Level sensing relative and absolute pressure transmitter type 712

Similar documents
Relative pressure transmitter type 520

Electronic relative and differential pressure switch type 616

Relative and differential pressure transmitter type 692

Relative and differential pressure module type 698

Relative pressure switch type 521

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Pressure Measurement Single-range transmitters for general applications

OPTIBAR P 1010 C Technical Datasheet

Expert Hydrostatic Level Transmitters

Pressure Measurement Single-range transmitters for general applications

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

SITRANS P measuring instruments for pressure

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Pressure Measurement Single-range transmitters for general applications

ATM.1ST/Ex - High Precision Transmitter

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

High-performance submersible pressure transmitter For level measurement Model LH-20

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-20

ATM - Analog Pressure Transmitter

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ED 701 Hygenic Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-20

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

ATM/Ex - Analog Pressure Transmitter

Gas density monitor With integrated transmitter Model GDM-100-TI

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Transmitters 36 F-27839

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

ATM.ECO - Analog Pressure Transmitter

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. Dimensions

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-10

9700 Transmitter Submersible hydrostatic level transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Technical Data. Dimensions

Hidrostatic Level DATASHEET

Technical Data. Dimensions

Level transmitter LT 100

SENSORS Pressure CALDARO

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

MDM490 Piezoresistive Differential Pressure Transmitter

Technical Data. Dimensions

JUMO dtrans p30 Pressure Transmitter

86BSD Backside Digital Output

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Bourdon tube pressure gauge for diaphragm seals

Technical Data. General specifications. Rated operating distance s n 2 mm

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

AMS 2710 PCB pressure sensor module with V output

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

P499 Heavy Duty Pressure Transducer

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals

SPD310/SPD360 Air Differential

Torque Tube TB300 Digital Transmitters

Micro Motion 7812 Fiscal Gas Density Meter

Programmable Submersible Level Transmitters

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Technical Data. Dimensions

Precision pressure sensor Basic version Model CPT6020

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

BS12N Piezoresistive OEM Pressure Sensor

C-Flow Coriolis Mass Flow Meters

P900. P900, Datenblatt Seite 1 DESCRIPTION

Programmable pressure and temperature transmitters PTM/RS485

BS12 Piezoresistive OEM Pressure Sensor

TGD-L (LP) Tank Gauging Device TGD L (Level) TGD LP (Level Pressure) Main features:

MPM426W/436W Submersible Level Transmitter

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Inductive slot sensor

Transcription:

Level sensing relative and absolute pressure transmitter type 712 Pressure range 0... 0.3-3 bar The level sensing pressure transmitter Type 712 is manufactured using an relative or absolute pressure measuring cell with an adjusted and amplified sensor signal and is available with various cable lengths from 2 to 30 meters. The Type 712 offers Ex protection as well as versions with integrated temperature measurement. In addition to voltage and current outputs the Type 712 is available with ratiometric outputs. suitable for drinking water intrinsically safe execution with voltageand current output suitable for fitting in 1-inch pipe with integrated temperature measurement Huba Control type 712 - Technical data subject to change - Edition 09/2018 1/6

Technical overview Pressure range Relative Absolute Operating conditions Medium Temperature Overload Materials in contact with medium Case Sensor Cable Protection cover Sealing material Medium and ambient 2) Storage 0.0... 0.3 2.5 bar 0.8... 1.4 3.0 bar Fuel oil, ultra-light 1) SN 181 160-2 Fuel oil, heavy 1) SN 181 160-2 Diesel oil 1) Benzine 1) Drinking water (with EPDM O-ring) -20... +80 ÀC -40... +80 ÀC 3x fs; max. 3 bar at 0.3 bar version Stainless steel 1.4404 / AISI 316L Ceramic Al2O3 PE-HD PPE FPM, EPDM (for drinking water) Electrical overview Output Power supply Load Current consumption 2 wire 4... 20 ma 10... 30 VDC < Power supply - 7 V 0.02 A [Ohm] < 20 ma 3 wire 0... 10 V 12... 30 VDC >10 kohm / < 100 nf < 5 ma ratiom. 10... 90% 5 VDC μ10% > 5 kohm / < 100 nf < 3 ma 4 wire (with temperature) ratiom. 10... 90% 5 VDC μ10% > 5 kohm / < 100 nf < 3 ma Polarity reversal protection Short circuit proof and protected against polarity reversal. Temperature output > 1 MOhm Dynamic response Response time Runtime Time starts at the moment of application of minimal supply voltage < 2 ms < 10 ms Electrical connection Protection standard Cable PE-HD length 2, 5, 10, 15, 20, 30 m IP 68 Test / Admissions Electromagnetic compatibility CE-conform acc. to EN 61326-2-3 UL ANSI/UL 61010-1 acc. to E325110 Drinking water approval ACS UBA guidance (KTW and elastomer) Drinking water verification certificate for plastic parts W270 WRAS Ex-protection IECEx SEV 12.0006 SEV 12 ATEX 0138 Weight Without cable Ex ia IIC T4 Ga II 1 G Ex ia IIC T4 Ga ~ 200 g Packaging Single packaging Accuracy Standard Parameter Unit Max. deviation 3) at 25 ÀC % fs μ 0.8 Resolution 4) % fs 0.1 Thermal characteristic 5), 6) % fs/10k μ 0.2 Long term stability acc. IEC EN 60770-1 max. % fs μ 0.25 Higher accuracy (only with ratiometric execution and pressure range > 1 bar) Parameter Unit Max. deviation at compensated temperature range 3) at -10... +60 ÀC % fs μ 0.5 Resolution % fs 0.1 Long term stability acc. IEC EN 60770-1 max. % fs μ 0.25 1) Ex-protection to attention! 2) non-congealing media 3) incl. zero point, full scale, linearity, hysteresis and repeatability 4) pressure range 0.3 bar < 0.2 % fs 5) at -20... +80 ÀC 6) 0.3 bar-type with output 4... 20 ma = μ0.5% fs/10k 2/6 Huba Control type 712 - Technical data subject to change - Edition 09/2018

Order code selection table 1 2 3 4 5 6 7 8 9 10 712. X X X X X X X X X X Absolute 8 Pressure mode Relative 9 Absolute with higher accuracy C 1,2 Relative with higher accuracy D 1,2 Pmax. 0.0... 0.3 bar relative pressure 4.5 bar 9 1 3 0.0... 1.0 bar relative pressure 4.5 bar 9,D 1 1 0.0... 1.6 bar relative pressure 6.0 bar 9,D 1 2 0.0... 2.5 bar relative pressure 9.0 bar 9,D 1 4 Max measurable level (for water depending Pressure range 1) on the locations weather) 0.8... 1.4 bar absolute pressure 4.5 bar 3.5... 6.7 mws 8 1 1 0.8... 2.0 bar absolute pressure 6.0 bar 9.6... 12.8 mws 8,C 1 2 0.8... 3.0 bar absolute pressure 9.0 bar 20.0... 23.0 mws 8,C 1 4 Full scale signal at these pressures ❶ ❷ ❶ P BARO = 1060 mbar (high pressure on sea level) ❷ P BARO = 740 mbar (low pressure at 2000 meters above sea level) Sealing material FPM Fluoro-elastomer 0 EPDM Ethylene propylene (for drinking water) 1 4... 20 ma 10... 30 VDC 0 Output / power supply ratiom. 10... 90% 5 VDC μ10% 1 ratiom. 10... 90% 5 VDC μ10% (with temperature) 2 0... 10 V 12... 30 VDC 3 0 2 m 0 5 m 1 Electrical connection 2) Cable 10 m 2 15 m 3 20 m 4 30 m 5 Protection cover without protection cover 2 0 with protection cover 2 1 Ex-protection without ex-protection 0 with ex-protection 4 Pressure range variation (optional) Indicate W and state range on order (e.g.: W0... + 2bar/OUT0...10V) W Dimensions in mm / Electrical connections h - Fluid level - Measurement reference height A - Distance from protection cover to the position of measuring diaphragm B - distance from beginning of thread to the position of measuring diaphragm (versions without protection cover) h 4... 20 ma ratiom. 10... 90%, 0... 10 V ratiom. 10... 90% with temperature yellow Device design with explosion protection: 4... 20 ma The grounding connection is conductively connected to the level transmitter housing. The ground conductor of level transmitter must be connected to the equipotential bonding system of the plant. Device design with explosion protection: ratiom. 10... 90% The electronic GND is connected with a 1MΩÃ resistor to the level transmitter housing. The GND conductor of level transmitter must be connected to the equipotential bonding system of the plant. yellow 1) Other pressure range on request 2) Other cable length on request Huba Control type 712 - Technical data subject to change - Edition 09/2018 3/6

Accessories Cable hanger 118026 Connection box 118027 Test adapter 118028 Protection cover (pack of 10) 118067 Humidity protection element (pack of 10) 118068 Additional weight 118093 Calibration certificate 104551 Order number Connection box (1) Mounting hole (2) Vent valve (A) Measuring value process (B) Vent pipe (C) to the transmitter (B) (A) (C) Additional weight ~200 g Protection cover Cable hanger hot-dip galvanized steel PA6 glass fibre reinforced 1) Inside thread Iso 228/1-G ¼ A Cable ± 4.5... 6.5 4/6 Huba Control type 712 - Technical data subject to change - Edition 09/2018

Calculation of level General level with relative pressure sensor: General level with absolute pressure sensor: which and Using a second level sensor as barometric air pressure sensor For level sensor with current output use nominal signal values for I TS... instead of variables U TS... (resp. I Baro... instead of U Baro...) Simplification of formula for level sensor with ratiometric output: Using a second level sensor as barometric air pressure sensor Legend: h level [m] ρ density of media [kg/m 3 ] g acceleration of fall 9.80665 [m/s 2 ] p measured relative pressure [Pa] P TS measured pressure of level sensor [Pa] U TS signal on level sensor output [V or ma] P BARO measured pressure of barometer [Pa] U BARO Signal on barometer output [V or ma] P TS_NP minimal nominal pressure of level sensor [Pa] U TS_NP minimal nominal signal of level sensor [V or ma] P TS_EW maximum nominal pressure of level sensor [Pa] U TS_EW maximum nominal signal of level sensor [V or ma] P BARO_NP minimal nominal pressure of barometer [Pa] U BARO_NP minimal nominal signal of barometer [V or ma] P BARO_EW maximum nominal pressure of barometer [Pa] U BARO_EW maximum nominal signal of barometer [V or ma] Specification temperature output a + b In + c In OUT T OUT T 3 T TEMP Temperature NTC [ÀC] OUT T Voltage NTC [V] T 0-273.15 [ÀC] R 20'000 [Ω] U IN 4.5... 5.5 [V] a = 0.001204001 b = 0.000208775 c = 0.000000294 T TEMP = (OUT T) T TEMP (ÀC) T TEMP (ÀC) @ U IN = 4.5 V T TEMP (ÀC) @ U IN = 5.0 V T TEMP (ÀC) @ U IN = 5.5 V Difference to the measured temperature [ÀC] Max. error of the temperature output Temperature [ÀC] OUT T (V) Huba Control type 712 - Technical data subject to change - Edition 09/2018 5/6

Huba Control AG Headquarters Industriestrasse 17 5436 Würenlos Telefon +41 (0) 56 436 82 00 Telefax +41 (0) 56 436 82 82 info.ch@hubacontrol.com Huba Control AG Niederlassung Deutschland Schlattgrabenstrasse 24 72141 Walddorfhäslach Telefon +49 (0) 7127 23 93 00 Telefax +49 (0) 7127 23 93 20 info.de@hubacontrol.com Huba Control SA Succursale France Rue Lavoisier Technopôle Forbach-Sud 57602 Forbach Cedex Téléphone +33 (0) 387 847 300 Télécopieur +33 (0) 387 847 301 info.fr@hubacontrol.com Huba Control AG Vestiging Nederland Hamseweg 20A 3828 AD Hoogland Telefoon +31 (0) 33 433 03 66 Telefax +31 (0) 33 433 03 77 info.nl@hubacontrol.com Huba Control AG Branch Office United Kingdom Unit 13 Berkshire House County Park Business Centre Shrivenham Road Swindon Wiltshire SN1 2NR Phone +44 (0) 1993 776667 Fax +44 (0) 1993 776671 info.uk@hubacontrol.com www.hubacontrol.com 6/6 Huba Control type 712 - Technical data subject to change - Edition 09/2018