Yoke Block Instruction Manual

Similar documents
Yoke Block Instruction Manual

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

MOBILE E TANK STAND INSTALLATION AND INSTRUCTIONS

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

PORTER INSTRUMENT COMPANY, INC.

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

453 Series Steam Heated Vaporizing Regulator

D Series Air and Water Kit Part# 02550

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

NITRONOX SCAVENGER SYSTEM USER S MANUAL / INSTRUCTIONS

ROPV R40 E Series User Manual

- GAS REGULATOR - COMPACT STYLE

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

J Air and Water Kit Instructions Part# 02584

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

FLANGED TWO-PIECE BALL VALVES

User Instruction Manual

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

OPERATOR S MANUAL. Fabric Grass Catcher PART NO PRINTED 1/2011 PRINTED IN USA

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

OPERATOR'S MANUAL GRASS CATCHER GC-4D

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

SOTR Special Operations Tactical Respirator

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

SERVICE MANUAL. Technical Bulletin No GEOPROBE GH40 HYDRAULIC HAMMER. PREPARED: February, REVISED: April, 2002 A DIVISION OF KEJR, INC.

Blendox AII5000F Inhalation Antalgic System. User s Manual :SP-Y Series No. Version :A1. Date of Review:

NITRONOX USER S MANUAL

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

Freedom8 ShoeBox Compressor Manual

OPERATOR'S MANUAL. MODEL GC-F4 Fabric Grass Catcher P/N 9055 GRASS CATCHER GC-F4. PART Rev.2 SC301G

CSA Sample Draw Aspirator Adapter Operator s Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

User Operation Manual and Safety Instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

FLANGED TWO-PIECE BALL VALVES

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

Models: C62/63/64-A/D

Index Table. Model 794. Installation, Operating and Maintenance Instructions

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

1000-Lb. Rapid Lift Hydraulic Table

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Interface Devices, Inc. Hydraulic Mini Mule

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

OWNER'S MANUAL. Copyright 1999 ATS - All Rights Reserved

AND OPERATION INSTRUCTIONS

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

MANUAL BE SERIES Test Benches

Duo/Trio Office Bike Owner s Manual

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

GETZ EQUIPMENT INNOVATORS RECOVERY SYSTEM CLEAN AGENT FE-36 / HALOTRON 1 PART NO. 4G59751 OPERATIONS MANUAL

Pressure Relief Valve Instruction Manual

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS 6K Puller (M6K-M)

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

Foldable Magne c Exercise Bike

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

G7S Hand Pump Owner s Manual

Protocol Switchover Station

Installation, Operation and Maintenance Manual

RG1200 Service and Repair Manual

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

MODEL SC401 DUAL CYLINDER SCALE

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

600 / 600FC OWNER'S MANUAL

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

STANDARD FLOWMETER USER S MANUAL

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

602 STRINGING MACHINE OWNER'S MANUAL

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

Float Operated Level Controllers

Sunset Swings By Health in Motion, LLC

MANUAL: Jumbo Siamese and Jumbo Wye

PORTABLE AFTERCOOLER MODEL CA-700 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL ORIGINAL INSTRUCTIONS

Transcription:

Yoke Block Instruction Manual

! WARNING IMPORTANT: READ MANUAL COMPLETELY BEFORE OPERATING THIS DEVICE This manual contains instructions on periodically required checks to be performed by the user. These checks are necessary to ensure the proper performance of this device and its safety features. RETAIN THIS MANUAL FOR FUTURE REFERENCE CAUTION: Federal law requires this device for use by or on the order of a physician or dentist. CAUTION: Do not attempt to repair or alter this device. Unauthorized repair, alteration or misuse of this device is likely to adversely affect the performance and will void the warranty. CAUTION: Never oil or grease any part of this system. The National Institute for Occupational Safety and Health has issued a warning for dental workers exposed to N2O during administration of N2O/O2 conscious sedation analgesia. NIOSH has recommended that exposures should be minimized. Contact NIOSH to receive NIOSH Publications on Control of Nitrous Oxide in Dental Operatories at 1-800- 232-4036. Exposure can be minimized by effective controls, including System Maintenance, Ventilation, and Work Practices can effectively reduce N2O concentrations in dental operations. A scavenger system is a significant part of exposure control. 1

Index Assembly of Yoke Block Stand...4-6 Cylinder Attachment to Yoke Block...8 Cylinder Detail...10 Cylinder Seals...9 Dimensions...7 Parts List...3 Pin Safety System...12 Purchase Record...13 Supply Hose Connection...7 Turning the Cylinder On/Off...11 Warnings...1 Warranty...14 Yoke Block Leak Test...12 2

Parts List 1. Base with Casters 2. Column 3, Yoke Block 4. Adjustment Knob 5. Yoke Block Mounting Screws 6. Z Bracket 7. Adjustment Rod with Locking Nuts 8. O2 Hose 9. N2O Hose 10. Flowmeter Mounting Screws 11. Yoke Plug 12. Cylinder Wrench 1 2 3 4 5 6 7 8 9 10 11 12 3

Assembly of Yoke Block Stand! Read all instructions before assembly and use of this product. WARNING: Failure to follow these warnings and instructions could result in serious injury or death. 1. Place column in base with casters 2. Line up four holes of Yoke Block 3. Attach Yoke Block to column with Yoke Block mounting screws. Use 5/32 hex key 4

Assembly of Yoke Block Stand (cont.) 4. Screw in height adjustment knob 5 turns 5. Rotate Yoke Block, with height adjustment knob in line with one of the stand legs, as pictured 6. Remove acorn nut and jam nut from height adjustment rod 7. Place Z bracket on top height adjustment rod 8. Hand tighten locking nut onto adjustment rod 9. Tighten acorn nut onto adjustment rod using 3/4 wrench 5

Assembly of Yoke Block Stand (cont.) 10. Mount Flowmeter head to Z Bracket using 2 Flowmeter mounting screws. Use 1/8 hex key 11. Place adjustment rod into column. Tighten adjustment height knob! Adjustable height knob must be kept tight except when adjusting the height of the flowmeter 6

Supply Hose Connections 12. Connect the supply hoses! Use two wrenches yoke block regulator PC-7 Flowmeter (not included in all packages) O2 (green) DISS hose N2O (blue) Dimensions 31 22 19! Remember: always keep adjustable knob tight except when adjusting the height of the flowmeter 7

Cylinder Attachment to Yoke Block Introduce E cylinder into yoke, making sure that the gas and yoke are the same. Note the two index pin holes are facing in, towards yoke block; match the pins in yoke to holes in cylinder valve and push against seal in yoke. Tighten cylinder into yoke by turning yoke tee handle clockwise. Complete this procedure with any additional cylinders if necessary. Using cylinder wrench supplied with yoke block, attach to oblong shaped tip located on top of cylinder valve. Turn 1/2 turn counter-clockwise (left) to open (a clockwise turn to right will close cylinder valve). Flowmeter is now ready to operate. Always turn cylinder valves off when not using machine. Replace O2 cylinders when gauge pressure is 200psi (Full cylinder pressure is approx. 2000psi.) Replace N2O cylinders when gauge pressure is 500psi. (Full N2O cylinder pressure is 750psi.) In the event only one cylinder of gas is used, a plug is supplied, to be used in yoke, in place of the cylinder. cylinder seal face of yoke gas nipple safety pin indexing for proper gas (prevents attaching incorrect gas in yoke) turn wheel cylinder yoke 8

Cylinder Seals ***FDA and NIOSH have recommended that plastic crush gaskets never be reused.*** FDA and NIOSH have also issued the following general safety precautions to avoid explosions, tank ruptures, and fires from oxygen regulators. 1. Always crank cylinder valves (open the valve just enough to allow gas to escape for a very short time) before attaching regulators in order to expel foreign matter from the outlet port of the valve. 2. Always follow the regulator s manufacturer instructions for attaching the regulator to an oxygen cylinder. 3. Always use the sealing gasket specified by the regulator manufacturer. 4. Always inspect the yoke to ensure it is in good condition and equipped with only one integral metal and rubber seal that is in good condition. AVOID PLASTIC SEALS. 5. Tighten the turn wheel firmly by hand, but DO NOT use wrenches or other hand tools that may over-torque the handle. 6. Open the post valve slowly, while maintaining a grip on the valve wrench so that it can be closed quickly if gas escapes at the juncture of the seal and valve. It is our recommendation that plastic seals be avoided. Plastic seals of this type may have been supplied with small cylinders. DO NOT USE THESE SEALS. An alternate seal of Metal/Viton configuration is recommended for all applications and is available under our part #5404-0001. All Belmed, Inc. yoke blocks are equipped with this seal. To order Metal/Viton washers please contact your dealer. Improper Nylon Washer 9 Metal/Viton Washer Part #5404-0001

Cylinder Detail cylinder stem face of cylinder cylinder port cylinder shut-off valve holes that accept pins E cylinder 10

Turning the Cylinder On/Off valve stem Place cylinder wrench on stem. Turn counter clockwise for on and clockwise for off. Note: Make sure cylinder is tight in yoke 11

Pin Safety System yoke oxygen nitrous oxide Small cylinder non-interchangeability is accomplished with the Pin Index System. This system uses two positioning holes on the cylinder valve and two corresponding pins on the yoke. Yoke Block Leak Test Start test with no pressure in system, gauge on yoke block at zero and flowmeter turned off. Make sure supplied cylinder seals are in place and cylinders are tight in yokes. Quickly open cylinder valve, tapping gas in lines. Observe gauge pressure for line being tested. Gauge pressure should remain constant with no pressure drop. If gauge pressure drops, recheck all connections for tightness. To isolate leaks, we recommend oxygen safe liquid leak detector available from a plumbing supply or hardware store. Use as directed on all connections, fittings, etc. Relieve system pressure and repeat procedure with other cylinder(s). 12

Purchase Record MODEL NO. SERIAL NO. PURCHASE DATE Notes 13

Warranty Definition of Warranty Return: A product or part covered by the Belmed, Inc. warranty, that fails while the terms of the warranty are in effect. THIS WARRANTY IS GIVEN IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. No statement or claim about the product by any employee, agent, representative or dealer of Belmed, Inc. shall constitute a warranty by Belmed, Inc. or give rise to any liability or obligation of Belmed, Inc. Subject to the next sentence, Belmed, Inc warrants that each product or part shall be free from defects in workmanship and materials, under normal use and with appropriate maintenance, for one (1) year from the date of delivery to customer. For plastic, rubber and disposable parts or items Belmed, Inc. warrants only that each such part and item shall be free from defects in workmanship and materials at the time of delivery to the customer. Belmed, Inc. s obligation for breach of this warranty, or for negligence or otherwise, shall be strictly and exclusively limited to Belmed Inc. s choice of repair or replacement of the product or part. This warranty shall be void for any product on which the serial number has been altered, defaced or removed. Belmed, Inc. shall not be liable for any damage, injury or loss arising out of the use of the product, whether as a result of a defect in the product or otherwise, if, prior to such damage, injury or loss, the product was (1) damaged, misused, or misapplied; (2) repaired, altered or modified by persons other than Belmed, Inc. (3) not installed in strict compliance with applicable codes and ordinances; or (4) not installed by Belmed, Inc. or an authorized Belmed, Inc. dealer. UNDER NO CIRCUMSTANCES SHALL BELMED, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES AS THOSE TERMS ARE DEFINED IN THE UNIFORM COMMERCIAL CODE. 14

Order: orders@belmedinc.com Fax: 717-246-7586 Mail To: PO Box 247 Red Lion, PA Ship To: 887 Delta Rd Red Lion, PA Contact Us: Local: 717-246-5500 Toll Free 888-723-5893 bmi@belmedinc.com Tech Support: help@belmedinc.com www.belmedinc.com 501-005 V2