Tabulated Data Lite-Shield 20 System

Similar documents
Aluminum Sheeting Guide (ASG)

STEEL TRENCH SHIELDS TUFF-LITE MODELS

MODULAR ALUMINUM PANEL SHIELDS MAPS

SPEED SHORE MANUFACTURER S TABULATED DATA MANGUARDS. October 31, 2005

"STEEL FRAMED" ALUMINUM PANEL SHIELDS

STEEL TRENCH SHIELDS DW MODELS

SPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS. STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs

SLIDE RAIL INSTALLATION GUIDE MANUFACTURE S TABULATED DATA

"DW" TRENCH SHIELDS "SP" TRENCH SHIELDS "TL" TRENCH SHIELDS "SW" TRENCH SHIELDS MANHOLE SHIELDS

VERTICAL SHORES TRENCH RESCUE SHORES MEGA-SHORES

Seattle City Light Construction Management

TAO Safety Policy No. HS-5.1 Page 1 of 15 Revision No. 2 Revision Date: July 19, 2005

Safety Policy and Procedure

APPENDIX A. Appendix A: Fall Hazards Lesson Test Instructor Copy (answers bold/italic), Student copy to distribute follows

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS HEAVY DUTY HYDRAULIC WALER RAIL SYSTEM. TABULATED DATA Effective August 25, 2015

PACIFIC SHORING, LLC ALUMINUM SHORING PRODUCTS PSH HEAVY DUTY HYDRAULIC WALER RAIL SYSTEM. TABULATED DATA Effective December 10, 2013

TRENCHING/SHORING/EXCAVATIONS Revision Date: 04/2017

Take the high road to ensure underground safety.

ASSEMBLY AND OPERATING MANUAL LTW MAXI TRENCH BOX

A N C H O R T A B S N O R T H W E S T ANCHOR TAB VF. Patented. User Instructions

Marine 6-Boat Free-Standing Racks SKU: Updated November 2011

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 100 & VB 120

Fiber Cable Puller with Tuf-Lugger lite

OSHA 30 Syllabus. Laborers Training School. Time: 40 hours. Maximum Class Size: 30. Prerequisites: None

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 60

Course Length: The course is four sessions for a total of 32 hours.

M S I C R A N E S C A L E

Fall Protection Checklist. Guardrail System

Competent Person - Fall Protection Presented by Turner Safety- your instructor is Steve Turner

Part #: 15158; 15159; 15188; 61027; 61029; 61140; 61141

Fall Protection Resource Guide P AGE 1

Product Name: Universal Guardrail Post

DO NOT THROW AWAY THESE INSTRUCTIONS! READ AND UNDERSTAND BEFORE USING EQUIPMENT!

DREW UNIVERSITY FALL PROTECTION PROCEDURE (DRAFT 12/11)

Versie Date: USAGE AND SAFETY MANUAL SPREADERBEAMS

FALL PROTECTION COMPARISON BETWEEN VARIOUS OSHA STANDARDS, NAVY and EM 385 (2008) REQUIREMENTS

Transfer Chain (SA-1002) & Adjustable I-Beam Clamp (SA-1039 or SA-1040) Operating Instructions

Operator Manual Fax

Product Name: Angel Anchor

FEDERATION OF PILING SPECIALISTS CODE OF INDUSTRY BEST PRACTICE LIFTING OPERATIONS AND LIFTING EQUIPMENT REGULATIONS 1998

User Instruction Manual. Trauma Relief Pack. Part Number: RL-TRP. ISO 9001: 2008 Registered Manual

FALL PROTECTION INTEGRITY QUALITY INNOVATION

FALL PROTECTION / ELEVATED WORK

BP OIL -- TOLEDO REFINERY

MANITOWOC MODEL TON CAPACITY

ARKANSAS TECH UNIVERSITY FACILITIES MANAGMENT HEALTH AND SAFETY MANUAL

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Product Name: Non-Shock Lanyard

Required Courses. Total Hours 39

VACUUM EXCAVATION BEST PRACTICE & GUIDELINE

Title- Fall Protection Effective Date: 03 Jan 14 Revision-0

FALL PROTECTION PLAN FALL PROTECTION PROGRAM

Above ground or below, worker and jobsite safety is your priority and ours.

Confined Space Entry

HIPPLOCK. User s Safety Manual

Written Program. For. Fall Protection. <<Company Name>> <<911 Address>> <<City, state, zip code>>

Confined Space in Construction

Permanent Roof Anchors

Chain Sling Saddle Rings

Product Name: Standing Seam Roof Clamp

Occupational Protective Equipment

Caught in or Between Hazards

Product Name: Concrete Anchor Strap

Product Name: 2-Way Standing Seam Roof Clamp

Product Name: Internal Shock Lanyard

Confined Space in Construction

Walking-Working Surfaces Fall Protection Program

MODEL SWH10 1,000 LB CAPACITY SWIVEL HOIST

OWNER'S MANUAL. Turnbuckle. Stanchions. Warning

Ground Release Shackle

INSTRUCTION MANUAL HEAVY-DUTY BEAM TONGS MODEL BT (20, 40, & 60)

8. Fall Protection Procedures WAC

Progressive Safety Services LLC

INSTRUCTIONS FOR USE

Rigging Safety 16 Hour (API RP 2D 7 th Edition) Course Outline

GEMTOR. ... when your life is on the line OWNER'S MANUAL. FLW Series Self-Retracting Lanyard/Fall Limiter

Lisle-Woodridge Fire District Trench Rescue STANDARD OPERATING GUIDELINES

BUTTERFLY VALVES Series 800

Developed by Engineers Alex Klinger and Shelby Vrem November 2015

Product Name: Hold Me Rope Anchor

P R I M A X. The Most Advanced Shoring Devices SAFER - FASTER - DEEPER - CHEAPER THE ULTIMATE SHORING TECHNIQUES ARE NOW ON YOUR HANDS

TRENCH AND EXCAVATION COLLAPSE

SafetyBuletin. Se ingoutriggerstopreventaccidents

Harley-Davidson Motor Company

FALL PROTECTION

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Risk Control at United Fire Group

Operator's Manual Supplement

OSHA Federal Standards October 1, 2016 September 30, 2017

Product Name: Edge Angel SRL

Overview of Today s Program

FALL PROTECTION PLAN INSTRUCTIONS

1.0 Purpose: To provide guidelines for selection, usage, inspection and rejection of rigging equipment

Regulations of Ski Slope "OZOLKALNS" Use Agreement 1 GENERAL PROVISIONS 1.1 These regulations of ski slope OZOLKALNS use agreement shall stipulate

Product Name: Bull Ring Anchor

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

New OSHA Rescue Requirements for Confined Space Retrieval: What You Should Know

Confined Space Entry Procedure

Product Name: Alligator Guardrail System

Transcription:

Tabulated Data Lite-Shield 20 System November, 2014 Copyright, U.S.A.,Griswold Machine & Eng., 2012 594 Mendon Road, Union City, MI 49094 (800) 248-2054 Fax: (517) 741-7483

CAUTION EXCAVATION PROCEDURES MAY CAUSE INJURY OR DEATH! A COMPETENT PERSON WHO SATISFIES THE DEFINITION AND INTENT OF THE 1926 CONSTRUCTION STANDARD SUBPART P EXCAVATIONS SHALL: ENSURE THAT ALL EMPLOYEES ARE WORKING IN SAFE CONDITIONS AND THAT ALL EMPLOYEES HAVE BEEN TRAINED IN CORRECT EXCAVATION PROCEDURES AND THE PROPER USE OF THE PROTECTIVE EQUIPMENT CHOSEN. EXCAVATIONS AND PROTECTIVE EQUIPMENT SHALL BE INSPECTED A MINIMUM OF ONCE EACH WORKING DAY AND WHENEVER THERE IS A CHANGE IN THE SOIL CONDITIONS AND/OR OTHER CHANGES SUCH AS AN INCREASE OR DECREASE IN WATER OR VIBRATIONS. EMPLOYEES SHALL NOT BE ALLOWED TO ENTER AN EXCAVATION THAT IS NOT PROPERLY SHORED, SHIELDED, OR SLOPED. EMPLOYEES SHALL ALWAYS ENTER, WORK, AND EXIT WITHIN THE SHORED, SHIELDED, OR SLOPED AREAS OF THE EXCAVATION AND/OR TRENCH. ALL LIFTING AND PULLING EQUIPMENT, INCLUDING CABLES, SLINGS, CHAINS, SHACKLES AND SAFETY HOOKS SHALL BE INSPECTED FOR DAMAGE OR DEFECTS PRIOR TO USE AND SHALL BE EVALUATED FOR SUITABILITY AND CAPACITY. THIS GME TABULATED DATA PROVIDES A GENERAL SET OF GUIDELINES TO ASSIST THE COMPETENT PERSON IN THE SELECTION OF A PROTECTIVE SYSTEM FOR EMPLOYEE SAFETY. THE RESPONSIBILITY FOR JOB SITE SAFETY AND THE PROPER SELECTION, INSTALLATION AND REMOVAL OF THE SHORING EQUIPMENT BELONGS TO THE COMPETENT PERSON DESIGNATED FOR THAT JOBSITE. THIS TABULATED DATA IS NOT INTENDED TO BE USED AS A JOB SPECIFIC EXCAVATION/TRENCHING SAFETY PLAN, BUT SHALL BE USED BY THE COMPETENT PERSON. TABULATED DATA IS INTENDED AS A SUPPLEMENT TO HIS/HER TRAINING, EXPERIENCE AND KNOWLEDGE OF SAFE PROCEDURES, JOB SITE CONDITIONS AND SOIL TYPES. TABULATED DATA IS INTENDED TO ASSIST HIM IN THE SELECTION OF AN APPROPRIATE PROTECTIVE SYSTEM FOR EMPLOYEE SAFETY. 2

LITE-SHIELD 20 SYSTEM TABULATED DATA GENERAL: 1. This data has been prepared by a Registered Professional Engineer as required OSHA standard 29 CRF, Part 1926, Subpart P, Excavations. 2. This data is to be used by the "competent person" for the proper use and placement of the Lite-Shield 20 System components. 3. "Competent person" is one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. 4. When there is a discrepancy concerning the use of protective systems between this tabulated data and the OSHA standard, this data shall take precedence. Any topic not covered by this data shall be governed by the OSHA standard. 5. GME shall not be liable for damage or injury resulting from improper use of the Lite Shield System. Improper use of or modifications to the structural components not specifically authorized by GME without the written consent of GME shall void this data and all manufacturers warranty. SPECIFICATIONS FOR USE OF THE LITE-SHIELD 20 SYSTEM 1. All personnel involved with the use of Lite-Shield 20 System shall be trained in the proper use and installation procedures and other applicable safety requirements. 2. The Lite-Shield 20 System shall be used only in soil conditions indicated in this data. 3. Refer to the installation procedures for typical installation figures. 4. The system shall be installed in a manner to prevent lateral or otherwise hazardous movement. 5. The struts shall not be used to support side loading, nor shall the system be lifted, pulled or moved by the struts. The system shall be installed and extracted by the lifting eyes provided by the manufacturer. Struts are not designed to support vertical loads and shall not be used to provide access or egress to the trench 3

LITE-SHIELD 20 SYSTEM TABULATED DATA SPECIFICATIONS FOR USE OF THE LITE-SHIELD 20 SYSTEM CON T 6. This data is valid for Lite-Shield 20 components in structurally sound condition. Any significant damage will void this data, and all manufacturers warranty. The damaged components shall not be used. 7. When the system is used in a three or four-sided assembly, a bottom panel may be left out on one side or on two opposite sides. SOIL CLASSIFICATION 1. See the OSHA regulations for descriptions of Type A, B, and C soils. 2. Type C-60 soil is a soft cohesive or moist granular soil that is not flowing or submerged. This soil can be cut vertically and will stand long enough to safely install the protective system. NOTES FOR TABULATED DATA 1. The top strut of the system shall be no more than twenty-four inches below the top of the panel elements. 2. The lowest strut of the system shall be no more than twenty-four inches above the bottom of the excavation. All additional struts shall be spaced at a maximum of forty-eight inches to the top of the excavation. 3. PC Connectors shall be pinned at each panel joint and struts shall be connected to the PC Connectors. 4. Surcharge loads are not included in the maximum depth tables. Surcharge loads are possible due to heavy equipment, vibrations, or soil piles adjacent to the trench. (Adjacent is defined as within a distance equal to the depth of the trench.) 5. If the system is used in a three or four-sided configuration with different sized panels, the maximum depth of the excavation shall not exceed the depth rating of the longer panel as indicated in the maximum depth table. 6. All strut components shall be approved or manufactured by GME. 4