Rada sikkerhetsblander, modell 32E M. Best. nr: R NRF-nr:

Similar documents
320 c PRODUCT MANUAL IMPORTANT

SHOWER FITTINGS INSTRUCTIONS AND MAINTENANCE GUIDE. Please read carefully before use

V12 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

PRODUCT MANUAL IMPORTANT

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

Twin & Triple Control Concealed Thermostatic Shower Valve

215 and 222 Series PRODUCT MANUAL

SMV-001 Thermostatic Shower Mixer Valve Installation Instructions & Adjustment Settings

Rada-Presto TF2020 and TF2020S

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Installation, commissioning and servicing instructions

These instructions must be left with the user

Installation, commissioning and servicing instructions

Scald Protection Three-Way Thermostatic Mixing Valve

Deluge Optimo Shower valve and kit 10032CP

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

Rada Sense Shower T3 DMV PRODUCT MANUAL IMPORTANT

PRODUCT MANUAL IMPORTANT

These instructions are to be left with the user

15/3 THERMOSTATIC MIXING VALVE PRODUCT MANUAL IMPORTANT

Self-help Temperature Adjustment

Ligature Resistant Head

Scald Protection 3-Way Thermostatic Mixing Valve

Mira Select. Installation & User Guide. These instructions must be left with the user. 1

These instructions must be left with the user.

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

These instructions must be left with the user.

MIRA ELEMENT SLT THERMOSTATIC MIXER INSTALLATION AND USER GUIDE. These instructions must be left with the user.

TMV20 THERMOSTATIC MIXING VALVE

215-t3/222-t3 SERIES

MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only)

These instructions are to be left with the user

215 SERIES. NSW Health approve the Rada 215 series TMV for use in healthcare buildings. PRODUCT MANUAL IMPORTANT

OWNER S GUIDE DUAL CONTROL THERMOSTATIC SHOWER VALVE. Shower Control. may differ depending on choice of Model. Concealing Plate. Handles and ISSUE 01

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

Mira Mode Digital Mixing Valve

TEMPERATURE STABILISED THERMOSTATIC SHOWER PANEL

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

MANUAL FOR INSTALLATION, COMMISSIONING AND MAINTENANCE FOR

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Horne Engineering Ltd

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

553 Series.

INSTALLATION INSTRUCTIONS

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Installation, commissioning and servicing instructions. General

These instructions must be left with the user.

These instructions are to be left with the user

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

These instructions are to be left with the user

HORNE 20 THERMOSTATIC MIXING VALVE TYPE H-2003

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

LRS(H)4 Pressure-Reducing Regulator User Manual

AQUABLEND MM THERMOSTATIC MIXING VALVE

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED

Intamix Thermostatic Mixing Valve

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Bar valve with fixed shower head Installation guide

AQUABLEND 2000 THERMOSTATIC MIXING VALVE

FIREFIGHTING EQUIPMENT

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

AQUABLEND 1500 THERMOSTATIC MIXING VALVE WITH THERMAL FLUSH

These instructions are to be left with the user

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

RD(H)20/25 Pressure-Reducing Regulator User Manual

Thermostatic Concentric Mixer Valve. with Exposed and Concealed Fitting Options. Fitting Instructions

DelVal Flow Controls Private limited

DS05C,D,G Dial Set Pressure Regulating Valves

Model TWBS.SH Tempered Water Blending System

Atmos Low Pressure Thermostatic Bar Mixer Valve

Options Concentric Petite

Atmos Zone. Thermostatic Concealed Concentric Mixer Valve with Fixed Head. Fitting Instructions

VB85/ Pressure regulating valve (Unloader)

INSTALLATION GUIDELINES

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

Model VR6 System. Installation, Operation & Maintenance

These instructions must be left with the user

These instructions must be left with the user

These instructions must be left with the user

Installation, commissioning and servicing instructions

INSTALLATION, OPERATING AND MAINTENANCE GUIDE FOR EXPOSED AND CONCEALED MODELS MODERN, TRADITIONAL AND MINIMALISTIC

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Manual Actuated Boiler Blowdown Valves

Service and Repair Manual

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

Training. Testor Training Manual

WW-720. Pressure Reducing Control Valve

Mainsboost Installation, Operation & Maintenance Instructions

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Transcription:

Rada sikkerhetsblander, modell 32E M Best. nr: R1812-016 NRF-nr: Anslutning: DN 20 ¾ RG Vannmengde: 120 l/min. Vanntrykk: min. 2,7 bar, maks. 6,9 bar Termostatisk sikkerhetsblander (dobbel termostat) Forhåndsinnstilt på 25 C (ikke justerbar) Kompenserer for trykk- og temperaturvariasjoner. Innebygget kaldtvann by-pass som slipper gjennom kaldt vann dersom det varme vannet forsvinner. Ved bortfall av kaldt vann stenger ventilen automatisk. Leveres med tilbakeslagsventiler. Vestnor Teknikk AS, Nyeveien 49 B, 4370 Egersund Tlf: 51498060, Epost: post@vestnorteknikk.no Internett: www.vestnorteknikk.no

E 32E Product Manual Installer: This manual is the property of the customer and must be retained with the product for maintenence and operational purposes. 1 1290447-W2-A

1290447-W2-A 2

32E X 1 q X 1 q X 1 q X 2 q X 1 q X 1 q X 1 q X 2 q X 3 q 3 1290447-W2-A

32E BSP X 1 q X 1 q X 1 q X 1 q X 3 q 1290447-W2-A 4

32E RADA 320 C 61 mm 41.5 mm Ø83.5 mm 49 mm 59 mm 127.5 mm 49 mm 185 mm 256 mm 314.5 mm 32E BSP 137 mm RADA 320 OEM Ø83.5 mm 49 mm 117 mm 49 mm 185 mm 5 1290447-W2-A

Rada 32E Rada 32E series has been designed specifically to provide temperature controlled water to emergency fixtures. Tepid flushing fluid is considered necessary in all types of emergency equipment applications. Tepid is defined in the standard (DIN CN 15154-2), as "A flushing fluid temperature conducive to promoting a minimum 15-minute irrigation period. A suitable range is 16-37 C. Generally, temperatures higher than 37 C may cause chemical interactions with the skin and result in further damage. At 16 C and below hypothermia becomes a concern. Consulting a safety/health advisor will be a helpful aid in the determination of the best temperature parameters. No two hazards are exactly the same and each should be evaluated on a case-by-case basis". Point of Use Rada 32E Thermostatic Mixing Valves are suitable for installation at or near a point of use for direct tepid water supply to an emergency fixture or grouping of fixtures. Groups of fixtures must meet the valve s flow capacity requirements if there is a potential for simultaneous operation. Rada 32E Filter Installation Schematic 1290447-W2-A 6

Rada 32E Rada 32E is a Thermostatic Mixing Valve of sealed for life disposable cartridge construction. For Emergency Drench Showers - The Rada 32E will pass a specified minimum of 76 litres per minute (l/min) and will flow a minimum of 38 l/min from direct cold water supply in hot failure mode at 2.7 bar (40 psi) maintained equal inlet supply pressure. For Emergency Eye Wash Stations - For single or multiple fixture installation, the Rada 32E will control accurately at flow rates from 76 to 8 l/min. In flow applications between 76 and 38 l/min, the Rada 32E will pass approximately 50% of original flow setting in hot failure mode. In flow applications between 38 and 19 l/min, the Rada 32E will pass approximately 80% of original flow setting in hot failure mode. In flow applications below 19 l/min, the Rada 32E will pass approximately 95% of original flow setting in hot failure mode. Operational Specifications 1. Site Adjustable Mechanical maximum-temperature limit stop and single-temperature locking features as a function of the temperature control handle design. 2. Thermal shutdown feature is designed to protect user from unsafe water temperatures or hot water/chemical reaction should cold supply be interrupted during use. 3. Unique constant cold water flow design ensures that in the event of a hot supply failure the Rada 32E will allow cold water to flow to fixture. 4. Unique constant cold water flow feature allows the inlet hot water supply to be set within a prescribed range, thus limiting the potential outlet temperature to a safe maximum in the event of misadjustment, unauthorized tampering or thermostat failure. This feature presumes that the correct initial commissioning was performed and that the cold water supply has not been interrupted. Technical Specifications 32E - 1 BSP Female or 28 mm Compression 32E BSP - 3/4 BSP Male Chrome-plated DZR brass/polymer construction Operating pressures must be nominally equal Maximum: Minimum: 6.9 bar* 2.7 bar drench showers, 1.4 bar eye wash Integral replaceable cartridge-type inlet check valves Dual thermostatic elements Integral replaceable inlet strainers 38 LPM constant cold water flow in hot failure mode to open outlet at 2.7 bar pressure drop *High water pressures may deliver a volume and spray force that are injurious to the user. Check with fixture manufacturer or regulate water pressures within acceptable range. 7 1290447-W2-A

Safety Warnings The function of a Thermostatic Mixing Valve is to deliver water consistently at a pre-designated temperature. Rada Thermostatic Mixing Valves are precision engineered to give continued superior and safe performance provided: 1. They are installed, commissioned, operated and maintained in accordance with the recommendations provided and accepted plumbing practices. 2. Periodic attention is given, as necessary, to maintain the product, the accessory fittings and the plumbing system in good functional order. In keeping with every other mechanical product, Rada Mixing Valves should not be considered as functionally infallible and, as such will never totally replace the vigilance and attention of maintenance, supervisory and safety staff. Provided that they are installed, commissioned, operated and maintained, the risk of product failure and its associated consequences, if not eliminated, are reduced to the minimum achievable. Rada 32E Operating Specifications Maximum Hot Water Supply Temperature 85 C Minimum Cold Water Supply Temperature 1 C Minimum Flow Rate at mid blend with nominally equal supply pressures. Maximum Flow Rate Maximum Dynamic Inlet Supply Pressure (supplies must be nominally equal) MAximum Static Pressure Minimum Inlet Supply Pressures 8 l/min 120 l/min 6.9 bar 10 bar 2.7 bar Drench Shower 1.4 bar Eye Wash Caution! High water pressures may deliver a volume and spray force which is injurious to the user. Check with fixture manufacturer or regulate water pressures within acceptable range. Warning! Correct on site commissioning of Rada 32E is critical. Warning! The constant cold water flow design ensures that in the event of a hot water supply failure the Rada 32E will allow cold water to flow to the fixture. In addition, Rada 32E is designed to shutdown the hot water supply in the event of a cold water supply failure. These features will only function if: 1. There is a minimum of 20 C differential between the Hot Supply and the Blend set point 25 C. 2. The Rada 32E has been factory set to deliver a maximum temperature at 25 C. It is critical to note that under certain inlet temperature supply conditions, the constant cold water supply feature may give the false impression that a blend set point has been correctly established. However, the blend temperature may just be a function of the combination of inlet hot water temperature and the constant cold water flow. Important! The valve may actually be inadvertently set to deliver temperatures well in excess of the set point but it is unable to do so due to the constant cold water flow. In this situation the cold water failure safety shutdown has been compromised. 1290447-W2-A 8

Rada 32E Installation The Rada 32E Thermostatic Mixing Valve must be installed as per the Installation Schematic. 1. The Rada 32E should be installed in a horizontal position. 2. The Rada 32E must be installed in a standard HOT-LEFT/COLD-RIGHT inlet supply configuration. There are red(hot) and blue(cold) markings on each valve. 3. Be sure to thoroughly flush the pipework before fitting the Rada 32E. 4. Do not expose the Rada 32E or any of its fittings to extreme temperatures. 5. The Rada 32E is serviced from the front of the valve as you face it. A minimum 180 mm clearance in front of the Temperature Control Handle is suggested for internal parts access. 6. The Rada 32E is pre-set at the factory to a 25 C Blend outlet temperature. The RADA 32E MUST NOT BE TEMPERATURE ADJUSTED ON-SITE. 7. The Rada 32E is designed to control a single drench shower or combination drench shower/eye wash station. 8. The Rada 32E is designed to control a single eye wash station. Multiple eye wash stations can be controlled by a single Rada 32E as long as the potential multiple simultaneous demand does not exceed valve capacity. 9. Ensure that the inlet supply pressures are nominally equal. 6.0 mm 3.0 mm 9 1290447-W2-A

1 b a 3.0 mm 2 6.0 mm 6.0 mm 1290447-W2-A 10

3 Install the connections 32E 32E BSP 4 1 min 11 1290447-W2-A

5 3.0 mm 6 Install the pipework a 32E 1290447-W2-A 12

b 32E BSP 7 32E shown. The rest of the installation procedure is similar for all variants of the 32 valve. 13 1290447-W2-A

8 Commissioning the Rada 32E Commissioning must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. Temperature Checking The blend temperature obtainable through the mixing valve should be limited to prevent selection of a flushing temperature that is too hot. The Rada 32E is fully performance tested and then pre-set at the factory to a 25 C blend outlet temperature. TEMPERATURE SHOULD NOT BE ADJUSTED. Check that an adequate supply of hot water is available at the hot inlet of the mixing valve. For optimum performance the minimum temperature of the hot water must be at least 20 C above the blend. Validate The Commissioning It is important that the commissioning is validated. Proceed as follows: 1. Operate the fixture(s) at full flow and take a temperature reading. Water temperature should not fluctuate more than 4 C. If water temperature control is unsatisfactory, refer to Fault Diagnosis. 2. Operate the fixture(s) at full flow and intentionally fail the hot water supply to the Rada 32E. Cold water should continue at a reduced flow rate. Confirm that the cold water flow rates meet the specifications. If cold water does not flow, refer to Fault Diagnosis. 1290447-W2-A 14

3. Operate the fixture(s) at full flow and intentionally fail the cold water supply to the Rada 32E. All flow through the fixture should shut off completely within 2 seconds. If flow does not shut off to specification, refer to Fault Diagnosis. For optimum performance and safety repeat steps 1-3 as a part of a regularly scheduled test and validation program. Record and report any variations to the Plant Management and the Plant Safety Officer. Servicing and Maintenance Rada 32E Thermostatic Mixing Valves should be inspected and tested on a regular schedule. Acknowledged site conditions such as high mineral content water may dictate an increased frequency. It is highly recommended that as a function of the annual inspection that the two Oval shaped Seals within the valve are replaced. Note! All seals are pre-lubricated. If further lubrication is required, use only silicone based lubricants on this product. Do not use petroleum based lubricants. The Rada 32E Thermostatic Mixing Valve is of non-serviceable single cartridge construction. The cartridge can be removed from the valve for inspection or replacement by first removing the temperature control handle using a 3 mm hex wrench. The hub assembly may inadvertently remain attached to the inside of the temperature control handle. This is a push fit and can be levered out using a thin blade screwdriver or pliers. Warning! The Rada 32E has a specially designed replacement cartridge. Important! Do not install a replacement cartridge which does not have the 32E identifier. The Temperature Indicator Ring, which fits beneath the temperature control handle can be levered off using a suitable thin edged tool. Before proceeding further be sure to isolate the valve by turning off each inlet supply. The complete cartridge assembly is accessed by first removing the 6 retaining screws and then smoothly drawing the cartridge out. Do not twist or apply side load leverage when extracting the cartridge. When installing a new or reinstalling an existing cartridge note the raised H on the hot inlet of the cartridge and align to hot supply accordingly. Important! After re-installing a replacement cartridge, the Rada 32E must be re-commissioned and validated. Warning! The Rada 32E Cartridge Assembly is non-serviceable. Do not attempt to disassemble the cartridge or tamper with the factory settings beyond those detailed in this product manual. 15 1290447-W2-A

Maintenance Procedure - Cartridge Replacement 1 2 4 Identification Label Fixed Here WARNING! This cartridge is only suitable for use with the 32E Emergency Shower at low blend temperatures 25 C or below. Do not use in any other product. F17170/1 Kohler Mira Limited, Jan 2017 F17170_1 32E Warning Label.indd 1 09/01/2017 09:04:11 5 6 1290447-W2-A 16

7 WARNING! This cartridge is only suitable for use with the 32E Emergency Shower at low blend temperatures 25 C or below. Do not use in any other product. F17170/1 Kohler Mira Limited, Jan 2017 8 Identification Label Fixed Here WARNING! This cartridge is only suitable for use with the 32E Emergency Shower at low blend temperatures 25 C or below. Do not use in any other product. F17170/1 Kohler Mira Limited, Jan 2017 Important! Do not remove hub when fitting the spare cartridge. Temperature Factory preset must not be adjusted 17 1290447-W2-A

Spare Parts 414.80 Identification Label Fixed Here 1812.007 414.92 A A A 1812.013 1847.242 1847.184 1847.236 1847.235 1847.232 1847.233 32E - 1847.153 32E BSP - 1847.093 A A X4 No: Description 1812.007 Cartridge Assembly 414.80 Hub Pack 1847.24 Backplate 1847.242 Knob Pack 523.19 Compression Fitting - Not Illustrated 1847.093 (3/4" BSP) Connector Pack 1847.153 Elbow Connection Pack 1847.184 Isolating Elbow Pack 1847.227 Seal Pack - Not illustrated 1847.229 Screw Pack - 'A' 1812.013 Indicator Trim 1847.233 (3/4") 1847.232 (1-1/4") 1847.235 (3/4") 1847.236 (1-14") Inlet Service Pack Filter Pack x 2 Filters 1290447-W2-A 18

Fault Diagnosis Symptom 1. Only Hot or Cold Water From Outlet 2. Fluctuating or Reduced Flow Rate 3. No Flow From Mixing Valve Outlet Cause/Action a. Inlet supplied reversed (i.e. hot supply to cold inlet) can be diagnosed by isolating the inlet supplies and removing the valve cartridge. With cartridge removed, turn the water on at each supply individually and at a very low flow rate (water will run out of the front of the valve body). Identify which inlet is the hot supply and which is the cold supply. Re-install the cartridge matching the raised H and C on the cartridge body to the inlets as identified. b. No hot water reaching mixing valve. Check c. Check strainers and inlet fittings for blockage. d. Refer to symptom 5 below. e. Installation conditions continuously outside operating parameters f. Normal function of mixing valve: indicates hot water inlet supply failure/ interruption. Normal function of mixing valve when operating conditions are unsatisfactory. a. Check strainers and inlet/outlet fittings for flow restriction. b. Ensure that minimum flow rate is sufficient for supply conditions. c. Ensure that dynamic inlet pressures are nominally balanced d. Ensure that inlet temperature differentials are sufficient. e. (Subject to rectification of supply conditions). Check the thermostatic performance; renew cartridge assembly if necessary. f. Normal function of mixing valve: indicates hot water inlet supply failure/ interruption. Check that inlet flow controls are fully open. a. Check strainers and inlet/outlet fittings for blockage. b. Cold supply failure; thermostat holding correct shutdown function: rectify, and return to 2e above. 4. Blend Temperature Drift Indicates operating conditions changed. 5. Hot Water in Cold Supply or Vice-Versa a. Refer to symptom 2 above. 6. Water Leaking form Valve Body Seal (s) worn or damaged. 7. Cold Water does Not Flow After Hot Supply Failure 8. Hot Water continues to Flow After Cold Supply Failure b. Hot supply temperature fluctuation (rectify and refer to Commissioning). c. Supply pressure fluctuation (rectify and refer to Installation). Indicates check valves require maintenance (refer to Maintenance). a. Obtain seal pack, renew all seals. b. (If leak persists from around temperature spindle). Renew cartridge assembly. a. Incorrect valve model installed. Check and rectify. b. Incorrect internal cartridge installed. Check identification code and rectify c. Check strainers and inlet/outlet fittings for blockage d. Cold supply failure. a. Incorrect Valve commissioning. Validate the Commissioning. b. Insufficient temperature differential see validate commissioning. 19 1290447-W2-A

Customer Service Rada Products Customer Services Guarantee Your product has the benefit of our manufacturer s guarantee which commences from date of purchase or from the date of commissioning when product commissioning has been conducted within the UK by the Rada Commercial Field Service Team. Please contact your local agent for all guarantee terms and conditions or visit www. radacontrols.com for further information. For UK (only) Customer Service & Post Installation enquiries, including details of the Rada Commissioning, Responsive and Maintenance Contract Service Packages please contact: Telephone: 0844 571 1777 Please Note! Calls cost 7p per minute plus your phone company s access charge Fax: 01242 282595 Email: radacustomerservices@mirashowers.com or visit www.radacontrols.com By Post: Rada Controls, Cromwell Road, Cheltenham, Gloucestershire GL52 5EP For UK (only) Pre-Specification Enquiries please contact: Telephone: 0844 571 1777 Please Note! Calls cost 7p per minute plus your phone company s access charge Fax: 01242 282404 E-mail: rada_technical@mirashowers.com or visit www.radacontrols.com By Post: Rada Controls, Cromwell Road, Cheltenham, Gloucestershire GL52 5EP For Eire Only Telephone: 01 531 9337 Email: CustomerServiceEire@mirashowers.com 1290447-W2-A 20 Kohler Mira Limited, December 2016