KLS Martin ME MB 1 Endo

Similar documents
Electrosurgery. Ingenuity is always quite simple

Electrosurgery. Ingenuity is always quite simple

HelixAR. Electrosurgical Generator with Argon Beam Coagulation

endo gastroenterology in mind endo 1

10 Best Practices for Electrosurgical Unit Testing

ALAN. Electrosurgery Re-defined. AN ISO : 2003 COMPANY

Beamer CE600 System. Endoscopic Electrosurgical Platform

Electrosurgical and Argon Coagulation Units ENDO ARC and ENDO Plus. Simply safe.

Instruction Manual. ErgoLAP BIPOLAR

EndoWorld UNITS 4-1-E/ CO 2. Insufflation

Introduction. J-PLASMA and Laser have many similarities, but also some important differences.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

DSL# Rev. 12/ All Rights Reserved. PR1011-HS. Product Catalog

Columbus Instruments

OptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light

Contents. Introduction General lnformation Operational Functions... 3 Specifications...3 Description Of Controls...3 Contents...

Operating Manual * * Pressure Transmitter. Table of Content. 1 Safety Guidelines. 1.3 Risks due to Non-Observance of Safety Instructions

ALSATOM MB1 MC, ALSATOM MB1/A MC INSTRUCTION MANUAL

CO2 incubator with additional process controls

SURGITRON USER MANUAL TELEFON Art. Nr

Smoke evacuation system

Solutions for transcutaneous monitoring

Installation, use and maintenance instructions. Gas burner (5)

Instruction Manual Differential Pressure Transmitter

SO THAT LIFE CAN GO ON

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

OPERATING MANUAL ARGON COAGULATION UNIT

Keep the balance in sight

Digital Tourniquets. Product Details. For electricity VAC, 50/60 Hz

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

LEEP PRECISION TM Integrated System, 120 VAC Model LP Operating Manual Rev. A 10/13

Instruction Manual Contact Pressure Vacuum Gauge

LEEP System 1000 TABLE OF CONTENTS. I. Professional Use Guide...2. II. System Features III. Electrical Precautions...14

White Paper: Argon Coagulation Tissue Effects Using Pre-Clinical Data Comparing the Genii gi4000 and ERBE VIO300D/APC2 electrosurgery generators

MANUAL KPS Pressure Control Valve

SYSTEM GUIDE ENDOSCOPY SYSTEM-RELATED INSTRUCTIONS FOR USE

TRANSCUTANEOUS CO2 MONITORING (TCpCO2) PURPOSE

IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N

Amended Technical Specifications BLOOD GAS ANALYZER

LUNA V. User Manual. Warning

medisun UV-therapy FOR THERAPY AT HOME AND IN DOCTOR S PRACTICES

Technical Data Sheet MF010-O-LC

Dräger PSS 4000 Self Contained Breathing Apparatus

Head and Neck Reconstructive and Oncologic Surgery

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

CO2 incubator with additional process controls

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)

Ripple Tank with LED-light source, complete

Instruction Manual Differential Pressure Transmitter

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management

Light beam devices. Product range Light beam devices

Instructions for Use for CAIMAN Instrument (12 mm x 44 cm) Item #: US731SU

PRC CO ² -LASER PRESENTATION

Introduction of HIFU

TJF-Q180V Cleaning and Disinfection Checklist

F-330 Instruction manual. Magic Glove Bio Skin Smoother High Frequency Ultrasound Galvanic

ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug

INTRODUCING CARDIOSAVE Hybrid MORE THAN A PUMP. A REVOLUTION. SPECIFICATIONS

Innovation at its best

Achat 112 mid-high-range speaker. user manual

Mass Flow Controller (MFC) for Gases

Gebrauchsanweisung Mode d' emploi Instrucciones para el uso Istruzioni per l'uso Инструкции по зксплуатации. ri-fox N

Optimum oxygen supply for your patients! ATMOS Oxygen Supply

TJF-Q180V Cleaning and Disinfection Checklist

TECOTHERM NEO. Instructions for Use. MEDICAL EQUIPMENT for HYPOTHERMIA of NEONATES and INFANTS. Addendum 1 to

SCIENCE LAB UTILITY CONTROLS

PHOENIX L300i Best-in-class Helium Leak Detectors

Warning. This product does not belong to medical, please don t use for disease treatment!

Type C-CUT. Quickstart. English Deutsch Français

boso Germany Do you? Premium quality essgeräte für die Selbstmessung I use equipment of BOSCH + SOHN to measure blood pressure.

Series Environmental Chambers

UNITS /2017-E ENDOFLATOR 50. The New High-Performance Insufflator with Integrated Heating Element from KARL STORZ

Dual fuel Gas-Oil/Gas burner

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

AED Trainer NF1200-T. Operator s Manual

Operating instructions Installation instructions To be kept in the vehicle!

Automatic Control Unit. Controlmatic E. Type Series Booklet

Work Theory. HIFU (High-Intensity Focused Ultrasound) which is the new technical for face lifting and tightening.

A Trusted Path to Outstanding Outcomes

Mass Flow Controller (MFC) for Gases

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

HI 2314 HI 2315 HI 23151

EXERCISE 8: BLEEDING TIME

Hydro Microdermabrasion and Oxygen Spray Instruction

ATMOS Wound Therapy. The choice is yours! ATMOS S 041 Wound ATMOS S 042 NPWT. MedizinTechnik

Drying ovens FD series Drying ovens with forced convection Leistungsmerkmale/Ausstattung:

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Instructions for Use Reprocessed LigaSure Maryland Jaw Sealer/Divider. Reprocessed Device for Single Use. Reprocessed by

Tourniquet Systems Pressure Infusion

Please read these instructions carefully before use! Please consider the safety instructions! Please keep for future reference!

User Manual PTW-DensiX. D / Di/Zi

DENAS Reflexo (p.21 40)

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Customer Responsibilities

Owner s Manual. TreasureHound Depth Multiplier with EagleEye Pinpointing

Transcription:

Electrosurgery KLS Martin ME MB 1 Endo SIMPLE. PERFECT

High-frequency in perfection KLS Martin Electrosurgical Unit ME MB 1 Endo Safety by easy use. 3 2 1 1 High patient safety thanks to the Patient Control System 3 With Endo-Mode, you have everything under control The integrated KLS Martin Patient Control System (PCS) ensures that no burns can be caused on the patient s skin. The system automatically adjusts to given tissue impedances; it is also able to recognize single and twin-pad neutral electrodes. So if such a neutral electrode with dual contact surfaces has been connected, the system permanently monitors the proper application of the electrode. Whenever the electrode happens to be in insufficient contact with the patient s skin, the user is alerted to this fact by means of an optical signal. The power is cut off. Endo-Mode. The time-controlled cutting mode of the ME MB 1 that you can switch on at any time. It offers a fractionated and therefore controlled cut for special applications, especially in endoscopy. When dealing with pedicled tumors in endoscopic polypectomy or endoscopic papillotomy, you need a short intensive pulse (or peak) when starting the cut, due to the changing impedances during the thermal dissection phase. At the same time, the coagulation capability must be sufficient to guarantee proper hemostasis. 2 Functional test Whenever the unit is switched on, the KLS Martin ME MB 1 performs a self-test. If a fault is detected, no OK signal is emitted and HF power output is blocked immediately. This ensures that the KLS Martin ME MB 1 can be used only when it is in perfect working order and thus fully reliable. Any accessories connected are also checked for proper functioning during the self-test. pulse cutting current coagulation phase time

3 Types of current provided by the KLS Martin ME MB 1 Endo Monopolar cutting 1 (pure) Cutting current allowing smooth, scab-free cuts 5 Monopolar cutting 2 (blend) Cutting current allowing a smooth cut with little scabformation Endo-Mode Time-controlled cutting mode 6 7 4 8 Monopolar contact coagulation Coagulation current with deep-reaching effects; electrode in direct contact with the tissue. Particularly suitable in TUR Monopolar spray coagulation for surface coagulation (fulguration). This type of current is particularly suitable for hemostatic purposes when performing TUR with small-surface electrodes (e.g. loop-type electrodes) Bipolar coagulation for a broad range of applications 4 Connector for monopolar hand switches 7 Bipolar coagulating with foot switch The unit ME MB 1 incorporates a connector that allows connection of monopolar hand switches equipped with either a large KLS Martin coaxial connector or a US 3-pin connector. KLS Martin s HF range of accessories provides an extensive selection of handles for various applications. The power range of the KLS Martin ME MB 1 is rounded off by the Bipolar coagulation option. KLS Martin s reliable bipolar coagulation function combines utmost precision with maximum safety that is also guaranteed when coagulating large volumes. 5 Progressive power control In the lower range, the power can be adjusted with high precision thanks to the unit s progressive (non-linear) output characteristic. This function is very helpful, for example, for stopping microvascular hemorrhages. In the upper range, the power can be adjusted on a linear basis. Due to its high power reserve, the unit is universally applicable. 8 Multifunction connector for bipolar instruments Bipolar active electrode socket combined for the small coax-plug (KLS Martin standard) or international accessories. 6 Monopolar cutting and coagulation by means of the foot switch In the case of the KLS Martin ME MB 1, these buttons allow cutting and coagulating by using only one foot switch.

MABS KLS Martin Argon Beamer System Using the KLS ME MB 1 in conjunction with the Argon Beamer MB 181 opens up a whole new range of applications in open as well as endoscopic surgery. With this coagulation technique, the HF current is applied to the tissue in a non-contact procedure using ionized argon gas. The advantages of this approach include: fast and effective coagulation of extended hemorrhages tissue-friendly procedure with little blood loss coagulation with little carbonization low coagulation depth fast wound healing

Gebrüder Martin GmbH & Co. KG A company of the KLS Martin Group Ludwigstaler Str. 132 D-78532 Tuttlingen Postfach 60 D-78501 Tuttlingen Tel. +49 7461 706-0 Fax +49 7461 706-193 info@klsmartin.com www.klsmartin.com 11.06. 90-157-02-05. Printed in Germany Copyright by Gebrüder Martin GmbH & Co. KG Alle Rechte vorbehalten Technische Änderungen vorbehalten We reserve the right to make alterations Cambios técnicos reservados Sous réserve de modifications techniques Ci riserviamo il diritto di modifiche tecniche