. The temperature sensor, if fitted, must be installed within 1 metre upstream or downstream of the measuring transducer. The measured liquid temperature can be used by the flow computer to calculate the delivered volume at standard temperature (15 C). 2.3 Non-essential parts - Pump(s), pipe work and connection - Isolating valves - Vent-off valves 2

3 CHARACTERISTICS OF THE MEASURING SYSTEM 3.1 Essential characteristics The essential characteristics of the system are stated on page 1 of this certificate. Q min - Q max See table in section 4.1.3 (1) Maximum working pressure: (P max ) 10 bar Minimum delivery (MMQ): 200 L Type of liquid Liquids other than water of low viscosity except liquefied gases, including biofuels and ethanol. (1) the measurement transducer listed in section 2.1.1 may be used in conjunction with a gas separator device listed section 4.2 providing the maximum rate of flow is not greater than the maximum rate of flow of any component of the system. 3.2 Conditional characteristics 3.2.1 Hydraulic circuit A basic outline of the hydraulic circuit and the essential components are shown in Figure 1, before a delivery is started the system shall be free of air. 3.3 Non-essential characteristics 3.3.1 The measuring instrument is utilised as top loading or bottom loading. 3.3.2 The shape of the name plate. 3.3.3 An optional additive injection point may be present. It is located upstream of the measurement sensor. 3.3.4 Some parts of the system may be used as a common part for multiple measuring instruments. For example the pump can be used to feed multiple instruments. 3

4 MAIN COMPONENTS/PARTS OF THE MEASURING INSTRUMENT 4.1 Measurement device The measurement transducers have the following essential parts: 4.1.1 FMC, Model: Prime4 (including pulse encoder) Measuring chamber: This is a rotary positive displacement type. The measuring chamber consists of a cylindrical housing with an inner rotor having two evenly spaced blades which rotate as liquid flows through the meter (the Rotor revolves on Tungsten carbide bearings); the motion of the blades is controlled with a special cam. Measuring chambers of volume are formed between the two blades, the rotor, the housing and the top cover. Pulse Encoder: The exciter gear, integral part of the rotor, converts rotation of the rotor into electrical pulses together with a pulse pickup located in a well on the side of the meter cover. 4.1.2 The essential characteristics of the measurement sensor are: Model designation Flow rate range Viscosity Q min - Q max (L/min) mpa.s Smith Prime 4 190-3400 0.3-17 3.5-120 8-350 100-1000 500-10000 Non essential parts of the measurement transducer: - Filter. An optional filter can be mounted at the inlet. 4.2 Gas separator device This can be of the following make and has the following essential parts. 4.2.1 Special gas elimination device - S.A.M.P.I. Spa, EGS_X As described in Evaluation Certificate TC 7329. 4.2.1.1 The device has following essential characteristics: Model Designation Bore size Inlet/Outlet Flange (Std. Available) Q Max (L/Min) EGS_1 3300 2", 3", 4" EGS_2 1700 2", 3", 4" 4

4.2.1.2 Optional and non essential parts of gas separator devices: - Strainer before the inlet of the gas separator device - The separated air/gas is released into the air or into a vapour recovery line 5 APPROVAL CONDITIONS 5.1 The certificate is issued subject to the following conditions on inscriptions - Manufacturers mark or name - Accuracy class - Maximum operating pressure - Liquid type(s) - Operating temperature range - Minimum Measured Quantity (1) - Flow rate range - Serial number - Certificate number - CE marking - Supplementary metrology marking - Notified body identification number (1) MMQ stands for Minimum Measured Quantity. The inscription MMQ L in the neighbourhood of the display of the flow computer and/or on the nameplate. 5.2 Location of seals and verification marks 5.2.1 Components that may not be dismantled or adjusted by the user will be secured by either a wire and seal or tamper evident label and securing mark. The securing mark may be either: - a mark of the manufacturer and/or manufacturer s representative, or - an official mark of a verification officer or Notified body 5.2.2 The following items shall be secured: - nameplate to the measuring instrument (incl CE marking). Removal shall be impossible without damaging it or without breaking a seal. - the measurement sensor against removal - electronic pulser against removal - measurement chambers against opening - see TC7329 for sealing of the special gas extractor - the gas indicators (LC sound) of the special gas extractor against removal and opening - the gas extractor against removal 5

- the mechanical connections between the meter sensor and the pulser (if applicable) - the flow computer as described in Evaluation Certificate TC7311 - the temperature sensor used as part of the volume conversion functionality against removal 6 RECOMMENDED TESTS The meter measuring system should be tested at a minimum of two substantially different rates of flow between the maximum and minimum rates of flow. Due regard should be paid to the viscosity of the liquid used for the verification tests to ensure that the permitted limits of error are not likely to be exceeded when other liquids which the system is intended to measure are metered. 7 ILLUSTRATIONS/DOCUMENTATION Figure 1 Figure 2 Figure 3 Hydraulic diagram MultiLoad II Example of the Name plate 8 CERTIFICATE HISTORY ISSUE NO. DATE DESCRIPTION UK/0126/0074 26 th February 2010 Type examination certificate first issued. 6

Figure 1 Example of hydraulic diagram 7

Figure 2 MultiLoad II 8

Figure 3 Example of the Name plate Crown copyright 2010 NATIONAL WEIGHTS AND MEASURES LABORATORY (Part of the National Measurement Office) This material may be freely reproduced except for sale. 9