Becker * Condensed Catalog

Similar documents
Becker Precision Equipment

Masoneilan * DSH * Series Desuperheater

Becker Precision Equipment

Becker* Model FD-1500 Filter/Dryer

Masoneilan* 78 Model Air Filter Regulator

Becker* Products Below Ground Ball Valve Regulators

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Masoneilan* Model 78-80S & 08-80S Transfer Valves

Becker * T-Ball * Anti-Surge Valve

Masoneilan* Model 78-80H & 08-80H Transfer Valves

829S1 Series Flexflo Pilot

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Fisher 2625 and 2625NS Volume Boosters

BACK PRESSURE / SUSTAINING

HON C210 Series Control Valves. High Pressure Control valves

BACK PRESSURE / SUSTAINING

Solutions for Natural Gas PRODUCT SOLUTIONS OVERVIEW

Pressure and Flow Control Valves DBGM, German and European Patents

SB AXIAL FLOW VALVES

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Instruction Manual for the VRP-CH Valve Regulator Pilot

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Masoneilan* Series Self Operating Pressure Regulators

I Connected Industrial. HON 5020 Gas Pressure. Enabling Dependable Gas Operations

Direct Operated Precision Regulator Modular Style. Standard Specifications

Pressure on Demand. Air Pressure Amplifiers

Types ACE95 and ACE95Sr Tank Blanketing Valves

ACTUATORS AND INSTRUMENTS

Increase Gas Production, Reduce Maintenance and Decrease Environmental Risks

Fuel Gas Pressure Control Solutions for Fired Heaters and Boilers

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

Series 2G Diaphragm Actuators

Types ACE95 and ACE95Sr Tank Blanketing Valves

Mooney* Series 21 Regulator

Types ACE95 and ACE95Sr Tank Blanketing Valves

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

VALVES OPERATION, MAINTENANCE & TROUBLESHOOTING

PRO-50 Instrument Supply Regulator

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

FILTER BYPASS CONTROL

Deltaflux Control Valve

Model 4000 Pressure Controller

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Type EZH Relief or Backpressure Regulator

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

Type Cronos Pressure Reducing Regulator

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Type 92S Pilot-Operated Steam Regulator

RD(H)20/25 Pressure-Reducing Regulator User Manual

I Connected Industrial. HON 5020 GAS PRESSURE REGULATOR Enabling Dependable Gas Operations

Power Valve: Precision Regulator. High precision, large capacity relief regulator

64 Series Pressure Reducing Regulators

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Fisher L2sj Low Emission Liquid Level Controller

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

1805 Series Relief Valves

Float Operated Level Controllers

The Ins and Outs of I/P Transducers

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Type ACE95jr Tank Blanketing Valve

Screw Compressors 11-22kW

Model 10. Low-Medium Pressure Reducing Regulator

TECHNICAL DATA. Page 1 of 12

Application Worksheet

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Fisher DVI Desuperheater Venturi Inline

Improve Reliability of Turbomachinery Lubrication and Sealing Systems

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type R622 Pressure Reducing Regulator

Fisher Optimized Antisurge Control Valves High reliability to meet world-class production demands

1200 Series Pressure Regulators

CAPITAL CONTROLS SERIES NXT3000

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

SINGLE VALVE WITH LOW-FLOW BYPASS

Design DSA Steam-Atomized Desuperheater

OPERATING AND MAINTENANCE MANUAL

M-System s I/P and P/I Transducers

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

VBL Volume Booster. Features. D103393X012 January 2013

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Petro-Chemical & Analyzer Sampling Systems

Electropneumatic Transducer (I/P) Installation, Operation and

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Gas Pressure Regulator HON 200

Transcription:

Becker * Condensed Catalog Outstanding Reliability, Accuracy and Control bhge.com

Since 1955, Becker control valve assemblies have been delivering exceptional performance to the natural gas industry. Complete regulator systems from BHGE, including Becker control valves, valve regulators, actuators and pneumatic controls, have earned a reputation for outstanding reliability, accuracy and control. Highlighting their advanced engineering technology, these systems continue to provide proven service to customers around the globe. 2

Outstanding Products, Advanced Technology All components of a regulator system must work together to maintain a desired set point of processes that vary in the system including pressure and flow rate. Becker control valve assembly components work in synergy to produce a number of competitive advantages. Valve Regulator. BHGE s unique Becker ZERO BLEED* Valve Regulator Pilot (VRP) instrumentation acts as the brains of the system, effectively combining the capabilities typically found in two devices -- a controller and a positioner. It senses information about each process variable, processes its relationship to the desired set point, and communicates this information to the actuator. Actuator/Pneumatic Controls. Based on the information received from the valve regulator, the actuator supplies the force and motion to open or close the control valve, which then adjusts for deviations in the set point. Our pneumatic control systems provide unsurpassed control capability with easy adjustment and negligible to non-existent atmospheric bleed. Becker actuators can be supplied with custom-designed control systems to meet highly specific customer requirements. Whether installed in the field or factoryassembled, they can be tested on the valve of your choice. Control Valve. The control valve affects the flow of fluid to control pressure differential, flow rates, velocity and noise. A variety of different Becker T-Ball* rotary-style control valves are available to best fit your needs. In-depth Knowledge & Experience BHGE s engineering staff offers a wealth of knowledge and decades of experience related to control valve technology and applications. Let us help you create a regulator system that is best suited to your precise application. Becker control valve assembly products and accessories provide exceptional quality and performance backed by the significant engineering experience and ongoing support of BHGE. T-Ball Control Valve Advantages Becker T-Ball rotary-style control valves from BHGE are ideally suited for natural gas applications. They offer significant competitive advantages compared to cage-style valves (axial and globe): Self-cleaning Design. The rotating ball allows for debris in the pipeline to be swept downstream rather than building up in the valve, reducing maintenance time and costs, and maximizing uptime. Standard Bi-Directional Flow. The ball design of the valve allows for media to travel in both directions of the pipeline, resulting in significantly reduced infrastructure requirements and costs. High Capacity & Turndown. Our control valves can handle high flow volumes while effectively maintaining accurate control in both high and low flow rates. The T-Ball design can handle flow volume equivalent to approximately two axial-style valves or three globe-style valves, offering a substantially reduced station/ infrastructure footprint. Below Ground Installation. Unlike cage-style valves, T-Ball control valves can be buried below ground, providing several key benefits: Reduced noise levels by up to an additional 35 dba (offers a more cost-effective solution than silencers and capacity reducing trim designs) 3

Becker Rotary Control Valves T-Ball Control Valve Now, more than ever, the energy industry is pushing the limits to maximize process yields while maintaining a safe, efficient and sustainable operation. The T-Ball control valve, combined with advantages of Becker pneumatic or electronic actuation and instrumentation provides an engineered solution for an array of gas or liquid applications that may require aggressive noise attention, high pressure differential, large mass flows with extreme precisions and reduced emissions. The patented T-Ball rotary control ball valve offers a unique design with its inlet and outlet diffusers that engage the valve. Combined with, it s quarter-turn operation it has the inherent capability to control over a wide range of process conditions while maintaining low-impact, quick and smooth modulation. Time and time again, the T-Ball has proved to provide customers worldwide with process management solution for pipeline applications ranging from oil and gas production, processing, transitions, storage and distribution. Trim Selection Through a series of trims for gas or liquid, the T-Ball is customized to suit specific application needs. An FPCV-T0 is ideal for applications that require high mass flow rates with minimum pressure differentials while an application that requires high pressure differential and aggressive noise attention a QTCV-T4 model can be used. Becker T-Ball Model FPCV-T0 QTCV-T1 QTCV-T2 QTCV-T4 Noise Attenuation Baseline 7 dba 17 dba 25 dba 4

Becker Series V-0 Control Valve Series V-0 Control Valve The Becker V-0 Control valve is a segmented type rotary control valve designed for mild duty regulation. The V-0 features a high capacity design in a very compact package by utilizing Becker RSD Rotary Spring and Diaphragm actuators paired with environmentally friendly ZERO BLEED digital or pneumatic instrumentation. The V-0 control valve is ideal for gas production, midstream, distribution and transmission applications and can be used for: Flow Control Pressure Control Over Pressure Protection Under Pressure Protection 5

Becker Rotary Series High Pressure Actuators RPDA Rotary Piston Double Acting Actuator Bleed to Pressure System* can eliminate bleed gas emissions Retrofits to almost any pipeline valve High pressure RPDA accepts natural gas up to 500 psig (3,447 kpa) Upright actuator design saves space and promotes longer actuator piston seal life Designed to be maintenance free All RPDAs come equipped with a precision linear scale that indicates valve position in ten degree increments Crank-arm design actuators specifically suited for control valve applications May be mounted in any orientation RPSR Rotary Piston Spring Return Actuator Bleed to Pressure System* can eliminate bleed gas emissions Retrofits to almost any pipeline valve High pressure RPSR accepts natural gas up to 500 psig (3,447 kpa) Upright actuator design saves space and promotes longer actuator piston seal life Designed to be maintenance free All RPSRs come equipped with a high visibility scale that indicates valve position Crank-arm design actuators specifically suited for control valve applications May be mounted in any orientation 6

Becker Linear Series Low and High Pressure Actuators with Globe Valves LD Linear Diaphragm Utilized when available power gas pressure is less than 50 psig (344 kpa) High power output with low power gas supply Simple instrumentation design ZERO steady state bleed gas when utilizing Model HPP-SB Positioner or Model VRP-SB Pilot Becker Globe Valve Characteristics CV 1" - 8" lines High capacity (larger holes) Small to medium power plants Top entry design facilitates maintenance and allows in-line valve service Interchangeable internal components Throttling while at maximum pressure drops LPDA Linear Piston Double Acting Bleed to Pressure System* can eliminate bleed gas emissions Retrofits to almost any pipeline valve Available with a weather seal design to protect piston rod High Pressure LPDA Actuator accepts natural gas up to 500 psig (3447 kpa) Upright actuator design saves space and promotes longer actuator piston seal life Maintenance free design All LPDAs come equipped with a precision linear scale that indicates valve position in ten degree increments 41005 & 21000 Series 1" - 16" lines High noise attenuation (smaller holes) Higher pressure drop capabilities Reduce actuator size and thrust requirements Improved stability with larger guide areas Increase low noise and anti-cavitation trims LPSR Linear Piston Spring Return Bleed to Pressure System* eliminates bleed gas emissions Retrofits to almost any pipeline valve High Pressure LPSR Actuator accepts natural gas up to 400 psig (2758 kpa) Maintenance free design All LPSRs come equipped with a high visibility scale that indicates valve position Specifically suited for heavy duty control valve applications. Surge Design available for high speed stroking up to 750 msec Field reversible 7

Becker Valve Regulator Pilot (VRP) and VRP retrofit The Becker Valve Regulator Pilot (VRP) provides pneumatic pressure control for gas applications. The VRP measures the downstream pressure and utilizes pipeline gas to power the actuator and position the valve to maintain the desired setpoint. The VRP provides the following benefits: Maintains control within 0.75% of desired setpoint Combines the functions of a positioner and a controller into a single device ZERO steady state emissions Unique to Pressure System can completely eliminate instrumentation emissions Models suitable for both double acting and single acting actuators Ability to retrofit to any style valve already in the field VRP-SB-CH Pilot 3-way Valve MCV Schematic Legend n Sensing Pressure (P 2) n Upstream Pressure (P 1 ) n Exhaust (Discharge) n Supply Gas (Regulated) n Power Gas Pressure (Actuator) RPSR Fail Closed FD-1 Gas Supply System T-Ball* Control Valve Flow Rather than venting gas to the atmosphere, gas is displaced downstream back into the pipeline, completely eliminating emissions and providing a true ZERO BLEED system. 8

For control valve instrumentation that is obsolete, providing poor control or exhibiting high emissions a Becker VRP can easily replace instrumentation on an existing control valve in service. Studies have shown that pneumatic control valve instrumentation annually can vent up to 500,000 scf of methane into the environment. Maintaining a sustainable, environmentally friendly operation is becoming an increasingly top priority for many pipeline operator. A single VRP retrofit can potentially reduce or even eliminate those emissions with the Bleed to Pressure System. This reduction is equivalent to approximately 25 metric tons of CO 2 which is equivalent to: The annual greenhouse gas emissions from 5 passenger vehicles 1 Carbon sequestered annually by 5 acres of pine or fir forest 1 1 Source: EPA Greenhouse Gas Equivalencies Calculator 9

Becker HPP Pneumatic Positioners Provide Accurate Positioning of Control Valves with Reduced Bleed Emissions leed to pressure system TM bbleed to pressure system HPP-SB models for Single-Acting Applications The Becker HPP provides accurate positioning for both single-acting and double-acting actuated control valves. It can be configured in both reverse and direct-acting with a variety of instrument signal input ranges. The device accepts a pneumatic instrument signal from an I/P transducer or a pneumatic controller. The HPP provides the following benefits: High flow capacity ideal for fast acting applications ZERO steady state bleed and when in full open and closed Elimination of instrumentation emissions when combined with Bleed to Pressure System Vibration resistant design maintains calibration 10

Becker DNGP Digital Natural Gas Positioner The DNGP can be used with both double acting and single acting actuators. The Digital Natural Gas Positioner (DNGP) is used with pneumatically actuated control valves in gas applications for both flow and pressure control. The device accurately positions the valve stem proportionally to the command of the input signal received from an electronic controller. The DNGP provides the following benefits: Eliminates the need for an I/P transducer ZERO bleed consumption at steady state Easy, menu driven setup along with PC interfaced diagnostic and setup features High volume and pressure capabilities ideal for large volume pneumatic actuators Multiple fail safe mode options Modbus communication protocol 11

Commitment to the Environment Sustainable and environmentally friendly technology is a continuously growing industry trend. The environmental impact of noise and pollution from natural gas regulating stations is becoming an increasingly important design consideration. Many methods of handling excessive noise, such as downstream silencers, extra-thick pipe, and enclosure buildings, only offer a partial solution and multiply project costs. Buried installation of T-Ball control valves can easily be configured with a robust extended stem design. This can eliminate ambient noise problems (up to 37 dba) by the earth s absorption of noise producing vibrations. Due to the T-Ball s inherent non-clogging, low maintenance design, your station is not required to be frequently unearthed and serviced. Besides optimum noise control and infrastructure reduction, buried service provides considerable benefits: Ability to Handle Higher Flow Volumes Minimize Ambient Heat Loss Additional Asset Security Safer Atmosphere for Operating Personnel Compliance with Environmental Regulations and City Ordinances 40 Noise Attenuation As Factor of Below Ground Depth Resulting Attenuation Factor (dba) 30 20 10 0 3 ft. Burial 4 ft. Burial 5 ft. Burial 6 ft. Burial Burial depths typically range from 3 ft (1m) to 6 ft (2m) and can provide in excess of 37 dba of additional noise attenuation. 12

Combustion Turbine Power Plants Regulator/Trim Run Solution This application provides the challenge of essentially requiring infinite turndown (to meet the small gas flow rate demands of ancillary equipment), allowing for smooth start-up of the Combustion Turbine, and providing enough capacity for multiple turbines at 100% loads. Additionally, the control valve system must have exceptional speed of response because of the proximity to the combustion turbines. This speed of response cannot come at the expense of maintaining stable steady-state control. This is especially critical to the commissioning of new Combustion Turbine power plants as fluctuating inlet pressure to the Combustion Turbines will not allow the units to pass emission requirements and could cause a unit or multiple units to trip off line. Trim Run/Main Run Design Valve Position v/s Flow Rate The Main Run provides all the gross gas load requirements at setpoint pressure, and the quicker Trim Run maintains the fine control no matter how many Combustion Turbines come on line. The Trim Run will operate between 40-60% open under normal operation with 50% as its target position for the station set-point. This identical process will take place in the opposite direction if there is a large decrease in gas flow rate demand. It is this ability to satisfy both large and small gas load requirements at the same time and maintain control that makes this design the right choice for Combustion Turbine power plants. By having both runs in control and having the Trim Run as the leading function, the station will have a fast speed of response coupled with tight control capability and a stable delivery pressure, under all operational conditions. 13

Becker Accessories MCV The MCV Series Manual Control Valve provides manual operation of pneumatic valve actuators. The MCV is the ideal device for maintenance and manual operation of control valves. The MCV allows the user to override the primary control instrumentation and position the control valve actuator. The unique safety button feature of the MCV prevents unintentional operation. An optional locking feature is available for additional security. Max. Allowable Operation Pressure Model MCV-3: Up to 150 psig (1034 kpa) All Ports: 1/4 FNPT Model MCV-3M: 150-250 psig (1034-1724 kpa) Weight: 10 lbs (4.5 Kg) Model MCV-3H: 250-500 psig (1723 kpa - 3447 kpa) Gear Operator Override The manual handwheel is utilized for manual operation of small and medium sized control valves when pneumatic power is not available. The handwheel utilizes a system of gear multipliers to develop necessary torque to open and close the control valve. No-Bleed Valve NBV Series The No-Bleed Valve NBV Series eliminates bleed gas from Becker double-acting control instrumentation when corresponding control valve is at full-open and full-closed positions. This is ideal for monitor regulators and standby regulators that typically remain in the full-open or full-closed positions for extended periods of time. The NBV features bleed shutoff at both ends of valve travel without adjustment. The NBV is the primary choice for Non-Bleed technology on Becker double-acting control instrumentation. The NBV is compatible with all Becker double acting Valve Regulator Pilots (VRPs) and double acting High Pressure Positioners (HPPs). PS-2 Series Non-Bleed Sensor The PS-2 Series Non-Bleed Sensor eliminates bleed gas from Becker seat and nozzle type double-acting control instrumentation when corresponding control valve is at full-open or full-closed positions. This is ideal for monitor regulators and standby regulators that typically remain in the full-open or full-closed positions for extended periods of time. The PS-2 features bleed shutoff at one end of valve travel. If bleed shutoff is required at both ends of valve travel, two PS-2 Non-Bleed Sensors are required. The PS-2 is typically utilized for high pressure power supply gas greater than 150 psig (1034 kpa) or when Bleed to Pressure System (BPS ) discharge pressures exceed 60 psig. The PS-2 is compatible with the following Valve Regulator Pilots (VRPs) and High Pressure Positioners: Models VRP, VRP-CH, HPP-4. PIC & GSP Series Pressure Instrumentation Columns The Becker PIC and GSP Series Pressure Instrumentation Columns provide (413 kpa) regulated and conditioned supply pressures for control valves and instrumentation utilized in natural gas pipeline applications. PICs are available with a variety of options and configurations, such as catalytic (flameless) heaters, filter-dryers, instrumentation mounting brackets. The Becker PIC is the original column designed for use in natural gas distribution and transmission pipelines. 14

15

DIRECT SALES OFFICE LOCATIONS AUSTRALIA Brisbane: Phone: +61-7-3001-4319 Fax: +61-7-3001-4399 Perth: Phone: +61-8-6595-7018 Fax: +61-8-6595-7299 Melbourne: Phone: +61-3-8807-6002 Fax : +61-3-8807-6577 BELGIUM Phone: +32-2-344-0970 Fax: +32-2-344-1123 BRAZIL Phone: +55-19-2104-6900 CHINA Phone: +86-10-5738-8888 Fax: +86-10-5918-9707 FRANCE Courbevoie Phone: +33-1-4904-9000 Fax: +33-1-4904-9010 GERMANY Ratingen Phone: +49-2102-108-0 Fax: +49-2102-108-111 INDIA Mumbai Phone: +91-22-8354790 Fax: +91-22-8354791 New Delhi Phone: +91-11-2-6164175 Fax: +91-11-5-1659635 ITALY Phone: +39-081-7892-111 Fax: +39-081-7892-208 JAPAN Tokyo Phone: +81-03-6871-9008 Fax: +81-03-6890-4620 KOREA Phone: +82-2-2274-0748 Fax: +82-2-2274-0794 MALAYSIA Phone: +60-3-2161-0322 Fax: +60-3-2163-6312 MEXICO Phone: +52-55-3640-5060 THE NETHERLANDS Phone: +31-15-3808666 RUSSIA Veliky Novgorod Phone: +7-8162-55-7898 Fax: +7-8162-55-7921 Moscow Phone: +7 495-585-1276 Fax: +7 495-585-1279 SAUDI ARABIA Phone: +966-3-341-0278 Fax: +966-3-341-7624 SINGAPORE Phone: +65-6861-6100 Fax: +65-6861-7172 SOUTH AFRICA Phone: +27-11-452-1550 Fax: +27-11-452-6542 SOUTH & CENTRAL AMERICA AND THE CARIBBEAN Phone: +55-12-2134-1201 Fax: +55-12-2134-1238 SPAIN Phone: +34-93-652-6430 Fax: +34-93-652-6444 UNITED ARAB EMIRATES Phone: +971-4-8991-777 Fax: +971-4-8991-778 UNITED KINGDOM Bracknell Phone: +44-1344-460-500 Fax: +44-1344-460-537 Skelmersdale Phone: +44-1695-526-00 Fax: +44-1695-526-01 UNITED STATES Jacksonville, Florida Phone: +1-904-570-3409 Deer Park, Texas Phone: +1-281-884-1000 Fax: +1-281-884-1010 Houston, Texas Phone: +1-281-671-1640 Fax: +1-281-671-1735 bhge.com *Denotes a trademark of Baker Hughes, a GE company LLC. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. 2018 Baker Hughes, a GE company LLC - All rights reserved. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your BHGE representative for the most current information. The Baker Hughes logo is a trademark of Baker Hughes, a GE company. The GE Monogram is a trademark of the General Electric Company. GEA19191C 10/2018