Type overview. R B2 en-gb subject to changes 1

Similar documents
Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types. Technical data. Safety notes

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Overview of types. Technical data

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Products no longer available

Products no longer available

Type overview. Technical data. Safety notes

6-way characterised control valves DN15 / DN 20 / DN 25

Products no longer available

For latest prices and delivery to your door visit MyTub Ltd

Products no longer available

Dimensioning open-close, control and pressure-independent valves. Table of contents. General notes for project planning

6-way characterised control valves DN15 and DN 20

Two-port valves, male threaded, PN25

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

2-port seat valves PN25 with externally threaded connections

2-port and 3-port seat valves, PN16

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16

3-port seat valves with externally threaded connection, PN 16

2-Port and 3-Port Seat Valves with Female Thread, PN16

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

Pressure Reducing Valve DMV 750 set range: bar

Seated valves VRB 3, VRG 3

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Rotary valves HRB 3, HRB 4

Two-port seat valves

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Radiator valves VDN2.. VEN2.. VUN2..

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

STA. Double regulating valves DN 15-50

STAD-C. Balancing valves DN 15-50

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Pressure independent control valve (PICV) FLOWMATIC

Pressure Relief Valve DHV 718

Radiator valves VDN1.. VEN1..

Pressure Independent Control Series

AVP-F. p setting range (bar) Code No. 003H6200

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

HERZ - Compact Flow Controller with

AVPQ/AVPQ-F, PN 16. Application

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN15 TO DN32)

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

2-port and 3-port valves PN 16

STA. Double regulating valves DN 15-50

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

HERZ - Compact Flow Controller with

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION

STAD. Balancing valves DN 15-50

STAD-C. Balancing valve ENGINEERING ADVANTAGE

differential pressure regulating valve - threaded

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Rotary valves HRB 3, HRB 4

Gas Pressure Regulator HON 300

STAD. Balancing valves DN (MD60, MD61, MD62)

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

VZL valve - 2/3/4-way

USER MANUAL Version: 1/2017

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

HERZ-Motorised flow controler

Pressure Reducing Valve DMV 755

Mounting and Operating Instructions EB 3009 EN. Self-operated Regulators. Type RS Check Valve (backflow protection)

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Installation, commissioning and servicing instructions

DRU/HE THREE-WAY ROTARY VALVE PN10 AND HE25/32 EXTENSION

3-way control valves VK 3

Ballorex Dynamic Description. Versions. Benefits. Balancing

Pressure balanced valves (PN 25)

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

Pressure reducing valves Index

Pressure Reducing Valve for Steam Type 2333 A

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Installation & Operation Manual Proven Quality since 1892

B2KL: 6-way ball valve with male thread, PN 16

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

DS MB, MBF THREE PORT VALVES

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

TA-FUSION-P. NPT threads / ANSI flanges

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Upgradable balancing valves USV

Differential Pressure Control Valve. Passim

safety Shut-Off Valve HON 721

Floor heating. Floor heating manifolds Distributors

Transcription:

Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of thermal heating/ cooling elements For closed cold and warm water systems overview DN [ ] kvs (Sequence I) [ m³/h] kvs (Sequence II) [ m³/h] R3015-P25-P25-B2 15 1/2 0.25 0.25 16 R3015-P25-P4-B2 15 1/2 0.25 0.4 16 R3015-P25-P63-B2 15 1/2 0.25 0.63 16 R3015-P25-1-B2 15 1/2 0.25 1 16 R3015-P25-1P3-B2 15 1/2 0.25 1.3 16 R3015-P4-P25-B2 15 1/2 0.4 0.25 16 R3015-P4-P4-B2 15 1/2 0.4 0.4 16 R3015-P4-P63-B2 15 1/2 0.4 0.63 16 R3015-P4-1-B2 15 1/2 0.4 1 16 R3015-P4-1P3-B2 15 1/2 0.4 1.3 16 R3015-P63-P25-B2 15 1/2 0.63 0.25 16 R3015-P63-P4-B2 15 1/2 0.63 0.4 16 R3015-P63-P63-B2 15 1/2 0.63 0.63 16 R3015-P63-1-B2 15 1/2 0.63 1 16 R3015-P63-1P3-B2 15 1/2 0.63 1.3 16 R3015-1-P25-B2 15 1/2 1 0.25 16 R3015-1-P4-B2 15 1/2 1 0.4 16 R3015-1-P63-B2 15 1/2 1 0.63 16 R3015-1-1-B2 15 1/2 1 1 16 R3015-1-1P3-B2 15 1/2 1 1.3 16 R3015-1P3-P25-B2 15 1/2 1.3 0.25 16 R3015-1P3-P4-B2 15 1/2 1.3 0.4 16 R3015-1P3-P63-B2 15 1/2 1.3 0.63 16 R3015-1P3-1-B2 15 1/2 1.3 1 16 R3015-1P3-1P3-B2 15 1/2 1.3 1.3 16 R3020-P63-1P6-B2 20 3/4 0.63 1.6 16 R3020-P63-2P5-B2 20 3/4 0.63 2.5 16 R3020-1-1P6-B2 20 3/4 1 1.6 16 R3020-1-2P5-B2 20 3/4 1 2.5 16 R3020-1P6-P63-B2 20 3/4 1.6 0.63 16 R3020-1P6-1-B2 20 3/4 1.6 1 16 R3020-1P6-1P6-B2 20 3/4 1.6 1.6 16 R3020-1P6-2P5-B2 20 3/4 1.6 2.5 16 R3020-2P5-P63-B2 20 3/4 2.5 0.63 16 R3020-2P5-1-B2 20 3/4 2.5 1 16 R3020-2P5-1P6-B2 20 3/4 2.5 1.6 16 R3020-2P5-2P5-B2 20 3/4 2.5 2.5 16 R3020-2P5-4-B2 20 3/4 2.5 4 16 R3020-4-2P5-B2 20 3/4 4 2.5 16 R3020-4-4-B2 20 3/4 4 4 16 PN www.belimo.eu R30..-..-..-B2 en-gb 2016-01-25 subject to changes 1

Technical data Functional data Media Cold and warm water, water with glycol up to max. 50% vol. Medium temperature 6...80 C Functional data Permissible pressure ps 1600 kpa Differential pressure pmax 100 kpa Differential pressure note low-noise operation pv100 < 50kPa Flow characteristic Linear Leakage rate Leakage rate A, air-bubble-tight (EN 12266-1) Pipe connector Internal thread according to ISO 7-1 Angle of rotation Sequence 1: 0...30 (Cooling recommended) Dead zone: 30...60 Sequence 2: 60...90 (Heating recommended) Angle of rotation note with room controller CRK24-B1 compelling sequence 1 = cooling and sequence 2 = heating Installation position Upright to horizontal (in relation to the stem) Maintenance Maintenance-free Materials Housing Brass body nickel-plated Closing element Chrome-plated brass Stem Nickel-plated brass Stem seal O-ring EPDM Ball seat PTFE, O-ring EPDM Flow rate diaphragms rostfreier Stahl Safety notes! The valve has been designed for use in stationary heating, ventilation and airconditioning systems and must not be used outside the specified field of application, especially in aircraft or in any other airborne means of transport. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. The valve does not contain any parts that can be replaced or repaired by the user. The valve may not be disposed of as household refuse. All locally valid regulations and requirements must be observed. When determining the flow rate characteristic of controlled devices, the recognised directives must be observed. Product features Mode of operation Pressure compensation The 6-way characterised control valve is adjusted by a rotary actuator. The actuator is connected by a modulating control system or a MP-Bus signal and moves the ball of the ball valve to the position dictated by the positioning signal. If the valve is adjusted in the clockwise direction (till the end stop), e.g. the cooling sequence is completely enabled; if the valve is adjusted in the counter-clockwise direction (90 ), e.g. the heating sequence is completely enabled. In cases of combined heating/cooling control elements, the medium remains in the control element when in the closed position (no heating or cooling). The pressure of the enclosed medium can rise or fall due to changes in medium temperature caused by the ambient temperature. The 6-way characterised control valves have an integrated pressure relief function for the purpose of compensating for such pressure changes. The pressure relief function is active in the closed position (45 ) of the valve; reliable separation of Sequences 1 and 2 continues. For additional information, consult the notes for project planning for the 6-way characterised control valve. 2 R30..-..-..-B2 en-gb 2016-01-25 subject to changes www.belimo.eu

Accessories Description Mechanical accessories Pipe connector to ball valve DN 15 1/2 ZR2315 Fastening angle, for 6-way control valves ZR-004 Pipe connector to ball valve DN 20 3/4 ZR2320 Installation notes Recommended installation positions The ball valve can be installed upright to horizontal. The ball valve may not be installed in a hanging position, i.e. with the stem pointing downwards. 90 90 Water quality requirements Maintenance Flow direction The water quality requirements specified in VDI 2035 must be adhered to. Belimo valves are regulating devices. For the valves to function correctly in the long term, they must be kept free from particle debris (e.g. welding beads during installation work). The installation of suitable strainer is recommended. Ball valves and rotary actuators are maintenance-free. In the event of any service work on the final controlling device, it is essential to isolate the rotary actuator from the power supply (by unplugging the electrical cable). Any pumps in the part of the piping system concerned must also be switched off and the appropriate slide valves closed (allow everything to cool down first if necessary and reduce the system pressure to ambient pressure level). The system must not be returned to service until the ball valve and the rotary actuator have been properly reassembled in accordance with the instructions and the pipeline has been refilled in the proper manner. The flow direction must be observed. The position of the ball can be identified from the L-marking on the stem. Heating and cooling in position accuracy I II 100% 100% www.belimo.eu R30..-..-..-B2 en-gb 2016-01-25 subject to changes 3

Installation notes Valve characteristic curve The lower diagram shows the valve characteristic curve in relation to the ball position. Valve characteristic curve 0 45 90 kv 30 30 0 45 90 α Dimensions / Weight Dimensional drawings min. Y 42 H H1 H2 min. X 43 L2 L1 32 M4 B1 L 22 12 B The actuator dimensions can be found on the respective actuator data sheet. DN [ ] L L1 L2 B R3015-..-..-B2 15 1/2 79 39.5 13 54 33 119 45 47 200 40 1.1 R3020-..-..-B2 20 3/4 100 50 14 70 43 148 59 54 230 40 2.1 B1 H H1 H2 X Y Weight [ kg] 4 R30..-..-..-B2 en-gb 2016-01-25 subject to changes www.belimo.eu

Further documentation Overview Valve-actuator combinations Data sheets for actuators Installation instructions for actuators and/or ball valves Notes for project planning for 6-way characterised control valves www.belimo.eu R30..-..-..-B2 en-gb 2016-01-25 subject to changes 5