COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

Similar documents
Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

AIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

Industrial Compressed Air. Ultrasonic Leak Detection Survey Guide

FILTER TYPE PRESSURE SNUBBER

INSTRUCTION MANUAL ULTRASONIC TRAP TESTER UTT 100

Workhorse-15 Oxygen Generator

ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 1 Compressors)

GM Series Dual-Block Multi-Function Gas Control Valves

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Manual Actuated Boiler Blowdown Valves

SonoMeter 30 Energy Meters

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

Budget Range Operators Handbook

Code AWC20HP Air Compressor

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

TECHNICAL DATA. Dry 132a. October 1, 2008

WaterSource Heat Pump Hose Kit Performance Specification-Summary

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

ASSE International Product (Seal) Listing Program

MODEL 9061 ULTRASONIC LEAK DETECTOR INSTALLATION & MAINTENANCE

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Operating Instructions for

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Technical Information Cleanfit CUA451

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Technical Manual. Liquid Level Transmitter CT801-LB/S

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

Universal Valve Company Inc

BUBBLER CONTROL SYSTEM

User Manual for the Mars Calibration Bench

200 PSI COMPRESSORS - MODEL NUMBERS

Pump On Demand. Skimmer System

BUBBLER CONTROL SYSTEM

Ultrasonic level transmitter and indicator

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

IMPORTANT SAFETY INSTRUCTIONS

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

TECHNICAL DATA. Trimpac 257a. September 16, 2013

THE PERFECT PRESSURE DROP TRAP PRIMER

NGP-250/500 Nitrogen Generator Quick Start Guide

TECHNICAL DATA. Trimpac 256a. October 31, 2013

444C DUAL PERFORMANCE VALUE PACK

Workhorse 8 Oxygen System Model No 5665, 5673, 5679

For Multi-Parameter Meters see mvx

400C & 450C DUAL PERFORMANCE VALUE PACKS

OPERATING INSTRUCTIONS

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Best Practices for Ultrasonic Compressed Air Leak Detection

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

100C Air Compressor Kit

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Universal Valve Company Inc

Digital Flow Switch. Series PFM7

SINGLE VALVE WITH LOW-FLOW BYPASS

Pressure switch and Thermostat CAS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

LVU2800 Series. Ultrasonic Level Transmitter

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

SRL SEries. Oil Free Scroll Air Compressors hp kw

SPECIFICATIONS ATTENTION

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

TECHNICAL DATA. Q = C v P S

Type FEQ Slam-Shut Valve

TECHNICAL DATA. Q = C v P S

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

TEST BENCH FOR SAFETY VALVES

Wet pipe low flow foam/water system

TECHNICAL DATA. Q = C v P S

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Operating Instructions Part No

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

South-Tek Systems - Nitrogen Generation Corrosion Inhibiting System. Designed for: Dry or Preaction Fire Protection Systems (FPS)

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

CSA Sample Draw Aspirator Adapter Operator s Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

Using the UltraRAE. Firmware 2.35

A new concept in the storage of liquefied chemical and petrochemical gases Zero leakage Zero fugitive emissions

Sedan Range. Evaporative Loss System Check Clarified Procedure

Visualize Nitrogen Gas Consumption

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

OWNER S TECHNICAL MANUAL

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

TECHNICAL DATA CAUTION

Plant, components and devices for very high and high pressures (7000 bar and over)

Residential Pressure Booster Systems

Transcription:

INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist

Information provided herewith is believed to be accurate and reliable. However, no responsibility is assumed for its use or for any infringement of patents or rights of others, which may result from its use. In addition, JORC reserves the right to revise information without notice and without incurring any obligation.

AIR LEAKS Air leaks are a concern for anyone operating a compressed air system. The average plant with no formal leak management program will have air leaks that waste up to 30 percent of the total air capacity. Leaks will cause compressors to run at full load for longer periods of time. The compressors will not only use more energy but, may also need additional maintenance due to the increased loads. Leaks can give the false impression that additional compressors are required to meet the demand for compressed air. COMMON LEAK POINTS Quick connections fittings have o-rings to seal the hose connections. A damaged or missing o-ring will cause the connection to leak. FRL s (filter, regulator & lubricator) The welds found on pipe joints and pipe flanges can leak due to vibrations, age or improper welding. Float or mechanical type condensate drains are also a source of air leaks. Pipe thread connections, air tools and many more sources can be the cause of air leakages. AIR LEAK SAVING AND DETECTING AIR-SAVER The air that is stored in the receiver can leak out through the above mentioned sources of air leaks. This is a direct waste of energy. The Air-Saver is installed on the air piping that comes out of a receiver tank. It can be programmed to automatically open just prior to the start of a work shift and close just after the end of the work shift. The Air-Saver is an improvement to any compressed air system with the above mentioned air leak problems and has a fast payback. LOCATOR The Locator is an ultrasonic leak detector and is a necessary part of a leak prevention program. When a gas passes through a restricted orifice under pressure, it is going from a pressurised laminar flow to low pressure turbulent flow. The turbulence generates a broad spectrum of sound. There are ultrasonic components in the sound and since the ultrasound will be the loudest by the leak site, the detection of these signals is usually quite simple. The Locator is easy to use and effective at finding compressed air leaks.

AIR-SAVER G1 AIR-SAVER G1 Compressed air energy saver PRODUCT FEATURES A typical compressed air system will have air loss through pipe work connections, leaking float type drains etc. At the end of the daily working shift the Air-Saver will shut the air tank off from the rest of the system. The content of compressed air within the air tank will be saved rather than lost through pipe work leakages. The Air-Saver is installed on the air outlet of the air tank. The Air-Saver will automatically OPEN just prior to the working shift begins and CLOSES just after the working shift is over. COMMERCIAL BENEFITS Microprocessor controlled (7 day program feature - multiple cycles possible each day - ) Fully automatic - no maintenance External push button controls (disassembly not necessary) Easy to program LCD displaying the program cycle and the current time. Small compact design. Each individual day can be programmed according to specific working day shift requirements TECHNICAL ADVANTAGES Any type of condensate drain can be applied. No de-rating required. Easy serviceable/maintenance.

INSTALLATION PRODUCT SPECIFICATIONS Supply voltage 115V or 240 VAC/DC 50/60Hz Power consumption 7W during cycle rotation Opening / Closing duration 30 sec. / 90 Operating temperature 0 C to +60 C Valve Nickel plated brass with stainless steel ball Connection 1" BSP or NPT Pressure range 0-16 bar (230 psi maximum) Indicators LCD indicating program and current time AIR-SAVER G1 TECHNICAL SPECIFICATIONS PRODUCT FEATURES Built-in quartz controlled timer. Large LCD display. Current time display. Reset function. Remote control option. 1 st/st rotation ball.

AIR-SAVER G2 AIR-SAVER G2 Compressed air energy saver PRODUCT FEATURES A typical compressed air system will have air loss through pipe work connections, leaking float type drains etc. At the end of the daily working shift the Air-Saver will shut the air tank off from the rest of the system. The content of compressed air within the air tank will be saved rather than lost through pipe work leakages. The Air-Saver is installed on the air outlet of the air tank. The Air-Saver will automatically OPEN just prior to the working shift begins and CLOSES just after the working shift is over. COMMERCIAL BENEFITS Microprocessor controlled (7 day program feature - multiple cycles possible each day - ) Fully automatic - no maintenance External push button controls (disassembly not necessary) Easy to program LCD displaying the program cycle and the current time Small compact design Each individual day can be programmed according to specific working day shift requirements TECHNICAL ADVANTAGES Orifice 2" FPM seals Stainless steel ball, valve is nickel plated brass Slow ball valve rotation 90 degrees in 105 seconds (designed to avoid water-hammer when Opening or Closing)

INSTALLATION PRODUCT SPECIFICATIONS Supply Voltage 230VAC or 115VAC 50/60 Hz Power consumption 7W during cycle rotation Opening / Closing duration 2 105 sec. / 90 Maximum Ambient temperature 50 C Maximum medium temperature 100 C Pressure range 0 to 16 bar (230 psi maximum) Valve 2 connections, brass/nickel plated Manual override Yes Environmental protection IP54 Timer display 24 hours AIR-SAVER G2 TECHNICAL SPECIFICATIONS PRODUCT FEATURES Built-in quartz controlled timer. Large LCD display. Current time display. Reset function. Remote control option. 2 st/st rotation ball

LOCATOR LOCATOR Ultrasonic air leak detector PRODUCT FEATURES What produces ultrasound in a leak? When a gas passes through a restricted orifice under pressure, it is going from a pressurised laminar flow to low pressure turbulent flow. The turbulence generates a broad spectrum of sound. There are ultrasonic components in the sound and since the ultrasound will be the loudest by the leak site, the detection of these signals is usually quite simple. COMMERCIAL BENEFITS Ultrasonic leak detection to save money SMT/solid state hybrid heterodyne receiver Supplied in case, complete with headset and rubber focussing probes Production does not need to be disturbed when the LOCATOR is being used. Fully automatic - no maintenance TECHNICAL ADVANTAGES Leaks will be detected from a distance (up to 10 meters) Highly effective in locating leaks and incredibly simple to apply. Very little time is required to locate leaks throughout a factory

INSTALLATION PRODUCT SPECIFICATIONS Construction Hand held ABS pistol type ultrasonic processor Stainless steel sensor enclosures Circuitry SMT/Solid state hybrid heterodyne receiver Frequency Response 20-100 khz (centered at 28-42 khz) Indicator 10 segment leak indication LED bar Sensitivity Selection 8 sensitivity positions Power 9 volt alkaline battery Low battery indicator LED Headset Noise isolating type: double headset wired monophonic Impedance: 16 ohms. Over 23 db noise attenuation. Meets or exceeds ANSI specifications and OSHA standards. Transmitter Warble tone transmission Response time 300 mille seconds Ambient operating temp. 0 50 degrees C. (32 120 degrees F) Relative humidity 10 95 % LOCATOR TECHNICAL SPECIFICATIONS PRODUCT FEATURES Supplied in its own case with all the required accessories. Visual indication Audible leak warning