PRODUCT CONFIGURATOR AT mcr Monsun. smoke extraction and air supply axial-flow fans

Similar documents
mcr Monsun TECHNICAL MANUAL Smoke exhaust axial fan Version: Monsun FIRE VENTILATION SYSTEMS

CJTX-C 15/15 0,75 (2V) F-400. Impeller size 2-speed fan. Installed power. (r/min) 230 V 400 V 690 V (kw) m3/h db(a) (kg)

TECHNICAL DESCRIPTION

SMOKE EVACUATION FANS OUTSIDE THE HAZARDOUS AREA

COMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Centriflow Plus High-pressure plug fan - Technical Data

Liquid ring vacuum pumps single-stage

VENTILATOR OPTIONS. Please visit our web page to view all the available options and for a specification.

VISIMIX TURBULENT. MECHANICAL CALCULATIONS OF A CONSOLE SHAFT

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

Technical information

Geo-Vibro Corer

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

KSB Delta Compact Type Series Booklet

UCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES

Fan and air movement essentials

Mixers. Venturi proportional mixers EMM & EMMTR (E2351 rev /07/2017)

Less power great performances

Turbo Blowers. Combustion Excellence Since Features. Benefits

KSB Delta Compact Type Series Booklet

Adjustable swirl diffuser ODZA TECHNICAL DATA

Declaration of performance

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

Evaporator (DX) Freon Applications 1 12 Tons MHF

Control the air. Control your business.

Declaration of Performance (DOP)

Model PDT Dewpoint Transmitter

Extra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole.

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

CALMO

Liquid ring vacuum pumps in compact design

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Sizes JNŽ-6, ANŽ-3, ANŽ-4

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Standard Operating Procedure #COE-SOP-0001 Chemical Fume Hood Operation

JUMO dtrans p30 Pressure Transmitter

Wind turbine Varying blade length with wind speed

market leading commercial and domestic ventilation with heat recovery Nilan VPM Active heat recovery and cooling (air/air)

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Gas density monitor With integrated transmitter Model GDM-100-TI

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

High Pressure Breathing Air Compressors

Liquid level instruments BM 24 /BM 51

50Hz. water solutions. O SerieS DGO DRO

Fire safety of staircases in multi-storey buildings The results of measurements in Buildings and Simulations

CAST IRON SAFETY VALVE TYPE 6301

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

CALEFFI. Motorised temperature regulating unit for heating systems. 167 series 01239/15 GB. replaces dp 01239/13 GB. Function

Etanorm V Type Series Booklet

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Electromechanical pressure switches

WP2 Fire test for toxicity of fire effluents

Liquid ring vacuum pumps in compact design

Level switches Series LD Vibrating fork level switch for liquids and solids

Flow Measurement SITRANS F C

Level switches Series LD Vibrating fork level switch for liquids and solids

AN ISOLATED SMALL WIND TURBINE EMULATOR

Vibration isolated tables. Individually tailored to your requirements.

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Differential pressure

HYDRAULICS. H89.8D - Hydraulic Bench

GROUTEC SCOTT VICKERS. Grouting Equipment

CO 2 radial piston compressor (transcritical)

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

AXIAL FLOW FANS GENERAL INFORMATION

MOBILAIR M 210 / M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.0 to 23.3 m³/min ( cfm) COMPRESSORS

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

PLASTERING UNITS Branded manufacturer of equipment for construction

Liquid ring vacuum pumps in compact design

TeSys protection components

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Air Grinders - Angle

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

SIHI LPH-X - Liquid Ring Compressors

C-Flow Coriolis Mass Flow Meters

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

VARIABLE AIR FLOW REGULATOR

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Proportional pressure regulators VPPE

青岛宝通进出口贸易有限公司. Wind Products List and Introductions

6-5 Maintenance Manual

DIAPHRAGM GAS SAMPLING PUMPS

Features. Description

Compact pressure switches for gas and air

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7. System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

ELECTRIC ACTUATORS for continuous underwater use

SonoMeter 30 Energy Meters

Model MTB-ASME Vertical Bladder Tanks

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

Flow controller Type ED/CCB311 Instruction manual

DLE5.7CN V/60Hz 1~

Transcription:

PRODUCT CONFIGURATOR AT WWW.MERCOR.COM.P mcr Monsun smoke extraction and air supply axial-flow fans

APPICATION mcr Monsun fans are designed to extract hot air, smoke and exhaust gases from fire-exposed areas. They are also suitable for comfort and industrial ventilation systems as exhaust or air supply fans. mcr Monsun fans can be used e.g. in public utility buildings, multi-dwelling buildings, industrial facilities, underground car parks or shopping malls. They facilitate the evacuation of fire-exposed areas and efficient fire fighting operations, protect the building and its equipment against high temperatures, and also prevent fire from spreading into adjoining fire compartments. mcr Monsun fans are designed for ducted or non-ducted mounting, in a vertical or horizontal position, and can be operated inside or outside buildings. mcr Monsun tested in accordance with EN 1211-3:22+AC:25. Certificate of constancy of performance 1488-CPD-345/W for F3 and F2 and 1488-CPD-129/W for F4. Patent no 216872 issued by Patent Office of the Republic of Poland. FIRE RESISTANCE RATING F4 (4ºC/2H) F3 (3ºC/1H) F2 (2ºC/2H) Fans without a fire resistance rating (BO type) are available on an individual basis. DESIGN The housing is made of galvanized steel of a thickness of 2-6 mm, according to the diameter of the fan. The housing is powder coated or hot-dip galvanized for double anti-corrosive protection. The rotor of the fan is mounted directly on the motor pin. It comes with 9 or 12 blades adjustable in 1º steps, and is produced by casting, with an aerodynamically profiled grid of blades which provides the required flow parameters. The rotor can work at different blade angles and with a variable number of blades. Depending on requirements, the fan can be used with a three-phase, one- or two-speed motor with rpm speeds of 3, 15, 1 and 75, without serially-mounted thermal protection. The motor of the fan with a fire resistance rating has Class H insulation, whilst the motor of the fan without a fire resistance rating Class F insulation. The mechanical protection degree is IP 55 in both cases. The motor is adapted for operation with an inverter. 6 2 7 5 1 1. housing 2. axial rotor 3. base support for the motor 4. motor base 5. cable penetrator 6. electric box 7. rotor protection 8. electric motor 8 4 3 2

DIMENSIONS Smoke extraction and air supply axial-flow fans are available in the following diameters: 355 mm, 4 mm, 45 mm, 5 mm, 56 mm, 63 mm, 71 mm, 8 mm, 9 mm, 1 mm. Table 1 mcr Monsun fan dimensions. type D [mm] ~A [mm] ~ [mm] B [mm] C [ ] nxd [mm] mcr Monsun 35 355 425 4 395 45 8 x 9,6 mcr Monsun 4 4 47 5 438 3 12 x 9,6 mcr Monsun 45 45 52 5 487 3 12 x 9,6 mcr Monsun 5 5 57 6 541 3 12 x 9,6 mcr Monsun 56 56 64 7 65 22,5 16 x 1,5 mcr Monsun 63 63 71 6 674 22,5 16 x 1,5 mcr Monsun 71 71 79 75 751 22,5 16 x 1,5 mcr Monsun 8 8 875 75 837 15 24 x 1,5 mcr Monsun 9 9 975 9 934 15 24 x 1,5 mcr Monsun 1 1 18 1 143 15 24 x 1,5 ØB ØD ØA n x Ød ADDITIONA COMPONENTS mounting feet for horizontal installation SW protective grids on the side of the rotor or the motor SO vibration compensators F4 flexible connections KD counterflanges for ducted mounting PK automatic return dampers KS, KS-V vibration isolators AM (F4), BM silencers TH/R service breakers WS components for vertical mounting PP air control blades KP suction nozzles with grill DS outlet port with grill WO 3

ADDITIONA COMPONENTS mounting feet SW fan type A [mm] B [mm] C [mm] d [mm] H [mm] [mm] m [kg] mcr Monsun 35 SW-35 35 245 5 12,5 26 344 1,1 mcr Monsun 4 SW-4 3 24 5 12,5 28 444,9 mcr Monsun 45 SW-45 32 26 5 12,5 32 444 1,1 mcr Monsun 5 SW-5 4 32 5 12,5 35 544 1,4 mcr Monsun 56 SW-56 45 37 5 12,5 375 644 1,7 mcr Monsun 63 SW-63 5 42 5 12,5 425 544 2,1 mcr Monsun 71 SW-71 55 47 5 12,5 475 694 2,4 mcr Monsun 8 SW-8 65 57 5 12,5 525 694 3,1 mcr Monsun 9 SW-9 7 62 6 12,5 575 834 3,4 mcr Monsun 1 SW-1 78 67 7 12,5 65 924 1,2 A B C 2xØd H vibration compensators - flexible connections KD fan type D [mm] ~A [mm] B [mm] [mm] C [ ] nxd [mm] m [kg] mcr Monsun 35 KD-35 355 425 395 15 45 8 x 9,6 1,1 mcr Monsun 4 KD-4 4 47 438 15 3 12 x 9,6 1,3 mcr Monsun 45 KD-45 45 52 487 15 3 12 x 9,6 1,4 mcr Monsun 5 KD-5 5 57 541 15 3 12 x 9,6 1,6 mcr Monsun 56 KD-56 56 64 65 15 22,5 16 x 1,5 1,8 mcr Monsun 63 KD-63 63 71 674 2 22,5 16 x 1,5 2, mcr Monsun 71 KD-71 71 79 751 2 22,5 16 x 1,5 2,3 mcr Monsun 8 KD-8 8 875 837 2 15 24 x 1,5 2,6 mcr Monsun 9 KD-9 9 975 934 2 15 24 x 1,5 2,9 mcr Monsun 1 KD-1 1 18 143 2 15 24 x 1,5 3,2 ØD ØB nxød ØA counterflanges PK fan type D [mm] ~A [mm] B [mm] C [ ] nxd [mm] m [kg] mcr Monsun 35 PK-35 359 425 395 45 8 x 9,6,9 mcr Monsun 4 PK-4 44 47 438 3 12 x 9,6 1, mcr Monsun 45 PK-45 454 52 487 3 12 x 9,6 1,2 mcr Monsun 5 PK-5 54 57 541 3 12 x 9,6 1,3 mcr Monsun 56 PK-56 564 64 65 22,5 16 x 1,5 1,6 mcr Monsun 63 PK-63 634 71 674 22,5 16 x 1,5 1,8 mcr Monsun 71 PK-71 716 79 751 22,5 16 x 1,5 2, mcr Monsun 8 PK-8 86 875 837 15 24 x 1,5 2,1 mcr Monsun 9 PK-9 96 975 934 15 24 x 1,5 2,2 mcr Monsun 1 PK-1 16 18 143 15 24 x 1,5 2,8 ØD ØB nxød ØA automatic return dampers KS, KS-V fan type D [mm] ~A [mm] B [mm] [mm] C [ ] nxd [mm] m [kg] mcr Monsun 35 KS[V]-35 355 425 395 24 45 8 x 9,6 6,6 mcr Monsun 4 KS[V]-4 4 47 438 25 3 12 x 9,6 7,6 mcr Monsun 45 KS[V]-45 45 52 487 29 3 12 x 9,6 9,5 mcr Monsun 5 KS[V]-5 5 57 541 32 3 12 x 9,6 11,3 mcr Monsun 56 KS[V]-56 56 64 65 35 22,5 16 x 1,5 14, mcr Monsun 63 KS[V]-63 63 71 674 36 22,5 16 x 1,5 16,2 mcr Monsun 71 KS[V]-71 71 79 751 43 22,5 16 x 1,5 2,8 mcr Monsun 8 KS[V]-8 8 875 837 47 15 24 x 1,5 24,8 mcr Monsun 9 KS[V]-9 9 975 934 54 15 24 x 1,5 3,9 mcr Monsun 1 KS[V]-1 1 18 143 58 15 24 x 1,5 37,4 ØD ØB nxød ØA components for vertical mounting PP fan type Dn [mm] dp [mm] A [mm] H [mm] B [mm] C [ ] nxd [mm] m [kg] mcr Monsun 35 PP-35 355 12,2 479 5 395 45 8 x 9,6 5,4 mcr Monsun 4 PP-4 4 12,2 524 5 438 3 12 x 9,6 5,8 mcr Monsun 45 PP-45 45 12,2 574 5 487 3 12 x 9,6 6,3 mcr Monsun 5 PP-5 5 12,2 624 5 541 3 12 x 9,6 6,8 mcr Monsun 56 PP-56 56 12,2 684 5 65 22,5 16 x 1,5 7,8 mcr Monsun 63 PP-63 63 12,2 754 1 674 22,5 16 x 1,5 9,1 mcr Monsun 71 PP-71 71 12,2 836 1 751 22,5 16 x 1,5 11,6 mcr Monsun 8 PP-8 8 12,2 926 1 837 15 24 x 1,5 12,4 mcr Monsun 9 PP-9 9 12,2 126 1 934 15 24 x 1,5 13,3 mcr Monsun 1 PP-1 1 12,2 1126 1 143 15 24 x 1,5 15,2 nxød Dn dp A B A H silencers TH/R fan type d1 [mm] d2 [mm] d3 [mm] d4 [mm] [mm] A [ ] nxm m [kg] mcr Monsun 35 TH/R-35 359 55 2 395 95 45 8 x M8 41 mcr Monsun 4 TH/R-4 44 6 22 438 95 3 12 x M8 53 mcr Monsun 45 TH/R-45 454 65 25 487 95 3 12 x M8 56 mcr Monsun 5 TH/R-5 54 7 28 541 95 3 12 x M8 62 mcr Monsun 56 TH/R-56 564 76 315 65 95 22,5 16 x M8 69 mcr Monsun 63 TH/R-63 634 83 355 674 95 22,5 16 x M8 78 mcr Monsun 71 TH/R-71 716 96 4 751 14 22,5 16 x M8 122 mcr Monsun 8 TH/R-8 86 15 45 837 14 15 24 x M1 138 mcr Monsun 9 TH/R-9 96 115 5 934 14 15 24 x M1 155 mcr Monsun 1 TH/R-1 16 125 56 143 14 15 24 x M1 17 d4 d3 d1 d4 d2 A[º] nxm 4

BASIC TECHNICA PARAMETERS Parameters in tables and specifications: Dpc total compression [Pa] Q output [m 3 /h] n motor speed [rpm] P rated power [kw] Un rated voltage [V] W weight of the fan without additional components [kg] The specifications have been established at a temperature of 2 o C and air density of 1.2 kg/m 3. Technical descriptions and specifications for twospeed fans are available on request. motors with n=75 rpm size n P Un W 63/8-,55 75,55 4 6 63/8-,75 75,75 4 68 63/8-,37 75,37 4 56 63/8-,25 75,25 4 52 71/8-1,1 75 1,1 4 11 71/8-,75 75,75 4 14 71/8-,55 75,55 4 96 8/8-2,2 75 2,2 4 143 8/8-1,5 75 1,5 4 127 8/8-1,1 75 1,1 4 118 9/8-4 75 4 4 27 9/8-3 75 3 4 17 9/8-2,2 75 2,2 4 162 9/8-1,5 75 1,5 4 147 1/8-5,5 75 5,5 4 253 1/8-4 75 4 4 247 1/8-3 75 3 4 21 1/8-2,2 75 2,2 4 22 motors with n=1 rpm size n P Un W 5/6-,55 1,55 4 45 5/6-,37 1,37 4 43 5/6-,25 1,25 4 42 56/6-1,1 1 1,1 4 58 56/6-,75 1,75 4 54 56/6-,55 1,55 4 49 63/6-1,5 1 1,5 4 76 63/6-1,1 1 1,1 4 62 63/6-,75 1,75 4 58 71/6-3 1 3 4 132 71/6-2,2 1 2,2 4 119 71/6-1,5 1 1,5 4 11 71/6-1,1 1 1,1 4 97 8/6-5,5 1 5,5 4 16 8/6-4 1 4 4 15 8/6-3 1 3 4 142 8/6-2,2 1 2,2 4 127 8/6-1,5 1 1,5 4 118 9/6-11 1 11 4 23 9/6-7,5 1 7,5 4 22 9/6-5,5 1 5,5 4 179 9/6-4 1 4 4 169 9/6-3 1 3 4 161 1/6-11 1 11 4 27 1/6-7,5 1 7,5 4 242 1/6-5,5 1 5,5 4 219 motors with n=3 rpm size n P Un W 35/2-1,5 3 1,5 4 35 35/2-2,2 3 2,2 4 38 35/2-1,1 3 1,1 4 33 4/2-3 3 3 4 55 4/2-4 3 4 4 58 4/2-2,2 3 2,2 4 44 4/2-1,5 3 1,5 4 4 45/2-4 3 4 4 6 45/2-3 3 3 4 58 45/2-2,2 3 2,2 4 46 5/2-11 3 11 4 129 5/2-7,5 3 7,5 4 1 5/2-5,5 3 5,5 4 92 5/2-4 3 4 4 7 56/2-15 3 15 4 147 56/2-11 3 11 4 136 56/2-7,5 3 7,5 4 17 56/2-5,5 3 5,5 4 99 motors with n=15 rpm size n P Un W 35/4-,55 15,55 4 28 4/4-,75 15,75 4 36 45/4-1,1 15 1,1 4 42 45/4-,75 15,75 4 39 45/4-,55 15,55 4 36 5/4-1,5 15 1,5 4 52 5/4-1,1 15 1,1 4 5 5/4-,75 15,75 4 46 5/4-,55 15,55 4 46 56/4-3 15 3 4 69 56/4-2,2 15 2,2 4 67 56/4-1,5 15 1,5 4 54 63/4-4 15 4 4 81 63/4-3 15 3 4 74 63/4-2,2 15 2,2 4 72 71/4-11 15 11 4 181 71/4-7,5 15 7,5 4 145 71/4-5,5 15 5,5 4 137 8/4-15 15 15 4 27 8/4-11 15 11 4 19 8/4-7,5 15 7,5 4 152 9/4-3 15 3 4 366 9/4-22 15 22 4 286 9/4-18,5 15 18,5 4 237 9/4-15 15 15 4 222 9/4-11 15 11 4 25 1/4-45 15 45 4 524 1/4-37 15 37 4 426 1/4-3 15 3 4 396 1/4-22 15 22 4 315 1/4-18,5 15 18,5 4 266 5

BASIC TECHNICA PARAMETERS Dpc [Pa] 2 18 16 14 12 1 8 6 4 2 335/2 4/2 45/2 5/2 56/2 7 Dpc [Pa] 65 6 55 5 45 4 35 3 25 2 15 1 5 3 6 9 12 15 18 21 24 27 3 33 36 39 42 45 48 51 54 57 6 63 66 69 3 6 9 12 15 18 21 24 27 3 33 36 Q [m 3 /h] Dpc [Pa] 16 14 12 1 8 6 4 15 35/4 4/4 45/4 5/4 56/4 63/4 71/4 2 6 12 18 24 3 36 42 48 54 Q [m 3 /h] 6 66 72 78 84 9 96 8/4 9/4 1/4 1 5/6 56/6 63/6 71/6 8/6 9/6 1/6 Q [m 3 /h] 6

BASIC TECHNICA PARAMETERS 4 35 Dpc [Pa] 3 25 2 15 1 5 7563/8 71/8 8/8 9/8 1/8 3 6 9 12 15 18 21 24 27 3 33 36 39 42 45 48 51 Q [m 3 /h] Mercor s fan configurator is now available at www.mercor.com.pl. Our configurator will provide you with a fan selection record sheet and detailed specifications for the set input parameters. TYPE MARKING mcr Monsun 5 / 4-1,5-15 - F4 / SW additional components fire resistance blade angle [º] electric motor power [kw] number of motor poles rated fan diameter [x1] [mm] fan type 7

FIRE PROTECTION SYSTEMS fire ventilation systems fire protection of building structures smoke and heat exhaust systems Mercor SA ul. Grzegorza z Sanoka 2 8-48 Gdańsk, Poland tel. +48 58 341 42 45 fax +48 58 341 39 85 mercor@mercor.com.pl www.mercor.com.pl